• 제목/요약/키워드: rapid measurements

검색결과 438건 처리시간 0.03초

졸-겔법에 의한 $(Pb_{0.9}Ca_{0.1})TiO_3$ 박막의 강유전 특성 (Ferroelectric Properties of $(Pb_{0.9}Ca_{0.1})TiO_3$ Thin Films by Sol-Gel Processing)

  • 김행구;정수태;이종헌
    • 한국전기전자재료학회논문지
    • /
    • 제11권2호
    • /
    • pp.138-145
    • /
    • 1998
  • The $(Pb_{0.9}Ca_{0.1})TiO_3$[PCT] thin films have been deposited by sol-gel processing on Si-wafer and ITO glass substrates. The creak-free films have been obtained by rapid thermal annealing at $700^{\circ}C$ for 10 minute and characterized by XRD, SEM and electrical measurements. Their tetragonality c/a was 1.041 and grain size was $0.15{\sim}0.2{\mu}m$. When the electrode system of sample was Au/PCT/ITO(MFM) and film thickness was $0.8{\mu}m$, dielectric constant, dielectric loss and Curie temperature were about 149, 0.085 and $449^{\circ}C$ at 10kHz, respectively. Spontaneous polarization $P_s$, remnant polarization $P_r$ and coercive field $E_c$ were about $5.29{\mu}C/cm^2$, $4.15{\mu}C/cm^2$ and 82kV/cm calculated by hysteresis loop.

  • PDF

동축 이중 에틸렌 확산화염의 매연 농도분포 및 온도 측정 (Soot Concentration and Temperature Measurements in Laminar Ethylene Jet Double-concentric Diffusion Flames)

  • 이교우;정종수;황정호
    • 대한기계학회논문집B
    • /
    • 제26권3호
    • /
    • pp.402-409
    • /
    • 2002
  • Experiments were performed with double-concentric diffusion flame(DDF) in order to investigate the characteristics of soot formation and temperature distributions. The flame size and shape of the DDF are similar to those of the well-known normal co-flow diffusion flame(WF), except the formation of a tiny inverse flame near the central tube exit. A laser light extinction technique was used to measure the soot volume fractions. The temperature distributions in the flame were measured by rapid insertion of a R-type thermocouple. Soot concentrations along the flame axis of the DDF were higher than those of the NDF. However, the maximum soot volume fraction of the DDF along the periphery of the flame was lower than that of the NDF. It is mainly due to the effect of nitrogen-dilution from the inner air. Measured temperature distribution explains these trends of soot concentration. The temperature along the flame axis was also higher in DDF than that of the NDF. However, the flame temperatures at the flame front of the two flames were almost same regardless of the inner flame. This phenomenon means that the inverse flame inside the DDF did not affect on the flame structure including the temperature and soot concentration, except the region around the flame axis.

RF 스퍼터링법을 이용한 $LiNbO_3/Si$구조의 전기적 및 구조적 특성 (Electrical and Structural Properties of $LiNbO_3/Si$ Structure by RF Sputtering Method)

  • 이상우;김광호;이원종
    • 한국전기전자재료학회논문지
    • /
    • 제11권2호
    • /
    • pp.106-110
    • /
    • 1998
  • The $LiNbO_3$ thin films were prepared directly on Si(100) substrates by conventional RF magnetron spurttering system for nonvolatile memory applications. RTA(Rapid Thermal Annealing) treatment was performed for as-deposited films in an oxygen atmosphere at 600 $^{\circ}C$ for 60 s. The rapid thermal annealed films were changed to poly-crystalline ferroelectric nature from amorphous of as-deposition. The resistivity of the ferroelectric $LiNbO_3$ film was increased from a typical value of $1{\sim}2{\times}10^8{\Omega}{\cdot}cm$ before the annealing to about $1{\times}10^{13}{\Omega}{\cdot}cm$ at 500 kV/cm and reduced the interface state density of the $LiNbO_3/Si$ (100) interface to about $1{\times}10^{11}/cm^2{\cdot}eV$. Ferroelectric hysteresis measurements using a Sawyer-Tower circuit yielded remanent polarization ($P_r$) and coercive field ($E_c$) values of about 1.2 ${\mu}C/cm^2$ and 120 kV/cm, respectively.

  • PDF

실시간 제어를 위한 고속 열처리 공정에서 웨어퍼 온도 분포 추정 기법 (A Prediction Method of Temperature Distribution on the Wafer for Real-Time Control in a Rapid Thermal Process System)

  • 심영태;이석주;김학배
    • 제어로봇시스템학회논문지
    • /
    • 제6권9호
    • /
    • pp.831-835
    • /
    • 2000
  • The uniformity of themperature on a wafer is a wafer is one the most important parameters to conterol the RTF(Rapid Thermal Process) with proper input signals. It is impossible to achieve the uniformity of temperature without the exact estimation of temperature ar all points on the wafer. There fore, it is difficult to understand the internal dynamics as well as the structural complexities of the RTP, which is aprimary obstacle to measure the distributed temperatures on the wafer accurately. Furthermore, it is also hard to accomplish desirable estimation because only a few pyrometers are available in the general equipments. In the paper, a thermal model based on the chamber grometry of the AST SHS200 RTP system is developed to effectively control the thermal uniformity on the wafer. First of all, the estimation method of one-point measurement is developed, which is properly extended to the case of multi-point measurements. This thermal model is validated through simulation and experiments. The proposed work can be utilized to building a run-by -run or a real-time control of the RTP.

  • PDF

강유전체 LiNbO$_3$ 박막/Si 구조의 제작 및 특성 (Fabrication of FerroelectricLiNbO$_3$ Thin Film/Si Structures aud Their properties)

  • 이상우;김채규;김광호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.21-24
    • /
    • 1997
  • Ferroeletric LiNbO$_3$ thin films hale been prepared directly on Si(100) substrates by conventional RF magnetron spurttering system for nonvolatile memory applications. As-deposited films were performed RTA(Rapid Thermal Annealing) treatment in an oxygen atmosphere at 600 $^{\circ}C$ for 60 s. The rapid thermal annealed films were changed to poly-crystalline ferroelectric nature from amorphous of as-deposition. The resistivity of the ferroelectric LiNbO$_3$ film was increased from a typical vague of 1~2$\times$10$^{8}$ $\Omega$.cm before the annealing to about 1$\times$10$^{13}$ $\Omega$.cm at 500 kV/cm and reduce the interface state density of the LiNbO$_3$/Si(100) interface to about 1$\times$10$^{11}$ cm$^2$ . eV. Ferroelectric hysteresis measurements using a Sawyer-Tower circuit yielded remanent polarization (Pr) and coercive field (Ec) values of about 1.2 $\mu$C/cm$^2$ and 120 kV/cm, respectively.

  • PDF

Rapid-to-deploy reconfigurable wireless structural monitoring systems using extended-range wireless sensors

  • Kim, Junhee;Swartz, R. Andrew;Lynch, Jerome P.;Lee, Jong-Jae;Lee, Chang-Geun
    • Smart Structures and Systems
    • /
    • 제6권5_6호
    • /
    • pp.505-524
    • /
    • 2010
  • Wireless structural monitoring systems consist of networks of wireless sensors installed to record the loading environment and corresponding response of large-scale civil structures. Wireless monitoring systems are desirable because they eliminate the need for costly and labor intensive installation of coaxial wiring in a structure. However, another advantageous characteristic of wireless sensors is their installation modularity. For example, wireless sensors can be easily and rapidly removed and reinstalled in new locations on a structure if the need arises. In this study, the reconfiguration of a rapid-to-deploy wireless structural monitoring system is proposed for monitoring short- and medium-span highway bridges. Narada wireless sensor nodes using power amplified radios are adopted to achieve long communication ranges. A network of twenty Narada wireless sensors is installed on the Yeondae Bridge (Korea) to measure the global response of the bridge to controlled truck loadings. To attain acceleration measurements in a large number of locations on the bridge, the wireless monitoring system is installed three times, with each installation concentrating sensors in one localized area of the bridge. Analysis of measurement data after installation of the three monitoring system configurations leads to reliable estimation of the bridge modal properties, including mode shapes.

A secondary development based on the Hoek-Brown criterion for rapid numerical simulation prediction of mountainous tunnels in China

  • Jian Zhou;Xinan Yang;Zhi Ding
    • Geomechanics and Engineering
    • /
    • 제34권1호
    • /
    • pp.69-86
    • /
    • 2023
  • To overcome the dilemma of the [BQ] method's inability to predict mountain tunnel support loads, this study is based on the Hoek-Brown criterion and previous results to obtain the connection equations from GSI scores to each parameter of the Hoek-Brown criterion and the link between the [BQ] scores and the GSI system. The equations were embedded in the Hoek-Brown criterion of FLAC6.0 software to obtain tunnel construction forecasts without destroying the in-situ stratigraphy. The feasibility of the secondary development of the Hoek-Brown criterion was verified through comparative analysis with field engineering measurements. If GSI > 45 with a confining pressure of less than 10 MPa, GSI has little effect on the critical softening factor while we should pay attention to the parameter of confining pressure when GSI < 45. The design values for each parameter are closer to the FLAC3D simulation results and the secondary development of the Hoek-Brown criterion meets the design objectives. If the Class V surrounding rock is thinned with shotcrete or the secondary lining is installed earlier, the secondary lining may act as the main load-bearing structure. The study may provide ideas for rapid prediction of mountainous tunnels in China.

영아 비후성 유문부 협착증에서 초음파 검사를 이용한 수술 후 유문부의 조기 변화 (Infantile Hypertrophic Pyloric Stenosis (IHPS) -Early postoperative changes of pylorus after pyloromyotomy using ultrasonogram in patients with IHPS-)

  • 백홍규;정풍만;김용수
    • Advances in pediatric surgery
    • /
    • 제5권1호
    • /
    • pp.64-68
    • /
    • 1999
  • The length, diameter and muscle thickness of the pylorus were measured by ultrasonograms in 15 infants with infantile hypertrophic pyloric stenosis(IHPS). These measurements were compared to assemble measurements of infants who came in for the routine vaccination and underwent ultrasonogram. This study also studied by ultrasound the changes in the pylorus of patients who underwent pyloromyotomy 4 weeks and 8 weeks postoperatively. According to $Carver^5$, the pyloric muscle volume(PMV) and pyloric muscle index(PMI) were calculated in each case. The pyloric muscle volume, PMI and the thickness of pyloric muscle proved to be a more reliable guide to diagnose IHPS than length and diameter of pylorus. The pyloric muscle length, diameter, thickness and pyloric muscle volume were not normalized at 4 and 8 weeks after pyloromyotomy. However, pyloric muscle index was normalized at 4 weeks postoperatively perhaps as the result of rapid weight gain after pyloromyotomy.

  • PDF

방사와 투과를 이용한 층류확산화염내 매연입자의 온도 및 농도 측정 (Soot Temperature and Concentration Measurement Using Emission/Transmission Tomography in Laminar Diffusion Flame)

  • 송상종;박성호;김상수
    • 대한기계학회논문집
    • /
    • 제17권10호
    • /
    • pp.2563-2573
    • /
    • 1993
  • The measurements of monochromatic line-of-sight flame emission and light transmission in the same path having small spatial resolution were performed in an axisymmetric laminar propane $C_{3}H_{8}$ diffusion flame. The light wavelengthes of 632 nm, 800nm, 900nm were used. From these measurements, local point soot radiances (by Kirchhoff's law) and absorption coefficients were reconstructed by tomography. Thus local point soot temperatures and concentrations were obtained. The reconstructed soot temperatures and concentrations of local points have no differences between the case of visible range (632 nm) and the case of infrared range (800 nm and 900 nm). In these ranges, the scattering coefficient is much lower than the absorption coefficient. Soot mean temperature over the path also matches well with local soot temperature in outer region of the flame. Temperature measurement by thermocouple with different bead diameters $(222{\mu}m and 308{\mu}m)$ was carried in the same flame. Rapid insertion technique was used and radiation effect was considered. Radiation correction in the sooting region was carried out and the corrected result was in good agreement with the local soot temperature.

넓은 당량비 구간에서 수소 함유량에 따른 합성가스(H2/CO)-공기 예혼합 화염의 층류연소속도에 관한 연구 (A study on the laminar burning velocity according to the H2 content variation in a large range of equivalence ratio of syngas(H2/CO)-air premixed flames)

  • 정병규;황철홍;이기만
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.215-218
    • /
    • 2012
  • In this study, syngas laminar burning velocities with various hydrogen contents were studied using both experimental measurements and kinetic simulations. The laminar burning velocities were measured by the angle method of Bunsen flame configuration and the numerical calculations including burning velocities were made using CHEMKIN Package with USC-Mech II. A large range of syngas mixture compositions such as 10:90%, 25:75%, 50:50%, 75:25% and equivalence ratio from lean condition of 0.5 to rich condition of 5.0 have been conducted. The experimental results of burning velocity were in good agreement with previous other research data and numerical simulation. Also, it was shown that the experimental measurements of laminar burning velocity linearly increased with the increasing of $H_2$ content although the flame speed of hydrogen is faster about ten times than carbon monoxide. This phenomenon is attributed to the rapid production of the hydrogen related radicals such as H and OH at the early stage of combustion, which is confirmed the linear increasing of radical concentrations on kinetic simulation.

  • PDF