• Title/Summary/Keyword: rapid extraction method

Search Result 329, Processing Time 0.035 seconds

Utility of solid phase extraction for colorimetric determination of lead in waters, vegetables, biological and soil samples

  • Al-Mallah, Zakia;Amin, Alaa S.
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.67
    • /
    • pp.461-468
    • /
    • 2018
  • A highly sensitive, selective and rapid method for the determination of lead based on the reaction of lead (II) with 5-(4'-chlorophenylazo)-6-hydroxypyrimidine-2,4-dione (CPAHPD) and the solid phase extraction of the Pb(II)-CPAHPD complex with Amberlite XAD-2000 was developed, in the presence of pH 5.6 buffer solution and Triton X-114 medium. CPAHPD reacts with lead to form a violet complex with a molar ratio of 2:1 (CPAHPD to lead). This complex was enriched by the solid phase extraction with Amberlite XAD-2000. An enrichment factor of 500 was obtained by elution of the complex from the resin with a minimal amount of isopentyl alcohol(0.2 mL). In isopentyl alcohol medium,the molar absorptivity of the complex is $1.13{\times}10^6L\;mol^{-1}cm^{-1}$ at 647 nm. Beer's law is obeyed in the range of $5.0-160ng\;mL^{-1}$ in the measured solution. The relative standard deviation for 10 replicate samples of $50ng\;mL^{-1}$ level is 1.26%. The detection and quantification limits reaches 1.5 and $4.7ng\;mL^{-1}$ in the original samples. The presented procedure was successfully applied for determination of lead content in real samples such as vegetables, waters, biological and soil samples with satisfactory results.

A Study on Strong Minutiae Extraction for Secure and Rapid Fingerprint Authentication

  • Han, Jin-Ho
    • International journal of advanced smart convergence
    • /
    • v.6 no.2
    • /
    • pp.65-71
    • /
    • 2017
  • Fingerprints are increasingly used for user authentication in small devices such as mobile phones. Therefore, it is important for Fingerprint authentication systems in personal devices to protect the user's fingerprint information while performing efficiently with a lightweight matching algorithm. In this paper, we propose a new method to extract strong minutiae with unique numbers from fingerprint images. Strong minutiae are at all times obtained from fingerprint images, and can be useful for secure and rapid fingerprint authentication. The binary information of strong minutiae of a fingerprint can be transformed securely and can create cancelable fingerprint templates. Also the bit-strings of strong minutiae decrease computing time necessary for the matching procedure between two fingerprints due to the simplicity of bitwise operations. First, we enroll several fingerprints images of a finger. From these images we select a reference fingerprint and put a number on each minutia. Following this procedure, we search for mated-minutiae between the reference fingerprint and other fingerprints one by one. Finally we derive unique numbers of strong minutiae of the finger. In the experiment with the FVC2004 fingerprint database, we show that using the proposed method, strong minutiae can be extracted successfully.

A Simple and Rapid Method to Isolate Low Molecular Weight Proteinase Inhibitors from Soybean

  • Krishnan Bari B.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.49 no.4
    • /
    • pp.342-348
    • /
    • 2004
  • Sodium dodecyl sulfate-polyacrylamide gel electrophoresis of the $60\%$ isopropanol extract of soybean(Glycine max [L.] Merr.) seed revealed two abundant proteins with molecular masses of 19 and 10 kDa. Amino acid analysis revealed that the isopropanol-extractable protein fraction was rich in cysteine. Two-dimensional gel electro-phoretic analysis indicated that the 19kDa and 10kDa proteins had pI of 4.2 and 4.0 respectively. Peptide mass fingerprints of trypsin digests of the two proteins obtained using matrix-assisted, laser desorption/ionization-time of flight (MALDI-TOF) mass spectroscopy revealed the 19kDa protein was Kunitz trypsin inhibitor and the 10kDa protein was Bowman-Birk proteinase inhibitor. When resolved under non-denaturing conditions, the isopropanol-extracted proteins inhibited trypsin and chymotrypsin activity. Results presented in this study demonstrate that isopropanol extraction of soybean seed could be used as a simple and rapid method to obtain a protein fraction enriched in Kunitz trypsin and Bowman-Birk proteinase inhibitors. Since proteinase inhibitors are rich in sulfur amino acids and are putative anticarcinogens, this rapid and inexpensive isolation procedure could facilitate efforts in nutrition and cancer research.

Process Development for Production of Antioxidants from Lipid Extracted Microalgae Using Ultrasonic-assisted Extraction (탈지미세조류로부터 초음파추출을 이용한 항산화 물질 생산 공정 최적화)

  • Jo, Jaemin;Shin, Suelgl;Jung, Hyunjin;Min, Bora;Kim, Seungki;Kim, Jinwoo
    • Korean Chemical Engineering Research
    • /
    • v.55 no.4
    • /
    • pp.542-547
    • /
    • 2017
  • Ultrasound-assisted extraction (UAE) has attracted growing interest, as it is an effective method for the rapid extraction of bioactive compounds from plants with a high extraction efficiency comparable to the conventional extraction. In this study, UAE was used for the extraction of polyphenols from lipid extracted microalgae (Tetraselmis KCTC 12236BP) and the effects of five extraction variables on the total phenolic compounds (TPC) were studied. For the optimization of extraction parameters, particle size, solid-to-liquid (L/S) ratio, ethanol concentration, extraction temperature and extraction time have been examined as independent variables. All variables exhibited the significant effects on the extraction of TPC and extraction temperature showed the most significant effect among five variables. The optimal extraction conditions were the extraction using mixed particle, S/L ratio of 10%, ethanol concentration of 60%, extraction temperature of $100^{\circ}C$ and extraction time of 30 min, which gave the 8.7 mg GAE/g DW for TPC. Compared with conventional hot-water extraction, TPC extraction under UAE was increased by up to 1.8 fold with same extraction condition. This study showed that UAE under low temperature and short extraction time was proven to be an effective extraction process for TPC production from LEA compared to conventional hot-water extraction process.

Application of Adsorption Sampling and Thermal Desorption with GC/MS Analysis for the Measurement of Low-Molecular Weight PAHs in Ambient Air (환경대기 중 저분자 PAHs 측정을 위한 흡착-열탈착-GC/MS 방법의 적용)

  • Seo, Seok-Jun;Seo, Young-Kyo;Hwang, Yoon-Jung;Jung, Dong-Hee;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.4
    • /
    • pp.362-377
    • /
    • 2014
  • Polycyclic aromatic hydrocarbons (PAHs) have been of particular concern since they are present both in the vapor and particulate phases in ambient air. In this study, a simple method was applied to determine the vapor phase PAHs, and the performance of the new method was evaluated with a conventional method. The simple method was based on adsorption sampling and thermal desorption with GC/MS analysis, which is generally applied to the determination of volatile organic compounds (VOCs) in the air. A combination of Carbotrap (300 mg) and Carbotrap-C (100 mg) sorbents was used as the adsorbent. Target compounds included two rings PAHs such as naphthalene, acenaphthylene, and acenaphthene. Among them, naphthalene was listed as one of the main HAPs together with a number of VOCs in petroleum refining industries in the USA. For comparison purposes, a method based on adsorption sampling and solvent extraction with GC/MS analysis was adopted, which is in principle same as the NIOSH 5515 method. The performance of the adsorption sampling and thermal desorption method was evaluated with respect to repeatabilities, detection limits, linearities, and storage stabilities for target compounds. The analytical repeatabilities of standard samples are all within 20%. Lower detection limits was estimated to be less than 0.1 ppbv. In the results from comparison studies between two methods for real air samples. Although the correlation coefficients were more than 0.9, a systematic difference between the two groups was revealed by the paired t-test (${\alpha}$=0.05). Concentrations of two-rings PAHs determined by adsorption and thermal desorption method consistently higher than those by solvent extraction method. The difference was caused by not only the poor sampling efficiencies of XAD-2 for target PAHs and but also sample losses during the solvent extraction and concentration procedure. This implies that the levels of lower molecular PAHs tend to be underestimated when determined by a conventional PAH method utilizing XAD-2 (and/or PUF) sampling and solvent extraction method. The adsorption sampling and thermal desorption with GC analysis is very simple, rapid, and reliable for lower-molecular weight PAHs. In addition, the method can be used for the measurement of VOCs in the air simultaneously. Therefore, we recommend that the determination of naphthalene, the most volatile PAH, will be better when it is measured by a VOC method instead of a conventional PAH method from a viewpoint of accuracy.

Mulberry Paper Bag μ-Solid Phase Extraction for the Analysis of Five Spice Flavors by Gas Chromatography-Mass Spectrometry

  • Yoon, Ok-Kyung;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.35-42
    • /
    • 2009
  • Headspace micro solid phase extraction using mulberry paper bag (HS-MPB-$\mu$-SPE) has been developed and validated for the analysis of volatile flavor compounds from five spice by gas chromatography-mass spectrometry (GC/MS). HS-MPB-$\mu$-SPE was performed with adsorbent particles enclosed inside a mulberry paper bag. Four different kinds of adsorbents such as Tenax TA, Porapack Q, dimethylpolysiloxane and polyethylene glycol were tested. The extraction solvents compared were petroleum ether, methylene chloride, and chloroform. Better results were obtained when Tenax TA and petroleum ether were used. The limit of detection (LOD) and the limit of quantitation (LOQ) were in the range of 1.3 ng/mL and 4.3 ng/mL, respectively, for o-cymene as a model compound of monoterpene. Proposed method showed good reproducibility (3.3%, RSD) and good recoveries (94.0%). The HS-MPB- μ-SPE is very simple to use, inexpensive, rapid, requires small sample amounts and solvent consumption. Because the solvent for extraction is reduced to only a very small volume (0.6 mL), there is minimal waste or exposure to toxic organic solvent and no further concentration step. This method allows successful characterization of the headspace in contact with the five spice sample. Strong trans-anethole from star anise or fennel is a characteristic flavor of five spice powders. HS-MPB-$\mu$-SPE combined with GC/MS can be a promising technique for the broad spectrum measurement of volatile aroma compounds from solid spices.

AUTOMATIC GENERATION OF BUILDING FOOTPRINTS FROM AIRBORNE LIDAR DATA

  • Lee, Dong-Cheon;Jung, Hyung-Sup;Yom, Jae-Hong;Lim, Sae-Bom;Kim, Jung-Hyun
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.637-641
    • /
    • 2007
  • Airborne LIDAR (Light Detection and Ranging) technology has reached a degree of the required accuracy in mapping professions, and advanced LIDAR systems are becoming increasingly common in the various fields of application. LiDAR data constitute an excellent source of information for reconstructing the Earth's surface due to capability of rapid and dense 3D spatial data acquisition with high accuracy. However, organizing the LIDAR data and extracting information from the data are difficult tasks because LIDAR data are composed of randomly distributed point clouds and do not provide sufficient semantic information. The main reason for this difficulty in processing LIDAR data is that the data provide only irregularly spaced point coordinates without topological and relational information among the points. This study introduces an efficient and robust method for automatic extraction of building footprints using airborne LIDAR data. The proposed method separates ground and non-ground data based on the histogram analysis and then rearranges the building boundary points using convex hull algorithm to extract building footprints. The method was implemented to LIDAR data of the heavily built-up area. Experimental results showed the feasibility and efficiency of the proposed method for automatic producing building layers of the large scale digital maps and 3D building reconstruction.

  • PDF

Determination of a histone deacetylase inhibitor SD-2007 by LC/MS and application to a pharmacokinetic study in rats

  • Shin, Beom-Soo;Yoon, Chi-Ho;Park, Min-Young;Jun, Yoon-Sik
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.310.1-310.1
    • /
    • 2003
  • SD-2007 ia an apicidin analogue, possessing a potent histone deacetylase inhibiting activity. A rapid and senstive LC/MS method was developed for the determination of SD-2007 and its major active metabolite. apicidin. in rat serum. SD-2007 and apicidin was extracted by liquid-liquid extraction using methyl t-butyl ether. SD-2007 and apicidin were monitored in a SIM mode at m/z of 679 and 622, respectively. (omitted)

  • PDF

Application of Solid Phase Microextraction to the Analysis of Pesticides in Vegetables

  • Cho Tae-Hee;Kang Hee-Gon;Kim Tae-Rang;Chang Min-Su
    • Proceedings of the Korean Society of Food Hygiene and Safety Conference
    • /
    • 2001.10a
    • /
    • pp.171-174
    • /
    • 2001
  • Solid phase micro-extraction (SPME), a solvent-free, rapid and inexpensive method for the extraction of organic compounds from aqueous sample matrices, was evaluated for determination of the 120 pesticides in vegetables such as crown daisy, perilla leaf, leafy lettuce and to mato. The analysis conditions were chosen for the SPME method: 15 min of immersion of the PDMS fiber in 10 ml of the solution with stirring at 1,000 rpm. The recovery tests were carried out in triplicate. The range of recoveries was 0-142% for organochlorine pesticides and $4.9\sim200\%$ for organophosphorus pesticides. The recoveries were very low in the pesticide groups with low solubility in water. The recoveries became lower in proportion to the interference materials in vegetables. The recovery in tomato was relatively higher than that in perilla Ie af and crown daisy. The recovery values obtained by SPE and SPME were compared. In leaf y lettuce, recovery obtained by SPE method ranged from $58.1\%\;to\;136.1\%$ and recovery by SPME ranged from $9.6\%\;to\;176.3\%$ In organophosphorus pesticides. The recovery in SPME method was satisfactory with $136\%$ for ethoprophos, $119\%$ for methidathion and $113\%$ for diazinon. Meanwhile, recovery of EPN, phenthoate and 2,4-DDT revealed relatively low value of $38\%,\;41\%\;and\;3.4\%,$ respectively. However, most of pesticides applied to SPME method sho wed constant recovery and precision. From these results, it can be concluded that solid phase micro-extraction might be an appropriate method for the screening test of pesticides in vegetables.

  • PDF

Development Rapid Analytical Methods for Inositol as a Trace Component by HPLC and LC-MS/MS in Infant Formula

  • Shin, Jin-Ho;Park, Jung-Min;Kim, Ha-Jung;Ahn, Jang-Hyuk;Kwak, Byung-Man;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.35 no.4
    • /
    • pp.466-472
    • /
    • 2015
  • A rapid and simple analytical method, using liquid chromatography tandem mass spectrometry (LC-MS/MS), was developed to detect myo-inositol (MI) in infant formulas. For protein removal: acid hydrolysis and lipid removal through organic solvent extraction. The operating conditions for instrumental analysis were determined based on previously reported analogous methods that used LC-MS/MS. Quantitative analysis was used for the detection limit test, infant formula recovery test, and standard reference material (SRM) 1849a to verify the validity of our LC-MS/MS analytical method, which was developed to quantify MI. For validation, the results of our method were compared with the results of quantitative analyses of certified values. The test results showed that the limit of detection was 0.05 mg/L, the limit of quantitation was 0.17 mg/L, and the method detection limit was 17 mg/kg. The recovery test exhibited a recovery between 98.07-98.43% and a relative standard deviation between 1.93-2.74%. Therefore, the result values were good. Additionally, SRM 1849a was measured to have an MI content of 401.84 mg/kg and recovery of 98.25%, which is comparable to the median certified value of 409 mg/kg. From the aforementioned results, we judged that the instrumental analysis conditions and preparation method used in this study were valid. The rapid analytical method developed herein could be implemented in many laboratories that seek to save time and labor.