• 제목/요약/키워드: radiochemical analysis

검색결과 35건 처리시간 0.017초

Biodistribution of 99mTc Labeled Integrin Antagonist

  • Jang, Beom-Su;Park, Seung-Hee;Shin, In Soo;Maeng, Jin-Soo;Paik, Chang H.
    • Toxicological Research
    • /
    • 제29권1호
    • /
    • pp.21-25
    • /
    • 2013
  • The selective targeting of an integrin ${\alpha}_v{\beta}_3$ receptor using radioligands may enable the assessment of angiogenesis and integrin ${\alpha}_v{\beta}_3$ receptor status in tumors. The aim of this research was to label a peptidomimetic integrin ${\alpha}_v{\beta}_3$ antagonist (PIA) with $^{99m}Tc(CO)_3$ and to test its receptor targeting properties in nude mice bearing receptor-positive tumors. PIA was reacted with tris-succinimidyl aminotriacetate (TSAT) (20 mM) as a PIA per TSAT. The product, PIA-aminodiacetic acid (ADA), was radiolabeled with $[^{99m}Tc(CO)_3(H_2O)_3]^{+1}$, and purified sequentially on a Sep-Pak C-18 cartridge followed by a Sep-Pak QMA anion exchange cartridge. Using gradient C-18 reverse-phase HPLC, the radiochemical purity of $^{99m}Tc(CO)_3$-ADA-PIA (retention time, 10.5 min) was confirmed to be > 95%. Biodistribution analysis was performed in nude mice (n = 5 per time point) bearing receptor-positive M21 human melanoma xenografts. The mice were administered $^{99m}Tc(CO)_3$-ADA-PIA intravenously. The animals were euthanized at 0.33, 1, and 2 hr after injection for the biodistribution study. A separate group of mice were also co-injected with 200 ${\mu}g$ of PIA and euthanized at 1 hr to quantify tumor uptake. $^{99m}Tc(CO)_3$-ADA-PIA was stable in phosphate buffer for 21 hr, but at 3 and 6 hr, 7.9 and 11.5% of the radioactivity was lost as histidine, respectively. In tumor bearing mice, $^{99m}Tc(CO)_3$-ADA-PIA accumulated rapidly in a receptor-positive tumor with a peak uptake at 20 min, and rapid clearance from blood occurring primarily through the hepatobiliary system. At 20 min, the tumor-to-blood ratio was 1.8. At 1 hr, the tumor uptake was 0.47% injected dose (ID)/g, but decreased to 0.12% ID/g when co-injected with an excess amount of PIA, indicating that accumulation was receptor mediated. These results demonstrate successful $^{99m}TC$ labeling of a peptidomimetic integrin antagonist that accumulated in a tumor via receptor-specific binding. However, tumor uptake was very low because of low blood concentrations that likely resulted from rapid uptake of the agent into the hepatobiliary system. This study suggests that for $^{99m}Tc(CO)_3$-ADA-PIA to be useful as a tumor detection agent, it will be necessary to improve receptor binding affinity and increase the hydrophilicity of the product to minimize rapid hepatobiliary uptake.

Generator 컬럼용 68GeO2 합성 및 68Ga3+의 거동에 관한 연구 (Study on Synthesis of 68GeO2 and Behavior of 68Ga3+ for Generator Column)

  • 김건균;이준영;김상욱;허민구;양승대;박정훈
    • 방사선산업학회지
    • /
    • 제10권4호
    • /
    • pp.189-192
    • /
    • 2016
  • $^{68}Ga$ has emerged as a promising candidate for non-invasive diagnostic imaging within Positron Emission Tomography (PET) because of its advantageous radiochemical characteristics ($t_{1/2}=68min$, ${\beta}^+$ yield ~89%). $^{68}Ga$ forms a stable chelation with various ligands and it is possible to be quickly and easily study using a $^{68}Ge/^{68}Ga$ generator. Commercial $^{68}Ge/^{68}Ga$ generators are chromatographic system using the inorganic materials such as alumina and tin dioxide which are employed as column matrixes for $^{68}Ge$. In this study, we tried out to make $^{68}Ge/^{68}Ga$ generator system with the $^{68}GeO_2$ microstructures for column matrix. $^{68}Ge$ tends to have stable bond with oxide as $^{68}GeO_2$ microstructures. The $^{68}GeO_2$ has been synthesized by hydrolysis of $GeCl_4$ (sol-gel method) and characterized by X-ray diffraction and scanning electron microscope for geometrical analysis. The stability of $GeO_2$ was tested using eluents with diverse solvents(water, ethanol and 0.1 N HCl). The radioactivity of $^{68}Ga^{3+}$ in eluate through $GeO_2$ was measured to prove a function as column material for a generator.

Comparison and evaluation of 89Zr-labeled trastuzumab and Thio-trastuzumab : a potential immuno-PET probe for HER2-positive carcinomas

  • Un Chol Shin;Seoku Bae;Suk-man Kim;Min-Woo Lee;Han Sang Jin;Hyun Park;Kyo Chul Lee;Jung Young Kim;Ji Woong Lee
    • 대한방사성의약품학회지
    • /
    • 제7권2호
    • /
    • pp.105-111
    • /
    • 2021
  • 89Zr is a positron-emitting radioisotope, which has known as well-suited radioisotope for use in a monoclonal antibody-based imaging agent for immuno-PET. The purpose of this study was to quantitatively evaluate the diagnostic ability of general trastuzumab and thio-trastuzumab as HER2 positive receptors based on Df hexadentate iron chelator. Desferrioxamine-p-SCN (Df-Bz-NCS) and desferroixamine-maleimide (Df-Mal) were purchased from Macrocyclics (Dallas, TX, USA). The trastuzumab was purchased from Roche (Schweiz), and thio-trastuzumab was obtained from professor Hyo-Jeong Hong group (Kangwon National University). The radioisotope 89Zr was produced by domestic purification system and KIRAMS using medical cyclotron (50 MeV, Scantronix). The conjugates of Df-trastuzumab and Df-thio-trastuzumab were prepared with Df-Bz-NCS and Df-Mal under basic aqueous solution (pH 8-9) at room temperature, respectively. The conjugates purified by PD-10 column were mixed with dried 89Zr chloride. 89Zr-labeled conjugates were purified and concentrated by Amicon ultra centrifugal filter. The preparation step and time of 89Zr-labeled conjugates was shorted as 4 steps within 2 hours. 89Zr-labeled conjugates showed the highly radiochemical purity of over 98%, and were very stable until 7 days by the analysis of radio-ITLC method. Each radio-labeled conjugates were also exhibited the highly stability in both PBS buffer and mouse serum. Immuno-PET imaging of 89Zr-labeled conjugates in mice bearing gastric cancer xenograft tumors with HER2 expression showed high tumor uptake in the NCI-N87 HER2-expressing. However, 89Zr-Df-Mal-thio-trastuzumab showed a relatively lower tumor-to-background ratio than 89Zr-Df-Bz-trastuzumab, as well as whole-body distribution. In the results, 89Zr-Df-Bz-trastuzumab was evaluated to have a relatively higher HER2 diagnostic ability than 89Zr-Df-Mal-thio-trastuzumab.

혈중 대식세포 유주 저지 인자 측정을 위한 방사면역측정법 (Radioimmunoassay for Determination of Serum Macrophage Migration Inhibitory Factor)

  • 이태섭;신석환;송지인;우광선;정위섭;최창운;임상무
    • 대한핵의학회지
    • /
    • 제38권6호
    • /
    • pp.532-539
    • /
    • 2004
  • 목적: 사람 대식세포 유주 저지 인자는 많은 감염성 질환에 의한 패혈증의 병인론과 숙주의 염증 및 면역 반응의 조절에 중요한 역할은 하는 것으로 알려져 있다. 본 연구에서는 사람의 혈중에서 대식세포 유주 저지 인자를 측정할 수 있는 방사면역측정법을 개발하고자 하였다. 대상 및 방법 : 사람 대식세포 유주저지 인자에 대한 단클론 항체를 포획항체로, 비오틴화된 다클론항체를 검출 항체로 사용하였다. 사람 대식세포 유주 저지인자를 검출하기 위하여 스트렙타비딘에 $^{125}I$를 방사성추적자로 사용하고 재조합 사람 대식세포 유주저지인자를 이용하여 표준투여 응답곡선을 작성하였다. 스트렙타비딘에 $^{125}I$의 표지는 Chloramine-T법을 사용하고, 분리정제는 한외여과법을 사용하였다. $^{125}I$-스트렙타비딘의 안정성을 60일까지 평가하였다. 표지수율과 안정성은 ITLC법을 사용하였다. 방사면역측정법의 유용성은 intra- 와 inter-assay의 변이계수 측정, 재현도 및 희석 실험 등을 시행하였다. 결과: $^{125}I$-스트렙타비딘의 표지수율은 88%이었으며, 분리 정제된 $^{125}I$-SA의 방사화학적 수율은 99%였다. $^{125}I$-스트렙타비딘는 60일까지 93%의 안정성을 나타내어 방사면역측정의 방사성추적자로 사용하는데 적합하였다. 작성된 표준투여 응답곡선에서 재조합 사람 대식세포 유주 저지 인자의 농도와 결합된 $^{125}I$-스트렙타비딘의 방사능 값은 높은 상관관계를 나타내었다($R^2=0.99$). 가장 높은 intra-와 inter-assay의 변이계수 간이 각각 5.5%와 7.6%로 나타났다. 시료 내에서 평균 recovery 측정값은 102%였다. 시료의 농도 희석에 따른 방사능의 측정치는 직선적인 상관관계를 나타내었다($R^2=0.97$). 결론: 대식세포 유주 저지 인자의 농도 측정을 위하여 방사성추적자로 $^{125}I$-스트렙타비딘를 이용한 방사면역측정법을 확립하였으며, 이 방법을 이용하여 다양한 염증성 질환을 가진 임상환자에서 대식세포 유주 저지 인자의 혈중 농도와 임상적 의의와의 상관관계를 규명하는데 이용될 수 있을 것으로 기대된다.

Loop와 HPLC Purification 방법보다 더 높은 비방사능을 보여주는 카트리지 Methylation과 Purification을 이용한 손쉬운 [ 11C]PIB 합성 (Facile [11C]PIB Synthesis Using an On-cartridge Methylation and Purification Showed Higher Specific Activity than Conventional Method Using Loop and High Performance Liquid Chromatography Purification)

  • 이용석;조용현;이홍재;이윤상;정재민
    • 핵의학기술
    • /
    • 제22권2호
    • /
    • pp.67-73
    • /
    • 2018
  • $[^{11}C]PIB$는 베타아밀로이드($A{\beta}\;plague$)라는 변성 단백질에 결합하여 뇌의 기능과 기억력을 서서히 감퇴시키는 비가역적인 질환인 치매를 조기에 감별할 수 있는 대표적인 방사성의약품이다. 지금까지 많은 실험실에서 $[^{11}C]PIB$는 자동화합성장치에서 $[^{11}C]methyl\;iodide$$[^{11}C]methyl\;triflate$를 만든 다음 loop나 vial 방법을 사용하여 methylation을 한 다음 HPLC로 정제를 하는 것이다. 하지만 기존의 보고된 방법은 시간이 오래 걸리며, HPLC와 같은 복잡한 시스템을 필요로 하여 소규모 실험실에서 합성하기에 적합하지 않으며, 최종 product에서 에탄올 함량이 높다는 단점이 있었다. 이러한 단점을 보완하기 위하여 카트리지만을 사용하여 카트리지에서 methylation과 purification을 동시에 실시함으로써 합성 시간을 단축하고, 비방사능이 높고, 낮은 에탄올 함량을 가진 $[^{11}C]PIB$를 합성 가능한지 확인하고자 하였다. 가장 널리 사용하는 카트리지 6종(CM, HLB, Alumina, C18, tC18, tC18 environmental을 선택하여 screening test를 실시하였다. 6-OH-BTA-0 1 mg을 c-HXO에 녹인 다음 6개의 카트리지에 loading를 한 다음 0.5 M MSP(pH 5.1) 20 mL로 정제를 한 다음 최종 fraction을 받아서 analytical HPLC로 전구체 잔류량을 측정한 결과 hydrophobicity가 낮은 계열(CM, HLB, Alumina)의 카트리지에서는 완충액으로 정제를 하였을 때 잔류전구체의 양이 많았으나, 탄소함량이 많은 계열의 카트리지(C18, tC18, tC18 environmental)에서는 잔류전구체의 양이 CM, HLB, Alumina 카트리지에 비하여 상대적으로 적었다. 완충액의 정제 농도와 부피를 최적화 하기 위하여 screening test에서 가장 좋은 결과를 나타낸 C18 series cartridge를 가지고 추가 실험을 진행하였다. 인산완충액 농도를 10 mM, 20 mM, 30 mM, 40 mM, 50 mM, 250 mM, 500 mM로 변화시켰으며, 에탄올 함량은 20%와 30%로 하여 용출액을 분석하여서, $[^{11}C]PIB$를 카트리지로 합성하기 위한 최적의 조합은 tC18 environmental cartridge와 0.5 M MSP 20 mL인 것을 알 수 있었다. 기존에 보고된 방법과 cartridge를 비교한 결과, 합성시간에서는 각각 15 ~ 18min, 8 ~ 9 min이 소요되었으며, product activity는 각각 $4.1{\pm}1.4\;GBq$ (n=41), $3.8{\pm}0.9\;GBq$ (n=3), 방사화학적 수율(based on HPLC analysis of the crude product)에서는 $13.9{\pm}4.4%$ (n=41), $12.3{\pm}2.2%$ (n=3)로 별다른 차이가 없었으며, 비방사능에 있어서는 HPLC purification method가 $78.7{\pm}39.7\;GBq/{\mu}mol$ (n=41), cartridge method가 $420.6{\pm}20.4\;GBq/{\mu}mol$ (n=3)로 카트리지 방법이 기존 방법보다 더 좋은 결과를 나타내었다. 또한, 잔류 용매(c-HXO)도 vial or loop method와 별다른 차이가 없었으며, 에탄올 함량에 있어서는 70%(기존 방법)에서 30%(카트리지 방법)로 두 배 이상 함량이 적다는 사실을 알 수 있었다. 지금까지 알아본바와 같이 cartridge method는 reported method(HPLC purification)에 비하여 더 향상된 결과를 보여준다는 사실을 확인하였다.