방사성동위원소의 지구물리학적 응용에 관한 연구 γ-γ 검층법에 의한 지층구조에 관한연구 (Study on the Geophysical Research Applications Using Radioactive Isotopes (I) Study on the Structures in Strata by Using γ-γ Logging Apparatus)

  • 이현덕;노성기
    • 자원환경지질
    • /
    • 제9권3호
    • /
    • pp.135-141
    • /
    • 1976
  • The gamma-gamma logging method appplying in geophysical research are presented in this paper_ The logging probe assembly was designed which permits changing the source-to-detector spacing while conditions of proceeding ${\gamma}-{\gamma}$ logging, which a collimated gamma ray source ($^{60}Co$, 0.5mCi and/or 2 mCi) is separated from the scintillation detector as shown in Fig. 2 and 3, size is 6.0 cm in diameter and 120.0 cm in long and the exposed parts are made of stainless steel pipe. The results is confirmed by the experiment performed mainly in granite rock where a slightly constant shape was obtained but sometimes was shown sharpness shape for the measured scattered gamma-ray intensity. Consequently, the experimental results are obtained an adequate intensity of scattered gamma-rays and favourable response to density change, and also very closely correspond to between core samples of the test boring and to used this method of ${\gamma}-{\gamma}$ logging in the test bore-hole of the strata.

  • PDF

나트륨-버네사이트를 이용한 수용액상의 세슘 및 스트론튬 제거에 관한 연구 (A study on removal of cesium and strontium from aqueous solution using synthetic Na-birnessite)

  • 조윤철;설빛나
    • 상하수도학회지
    • /
    • 제27권2호
    • /
    • pp.155-164
    • /
    • 2013
  • The main purpose of this research was to examine the adsorption/ion exchange characteristics of radioactive species such as cesium and strontium onto synthetic Na-birnessite (sodium-birnessite). As part of efforts to investigate the sorption behavior of cesium and strontium onto synthetic Na-birnessite, batch isotherm tests were performed under different experimental conditions. Na-birnessite was synthesized by the oxidation of $Mn^{2+}$ ions in sodium hydroxide solution. The synthetic Na-birnessite was characterized by powder x-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive x-ray spectroscopy (EDS), and Brunauer-Emmett-Teller (BET) surface area analysis. Cesium and strontium concentrations were determined by atomic absorption spectroscopy (AAS). The removal efficiency of strontium by Na-birnessite was around 95 % which was much higher than that of cesium (~ 32 %). The results imply that strontium has a higher affinity for Na-birnessite than cesium because strontium, divalent cation leads to larger electrostatic attraction than monovalent cesium.

Background reduction by Cu/Pb shielding and efficiency study of NaI(TI) detector

  • Ramadhan, Revink A.;Abdullah, Khairi MS.
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.462-469
    • /
    • 2018
  • The background spectrum of a $3^{{\prime}{\prime}}{\times}3^{{\prime}{\prime}}$ NaI(Tl) well-type scintillation SILENA detector was measured without shielding, in 6 cm thick lead shielding, and with 2 mm thick electrolytic copper covering the detector inside the lead shielding. The relative remaining background of the lead shield lined with copper was found to be ideal for low-level environmental radioactive spectroscopy. The background total count rate in the (20-2160 KeV) was reduced 28.7 times by the lead and 29 times by the Cu + Pb shielding. The effective reduction of background (1.04) by the copper mainly appeared in the energy range from X-ray up to 500 KeV, while for the total energy range the ratio is 1.01 relative to the lead only. In addition, a strong relation between the full-energy peak absolute efficiency and the detector well height was found using gamma-ray isotropic radiation point sources placed inside the detector well. The full-energy peak efficiency at a midpoint of the well (at 2.5 cm) is three times greater than that on the detector surface. The energy calibrations and the resolution of any single energy line are independent of the locations of the gamma source inside or outside of the well.

Design and Fabrication of CLYC-Based Rotational Modulation Collimator (RMC) System for Gamma-Ray/Neutron Dual-Particle Imager

  • Kim, Hyun Suk;Lee, Jooyub;Choi, Sanghun;Bang, Young-bong;Ye, Sung-Joon;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • 제46권3호
    • /
    • pp.112-119
    • /
    • 2021
  • Background: This work aims to develop a new imaging system based on a pulse shape discrimination-capable Cs2LiYCl6:Ce (CLYC) scintillation detector combined with the rotational modulation collimator (RMC) technique for dual-particle imaging. Materials and Methods: In this study, a CLYC-based RMC system was designed based on Monte Carlo simulations, and a prototype was fabricated. Therein, a rotation control system was developed to rotate the RMC unit precisely, and a graphical user interface-based software was also developed to operate the data acquisition with RMC rotation. The RMC system was developed to allow combining various types of collimator masks and detectors interchangeably, making the imaging system more versatile for various applications and conditions. Results and Discussion: Operational performance of the fabricated system was studied by checking the accuracy and precision of the collimator rotation and obtaining modulation patterns from a gamma-ray source repeatedly. Conclusion: The prototype RMC system showed reliability in its mechanical properties and reproducibility in the acquisition of modulation patterns, and it will be further investigated for its dual-particle imaging capability with various complex radioactive source conditions.

Evaluation of gamma-ray and neutron attenuation properties of some polymers

  • Kacal, M.R.;Akman, F.;Sayyed, M.I.;Akman, F.
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.818-824
    • /
    • 2019
  • In the present work, we determined the gamma-ray attenuation characteristics of eight different polymers(Polyamide (Nylon 6) (PA-6), polyacrylonitrile (PAN), polyvinylidenechloride (PVDC), polyaniline (PANI), polyethyleneterephthalate (PET), polyphenylenesulfide (PPS), polypyrrole (PPy) and polytetrafluoroethylene (PTFE)) using transmission geometry utilizing the high resolution HPGe detector and different radioactive sources in the energy range 81-1333 keV. The experimental linear attenuation coefficient values are compared with theoretical data (WinXCOM data). The linear attenuation coefficient of all polymers reduced quickly with the increase in energy, at the beginning, while decrease more slowly in the region from 267 keV to 835 keV. The effective atomic number of PVDC and PTFE are comparatively higher than the $Z_{eff}$ of the remaining polymers, while PA-6 possesses the lowest effective atomic number. The half value layer results showed that PTFE ($C_2F_4$, highest density) is more effective to attenuate the gamma photons. Also, the theoretical results of macroscopic effective removal cross section for fast neutrons ($\sum_{R}$) were computed to investigate the neutron attenuation characteristics. It is found that the $\sum_{R}$ values of the eight investigated polymers are close and ranged from $0.07058cm^{-1}$ for PVDC to $0.11510cm^{-1}$ for PA-6.

치아의 전베타 농도 및 감마선 방사능 평가 (Determination of Gross-${\beta}$ and ${\gamma}$-Ray Activity Concentrations of Human Tooth)

  • 정현자;강현경;김성환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권4호
    • /
    • pp.261-265
    • /
    • 2014
  • 10세에서 70세까지 국내 남녀를 7개 연령대별 그룹으로 구분한 후, 치아의 감마선 농도와 각 그룹별 전${\beta}$ 방사능 농도를 측정하였다. 전${\beta}$ 농도는 P10가스(아르곤 90%, 메탄 10%)를 충진한 Tennelec XLB 측정기로 측정하였으며, 감마선은 고순도 게르마늄 검출기를 사용하여 감마선분광분석법으로 측정하였다. 본 실험에서 측정된 여성의 전${\beta}$ 방사능 농도범위는 0.089~0.32 Bq/kg이었으며, 남성의 전${\beta}$ 방사능 농도범위는 0.13~0.26 Bq/kg이었다. 치아의 감마선분광분석 결과 자연방사성동위원소인 $^{40}K$, $^{208}Tl$, $^{228}Ac$$^{234}Th$가 검출되었으며, 측정된 감마선 방사선 농도는 각각 20.7, 21.9 3.88 및 5.24 Bq/kg 이었다. 본 연구 결과는 향후 후쿠시마 원전사고 등 불의의 방사선 누출 사고 등에 대비하여 정상 환경에서의 인체의 치아에 축적된 방사능 준위 데이터로 활용할 수 있을 것으로 사려된다.

즉발감마선 측정을 위한 HPGe 검출기의 전계수 또는 동시계수모드에서의 광대역 계측효율 보정 (Efficiency Calibration of HPGe Detector in Normal ana Coincidence Mode for the Determination of Prompt Gamma-ray)

  • 송병철;박용준;지광용
    • 방사성폐기물학회지
    • /
    • 제2권2호
    • /
    • pp.97-104
    • /
    • 2004
  • NIPS 시스템은 중성자 핵반응 결과 방출되는 즉발 감마선을 정량적으로 측정하는 장치이며 고체 및 액체 폐기물 중 존재하는 다양한 원소를 비파괴적으로 분석할 수 있는 장점이 있다. 본 연구에서는 NIPS 시스템에 이용된 고순도반도체 검출기의 계측효율을 $^{l33}$Ba 및 $^{152}$Eu 방사성 동위원소 선원과 $^{35}$ Cl(n, ${\gamma}$)$^{36}$ Cl 핵반응 시 발생되는 즉발감마선을 이용하여 80 keV에서 8 MeV까지 넓은 영역에 대하여 구하였다. $^{35}$ Cl(n, ${\gamma}$)$^{36}$ Cl 핵반응을 이용한 고에너지 감마선의 계측효율은 즉발감마선의 방사능 값을 정확히 알 수 없기 때문에 저 에너지 영역에서 정확히 알고 있는 검출기 효율곡선에 규격화시켜 전 에너지 영역에서의 효율보정곡선을 구하였다. 또한 KCl 표준용액에 $^{252}$ Cf 중성자 선원을 조사시켜 표준용액으로부터 방출되는 즉발 감마선을 고순도반도체 검출기로 측정하고 광대역 계측효율 곡선을 이용하여 수용액 시료에서의 평균 열중성자 속을 예측하였다. NIPS 측정시스템은 주변 재료 물질의 핵반응으로 방출되는 감마선 background를 줄이기 위해 두 개의 고순도반도체 검출기를 이용한 동시계수 장치가 고안되었으며, 동시계수 모드에서의 계측효율도 함께 고려되었으며, 표준선원을 이용하여 전 계수 또는 동시계수모드에서의 background에 대한 측정감도를 비교하였다.다.

  • PDF

마이크로포커스 X-선 투과 영상을 이용한 모의 TRISO 핵연료 입자 코팅 층 두께 비파괴 측정 (Nondestructive Measurement of the Coating Thickness in the Simulated TRISO-Coated Fuel Particle Using Micro-Focus X-ray Radiography)

  • 김웅기;이영우;박지연;박정병;나성웅
    • 비파괴검사학회지
    • /
    • 제26권2호
    • /
    • pp.69-76
    • /
    • 2006
  • 차세대 원자로로 부각되고 있는 고온가스로에서는 윈자로에서는 고온 안정성 및 핵분열생성물 차단 성능이 우수한 TRISO(tri-isotropic) 핵연료를 사용하고 있다. TRISO 핵연료 입자는 직경이 약 1mm인 구 형태로 입자의 중심에는 직경 0.5mm의 핵연료 커널(kernel)이 포함되며 커널 외곽을 코팅 층이 에워싸고 있다. 이 코팅 층은 완충(buffer) PyC(pyrolytic carbon)층, 내부 PyC층, SiC층, 그리고 외부 PyC층으로 구성되어 있다. 각 코팅 층의 두께는 수십-백${\mu}m$ 범위이고 사양으로 정해져 있으며, 본 연구에서는 각 코팅 층의 두께를 비파괴적으로 측정하기 위하여 마이크로포커스 X-선 발생장치와 고해상도 X-선 평판(flat panel) 검출기초 구성된 정밀한 X-선 래디오그래피 장치를 개발하였다. 개발된 마이크로 X-선 래디오그래피 장치를 이용하여 $UO_2$ 핵물질 $ZrO_2$를 커널로 사용한 모의 TRISO 핵연료 입사에 대한 투과 영상을 획득한 후 디지털 영상처리 기술을 이용하여 코팅 층 사이의 경계선이 구분 가능하도록 영상을 개선하고 디지털 영상처리 알고리듬을 개발하여 코팅 층의 두께를 파동으로 측정하였다.

미소 초점 X선 CT를 이용한 암석 내 공극의 분포 및 공극률 분석 (Analysis of Porosity and Distribution of Pores in Rocks by Micro Focus X-Ray CT)

  • 정교철
    • 지질공학
    • /
    • 제20권4호
    • /
    • pp.461-465
    • /
    • 2010
  • 암석에서의 풍화 및 투수성은 방사성폐기물 지하동굴처분 및 암반구조물의 안정성 확보 및 장기적 관리측면에서 매우 중요한 역할을 한다. 이들 암석의 풍화 및 투수성은 암석의 내 구조 특성에 따라 크게 영향을 받는다. 즉 암석 내부의 공극, 미소 크랙 등의 양적 정도에 의해 풍화가 빨리 진행되기도 한다. 또한 암석 내부구조의 양적 평가는 그 암석의 풍화 정도를 정량적으로 평가할 수 있는 수단이 되기도 한다. 따라서 암석의 내부구조를 3치원적으로 정확하게 파악한다는 것은 암반구조물의 장기적 관리 측면에서 매우 중요하다고 하겠다. 이 연구는 국내 신선한 화강암과 풍화된 화강암을 대상으로 X선 CT촬영을 실시하여 3차원으로 공극의 분포를 분석하였다. 분석 결과는 암석 내부의 공극의 분포와 공극률을 잘 표현하고 있다.

배관 내부 방사능 오염도 측정용 ZnS(Ag)/BC-408 phoswich 검출기 개발 (Development of the ZnS(Ag)/BC-408 phoswich detector for monitoring radioactive contamination inside pipes)

  • 김계홍;박찬희;정종헌;이근우;서범경
    • Journal of Radiation Protection and Research
    • /
    • 제31권3호
    • /
    • pp.123-128
    • /
    • 2006
  • 원자력 시설의 해체 시 발생되는 다양한 종류의 폐기물 중에서 배관 내부의 알파/베타선 오염 특성을 직접 평가하기 위해서는 소형의 방사선 검출 시스템이 요구된다. 본 연구에서는 배관 내부의 방사능 오염도를 직접 측정할 수 있는 장비 개발의 일환으로서 기존의 phoswich 검출기와 그 형태가 다른 ZnS(Ag)/플라스틱섬광체 조합의 알파/베타선 동시측정용 phoswich 검출기를 고안하였으며 섬광체 크기 및 검출 시스템의 최적 요건을 실험적으로 확인하고 알파/베타선 신호 분리도를 평가하였다. 그 결과 배관 내부의 오염도 측정에 적합한 phoswich 검출기의 최적 요건 및 배관 내부의 적용 가능성을 확인하였다.