• 제목/요약/키워드: range measurement

검색결과 4,354건 처리시간 0.035초

Four Degree-of-Freedom Geometric Error Measurement System with Common-Path Compensation for Laser Beam Drift

  • Qibo, Feng;Bin, Zhang;Cuifang, Kuang
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권4호
    • /
    • pp.26-31
    • /
    • 2008
  • A precision four-degree-of-freedom measurement system has been developed for simultaneous measurement of four motion errors of a linear stage, which include straightness and angular errors, The system employs a retro-reflector to detect the straightness errors and a plane mirror to detect the angular errors. A common-path compensation method for laser beam drift is put forward, and the experimental results show that the influences of beam drift on four motion errors can be reduced simultaneously. In comparison with the API 5D laser measuring system, the accuracy for straightness measurement is about ${\pm}1.5{\mu}m$ within the measuring range of ${\pm}650{\mu}m$, and the accuracy for pitch and yaw measurements is about ${\pm}1.5$ arc-seconds within the range of ${\pm}600$ arc-seconds.

정밀전압, 전류, 전력측정 다기능전력계 (Multi-function Wattmeter for Voltage, Current, and Power Measurement)

  • 박영태;유권상;장석명
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권10호
    • /
    • pp.568-572
    • /
    • 2002
  • High precision voltages, currents, and electrical power measurements in wide range of frequency can be achieved by using the thermo-elements(thermal converters). This paper describes a development wattmeter, based on a thermal principle. The instrument has been performed measurement in the range of currents from 0 to 50 A, voltages up to 480 V, power factor 0.5 (lag, lead), 1 and frequencies from 60 Hz to 3 KHz. It is intended to be used by electric utilities, standard laboratories, testing laboratories, and applications where high measurement accuracy are attractive consideration.

수치근접사진측량에 의한 고해상도 디지털 카메라의 석재표면 거칠기 측정정확도 파악 (Analysis of Stone′s Surface Roughness Measurement Accuracy of a High Resolution Digital Camera by Digital Close-Range Photogrammetry)

  • 안기원;이효성;유주현
    • 한국측량학회지
    • /
    • 제18권2호
    • /
    • pp.135-141
    • /
    • 2000
  • 본 연구에서는 수치근접사진측량기법에 의한 DCS 420 디지털 카메라의 석재표면 거칠기 측정정확도 파악을 위하여 윈도우 환경의 Microsoft Visual basic 6.0으로 표면거칠기측정시스템을 구축하였다. 본 시스템을 통하여 거칠기가 거의 없는 이상적인 평면과 곡면인 돌의 표면 거칠기를 최소제곱법으로 기준면을 적용, 측정한 결과 $\pm$0.1 mm이하의 정확도로 측정할 수 있었다.

  • PDF

어깨관절의 수동적 내회전 관절 가동범위의 측정 방법에 따른 신뢰도와 상완골두의 전방 활주 거리 비교 (A Comparison of Reliability and Anterior Glide Distance of Humerus Head of Passive Shoulder Internal Rotation Range of Motion Measurement Methods)

  • 김현숙;이원휘;정성대
    • 한국전문물리치료학회지
    • /
    • 제17권3호
    • /
    • pp.1-10
    • /
    • 2010
  • The purpose of this study was to measure intra-rater and inter-rater reliability and range of motion for measurement of passive shoulder internal rotation range of motion and to compare anterior glide distance of humeral head in three methods. Fifty healthy subjects and fifty patients with shoulder musculoskeletal pain were recruited for this study. The subjects' passive shoulder internal rotation range of motion was measured by visual estimation, manual stabilization, and pressure biofeedback unit methods. In two trials, measurements were performed on each subject by two examiners. Intraclass correlation coefficient (ICC(3,1)) was used to determine the reliability of each measurement. The intra-rater reliability of the three methods was excellent (ICC=.77~.93) in both groups. The inter-rater reliability of the visual estimation method was poor (ICC=.20, .29), the manual scapular stabilization method was poor and fair (ICC=.09, .50), and the pressure biofeedback unit method was excellent (ICC .86, .75) in the experimental and control groups. In the experimental group, the difference of examined range of motion by each examiner was significant in the visual estimation method and manual scapular stabilization method, but there was an insignificant difference between the groups is the pressure biofeedback unit method. This result suggests that the intra-rater and inter-rater reliability of a pressure biofeedback unit was better than the other methods. The difference in distance of the anterior glide of humeral head was insignificant among all the methods. The pressure biofeedback unit method was the most reliable method, so it is proposed to be a new and reliable method to measure internal rotation range of motion.

Difference in Muscle Activity of Deltoid Muscle according to Isokinetic Range of Motion Using Proprioceptive Neuromuscular Facilitation Pattern of Upper Extremity

  • Rhee, Min-Hyung;Choi, Su-Hong;Lee, Sang-Yeol;Ha, Kyung-Jin;Yoon, Sung-Young
    • The Journal of Korean Physical Therapy
    • /
    • 제34권5호
    • /
    • pp.278-281
    • /
    • 2022
  • Purpose: This study sought to compare the muscle activity of the deltoid muscle according to the range of motion during the proprioceptive neuromuscular facilitation (PNF) upper extremity D2 pattern exercise performed with an isokinetic exercise device. The aim was to provide basic data for selecting an exercise for the relevant segment of the range of motion to enhance function in clinical practice. Methods: In this study, the relevant measurements of the anterior and middle trapezius of 25 healthy adults were taken using a surface electromyography system. The upper extremity pattern exercise was performed in three ranges (0% to 50%, 50% to 100%, and 25% to 75%) using the upper extremity isokinetic device. Results: There was a statistically significant difference in the muscle activity ratios of the anterior and middle deltoid muscles according to the measurement conditions (p<0.05). There was a statistically significant difference in the activity ratio of the middle deltoid muscle according to the measurement conditions in the ratio from the start range to the end range (p<0.05). There was no significant difference in the muscle onset time difference according to the measurement conditions (p>0.05). Conclusion: The muscle activity of the anterior and middle deltoid muscles was analyzed according to the range of motion during the PNF upper extremity pattern exercise performed with an isokinetic device. The results could be used as a basis for selecting exercises for the relevant segment of the range of motion according to the function to be emphasized.

The Immediate Effect of Wrist Joint Mobilization with Taping on Range of Motion, Grip Strength, Spasticity in Stroke Patients

  • Park, Shin-Jun;Youn, Pong-Sub
    • The Journal of Korean Physical Therapy
    • /
    • 제29권4호
    • /
    • pp.187-193
    • /
    • 2017
  • Purpose: The purpose of this study was to confirm the immediate effect of wrist joint mobilization with taping on the range of motion, grip strength, and spasticity. Methods: Thirty stroke patients were randomly divided into two groups: the joint mobilization with taping group (n=15) and a taping group (n=15). For measurement of spasticity and joint range of motion, the modified Tardieu scale, active and passive range of motion of wrist flexion, as well as extension were measured by the Rapael smart glove, and for grip strength measurement, grip dynamometer was performed. Results: The experimental group showed a significant improvement in the range of motion, grip strength, and spasticity after 10 minutes of taping (p<0.05), no significant difference was found in the control group (p>0.05). However, there was no significant difference between the two groups (p>0.05). Conclusion: The study found that wrist joint mobilization with taping has an immediate effect on wrist range of motion, grip strength, and spasticity in stroke patients, whereas it was not effective in the control group with just taping. The long-term change still needs to be evaluated, when taking into consideration of the carryover effect.

복부 움직임에 따른 초음파 근접센서를 이용한 호흡측정에 관한 연구 (Abdominal Wall Motion-Based Respiration Rate Measurement using An Ultrasonic Proximity Sensor)

  • 민세동;김진권;신항식;윤용현;이충근;이정환;이명호
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.2071-2078
    • /
    • 2009
  • In this paper, we proposed a non-contact respiration measurement system with ultrasonic proximity sensor. Ultrasonic proximity sensor approach of respiration measurement which respiration signatures and rates can be derived in real-time for long-term monitoring is presented. 240 kHz ultrasonic sensor has been applied for the proposed measurement system. The time of flight of sound wave between the transmitted signal and received signal have been used for a respiration measurement from abdominal area. Respiration rates measured with the ultrasonic proximity sensor were compared with those measured with standard techniques on 5 human subjects. Accurate measurement of respiration rate is shown from the 50 cm measurement distance. The data from the method comparison study is used to confirm the performance of the proposed measurement system. The current version of respiratory rate detection system using ultrasonic can successfully measure respiration rate. The proposed measurement method could be used for monitoring unconscious persons from a relatively close range, avoiding the need to apply electrodes or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using ultrasonic sensor offers a promising possibility of non-contact measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range of the measurement and quality of the rate-finding for broadening the potential application areas of this technology.

미소변위 측정용 전기용량변환기 개발에 관한 연구 (A Study on the Development of Capacitive Transducer for Measurement of Small Displacement)

  • 박영태;이래덕
    • 대한전자공학회논문지
    • /
    • 제24권5호
    • /
    • pp.762-768
    • /
    • 1987
  • The capacitive transducers, which are used of the principle of capacitance changes by means of the variation of distance between electrodes, are usually utilized for measurement of small displacements. But the measurement ranges of this method are limited. In this study, the measurement ranges are extended by using the variation method of the surface area of electrodes. Thus the capacitive transducer and signal conditioner, which are having the capability of measurement range of 25mm and resolution of 0.1\ulcorner, have developed, and its environmental characteristics are also tested.

  • PDF

Introduction On the Importance of Engineering Survey in Project Management

  • Meng, Yanlei;Chen, Guiming
    • 국제학술발표논문집
    • /
    • The 7th International Conference on Construction Engineering and Project Management Summit Forum on Sustainable Construction and Management
    • /
    • pp.260-262
    • /
    • 2017
  • During the construction of the project, all surveying and mapping work is collectively referred to as engineering survey. Therefore, the measurement work contains a wide range of content, in the engineering survey, design and construction management stage are involved. To the actual work, the project measurement runs through the project building in a number of stages, and provide basic services. This paper mainly through the analysis of engineering measurement at all stages of the role played by the measurement work in the project management work to do the following description.

  • PDF