• Title/Summary/Keyword: range of contamination

Search Result 444, Processing Time 0.028 seconds

The Changes on Total Bacterial Counts and Coliform Counts of Human Milk vs Formula Milk Stored under Cold and Room Temperature Conditions (냉장 및 실온 보존에 따른 모유와 환원조제분유 중의 총균수와 대장균수의 변화)

  • Lee, Jo-Yoon;Bae, Hyoung-Churl
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.3
    • /
    • pp.433-437
    • /
    • 2002
  • Human milk is normally contaminated with various microorganisms, which seem to produce no ill effects. A contamination of hand-expressed and pump-expressed human milk is a major concern in the collection of storage milk. In this study we compared milks collected by two methods, hand expression and suction breast pump, to quantify differences in the degree of bacterial contamination. Thirty-one samples had been manually expressed. The mean of total bacterial counts was 10,600 CFU/mL (range: 360 ∼59,200 CFU/mL) and coliform counts was 43 CFU/mL (range: 20 ∼ 1,060 CFU/mL) in these samples. Whereas in the 118 breast pump-expressed samples, the mean of total bacterial counts was 20,200 CFU/mL (range: 240 ∼ 492,000 CFU/mL) and coliform counts was 158 CFU/mL (range: 4∼10,600 CFU/mL). There was no bacterial growth when the samples were incubated for 10 days at 4$\^{C}$. We also compared total bacterial growth in colostrum and in matured human milk for 24 hr at 20$\^{C}$ and 30$\^{C}$. Although bacterial growth had not shown for 24 hr at 20$\^{C}$, but shown slight growth in colostrum and rapidly increase in matured human milk for 24 hr at 30$\^{C}$. The coliform bacteria in all samples, particulary in formula milk, had grown at 20$\^{C}$ and 30$\^{C}$.

Extraction Characteristics and Quantitational Methods for Total Petroleum Hydrocarbons in Soil

  • Jeon, Chi-Wan;Lee, Jung-Hwa;Song, Kyung-Sun;Lee, Sang-Hak;Lee, Jung-Min
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.119-122
    • /
    • 2003
  • Quantitation methods of total petroleum hydrocarbons to determinate oil contaminated level in soil were discussed. Extraction characteristics of several pretreatment methods and practical detection limit and reappearances in gas chromatography/mass spectrometry. with each pretreatment method were investigated. The obtained results showed that the newly adopted quantitation method and mechanical shaking extraction method using methanol with extraction solvent are more practical and applicable to real sample than the conventional methods. In applying these methods to gasoline, kerosene, fuel oil which are major source of soil contamination, the practical quantitation limit and % relative standard deviation was able to determine with range of 2.5 - 10 ppm, 5 - 7 %.

  • PDF

동위원소를 이용한 폐금속광산 지역 오염원 추적 연구

  • Yeom Seung-Jun;Lee Pyeong-Gu;Lee In-Gyeong;Lee Uk-Jong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.209-212
    • /
    • 2006
  • Using sulfur sotope analysis of dissolved sulfate in surface water, we have investigated the source of sulfate in order to identify the abandoned metallic mines, which have the potential of heavy metal contamination within watershed. The range of the sulfur isotope values for dissolved sulfate in stream waters (DD-1 and 2) are similar to those of sulfides from the Dunjun mine, which suggests that oxidation of sulfides is the principal source of $SO_4^{2-}$ in these stream waters. Also, heavier sulfur isotopes in waters near Baekjun and Hamchang mines imply the possibility of contamination in waters by these metallic mines.

  • PDF

기름 유출로 인한 토양 및 지하수의 오염

  • Kim Dong-Jin;Yang Jae-Eui;Yu Jin-Yeol;Kim Hui-Gap;Kim Gi-Dong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.424-427
    • /
    • 2006
  • Soil contamination with petroleum oil around a military army was investigated. It showed that soils of a riverside highland, an entrance of the military army, and nearby roads were contaminated with total petroleum hydrocarbons (TPH) released from the military army to the depth of approximately 2 m. The measured concentrations were as high as 15,277 mg/kg. A wide range of soil in the riverside highland was contaminated by the movement of oil to the surface soil, which occurred with the vertical movement of groundwater table caused by the change of river water level and groundwater level. Spilled petroleum oil components were released into Wonju Stream by the increase of hydraulic conductivity and the groundwater flow.

  • PDF

영산강 하상퇴적물의 중금속 함량

  • 조영길;김주용
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.281-290
    • /
    • 1998
  • Thirty-eight sediment samples collected from the Youngsan River channel were analysed for Fe, Mn, Co, Cr, Cu, Nl, Zn and Pb to recognize the extent of contamination. Results showed that a wide range of contents was apparent far every metal over the study area. These differences have been mainly related to the textural variability of sediments. Exceptions to this were fecund in the contents of Cu, Zn, Pb and possibly Mn. The contents of Cu, Zn, Pb and Mn were particularly higher in the sediments loom the confluence of tributaries. Downstream profile of metal/Al ratios indicates that pollutant inputs from the Kwangju tributary are mainly responsible for enrichment of these metals in bed sediments of the Young-san River.

  • PDF

Streaming potential and groundwater contamination

  • Baker Simon S.;Cull James P.
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.1
    • /
    • pp.41-44
    • /
    • 2004
  • Measurements of streaming potential can provide a means for the detection and quantification of contaminants in groundwater prior to remediation. However, laboratory determinations of specific electrolyte properties are required for an adequate analysis of the hydraulic gradient in complex situations. Data obtained for the King River in Tasmania confirm a linear relationship linking streaming potential data and hydraulic gradients. Laboratory samples at low concentration (0.001M KCl) indicate values in the range 20-80 mV/cm of water pressure, while for higher concentrations (0.01M KCl) values are less than 25 mV/cm. Similar ion concentrations are observed in the King River, consistent with field correlations indicating values for streaming potential close to 15 mV/cm. In-situ fluid samples are required for more detailed analysis of local anomalies that may be associated with variations in recharge and migration of contaminants.

An Experimental Study on the Measurement of Soot Contamination in a Diesel Engine Oil (디젤 엔진오일 내 Soot 함량 증가에 따른 오염도 측정에 관한 실험적 고찰)

  • 공호성;조성용;윤의성;한흥구;정동윤
    • Tribology and Lubricants
    • /
    • v.19 no.5
    • /
    • pp.251-258
    • /
    • 2003
  • New method and device for the on-line measurement of soot concentration in a diesel engine oil are proposed, where the measurement principle is based mainly on attenuated internal total reflection. The detector were evaluated in various ranges of contaminated oils by carbon black particles. It was found that the proposed detector could be well used to monitor the oil deterioration due to soot contamination. Operational range of the detector was found from 0 to 5 mass percentage of soot content. Test results with water and fuel dilution showed that these effects were not remarkable. However, adsorption of carbon black particles onto the measurement surface was considered to be a critical problem of the detector. Effects of particle deposition on the interface was experimentally evaluated with the oil temperature and flow turbulence and discussed throughout this work.

Fluoride Contents of River Water and Industrial Waste Water in Seoul (서울市內 河川水 및 工場排水中의 플루오르 含量)

  • Whang, Kyu-Ja
    • Journal of the Korean Chemical Society
    • /
    • v.12 no.4
    • /
    • pp.163-169
    • /
    • 1968
  • The analysis for the fluoride contents of river water and industrial waste water in Seoul area has been carried out by the spectrophotometric method, from February to July, 1968. The results show that the average fluoride contamination is found to be in the range of $0.07{\pm}0.03{\sim}0.29{\pm}0.05$ mg/l. The reason for this contamination is discussed in detail.

  • PDF

Effect of Water Contamination of the Lubricant and Surface Roughness of Bearing Steel on the Rolling Contact Fatigue Life (윤활유의 수분혼입 및 베어링강의 표면 조도가 구름접촉 피로수명에 미치는 효과)

  • Heo, Tae Hyeon;Sim, Chung-Ki;Kim, Hong Seok;Shin, Ki-Hoon;Cheong, Seong Kyun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.15-20
    • /
    • 2017
  • A large amount of research has been performed on the rolling contact fatigue(RCF) life of bearings, since it directly affects the safety and reliability of mechanical systems. It is well known that rolling contact fatigue life is influenced by several parameters including contact pressure, oil contamination by water or metal particles, and the surface conditions of bearings. However, the detailed damage mechanisms involved in rolling contact fatigue have not been clearly identified yet. In this paper the effects of water contamination of the lubricant and surface roughness of bearing steel on the rolling contact fatigue life were investigated. Two types of specimens with different surface roughness values were prepared through turning and lapping operations. They were tested under two different lubrication conditions, i.e. oil lubricant with 100% of oil and the water contaminated condition with 80% of oil and 20% of water using the rolling contact fatigue testing machine. The surface damage induced by the rolling contact fatigue was observed by using atomic force microscope(AFM). Experimental results show that the rolling contact fatigue life, $L_{10}$ was reduced by 24 to 33% depending on the lubrication condition. The reduction of fatigue life in the range of 53 to 57% was also observed at different surface roughness conditions.

The impact of municipal waste disposal of heavy metals on environmental pollution: A case study for Tonekabon, Iran

  • Azizpour, Aziz;Azarafza, Mohammad;Akgun, Haluk
    • Advances in environmental research
    • /
    • v.9 no.3
    • /
    • pp.175-189
    • /
    • 2020
  • Municipal solid waste disposal is considered as one of the most important risks for environmental contamination which necessitates the development of strategies to reduce destructive consequences on the ecosystem as related especially to heavy metal accumulation. This study investigates heavy metal (i.e., As, Cd, Co, Cr, Cu, Mn, Ni, Pb, Zn) accumulation in the Tonekabon region, NW of Iran that is related to city waste disposal and evaluates the environmental impact in the Caspian Sea coastal region. For this purpose, after performing field studies and collecting 50 soil specimens from 5 sites of the study area, geochemical tests (i.e., inductively coupled plasma mass spectrometry, atomic absorption spectroscopy and x-ray fluorescence) were conducted on the soil specimens collected from the 5 sites (named as Sites A1, A2, A3, A4 and A5) and the results were used to estimate the pollution indices (i.e., geo-accumulation index, normalized enrichment factor, contamination factor, and pollution load index). The obtained indices were utilized to assess the eco-toxicological risk level in the landfill site which indicated that the city has been severely contaminated by Cu, Mn, Ni, Pb and Zn. These levels have been developed along the stream towards the nearshore areas indicating uptake of soil degradation. The heavy metal contamination was classified to range from unpolluted to highly polluted, which indicated serious heavy metal pollution in the study area as related to municipal solid waste disposal in Tonekabon.