• Title/Summary/Keyword: range of numbers

Search Result 814, Processing Time 0.03 seconds

Numerical investigation of the recirculation zone formed downstream of a back ward facing step

  • Sarker, Konica;Ali, Mohammad;Cho, Haeng Muk;Mahmud, Md. Iqbal
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.110-114
    • /
    • 2015
  • A numerical investigation has been carried out on recirculation zone formed downstream of a compressible flow over a backward facing step. The study has been performed by solving Two-Dimensional Navier-Stokes equations. The system of governing equations has been solved, using an explicit Harten-Yee Non- MUSCL Modified flux type TVD scheme and a zero-equation algebraic turbulence model to calculate the eddy viscosity coefficient. The recirculation region dimensions are characterized over a range of Mach numbers of fixed step height 5mmThe detail of recirculation zone such as pressure, temperature, recirculation length, strength etc are reported. The variations of these characteristics due to change of Mach number are also presented.

The Characteristics of Wide-Band/Wide-Scan E-plane Notch Phased Array Antenna

  • Kim, Jun-Yeon;So, Joon-Ho;Lee, Moon-Que;Cheon, Chang-Yul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.5
    • /
    • pp.194-198
    • /
    • 2003
  • A wide-band E-plane notch phased array antenna having bandwidths of 3:1 and a scan volume of $\pm$ 45 is designed considering the active element pattern (AEP) with analysis of the full structure of E-plane notch phased array antenna. Using the numerical E-plane waveguide simulator as an infinite linear array in the broadside angle, the active reflection coefficient (ARC) of the unit element is optimized in the design frequency range. To evaluate the convergence of the AEP, the simulation of full array as changing the number array is investigated, and the minimum numbers of array that have characteristics similar to the AEP of an infinite array are determined.

Heat Transfer and Friction in Rectangular Convergent Channels with Ribs on One Wall

  • Kim, Won-Cheol;Lee, Myung-Sung;Bae, Sung-Taek;Ahn, Soo-Whan
    • Journal of Power System Engineering
    • /
    • v.18 no.2
    • /
    • pp.12-18
    • /
    • 2014
  • The local heat transfer of developed turbulent flows in the stationary ribbed rectangular convergent channels has been investigated experimentally. The rectangular convergent channels with one ribbed surface only have the inclination of $0.72^{\circ}$ and $1.43^{\circ}$ at which the ribbed wall is manufactured with a fixed rib height (e) of 10 mm and the ratio of rib spacing (p) to height (e) =10. The measurement was conducted within the range of Reynolds numbers from 15,000 to 89,000. The local heat transfer characteristics of the rectangular convergent channels are quite different from those of the ribbed square straight channel.

Distribution of Fungi in the Sandy Soil of Egyptian Beaches

  • Migahed, Fatma F.
    • Mycobiology
    • /
    • v.31 no.2
    • /
    • pp.61-67
    • /
    • 2003
  • The mycobiota of the sandy soil of Egyptian beaches was investigated in thirty six sand samples collected from nine different localities in Egypt. The filamentous fungi were identified and assigned to thirty one genera and fifty one species. Greater populations as well as a wider spectrum range of fungal genera and species were obtained in sandy soil of Alexandria beach while Balteem beach was the poorest one. The total count of the genus or species was not depended upon cases of isolation. Most of the genera detected belonged to the Deuteromycotina with fewer proportions belonging to the Ascomycotina and Zygomycotina. The genera of highest incidence and their respective numbers of species were: Penicillium(35.72%, 6 species) and Aspergillus(30.28%, 16 species). The species which showed the highest incidence in all cases was P chrysogenum, followed by P citrinum, A. flavus, Chaetomium murorum and Trichoderma viride. A few number of other genera and species were also detected.

Effects of the Water Extract of Akebia (Akebia quinata Edcaisne) on the Growth of Clotridium perfringens and Some Intestinal Microorganisms (목통 (Akebia quinata Decaisne)의 물추출물이 Clostridium perfringens 및 주요 장내미생물의 생육에 미치는 영향)

  • 한복진;우상규;신현경
    • Microbiology and Biotechnology Letters
    • /
    • v.23 no.6
    • /
    • pp.633-640
    • /
    • 1995
  • As a result of screening the medicinal herbs which selectively control human intestinal microflora, water extract of Akebia quinata Decaisne was proved to have a strong inhibitory activity against the growth of Clostridium pefringens, a major harmful intestinal bacterium. The anti-bacte-rial activity was stable under the thermal treatment at 100$\circ$C for 120 min and in a range of pH 1 to 11. In addition, the water extract of Akebia quinata Decaisne showed the antibacterial activities against five different strains of Clostridia including C. perfringens. On the contrary, the extract did not inhibit the growths of Bifidobacterium, Lactobacillus, Escherichia coli, Enterococcus faecalis. The extract, however, suppressed markedly the growth of Bacteroides fragilis and Staphylococcus aureus in vitro. Alike in the mixed culture inoculated with human feces as starter, in vivo tests using rats showed that the extract tends to increase the numbers of Bifidobacteria and Lactobacilli in the intestinal microflora of rats, whereas those of Clostridia were attenuated.

  • PDF

An experimental study on the reattachment of Non-Newtonian fluid flows in a sudden expansion pipe (돌연 확대관에서 비뉴우튼 유체의 재접착 실험)

  • 전운학;이행남
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.15 no.1
    • /
    • pp.45-54
    • /
    • 1993
  • The reattachment lengths of the Non-Newtonian fluid are investigated in the sudden expansion pipes whose ratios are 2.316 and 3.368, and the range of the Reynolds numbers is 100-30000. The reattachment lengths for the viscoelastic fluid in the laminar flow region are found to be much shorter than those of the Newtonian fluid, and decrease significantly with the increase of the concentration of viscoelastic fluid is two or three times longer than those of water, and gradually increases with the increase of the concentration of viscoelastic fluid.

  • PDF

An Experimental Study on Heat Transfer Characteristics of a Thermal Diode Type Enclosure with a Guide Vane

  • Kim, Suk-Hyun;Jang, Young-Keun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.4
    • /
    • pp.10-16
    • /
    • 2001
  • An experimental study for free convective heat transfer in a thermal diode type enclosure is presented. The thermal diode is a device which allows heat to be transferred in one direction by convection due to density difference of the fluid, and consists of a rectangular-paralle-logrammic enclosure with a guide vane. It is used as heat collection system of solar energy due to its simple construction and low cost. Experimental parameters were guide vane thickness, the inclination angles of the parallelogrammic enclosure, and the lengths of the rectangular enclosure part. The parameter range of the flux Rayleigh numbers was $2.4\times{10}^8$~$9.8\times{10}^8$. The heat transfer rate of this system was shown 10~47% higher than that of other earlier research results without the guide vane. The correlation for fixed $\phi=60^\circ$ was obtained, Nu=0.0037(Ra^*)^{0.429}(d^*)^ {0.050}(Lr/H)^{0.0415}$.

  • PDF

Community Attachment of Residents and Its Related Variables (지역사회주민의 지역사회 친밀도와 관련 변인)

  • Yoon, Jun-Sang;Choi, Chang-Wook
    • Journal of Agricultural Extension & Community Development
    • /
    • v.5 no.1
    • /
    • pp.113-122
    • /
    • 1998
  • Community Attachment variables(specially, system model variables : gender, age, education, income, number of children, marital status, length of residence, and job) have been tested. The data for this study were collected from 295 residents of Yesan in Chungnam. The SPSSWIN package was utilized for data analysis. Frequency, percent, t-test, and ANOVA were utilized for statistical analysis. Each hypothesis was tested at .01, .05, and 01 level. The major findings of this study were: 1) the range of community attachment score was $17{\sim}56$. The mean score of community attachment was 29.8 with a standard deviation of 5.34. 2) t-test showed that job was statistically significant at .05 level among gender, marital status, and job. 3) length of residence, age, and numbers of children were statistically significant at .05, .10, and .01, respectively.

  • PDF

Evaluation on Thermal Energy Performance of a Plate Heat Exchanger (판형열교환기의 열에너지 성능평가)

  • Kang, Byung-Ha;Kim, Do-Kyu
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2003
  • Performance evaluation on thermal transport of a plate heat exchanger has been carried out. The $\varepsilon$-Ntu method is employed to evaluate the performance of a brazed type of plate heat exchanger. This problem is of particular interest in the design of a plate heat exchanger. The characteristics of heat transfer as well as pressure drop are studied in the wide range of Reynolds numbers in the cold side while that of hot side is fixed at 620. f-factor correlation in a plate heat exchanger is obtained from the pressure drop data. It is also found that the effectiveness of the plate heat exchanger is increased as the Ntu is increased.

A study on solutions of Jisuguimundo using the range of magic sums (합의 범위를 이용한 지수귀문도 해의 탐구)

  • Kwon, Gyunuk;Park, Sang Hu;Song, Yun Min;Choi, Seong Woong;Park, Poo-Sung
    • Journal for History of Mathematics
    • /
    • v.27 no.2
    • /
    • pp.111-125
    • /
    • 2014
  • Jisuguimundo is an inimitable magic hexagon devised by Choi Seok-Jeong, who was the author of GuSuRyak as well as a prime minister in Joseon dynasty. Jisuguimundo, recorded in GuSuRyak, is also known as Hexagonal Tortoise Problem (HTP) because its nine hexagons resemble a tortoise shell. We call the sum of numbers in a hexagon in Jisuguimundo a magic sum, and show that the magic sum of hexagonal tortoise problem of order 2 varies 40 through 62 exactly and that of hexagonal tortoise problem of order 3 varies 77 through 109 exactly. We also find all of the possible solutions for hexagonal tortoise problem of oder 2.