비직교성 전산화단층촬영에서 뇌정위수술용 좌표계를 이용한 표적위치 결정 (Determination of Target Position with BRW Stereoatic Frame in non-orthogonal CT scans)

  • Park, Tae-Jin;Kim, Ok-Bae;Son, Eun-Ik
    • 한국의학물리학회지:의학물리
    • /
    • 제3권1호
    • /
    • pp.53-62
    • /
    • 1992
  • 최근 두개부 종양의 방사성물질의 자입과 방사선입체조사에 의한 뇌수술이 개발되어 의료계 에 많은 관심을 끌고 있다. 또한 방사선수술등은 비관혈적인 체외조사이므로 뇌정위수술용 좌표계의 전산화단층촬영을 이용한 표적중심결정이 매우 중요하다. 현재 알려진 방법은 뇌정위수술용좌표계의 전산화단층찰영에 대한 직교성하에서 비교적 정확하게 표적의 위치를 결정하게 되나, 임상현장에서 직교성유지는 실제 어려운 실정이다. 이에 필자들은 임의의 비직교성 스켄하에서 정확한 표적좌표를 얻기위한 알고리즘을 사용하였으며, 표적오차는 평균 0.02$\pm$0.3mm를 보였다.

  • PDF

Optimization Technique using Ideal Target Model and Database in SRS

  • Oh, Seung-Jong;Suh, Tae-Suk;Song, Ju-Young;Choe, Bo-Young;Lee, Hyoung-Koo
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.146-149
    • /
    • 2002
  • The aim of stereotactic radiosurgery(SRS) is to deliver a high dose to a target region and a low dose to critical organ through only one or a few irradiation. To satisfy this aim, optimized irradiating conditions must be searched in the planning. Thus, many mathematical methods such as gradient method, simulated annealing and genetic algorithm had been proposed to find out the conditions automatically. There were some limitations using these methods: the long calculation time, and the difficulty of unique solution due to the different shape of tumor. In this study, optimization protocol using ideal models and data base was proposed. Proposed optimization protocol constitutes two steps. First step was a preliminary work. Some possible ideal geometry shapes, such as sphere, cylinder, cone shape or the combination, were assumed to approximate the real tumor shapes. Optimum variables such as isocenter position or collimator size, were determined so that the high dose region could be shaped to fit ideal models with the arrangement of multiple isocenter. Data base were formed with those results. Second, any shaped real targets were approximated to these models using geometry comparison. Then, optimum variables for ideal geometry were chosen from the data base predetermined, and final parameters were obtained by adjusting these data. Although the results of applying the data base to patients were not superior to the result of optimization in each case, it can be acceptable as a starting point of plan.

  • PDF

Hippocampal Sparing Whole Brain Radiotherapy and Integrated Simultaneous Boost vs Stereotactic Radiosurgery Boost: A Comparative Dosimetric Planning Study

  • Cheah, Soon Keat;Matthews, Thomas;Teh, Bin Sing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권9호
    • /
    • pp.4233-4235
    • /
    • 2016
  • Background: Whole brain radiotherapy (WBRT) and stereotactic radiosurgery were frequently used to palliate patients with brain metastases. It remains controversial which modality or combination of therapy is superior especially in the setting of limited number of brain metastases. The availability of newer medical therapy that improves survival highlighted the importance of reducing long term radiation toxicity associated with WBRT. In this study, we aim to demonstrate the hippocampal sparing technique with whole brain and integrated simultaneous boost Materials and Methods: Planning data from 10 patients with 1-5 brain metastases treated with SRS were identified. Based on the contouring guideline from RTOG atlas, we identified and contoured the hippocampus with 5mm isocentric expansion to form the hippocampal avoidance structure. The plan was to deliver hippocampal sparing whole brain radiotherapy (HSWBRT) of 30 Gy in 10 fractions and simultaneous boost to metastatic lesions of 30 Gy in 10 fractions each. Results: The PTV, hippocampus and hippocampal avoidance volumes ranges between 1.00 - 39.00 cc., 2.50 - 5.30 cc and 26.47 - 36.30 cc respectively. The mean hippocampus dose for the HSWBRT and HSWBRT and SIB plans was 8.06 Gy and 12.47 respectively. The max dose of optic nerve, optic chiasm and brainstem were kept below acceptable range of 37.5 Gy. Conclusions: The findings from this dosimetric study demonstrated the feasibility and safety of treating limited brain metastases with HSWBRT and SIB. It is possible to achieve the best of both worlds by combining HSWBRT and SIB to achieve maximal local intracranial control while maintaining as low a dose as possible to the hippocampus thereby preserving memory and quality of life.

뇌하수체 종양의 방사선 수술 시 영상 융합 프로토콜이 실제 PTV와 OAR 선량에 미치는 영향 (The Dosimetric Effect on Real PTV and OARs at Various Image Fusion Protocol for Pituitary Adenomas)

  • 이경남;이동준;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제21권4호
    • /
    • pp.354-359
    • /
    • 2010
  • 뇌하수체 종양의 치료 계획 시 다양한 영상 융합 프로토콜이 실제 PTV (planning target volume) coverage 및 OAR (organ at risk) 보호에 미치는 선량학적 영향을 확인하고자 하였다. 선량 체적 히스토그램(DVH, dose volume histogram)을 이용하여 각 프로토콜 별 실제 PTV의 coverage 및 그 변화 그리고 시각경로(optic pathway) 및 뇌간(brainstem)의 최대 흡수 선량과 임계 선량을 초과한 체적을 획득하였고 축상면(axial plane)과 관상면(coronal) 영상을 함께 사용하여 S-I (superior-inferior) 방향의 불확정도를 보정한 영상 융합 프로토콜이 축상면 만을 이용한 경우보다 시각경로 및 뇌간의 최대 흡수 선량과 임계 선량을 초과한 체적 모두 감소된 수치를 보임을 확인 하였다. 본 case에 한해 축상면 그리고 관상면 영상을 함께 사용하는 것이 OARs 보호에 가중치를 둔 방사선 수술 치료 계획 수립에 도움을 줄 수 있다.

Endoscopic Surgery for Pituitary Tumor

  • Kim, Dong-Hyun;Kim, Kyu-Hong;Cho, Young-Woon;Kim, Joon-Soo;Lee, In-Chang;Bae, Sang-Do
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권1호
    • /
    • pp.20-24
    • /
    • 2005
  • Objective: The purpose of this study is to assess the efficacy and advantages of an endoscopic endonasal approach for the treatment of pituitary tumors. Methods: We retrospectively analyzed the records of 31 patients with pituitary tumors having endoscopic endonasal surgery between March 1999 and August 2003. Results: Among 31 patients with pituitary adenomas, 25 (81%) patients exhibited gross total removal of tumor on postoperative MRI within 3 days after surgery. Among 6 patients removed subtotally, 2 had only radiosurgery, 3 have had periodic follow-up MRIs and one patient with large extended tumor (grade IV, Stage E) had secondary transcranial removal of tumor before radiosurgery. Postoperative complications included cerebrospinal fluid leak in 2 patients, sinusitis in 1 patient, and one patient died due to unexpected intracerebral hemorrhage on 5 days after surgery. Besides considerable experiences with this approach are needed because of narrow working channel to the sella turcica, the results of our study showed following advantages of this procedure: visualization of areas not seen with the operating microscope, elimination of oronasal complications, more functional and cosmetic outcome, and shortened operative time and hospital stay. Conclusion: The authors consider that endoscopic endonasal transsphenoidal approach provides good results with minimal invasion for patients with pituitary tumors.

Multi-Modality Treatment for Intracranial Arteriovenous Malformation Associated with Arterial Aneurysm

  • Ha, Joo-Kyung;Choi, Seok-Keun;Kim, Tae-Sung;Rhee, Bong-Arm;Lim, Young-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권2호
    • /
    • pp.116-122
    • /
    • 2009
  • Objective: Intracranial arteriovenous malformation (AVM) associated with aneurysm has been infrequently encountered and the treatment for this malady is challenging. We report here on our clinical experience with AVMs associated with arterial aneurysms that were managed by multimodality treatments, including clipping of the aneurysm, microsurgery, Gamma-knife radiosurgery (GKS) and Guglielmi detachable coil (GDC) embolization. Methods: We reviewed the treatment plans, radiological findings and clinical courses of 21 patients who were treated with GKS for AVM associated with aneurysm. Results: Twenty-seven aneurysms in 21 patients with AVMs were enrolled in this study. Hemorrhage was the most frequent presenting symptom (17 patients: 80.9%). Bleeding was caused by an AVM nidus in 11 cases, aneurysm rupture in 5 and an undetermined origin in 1. Five patients were treated for associated aneurysm with clipping followed by GKS for the AVM and 11 patients were treated with GDC embolization combined with GKS for an AVM. Although 11 associated aneurysms remained untreated after GKS, none of them ruptured and 4 aneurysms regressed during the follow up period. Two aneurysms increased in size despite the disappearance of the AVM nidus after GKS and then these aneurysms were treated with GDC embolization. Conclusion: If combined treatment using microsurgery, GKS and endovascular treatment can be adequately used for these patients, a better prognosis can be obtained. In particular, GKS and GDC embolization are considered to have significant roles to minimize neurologic injury.

Cerebral Arteriovenous Malformation Associated with Moyamoya Disease

  • Noh, Jung-Hoon;Yeon, Je Young;Park, Jae-Han;Shin, Hyung Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권4호
    • /
    • pp.356-360
    • /
    • 2014
  • The coexistence of moyamoya disease (MMD) with an arteriovenous malformation (AVM) is exceedingly rare. We report two cases of AVM associated with MMD. The first case was an incidental AVM diagnosed simultaneously with MMD. This AVM was managed expectantly after encephalo-duro-arterio-synangiosis (EDAS) as the main feeders stemmed from the internal carotid artery, which we believed would be obliterated with the progression of MMD. However, the AVM persisted with replacement of the internal carotid artery feeders by new external carotid artery feeders from the EDAS site. The AVM was eventually treated with gamma knife radiosurgery considering an increasing steal effect. The second case was a de novo AVM case. The patient was initially diagnosed with MMD, and acquired an AVM eight years later that was slowly fed by the reconstituted anterior cerebral artery. Because the patient remained asymptomatic, the AVM is currently being closely followed for more than 2 years without further surgical intervention. Possible differences in the pathogenesis and the radiologic presentation of these AVMs are discussed with a literature review. No solid consensus exists on the optimal treatment of MMD-associated AVMs. Gamma knife radiosurgery appears to be an effective treatment option for an incidental AVM. However, a de novo AVM may be managed expectantly considering the possible risks of damaging established collaterals, low flow characteristics, and probably low risks of rupture.

The Variable Ellipsoid Modeling Technique as a Verification Method for the Treatment Planning System of Gamma Knife Radiosurgery

  • Hur, Beong-Ik;Choi, Byung-Kwan;Sung, Soon-Ki;Cho, Won-Ho;Cha, Seung-Heon;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • 제47권2호
    • /
    • pp.128-133
    • /
    • 2010
  • Objective : The secondary verification of Leksell Gamma Knife treatment planning system (LGP) (which is the primary verification system) is extremely important in order to minimize the risk of treatment errors. Although prior methods have been developed to verify maximum dose and treatment time, none have studied maximum dose coordinates and treatment volume. Methods : We simulated the skull shape as an ellipsoid with its center at the junction between the mammillary bodies and the brain stem. The radiation depths of the beamlets emitted from 201 collimators were calculated based on the relationship between this ellipsoid and a single beamlet expressed as a straight line. A computer program was coded to execute the algorithm. A database system was adopted to log the doses for $31{\times}31{\times}31$ or 29,791 matrix points allowing for future queries to be made of the matrix of interest. Results : When we compared the parameters in seven patients, all parameters showed good correlation. The number of matrix points with a dose higher than 30% of the maximal dose was within ${\pm}\;2%$ of LGP. The 50% dose volume, which is generally the target volume, differs maximally by 4.2%. The difference of the maximal dose ranges from 0.7% to 7%. Conclusion : Based on the results, the variable ellipsoid modeling technique or variable ellipsoid modeling technique (VEMT) can be a useful and independent tool to verify the important parameters of LGP and make up for LGP.

Maximum diameter versus volumetric assessment for the response evaluation of vestibular schwannomas receiving stereotactic radiotherapy

  • Choi, Youngmin;Kim, Sungmin;Kwak, Dong-Won;Lee, Hyung-Sik;Kang, Myung-Koo;Lee, Dong-Kun;Hur, Won-Joo
    • Radiation Oncology Journal
    • /
    • 제36권2호
    • /
    • pp.114-121
    • /
    • 2018
  • Purpose: To explore the feasibility of maximum diameter as a response assessment method for vestibular schwannomas (VS) after stereotactic radiosurgery or fractionated stereotactic radiotherapy (RT), we analyzed the concordance of RT responses between maximum diameters and volumetric measurements. Materials and Methods: Forty-two patients receiving curative stereotactic radiosurgery or fractionated stereotactic RT for VS were analyzed retrospectively. Twelve patients were excluded: 4 did not receive follow-up magnetic resonance imaging (MRI) scans and 8 had initial MRI scans with a slice thickness >3 mm. The maximum diameter, tumor volume (TV), and enhanced tumor volume (ETV) were measured in each MRI study. The percent change after RT was evaluated according to the measurement methods and their concordances were calculated with the Pearson correlation. The response classifications were determined by the assessment modalities, and their agreement was analyzed with Cohen kappa statistics. Results: Median follow-up was 31.0 months (range, 3.5 to 86.5 months), and 90 follow-up MRI studies were analyzed. The percent change of maximum diameter correlated strongly with TV and ETV (r(p) = 0.85, 0.63, p = 0.000, respectively). Concordance of responses between the Response Evaluation Criteria in Solid Tumors (RECIST) using the maximum diameters and either TV or ETV were moderate (kappa = 0.58; 95% confidence interval, 0.32-0.85) or fair (kappa = 0.32; 95% confidence interval, 0.05-0.59), respectively. Conclusions: The percent changes in maximum diameter and the responses in RECIST were significantly concordant with those in the volumetric measurements. Therefore, the maximum diameters can be used for the response evaluation of VS following stereotactic RT.

정위 마스크 시스템을 사용한 방사선수술시 회전중심점의 재현성 (Isocenter Reproducibility with Mask Fixation System in Stereotactic Radiosurgery)

  • 이동준;손문준;이기택;최찬영;황금철;황충진
    • 한국의학물리학회지:의학물리
    • /
    • 제13권3호
    • /
    • pp.135-138
    • /
    • 2002
  • 치료대상 병소에 분할 방사선수술을 시술할 경우 회전중심(isocenter)은 정확하고 재현성 이 있어야 한다. 본 연구는 노발리스 방사선 수술장비와 정위 마스크 시스템을 사용한 분할방사선 수술에서 회전중심의 재현성을 측정하고 평가 하였다. 마스크는 열가소성 재질의 상용을 사용하였고 회전중심의 재현성을 측정하기 위해 고안된 머리 모양의 아크릴 팬텀에 맞도록 제작하였다. 팬텀의 내부에는 직경 5 mm의 아크릴봉을 수직으로 세우고 그 끝단을 회전중심으로 선택하였으며 예상되는 회전중심점에 pin hole을 낸 monochromic 필름을 설치하여 방사선 조사 후 회전중심의 재현성을 측정할 수 있도록 하였다. 측정 결과 회전중심은 공간오차가 평균 1 mm 이내이고 표준편차 또한 2 mm 이내여서 이미 보고된 타 문헌에서의 측정값과 비교해 볼 때 모든 측정값이 제시된 오차범위 내에 있었다. 결론적으로 분할방사선수술에 사용하는 정위 마스크 시스템은 매우 정확하고 재현성이 우수하였으며, 실제로 방사선 수술대상의 병소의 직경이 10 mm 정도 이상이라면 일반적인 한번의 고선량 방사선 수술에 정위 마스크 시스템의 사용이 가능할 것으로 사료된다.