• Title/Summary/Keyword: range detection circuit

Search Result 79, Processing Time 0.028 seconds

A Study on the Position Detection Device for a Hybrid Type Linear Pulse Motor (HB형 LPM의 위치검출장치에 관한 기초연구)

  • 신춘식;김남호;노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.31-36
    • /
    • 1996
  • In recent years, as the electonic industry has become more advanced, the LPM(Linear Pulse Motor) has appeared in a wide range of applications because of easier control, operation by open-loop control, high positioning accuracy, and retrieval of position or velocity data by the input pulses. In this study, we deal with the development of a position detection device attached to a hybrid LPM in our laboratory. Precise position detection signals could be sensed by the synchronous rectifier method from the LPM stator scale. In addition, we can keep the amplitude constant by using an AGC(Automatic Gain Control) circuit. Experimental results show that the position data is good enough to perform the LPM position control.

  • PDF

A Study of Noncontact Heartbeat and Respiration Detection Using the Doppler Radar (도플러 레이더를 이용한 비접촉 방식의 심박 및 호흡 검출에 관한 연구)

  • Shin, Jae-Yeon;Cho, Sung-Pil;Jang, Byung-Jun;Park, Ho-Dong;Lee, Yun-Soo;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • In this paper, a 2.4 GHz doppler radar system consisting of a doppler radar sensor and a baseband module were designed to detect heart beat and respiration signal without direct skin contact. The doppler radar system emits RF signal of 2.4 GHz toward human chest, and then detects phase modulation of the reflected signal so as to investigate cardiopulmonary activities. The heartbeat and respiration signals acquired from I/Q channels of the doppler radar system are applied to the pre-processing circuit, the amplification circuit, and the offset circuit of the baseband module. The designed system was tested on mouse, rabbit and mankind, which have different range of heart rates and respiration signals, to evaluate detection accuracy of the system. ECG acquisition system and respiration transducer were used to generate the reference signal. In our experiments, a performance of detection were found to be high in the case that the subject stays still. In this paper, we confirmed that non-contact heart beat and respiration detection using the doppler radar has the possibility and limitation according to distance, cardiopulmonary activities, range of heart rates and respiration.

Low-Power Design Scheme of Protection IC for Multi-Cell Configurations (다중셀 구조의 보호회로 IC의 저전력 설계기법)

  • 이종훈;조충현;김대정;민경식;김동명
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1217-1220
    • /
    • 2003
  • A low-power design technique for lithium-ion Battery-Protection Integrated Circuit (BPIC) for multi cell configuration is proposed. The hardware sharing scheme with more precisely divided operating states in the detection range could reduce the power consumption significantly, especially during the normal state. The usefulness of the proposed scheme was confirmed through HSPICE simulations.

  • PDF

Characteristics of the Fault Current and the Protection for Superconducting and Normal Conducting Limiter combined with a Transformer (상용변압기와 결합된 초전도체 및 상전도체 한류기의 고장전류 및 보호기기 동작특성)

  • Im, In-Gyu;Choi, Hyo-Sang;Jung, Byung-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1313-1317
    • /
    • 2013
  • With increasing demand of power, the equipment of power system is enlarging and the absolute capacity is going up. As a result, when a fault occurs, the fault current is consistently increasing. Therefore, I suggested some solution for limiting the fault current more efficiently. This study shows the characteristics of superconducting limiting elements and normal conducting elements combined with a transformer. We performed a short-circuit test about the fault current by using SCR switching control system operated from a CT. When short circuit accidents happened in the secondary side of a transformer, fault currents flowed and a SCR switching control system was operated. It resulted in a decrease of the fault current in the limited elements of third winding connected in parallel. For this test, we used YBCO thin films and normal conducting elements as the limited elements. Within a cycle, a superconducting fault current limiter with YBCO thin films reduced more than 90% of fault current because the resistance of superconducting elements sustainedly grew. On the other hand, the limiter with normal conductors limited as much as a set value because its resistance characteristic was linear. Consequently, in case of the limiter with superconductor, limiting range of the circuit was wide but the range of protective detection was undefined. In contrast, as for the limiter with normal conductors, limiting range and protection duty were appropriate.

A position Detector of Permanent Magnet Step Motors (영구 자석형 스텝모터의 위치 검출)

  • 원종수;정훈
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.10
    • /
    • pp.703-712
    • /
    • 1987
  • A position detection method for 2 phase bifilar permanent magnet step motors is proposed. The back emfgenerated on 2 phase windings by rotor permanent magnet is calculated using motor terminal voltage and current by analog circuit, and the rotor position output is obtained from tese back emf signals through some logical manipulation circuit. This position detector functionally acts like a 2 channel optical incremental encoder, and it is also shown by experimental results that it works well over wide range of speed or under resonant condition where the rotor rings around the detent position. Its resolution is twice of the number of steps per revolution. Bu software implemented on micro-processor, the reliability of position output is enhanced, detecting and correcting error dut to external and/ or internal noise.

Performance Study of Defected Ground Structure Patch Antenna with Etched psi (ψ) Shaped Stubs

  • Nadeem, Iram;Choi, Dong-You
    • Journal of information and communication convergence engineering
    • /
    • v.16 no.4
    • /
    • pp.203-212
    • /
    • 2018
  • In this article, a novel design of patch antenna with wide band characteristics is presented. The proposed antenna is having electrical dimensions of $0.14{\lambda}{\times}0.11{\lambda}$ (at lower initial frequency) and footprints of $150mm^2$. Structural parameters optimization shows 3.1-23.5 GHz frequency range for a (reflection coefficient) $S_{11}{\leq}-10dB$ and simulated gain 6.8 dB is obtained. An equivalent circuit model is proposed to get an insight view of antenna. Advanced Systems Design (ADS) simulation results are obtain which confirm the validity of proposed model. Degenerated foster canonical form has been used to explain the reactance and capacitive behavior idea of simulated proposed antenna's input impedance later on an equivalent circuit model and smith chart is also suggested. HFSS and CST have been used to analyze antenna behavior. The proposed antenna can be further used for microwave image detection applications.

A 3-5GHz frequency band Programmable Impulse Radio UWB Transmitter (3-5 GHz 대역 중심 주파수 변환이 가능한 프로그래머블 임펄스 래디오 송신기)

  • Han, Hong-Gul;Kim, Tae-Wook
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.6
    • /
    • pp.35-40
    • /
    • 2012
  • This paper has proposed a 3~5 GHz IR-UWB low power transmitter for range detection application. Proposed transmitter which has been implemented in a $0.13{\mu}m$ CMOS technology is all digital circuit that consist of simple digital logic. this feature insure low complexity and low power consumption. In addition, center frequency can be changed by adopting voltage controlled delay cell for avoiding existing another radio frequency in UWB low band. Proposed circuit consume only 10pJ/b from 1.2 V supply voltage. The simulation results show 3.3~4.3 GHz center frequency controllability, -51 dBm/MHz maximum output power and is satisfied with FCC regulation.

Development of Wideband Frequency Modulated Laser for High Resolution FMCW LiDAR Sensor (고분해능 FMCW LiDAR 센서 구성을 위한 광대역 주파수변조 레이저 개발)

  • Jong-Pil La;Ji-Eun Choi
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.6
    • /
    • pp.1023-1030
    • /
    • 2023
  • FMCW LiDAR system with robust target detection capabilities even under adverse operating conditions such as snow, rain, and fog is addressed in this paper. Our focus is primarily on enhancing the performance of FMCW LiDAR by improving the characteristics of the frequency-modulated laser, which directly influence range resolution, coherence length, and maximum measurement range etc. of LiDAR. We describe the utilization of an unbalanced Mach-Zehnder laser interferometer to measure real-time changes of the lasing frequency and to correct frequency modulation errors through an optical phase-locked loop technique. To extend the coherence length of laser, we employ an extended-cavity laser diode as the laser source and implement a laser interferometer with an photonic integrated circuit for miniaturization of optical system. The developed FMCW LiDAR system exhibits a bandwidth of 10.045GHz and a remarkable distance resolution of 0.84mm.

Early Detection of Peripheral Intravenous Infiltration Using Segmental Bioelectrical Impedance: Preliminary Study

  • Kim, Jaehyung;Jeong, Ihnsook;Baik, Seungwan;Jeon, Gyerok
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.3
    • /
    • pp.482-490
    • /
    • 2017
  • Early detection of infiltration is one of the most important tasks of nurses to minimize skin damage due to infiltration. For subjects receiving invasive intravenous treatment, the bioelectrical impedance (impedance) were measured in the frequency range of 5 to 500 kHz using bioelectrical impedance spectroscopy (BIS). After attaching electrodes at both ends of a transparent dressing mounted on the skin in which IV solution was infused into the vein, the change in impedance was measured as a function of time and frequency before and after infiltration. The experimental results are described as follows. When IV solution was properly infused into the vein, the impedance was nearly constant over time and decreased with increasing frequency. However, when infiltration occurred, the impedance decreased significantly and thereafter gradually decreased with time. In addition, impedance decreased with time for all applied frequencies. In this study, when IV solution penetrated into the surrounding skin and subcutaneous tissue by infiltration, impedance was quantitatively analyzed for as a function of time and frequency. This suggests a method for early detection of infiltration using BIS.

An Accidental Position Detection Algorithm for High-Pressure Equipment using Microphone Array (Microphone Array를 이용한 고압설비의 고장위치인식 알고리즘)

  • Kim, Deuk-Kwon;Han, Sun-Sin;Ha, Hyun-Uk;Lee, Jang-Myung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2300-2307
    • /
    • 2008
  • This study receives the noise transmitted in a constant audio frequency range through a microphone array in which the noise(like grease in a pan) occurs on the power supply line due to the troublesome partial discharge(arc). Then by going through a series of signal processing of removing noise, this study measures the distance and direction up to the noise caused by the troublesome partial discharge(arc) and monitors the result by displaying in the analog and digital method. After these, it determines the state of each size and judges the distance and direction of problematic part. When the signal sound transmitted by the signal source of bad insulator is received on each microphone, the signal comes only in the frequency range of 20 kHz by passing through the circuit of amplification and 6th low pass filter. Then, this signal is entered in a digital value of digital signal processing(TMS320F2812) through the 16-bit A/D conversion. By doing so, the sound distance, direction and coordinate of bad insulator can be detected by realizing the correlation method of detecting the arriving time difference occurring on each microphone and the algorithm of detecting maximum time difference.