Development of an Anomaly Detection Algorithm for Verification of Radionuclide Analysis Based on Artificial Intelligence in Radioactive Wastes (방사성폐기물 핵종분석 검증용 이상 탐지를 위한 인공지능 기반 알고리즘 개발)

  • Seungsoo Jang;Jang Hee Lee;Young-su Kim;Jiseok Kim;Jeen-hyeng Kwon;Song Hyun Kim
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.19-32
    • /
    • 2023
  • The amount of radioactive waste is expected to dramatically increase with decommissioning of nuclear power plants such as Kori-1, the first nuclear power plant in South Korea. Accurate nuclide analysis is necessary to manage the radioactive wastes safely, but research on verification of radionuclide analysis has yet to be well established. This study aimed to develop the technology that can verify the results of radionuclide analysis based on artificial intelligence. In this study, we propose an anomaly detection algorithm for inspecting the analysis error of radionuclide. We used the data from 'Updated Scaling Factors in Low-Level Radwaste' (NP-5077) published by EPRI (Electric Power Research Institute), and resampling was performed using SMOTE (Synthetic Minority Oversampling Technique) algorithm to augment data. 149,676 augmented data with SMOTE algorithm was used to train the artificial neural networks (classification and anomaly detection networks). 324 NP-5077 report data verified the performance of networks. The anomaly detection algorithm of radionuclide analysis was divided into two modules that detect a case where radioactive waste was incorrectly classified or discriminate an abnormal data such as loss of data or incorrectly written data. The classification network was constructed using the fully connected layer, and the anomaly detection network was composed of the encoder and decoder. The latter was operated by loading the latent vector from the end layer of the classification network. This study conducted exploratory data analysis (i.e., statistics, histogram, correlation, covariance, PCA, k-mean clustering, DBSCAN). As a result of analyzing the data, it is complicated to distinguish the type of radioactive waste because data distribution overlapped each other. In spite of these complexities, our algorithm based on deep learning can distinguish abnormal data from normal data. Radionuclide analysis was verified using our anomaly detection algorithm, and meaningful results were obtained.

Diagnostic Significance of Radionuclide Venography - A Comparison with X-ray Contrast Venography - (방사성동위원소정맥촬영술(放射性同位元素靜脈撮影術)의 진단적(診斷的) 의의(意義) - X-선정맥조영술(線靜脈造影術)과의 비교(比較) 연구(硏究) -)

  • Bae, S.H.;Park, J.H.;Han, M.C.;Cho, B.Y.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.15 no.2
    • /
    • pp.19-25
    • /
    • 1981
  • Radionuclide venographies were performed in 138 limbs of 58 patients and X-ray contrast venographies were performed in 23 paitents of them. Positive radionuclide venography findings were area of decreased sponding to the region of thrombosis, abnormal collateral flows below the lesion. The success rate of radionulide venography was 89% and the overall concordance between radionuclide venography and X-ray contrast venography was 91%. Radionuclide venography is simple and easy to perform and less invasive than X-ray contrast venography. These results indicate that radionuclide venography is the most ideal screening test for the detection of venous thrombosis in patient with signs & symptoms of deep vein thrombosis.

  • PDF

A Case of Spontaneous Intracranial Hypotension: Detection of Cerebrospinal Fluid Leakage by Early Dynamic Radionuclide Cisternography (방사성핵종 뇌조조영술의 조기 동적 영상으로 뇌척수액 누출을 증명한 자발성 두개 내 저압 1예)

  • Kim, Jae-Soo;Yang, Dae-Woong;Park, Seok-Gun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.184-188
    • /
    • 1999
  • Although cerebrospinal fluid leakage is suggested as one of the causes of spontaneous intracranial hypotension, only a few cases with direct evidence of cerebrospinal fluid leakage on radionuclide cisternography have been reported in the literature. Indirect evidences of cerebrospinal fluid leakage such as early visualization of the soft tissue and bladder or delayed migration of radiotracer have been observed in most patients with spontaneous intracranial hypotension. We report a case of spontaneous intracranial hypotension in which cerebrospinal fluid leakage was directly demonstrated by early dynamic imaging of spine on radionuclide cisternography. We suggest that early dynamic imaging of spine is an important adjunctive procedure in detecting cerebrospinal fluid leakage in patients with spontaneous intracranial hypotension.

  • PDF

Evaluation of Cardiac Function Using Radioisotope before and after Open Heart Surgery -Detection of Preoperative Cardiac Shunt and Postoperative Remnant Shunt by Nuclear Angiocardiography- (개심술 전후 방사성 동위원소를 이용한 심기능 평가에 관한 연구 -수술전 shunt 의 진단 및 교정수술후의 성적평가에 대하여-)

  • 서경필
    • Journal of Chest Surgery
    • /
    • v.15 no.2
    • /
    • pp.194-203
    • /
    • 1982
  • In this investigation we undertook to evaluate the utility of radionuclide cardiac angiography in the detection of cardiac shunts before and after surgical correction. Time-activity curves of ventricles and lungs were evaluated after bolus intravenous injection of 99mTc-human serum albumin in 512 preoperative patients and 551 post-operative patients. Omitting 31 cases of technical failure due to poor bolus, we detected shunts in 459 cases of 481 preoperative evaluations, so the detectability was 95.4%. The cases which couldn`t be detected by this method had small amount of shunt. Also the degree of shunt detected by radioisotope methods were well correlated with oxymetry method. [r=0.89, p<0.01 ] In postoperative evaluations, 18 out of 411 patients with left to right shunt and 10 out of 140 right to left shunt were found to have remnant shunts with radionuclide cardiac angiography. Of the 28 cases with failed operation, 2 were confirmed in reoperation, 2 by cardiac catheterization, 2 by two -dimensional echocardiography. All except one .f these patients had membranous ventricular septal defects and those with left to right shunts had moderate to severe pulmonary hypertension and shunt amount. Also those had larger septal defects than control group. We consider that radionuclide cardiac angiography is a simple and noninvasive method which can show the preoperative diagnosis and postoperative follow up of cardiac shunts.

  • PDF

Preparation and Radionuclide Detection Analysis of Inorganic Fluor Impregnated Double-layered Membranes (이중구조 무기형광 함침막 제조 및 방사성핵종 탐지능력의 분석)

  • 이근우;서범경;박진호;남석태;한명진
    • Membrane Journal
    • /
    • v.12 no.4
    • /
    • pp.240-246
    • /
    • 2002
  • New polysulfone scintillation proximity membranes were prepared by impregnating Cerium Activated Yttrium Silicate (CAYS), an inorganic fluor, in a membrane structure. The membranes were applied to detect the radionuclide contamination directly without the aid of a scintillation cocktail. The preparation of membranes was divided into two processes. A supporting polymer film was made of casting solutions consisting of polysulfone and solvent, their cast film being solidified by vacuum evaporation. CAYS-dispersed polymer solutions were cast over the first, solidified polymer films and coagulated either by evaporating solvent or by exchanging solvent in the solution with nonsolvent in a coagulation bath. The prepared membranes had two distinguished, but tight1y attached, double layers: one is the supporting layer of dense polymer film and the other the detecting layer consisting of CAYS and polymer. The radionuclide counting results revealed that the prepared membranes were efficient to monitor radioactivity contamination with reliable counting ability.

Changing Role of Nuclear Medicine for the Evaluation of Focal Hepatic Tumors: From Lesion Detection to Tissue Characterization (국소 간 종양의 조직적 특성을 평가하는데 있어 최근 핵의학의 역할)

  • Kim, Chun-Ki;Yu, Mi-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.211-224
    • /
    • 1998
  • The role of scintigraphic imaging has moved from the detection of lesions to the tissue-specific characterization of lesions over the past 2 decades. Major advances in nuclear medicine imaging include: 1) positron imaging, 2) improved instrumentation, such as the use of multidetector (dual or triple head) gamma cameras for single photon emission computed tomography, and 3) development of numerous new radiopharmaceuticals for positron or single photon imaging (labeled glucose analogue, amino acids, fatty acids, hormones, drugs, receptor ligands, monoclonal antibodies, etc). These advances have resulted in a significantly improved efficacy of radionuclide techniques for the evaluation of various tumors, including those within the liver. The current role of nuclear medicine in the evaluation of focal hepatic tumors is reviewed in this article with an emphasis on the clinical applications of various tracer studies and imaging findings.

  • PDF

A Study on the Radionuclide Cardiac Angiography in the Various Heart Diseases (각종(各種) 심질환(心疾患)에서 방사성(放射性) 동위원소(同位元素) 심혈관촬영술(心血管撮影術)에 관한 연구(硏究))

  • Chung, June-Key;Park, Sun-Yang;Ryu, Park-Young;Cho, Bo-Yeon;Kim, Byoung-Kuk;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.13 no.1_2
    • /
    • pp.7-14
    • /
    • 1979
  • Radionuclide cardiac angiography has distinct advantages in safety, patient comfort, cost and ease of performance. This method offers diagnostic accuracy equivalent to that of cardiac catheterization. By this method the qualitative and quantitative diagnosis of the cardiac shunts are available. Also for it is repeatable with ease and more physiologic, it has application in following pre- and post-operative shunt patients. We performed the radionuclide cardiac angiographies in 147 cases of heart diseases and 26 cases of normal group. 1. The detection of left-to-right shunt was possible in 22 of 24 patients, and 2 patients were not diagnosed due to small shunt amount. (Qp/Qs<1.3) In 21 patients of right-to-left shunt, all were diagnosed by radionuclide cardiac angiography. 2. With the pulmonary time-activity curve, $C_2/C_1$ ratio was calculated. In normal control group, a range of $C_2/C_1$ ratios of $21{\sim}38%$ was established with a mean value of $28.6{\pm}4.6%$. In patients with left-to-right shunts determined by catheterization data, the range of $C_2/C_1$ ratio was $33{\sim}90%$, with a mean value of $67.8{\pm}12.2%$. 3. In 8 cases of left-to-right shunt, $Q_p/Q_s$ ratios determined by radionuclide cardiac angiography were compaired with those of cardiac catheterization. The correlation coefficient was 0.907. (P<0.001) 4. Postoperative radionuclide cardiac angiographies were done in 21 cases. 3 of 13 patients with left-to-right shunts were found to have residual shunts. 8 patients with right-to-left shunts were confirmed to have no residual shunt.

  • PDF

Quantitative Comparison of Activity Calculation Methods for the Selection of Most Reliable Radionuclide Inventory Estimation

  • Hwang, Ki-Ha;Lee, Sang-Chul;Lee, Kun-Jai;Jeong, Chan-Woo;Ahn, Sang-Myeon;Kim, Tae-Wook;Kim, Kyoung-Doek;Herr, Y.H.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.322-327
    • /
    • 2003
  • It is important to know the accurate radionuclide inventory of radioactive waste for the reliable management. However, estimation of radionuclide concentrations in drummed radioactive waste is difficult and unreliable because of difficulties of direct detection, high cost, and radiation exposure of sampling personnel. In order to overcome these difficulties, scaling factors (SFs) have been used to assess the activities of radionuclides that could not be directly analyzed. A radionuclide assay system has been operated at KORI site since 1996 and consolidated scaling factor method has played a dominant role in determination of radionuclides concentrations. However, some problems are still remained such as uncertainty of estimated scaling factor values, inaccuracy of analyzed sample values, and disparity between the actual and ideal correlation pairs and the others. Therefore, it needs to improve the accuracy of scaling factor values. The scope of this paper is focused on the improvement of accuracy and representativeness of calculated scaling factor values based on statistical techniques. For the selection of reliable activity determination method, the accuracy of estimated SF values for each activity determination method is compared. From the comparison of each activity determination methods, it is recommended that SF determination method should be changed from the arithmetic mean to the geometrical mean for more reliable estimation of radionuclide activity. Arithmetic mean method and geometric mean method are compared based on the data set in KORI system.

  • PDF

Spectral resolution evaluation by MCNP simulation for airborne alpha detection system with a collimator

  • Kim, Min Ji;Sung, Si Hyeong;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1311-1317
    • /
    • 2021
  • In this study, an airborne alpha detection system, which consists of a passivated implanted planar silicon (PIPS) detector and an air filter, was developed. A collimator applied to the alpha detection system showed an enhancement in resolution and a degradation in detection efficiency. The resolution and detection efficiency were compared and analyzed to evaluate the performance of the collimator. Thus, the resolution was found to be more important than the efficiency as a determining factor of the detection system performance, from the viewpoint of radionuclide identification. The performance was evaluated on three properties of the collimator: hole shape, hole length, and the ratio between the hole and frame pitches. From the hole shape performance evaluation, a hexagonal collimator showed the highest resolution. Further, the collimator with a hole pitch of 14 mm was found to have the highest resolution while that with a frame pitch of 4-6 mm (i.e., 1.2-1.4 times longer than the hole pitch) showed the highest resolution.

Analysis of ultra-low radionuclide concentrations in water samples with baromembrane method

  • Vasyanovich, Maxim;Ekidin, Aleksey;Trapeznikov, Alexander;Plataev, Anatoly
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.253-257
    • /
    • 2021
  • This work demonstrates the use of baromembrane method based on reverse osmosis (RO) process. The method is realized on mobile complex, which allows to concentrate and determine ultra-low activity of radionuclides in water cooling ponds of Russian nuclear fuel cycle enterprises. The existence level of radionuclide background creates difficult conditions for identification the contribution of liquid discharges enterprise, as standard monitoring methods have a very high detection level for radionuclides. Traditional methods for determining the background radionuclides concentrations require the selection of at least 500 liters (l) of water, followed by their evaporation to form a dry residue. This procedure with RO membranes requires at least 5 days. It is possible to reduce the time and energy spent on evaporation of hundreds of water liters by pre-concentrating radionuclides in a smaller sample volume with baromembrane method. This approach allows preliminary concentration of water samples from 500 l volume till 20 l volume during several hours. This approach is universal for the concentration of dissolved salts of any heavy metals, other organic compounds and allows the preparation of water countable samples in much shorter time compared to the traditional evaporation method.