• Title/Summary/Keyword: radiography

Search Result 2,223, Processing Time 0.03 seconds

Two Dimensional Size Effect on the Compressive Strength of T300/924C Carbon/Epoxy Composite Plates Considering Influence of an Anti-buckling Device (T300/924C 탄소섬유/에폭시 복합재 적층판의 이차원 압축 강도의 크기효과 및 좌굴방지장치의 영향)

  • ;;;C. Soutis
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.88-91
    • /
    • 2002
  • The two dimensional size effect of specimen gauge section (length x width) was investigated on the compressive behavior of a T300/924 [45/-45/0/90]3s, carbon fiber-epoxy laminate. A modified ICSTM compression test fixture was used together with an anti-buckling device to test 3mm thick specimens with a 30$\times$30, 50$\times$50, 70$\times$70, and 90mm$\times$90mm gauge length by width section. In all cases failure was sudden and occurred mainly within the gauge length. Post failure examination suggests that $0^{\circ}$ fiber microbuckling is the critical damage mechanism that causes final failure. This is the matrix dominated failure mode and its triggering depends very much on initial fiber waviness. It is suggested that manufacturing process and quality may play a significant role in determining the compressive strength. When the anti-buckling device was used on specimens, it was showed that the compressive strength with the device was slightly greater than that without the device due to surface friction between the specimen and the device by pretoque in bolts of the device. In the analysis result on influence of the anti-buckling device using the finite element method, it was found that the compressive strength with the anti-buckling device by loaded bolts was about 7% higher than actual compressive strength. Additionally, compressive tests on specimen with an open hole were performed. The local stress concentration arising from the hole dominates the strength of the laminate rather than the stresses in the bulk of the material. It is observed that the remote failure stress decreases with increasing hole size and specimen width but is generally well above the value one might predict from the elastic stress concentration factor. This suggests that the material is not ideally brittle and some stress relief occurs around the hole. X-ray radiography reveals that damage in the form of fiber microbuckling and delamination initiates at the edge of the hole at approximately 80% of the failure load and extends stably under increasing load before becoming unstable at a critical length of 2-3mm (depends on specimen geometry). This damage growth and failure are analysed by a linear cohesive zone model. Using the independently measured laminate parameters of unnotched compressive strength and in-plane fracture toughness the model predicts successfully the notched strength as a function of hole size and width.

  • PDF

Effect of Porcine Cancellous Bones on Regeneration in Rats with Calvarial Defect (랫드의 두개골 결손부에서 돼지 해면질골이 골재생에 미치는 영향)

  • Yoo, Kyeong-Hoon;Kim, Se-Eun;Shim, Kyung-Mi;Park, Hyun-Jeong;Choi, Seok-Hwa;Kang, Seong-Soo
    • Journal of Life Science
    • /
    • v.20 no.8
    • /
    • pp.1207-1213
    • /
    • 2010
  • The purpose of this study was to evaluate the effect of porcine cancellous bone as a scaffold in a rat calvarial defect model. Critical-sized defects were created in 30 male Sprague-Dawley rats. The animals were divided into critical defect (CD, n=10), $\beta$-tricalcium phosphate (TCP) graft (BT, n=10) and porcine cancellous bone graft (PCB, n=10) groups. Each defect was filled with $\beta$-TCP mixed with fibrin glue or porcine cancellous bone powder mixed with fibrin glue. In the CD group, the defect was left empty. All rats were sacrificed at 8 weeks after bone graft surgery, and bone formation was evaluated by gross observation, plain radiography, micro-computed tomography scanning and histological evaluation. Repair of bone defect was the least in the CD group, and significant new bone formation was observed in the PCB group. Grafting of porcine cancellous bone was more efficient for regenerating new bone than grafting $\beta$-TCP.

Development of $^{192}Ir$ Small-Focal Source for Non-Destructive Testing Application by Using Enriched Target Material (고농축 표적을 이용한 비파괴검사용 $^{192}Ir$ 미세초점선원 개발)

  • Son, K.J;Hong, S.B.;Jang, K.D.;Han, H.S.;Park, U.J.;Lee, J.S.;Kim, D.H.;Han, K.D.;Park, C.D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.1
    • /
    • pp.31-37
    • /
    • 2007
  • A $^{192}Ir$ small-focal source has been developed by using the HANARO reactor and the radioisotope production facility at the Korea Atomic Energy Research Institute (KAERI). The small-focal source with the dimension of 0.5 mm in diameter and 0.5 mm in length was fabricated as an aluminum-encapsulated form by a specially designed pressing equipment. For the estimation of the radioactivity, neutron self-shielding and ${\gamma}-ray$ self-absorption effects on the measured activity was considered. From this estimation, it is realized that $^{192}Ir$ small-focal sources over 3 Ci activities can be produced from the HANARO. Field performance tests were performed by using a conventional source and the developed source to take images of a computer CPU and a piece of a carbon steel. The small-focal source showed better penetration sensitivity and geometrical sharpness than the conventional source does. It is concluded from the tests that the focal dimension of this source is small enough to maximize geometrical sharpness in the image taking for the close proximity shots, pipeline crawler applications and contact radiography.

Study on the Exposure Dose(mAs) and acquisition Image set up Density Display and Sensitivity of control Panel for the Digital Flat-Panel-Detector (디지털 평판형 검출기에서 Control Panel의 Density Display와 Sensitivity 설정이 조사선량(mAs)과 획득영상에 미치는 영향에 관한 연구)

  • Kim, Byung-Ki;Kim, Sang-Keun;Cha, Seon-Hwa;Choi, Jun-Gu;Lee, Jun;Kim, Min-Woo;Kim, Sun-Bae;Kim, Gyeong-Sun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.17-21
    • /
    • 2007
  • The purpose to recognize change of average pixel value of acquisition image by control panel's density and right set up method of speed (sensitivity) and exposure dose(mAs) change that dose in purpose digital flatpanel-detector. X -ray generator DHF-158H2(Hitachi, Japan). Detector CXDI 4OG(Canon, Japan), 12 : 1 grid and exposure ray 135 kVp, 250 mA, 10 ms. focus-detector distance 180 cm and used AEC mode. DICOM reflex analysis program used image J that is digital reflex analysis program that offer in United States America National Health Center(National Institutes of Health : NlH) phantom used chest phantom(Anthromorphic : Flukebrome.medicaI USA). An experiment chest phantom that consist by formation equivalence material use because density value( -3${\sim}$+3) in X-ray control panel and seep that is speed step(slow, medium, fast) each control experimentalize. image analysis reflex neted through an experiment using image j each image compare. These was change in dose according to slow, medium, fast and density's change in an experiment result. According to detector sensitivity and density condition set, dose was relationship dissimilarity 500% from 200%. The dose came highest when is density +3 to slow. and dose more increases gray scale's extent could know that rise. Could know whether how equipment set is important through this experiment. cause of disease which change by digital radiography system forward is thought to increase more, it is considered that suitable education by this and continuous interest about equipment need absolutely.

  • PDF

3.5 mm T-shaped LCP (Locking Compression Plate) Fixation for Unstable Distal Clavicular Fractures (3.5 mm T형 잠김 금속판을 이용한 원위 쇄골 골절의 치료 결과)

  • Lee, Churl-Woo;Kim, Hee-Chun;Roh, Jae-Young;Park, Young-Su
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.41-45
    • /
    • 2008
  • Purpose: To review the clinical and radiological results after an open reduction and internal fixation with a T-shaped LCP for unstable distal clavicle fractures. Materials and Methods: From February 2005 to June 2006, ten patients with distal clavicle Neer type II fractures were treated with an open reduction and internal fixation with a T-shaped LCP. Bony union was identified by plain radiography. The clinical results were analyzed according to the UCLA scoring system. Results: The mean time to fracture union was 9weeks and union was achieved in all cases. The mean UCLA score was 33.4 (30-35); excellent in 8 cases and good in 2 cases. In one case, loosening of one distal screw was occured and mild AC joint subluxation was observed in another case. Conclusion: 3.5 mm T-shaped LCP fixation is a useful technique for treating unstable distal clavicle fractures. This procedure provide stable fixation with no further AC joint injury.

Development of the Automated Ultrasonic Testing System for Inspection of the flaw in the Socket Weldment (소켓 용접부 결함 검사용 초음파 자동 검사 장비 개발)

  • Lee, Jeong-Ki;Park, Moon-Ho;Park, Ki-Sung;Lee, Jae-Ho;Lim, Sung-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.275-281
    • /
    • 2004
  • Socket weldment used to change the flow direction of fluid nay have flaws such as lack of fusion and cracks. Liquid penetrant testing or Radiography testing have been applied as NDT methods for flaw detection of the socket weldment. But it is difficult to detect the flaw inside of the socket weldment with these methods. In order to inspect the flaws inside the socket weldment, a ultrasonic testing method is established and a ultrasonic transducer and automated ultrasonic testing system are developed for the inspection. The automated ultrasonic testing system is based on the portable personal computer and operated by the program based Windows 98 or 2000. The system has a pulser/receiver, 100MHz high speed A/D board, and basic functions of ultrasonic flaw detector using the program. For the automated testing, motion controller board of ISA interface type is developed to control the 4-axis scanner and a real time iC-scan image of the automated testing is displayed on the monitor. A flaws with the size of less than 1mm in depth are evaluated smaller than its actual site in the testing, but the flaws larger than 1mm appear larger than its actual size on the contrary. This tendency is shown to be increasing as the flaw size increases. h reliable and objective testing results are obtained with the developed system, so that it is expected that it can contribute to safety management and detection of repair position of pipe lines of nuclear power plants and chemical plants.

Long-Term Survival of Patients with Lung Cancer Treated by Traditional Korean Medicine Combined with Western Treatment: Report of Two Cases (양한방 복합투여로 장기간 생존을 보인 폐암 환자 2례)

  • Kang, Ji-young;Kim, Jun-young;Son, Chang-gue;Cho, Jung-hyo
    • The Journal of Internal Korean Medicine
    • /
    • v.36 no.1
    • /
    • pp.58-68
    • /
    • 2015
  • Objectives : To evaluate the long-term survival effects of traditional Korean medicine (TKM) on refractory metastatic lung cancer and small cell lung cancer (SCLC), which have historically poor survival rates. Methods : A retrospective study was conducted using the medical records of two patients in Daejeon University hospital. The first patient, with SCLC, was treated from January 2000 to December 2009 and the other, with metastatic pulmonary cancer from primary hepatocellular carcinoma (HCC), was treated from September 2004 to February 2014. The patients were treated with herbal medicines at one-month intervals. During hospitalization, acupuncture and indirect moxibustion were performed concurrent with the administration of Western therapy. Treatment efficacy was assessed monthly using chest radiography, chest computed tomography, and laboratory examination data, and by measuring patient performance status. Results : Both patients exhibited a stable disease course for more than 9 years after the initial diagnosis of intractable lung cancer, suggesting that their disease status was controlled by TKM. Conclusions : We suggest that a combination of TKM with conventional Western therapy for refractory lung cancer patients is effective in controlling various symptoms related to lung cancer and improving quality of life, and may potentially prolong overall survival.

A Study on the Appropriate Reconstruction of the CBCT Images of Mandibular Canals (CBCT 영상에서 구치부의 하악관 형태에 따른 재구성 방법 연구)

  • Jeong, Cheon-Soo;Mo, Eun-Hee;Lee, Gee-Heun;Han, Beom-Hee;Kim, Seung-Chul;Kim, Jung-Sam;Lim, Cheong-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.369-375
    • /
    • 2011
  • In dental radiography, panoramic views cause distortion and thus may bring about inaccurate results in the process of quantitative analysis. In this connection, there has recently been an increasing use of cone beam computed tomography (CBCT) that is known to provide high-resolution images and positional information. In this study, a dental computed tomography unit, 'DCT-90-P IMPLAGRAPHY (Vatech, Korea)', was applied to 20 patients for 24 seconds respectively, with a tube voltage of 85kVp and a tube current of 7mA. The data of CBCT were three-dimensionally reconstructed by use of a computer program, and were histomorphometrically analyzed. The results showed that the diameter of mandibular canal is less distorted at a certain inclination of the mandibular body. The image tends to seem more distended in proportion to the distance between the subject and film. Also, the image tends to be affected according as it is out of focus. In conclusion, it requires that the image should be reconstructed in light of anatomic position and structure.

A Preliminary Study on Measuring Void Fraction in a Fuel Rod Assembly by using an X-ray Imaging System (X선 영상 장치를 이용한 핵연료 집합체 내 기포율 측정을 위한 선행 연구)

  • Lee, Sun-Young;Oh, Oh-Sung;Lee, Se-Ho;Lee, Seung-Wook
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.571-578
    • /
    • 2017
  • Bubbles are generated by the boiling of the cooling water when an accident occurs in the reactor and then in order to measure the void fraction, the Optical Fiber Probe(OFP) and optical camera are used in thermal hydraulic safety research. However, such an optical method is not suitable for measuring the void fraction in a $17{\times}17$ array of fuel rods due to the geometrical limitations. This study was conducted as a preliminary study using x-ray system and various phantoms before applying to rod bundles. Through radiographic and tomographic experiments, the tube voltage of the x-ray generator was 130 kVp and the tube current was 1 mA. In addition, it is possible to measure the hole of 1mm in size visually through the bubble resolution phantom, and it is confirmed that the contrast is relatively decreased in the inside of the freon in the case of the contrast evaluation using the road phantom. However, we could obtain good image without distortion when reconstructing the image. Bubble generation phantom experiments were used to confirm the flow direction of the bubbles and to acquire tomography images. The image J tool was used to measure the void fraction of 18 % for a single tomography image. This study has carried out previous researches for the measurement of the bubble rate around the nuclear fuel and could be used as a basic research for continuous research.

Effects of Field Configuration Shielding Area and Changing of Density and Sensitivity on Tube Current and Image Quality in Automatic Exposure Control System (자동노출제어장치의 채광창 차폐정도와 농도, 감도의 변화가 관전류량과 영상품질에 미치는 영향)

  • Jeong, Min-Gyu;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.635-642
    • /
    • 2020
  • The purpose of this study was to analysis the effects of shielding area of field configuration with changing of sensitivity and density on tube current (milliampere-seconds, mAs) and image quality in automatic exposure control (AEC) system. The equipment used a digital radiography device (Digital Diagnost, Philips, Netherlands), which has a integral type with an X-ray tube and an indirect digital detector. The AEC system conditions were consisted of 9 setting environments, that mode changing of the sensitivity (S200, S400, S800) and the density (+2.5, 0, -2.5). The tube current evaluated automatically exposed mAs under 81 combination conditions crossed by AEC conditions in fixed at 40 kVp. The image quality evaluated the radiographic images that selected valid images by visual assessment the radiographic images of the self-produced conical pyramid phantom and then measured their signal to noise ratio (SNR). As a result, the maximum tube current was 60.0 mAs that automatically exposed conditions were the 100% of shielding area and the sensitivity of S200 and the density of +2.5. The minimum tube current was 0.9 mAs with non-shielding area and the sensitivity of S800 and the density of -2.5. When the shielded area 0% with the sensitivity of S200 and the density of +2.5, the maximum SNR was the highest as 25.2. But when the shielded area 25% with the sensitivity of S800 and the density of -2.5, the minimum SNR was the lowest as 4.7.