• Title/Summary/Keyword: radiography%2C dental%2C digital

Search Result 3, Processing Time 0.019 seconds

The Actual State and the Utilization for Dental Radiography in Korea (국내 치과방사선의 현황 및 이용 실태)

  • Shin, Gwi-Soon;Kim, You-Hyun;Lee, Bo-Ram;Kim, Se-Young;Lee, Gui-Won;Park, Chang-Seo;Park, Hyok;Chang, Kye-Yong
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.109-120
    • /
    • 2010
  • The purpose of this study was first to analyze the utilization of dental examination through questionnaire to develop a diagnostic reference level of patient doses for dental radiography in korea. 77 dental institutions were classified into three groups: A group for the dental hospitals of the college of dentistry (11 institutions), B group for dental hospitals (30 institutions) and C group for dental clinics (36 institutions). The results were as follows : The mean numbers of unit chairs and medical staffs were 140.2, 15.3 and 5.8 sets, 112.6, 7.3 and 1.7 dentists, 3.1, 0.5 and no one radiologic technologists, and 19.7, 12.5 and 3.3 dental hygienists in A, B and C groups, respectively. The mean numbers of dental X-ray equipments were 14.64, 3.21 and 2.19 in A, B and C groups, respectively. Intraoral dental X-ray unit was used the most, the following equipments were panoramic, cephalometric, and cone-beam CT units. The most used X-ray imaging system was also digital system (above 50%) in all three groups. Insight dental film (Kodak, USA) having high sensitivity was routinely used for periapical radiography. The automatic processor was not used in many dental institutions, but the film-holding device was used in many dental institutions. The utilization rates of PACS in A, B and C groups were 90.9%, 83.3% and 16.7% respectively, and the PACS software program was used the most PiView STAR (Infinitt, Korea). The annual mean number of radiographic cases in one dental institution in 2008 for A group was 6.8 times and 21.2 times more than those for B and C groups, and periapical and panoramic radiographs were taken mostly. Tube voltage (kVp) and tube current (mA) for periapical radiography were similar in all three groups, but exposure time in C group was 12.0 times and 3.5 times longer than those in B and C groups. The amount of radiation exposure in C group, in which dental hygienists take dental radiographs, was more than those in other groups. The exposure parameters for panoramic radiography were similar in all three groups. In conclusion, the exposure parameters in dental radiography should be determined with reference level, not past experiences. Use of automatic processor and film-holding devices reduces the radiation exposure in film system. The quality assurance of dental equipments are necessary for the reduction of the patient dose and the improvement of X-ray image quality.

The Characteristic of Temperature and Dose Distribution of intra oral X-ray Tube (강내형 X선 튜브 온도 및 선량 분포 특성)

  • Cho, Sungho;Lee, Rena
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.262-266
    • /
    • 2013
  • A new concept of periapical radiography, intra oral x-ray tube and detector system is introduced. It is new system that a miniature x-ray tube is inserted into mouse and it acquired digital image using external detector. In this study, we have investigated temperature and dose distribution of insertional x-ray tube for periapical radiography. To analyze temperature characteristic of x-ray tube, we attached the thermocouple to surface of x-ray tube and we measured the temperature according to distance. Also, we measured the dose distribution of a miniature x-ray tube according to distance. As a result, temperature was constant to $27^{\circ}C$ over 2mm without cooling system, dose distribution of x-ray tube was 3.14 and 1.84mGy in 3 and 5cm, respectively. Therefore, the proposed x-ray system works in lower dose than conventional dental x-ray system. Thus, it is considered that new concept of system will have a significant effect on medical imaging technology.

Clinicoradiologic evaluation of styloid process calcification

  • Bagga, Mun Bhawni;Kumar, C. Anand;Yeluri, Garima
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.155-161
    • /
    • 2012
  • Purpose: This study was performed to investigate the prevalence, morphology, and calcification pattern of the elongated styloid process in the Mathura population and its relation to gender, age, and mandibular movements. Materials and Methods: The study analyzed digital panoramic radiographs of 2,706 adults. The elongated styloid process was classified with the radiographic appearance based on the morphology and calcification pattern. The limits of mandibular protrusion were evaluated for each subject. The data were analyzed by using a Student's t-test and chi-squared test with significance set at p=0.05. Results: Bilateral elongation having an "elongated" type styloid process with a "partially mineralized" pattern was the most frequent type of styloid process. No correlation was found between styloid process type and calcification pattern on the one hand and gender on the other, although elongated styloid was more prevalent in older and male populations (p<0.05). Further styloid process elongation showed no effect on mandibular protrusive movement (p>0.05). Conclusion: Dentists should recognize the existence of morphological variation in elongated styloid process or Eagle syndrome apparent on panoramic radiographs. We found higher prevalence of elongated styloid process in the population of the Mathura region when compared with other Indian populations. The calcification of the styloid process was more common in the older age group with no correlation to gender, mandibular movement and site. "Type I" with a "partially calcified" styloid process was observed more frequently in the population studied.