디지탈 X-선 촬영 시스템의 정보용량 분석 (Analysis of the information capacity of digital radiograpy system)

  • 김종효;민병구;박광석;한만청
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.564-569
    • /
    • 1990
  • In this paper, the information capacity, the Integrate performance measure of digital radiography system has been quantitatively analyzed. The effect of various factors affecting the information capacity of the digital radiography system in multi-stage detection processes has been considered and analyzed In detail. The results show that the more Information capacity can be obtained with the smaller detector cell area, despite of the decreasing signal to noise ratio due to the reduced number of X-ray photons per detector cell. And also has been Indicated that the Increase of the information capacity may be severely lost by the addition of electric noise in final read-out stage.

  • PDF

다양한 디지털 방사선 시스템의 물리적 영상 특성 조사 (Investigation of Physical Imaging Properties in Various Digital Radiography Systems)

  • 정회원;민정환;윤용수;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권3호
    • /
    • pp.363-370
    • /
    • 2017
  • 본 연구는 전하결합소자(charged coupled device; CCD), CR (computed radiography), 평판형검출기(flat panel detector; FPD) 등을 사용하는 다양한 디지털 방사선(digital radiography; DR) 시스템의 물리적 영상 특성의 평가를 실시한 것이다. 본 연구에서 적용된 영상 특성은 신호응답특성(system response), 해상력특성(modulation transfer function; MTF), 잡음특성(wiener spectrum; WS), 양자검출효율(detective quantum efficiency; DQE) 등이며 이를 통하여 DR 시스템의 성능을 비교하였다. CCD의 신호응답특성은 입사선량에 비례하여 증가하였으며, CR과 FPD는 입사선량의 증가에 대수적 비례 관계를 보이면서 증가하였다. MTF는 CR과 FPD는 유사한 경향을 나타내었지만 CCD는 떨어지는 값을 나타내었다. WS는 FPD가 가장 낮았고, CR, CCD 순으로 증가하였다. DQE는 FPD, CR, CCD의 순으로 나타났다. DR 시스템은 영상수용체의 종류에 따라 서로 다른 영상 특성이 나타났다. 의료영상 획득 시 DR 시스템을 올바르게 사용하려면 영상의 물리적 특성을 정확히 알고 사용하는 것이 중요하다.

디지털 방사선 투과영상의 식별도 평가 연구 (The Study on Image Sensitivity Evaluation For Digital Radiography Image)

  • 박상기;이영호
    • 동력기계공학회지
    • /
    • 제12권6호
    • /
    • pp.70-77
    • /
    • 2008
  • The purpose of this study is to compare the quality of digital radiography image with that of classical film images for welded structure in power plants. The CMOS(Complementary Metal Oxide Semiconductor) flat panel detecter and Agfa D5 film are used to image flaw specimens respectively. In the test, CMOS flat panel detector has been determined to have a better image than that of film image. In the IQI(Image Quality Indicator) transmission test, one or two more line can be seen in digital image than in film image. Digital Radiography Test enabled to successfully detect all defects on the weld specimens fabricated with real reheat stem pipe and boiler tube as well. In the specific comparison test, Digital radiography test detected micro flaws in the size of 0.5 mm in length by 0.5 mm in depth. However, film test has limited it to 1.0 mm in length by 1.0 mm in depth. As a result of this study, digital radiography technology is estimated well enough to perform the inspection in the industry with far more cost effective way, compared to the classical film test.

  • PDF

강내형 X선 튜브 온도 및 선량 분포 특성 (The Characteristic of Temperature and Dose Distribution of intra oral X-ray Tube)

  • 조성호;이레나
    • 전자공학회논문지
    • /
    • 제50권5호
    • /
    • pp.262-266
    • /
    • 2013
  • 신개념 치과용 X선 촬영장치인 강내형 X선 튜브에 대한 연구가 소개되었다. 이는 초소형의 X-선 튜브를 구강내 삽입하여 외부에서 검출기로 영상을 획득하는 새로운 시스템이다. 본 연구에서는 구내 치근단 촬영을 위해 사용하는 강내형 X선 튜브의 온도분포 및 선량 분포 특성을 조사하였다. X선 튜브의 온도특성을 파악하기 위하여 튜브 표면에 써머커플을 부착하여 튜브 표면에서부터 거리에 대한 온도를 측정하였으며, EBT 필름을 이용하여 튜브표면에서부터 거리에 따른 선량 분포를 측정하였다. 그 결과 냉각장치가 없는 튜브에서 2mm 이상 거리에서 온도는 $27^{\circ}C$로 일정하였으며, 튜브에서 3cm, 5cm일 때 선량분포가 3.14, 1.84mGy로 나타났다. 그 결과 제안한 시스템은 기존 시스템에 비해 낮은 선량에서 안전하게 촬영이 가능한 것으로 향후 구내 치근단 촬영장치에 새로운 변화를 가져올 수 있을 것으로 사료된다.

Comparative Study of the Effective Dose from Panoramic Radiography in Dentistry Measured Using a Radiophotoluminescent Glass Dosimeter and an Optically Stimulated Luminescence Detector

  • Lee, Kyeong Hee;Kim, Myeong Seong;Kweon, Dae Cheol;Choi, Jiwon
    • Journal of the Korean Physical Society
    • /
    • 제73권9호
    • /
    • pp.1377-1384
    • /
    • 2018
  • Accurate measurement of the absorbed dose and the effective dose is required in dental panoramic radiography involving relatively low energy with a rotational X-ray tube system using long exposures. To determine the effectiveness of measuring the irradiation by using passive dosimetry, we compared the entrance skin doses by using a radiophotoluminescent glass dosimeter (RPL) and an optically stimulated luminescence detector (OSL) in a phantom model consisting of nine and 31 transverse sections. The parameters of the panoramic device were set to 80 kV, 4 mA, and 12 s in the standard program mode. The X-ray spectrum was applied in the same manner as the panoramic dose by using the SpekCalc Software. The results indicated a mass attenuation coefficient of $0.008226cm^2/g$, and an effective energy of 34 keV. The equivalent dose between the RPL and the OSL was calculated based on a product of the absorbed doses. The density of the aluminum attenuators was $2.699g/cm^3$. During the panoramic examination, tissue absorption doses with regard to the RPL were a surface dose of $75.33{\mu}Gy$ and a depth dose of $71.77{\mu}Gy$, those with regard to the OSL were surface dose of $9.2{\mu}Gy$ a depth dose of $70.39{\mu}Gy$ and a mean dose of $74.79{\mu}Gy$. The effective dose based on the International Commission on Radiological Protection Publication 103 tissue weighting factor for the RPL were $0.742{\mu}Sv$, $8.9{\mu}Sv$, $2.96{\mu}Sv$ and those for the OSL were $0.754{\mu}Sv$, $9.05{\mu}Sv$, and $3.018{\mu}Sv$ in the parotid and sublingual glands, orbit, and thyroid gland, respectively. The RPL was more effective than the OSL for measuring the absorbed radiation dose in low-energy systems with a rotational X-ray tube.

Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구 (A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index)

  • 김재인;이양섭;장동수;정민철;배승호;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제13권3호
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF

자동노출제어장치를 이용한 요추 측면 방사선검사 시 환자 중심 위치 변화가 선량과 화질에 미치는 영향 (Effects of Dose and Image Quality according to Center Location in Lumbar Spine Lateral Radiography Using AEC Mode)

  • 정운찬;주영철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권2호
    • /
    • pp.85-90
    • /
    • 2021
  • The purpose of this study is to consider usefulness of using AEC mode and importance of patient center location in L-spine lateral radiography by comparing dose and image quality according to the change of patient center location with using AEC mode or not. In this study, guide wire is attached to the human body phantom's lumbar spine and the lead ruler is attached to the bottom of the wall detector to find out center location in detector. ESD, mAs, and EI were selected as dose factors, and image quality was compared through SNR. With the lumbar spine located center of the detector, dose factors and image quality were compared according to using AEC mode or not. Afterwards, phantom moved 4 cm and 8 cm back and forth and compared dose factors and image quality. The exposure parameters were 85 kVp, 320 mA, x-ray field size 10×17 inch, and the distance between the center X-ray and the detector was fixed at 100 cm. The center X-ray was perpendicular to the fourth lumbar spine and the only bottom AEC chamber was used. All data were analyzed by independent t-test and ANOVA. As a result of this study, with AEC when the center is matched, ESD was 1.31±0.01 mGy, without AEC was 2.12±0.01 mGy. SNR was shown to be 22.81±1.83, and 23.44±1.87 respectively. When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD were 1.09±0.004 mGy, 0.32±0.003 mGy, 1.19±0.017 mGy, 1.11±0.006 mGy respectively, SNR were 18.29±0.60 dB, 11.11±0.22 dB, 18.98±0.80 dB, 17.71±0.82 dB. Using AEC in L-spine lateral radiography reduced ESD by 38%, EI by 35%, and mAs by 38%, without any difference in SNR(p<0.05). When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD was decreasing each 16%, 75%, 9%, 15%, EI was decreasing each 14%, 77%, 15%, 20%, mAs was decreasing each 15% 75% 9%, 15%. SNR was decreasing each 19%, 51%, 17%, 22%.

신개념 치과용 X-선 영상장치 소개 - 강내형 X-선 튜브 (Introduction of Dental X-ray Imaging with New Concept - intra Oral x-ray Tube)

  • 조성호;김동영;백광우;이레나
    • 전자공학회논문지SC
    • /
    • 제48권4호
    • /
    • pp.94-101
    • /
    • 2011
  • 구내 치근단 촬영을 위한 수 많은 영상 장치가 활발히 연구되고 있으나, 현재까지의 X 선 장치는 강내형 센서 기반의 촬영 장치를 사용함으로서 환자의 고통, 피폭선량 등 많은 문제점이 있어왔다. 본 연구에서는 이러한 여러 문제점들을 해결할 수 있을 뿐만 아니라 이 분야에 새로운 변화를 가져올 수 있는 신개념의 치근단 촬영장치인 강내형 X-선 튜브를 사용한 치과용 영상 시스템을 소개한다. 이 신개념 치근단 X 선 촬영 시스템은 초소형 열전자 또는 냉전자 기반의 초소형 X-선 튜브, CMOS 기반의 검출기 및 이에 상응하는 자동 위치제어 및 시스템 제어장치를 포함한 몸체 부분으로 구성된다. 제안한 신개념 촬영장치의 가능성을 알아보기 위하여 XOFT사의 초소형 X-선 튜브를 이용하여 시스템을 구축하였으며 이러한 시스템의 성능 평가를 콜리메이터 유무에 따라 평가하였다. 또한 기존 시스템과 신개념 영상장치를 모두 이용하여 동일 치아 영상을 획득한 후 비교 분석 함으로서 제안된 시스템이 보다 우수한 영상 획득 및 분석이 가능함을 보여 주었으며 이러한 결과는 치근단 X 선 촬영장치 분야에 새로운 변화를 가져올 수 있을 것으로 사료된다.