• 제목/요약/키워드: radiation treatment planning systems

검색결과 48건 처리시간 0.03초

Comparison of Dose Statistics of Intensity-Modulated Radiation Therapy Plan from Varian Eclipse Treatment Planning System with Novel Python-Based Indigenously Developed Software

  • Sougoumarane Dashnamoorthy;Karthick Rajamanickam;Ebenezar Jeyasingh;Vindhyavasini Prasad Pandey;Kathiresan Nachimuthu;Imtiaz Ahmed;Pitchaikannu Venkatraman
    • 한국의학물리학회지:의학물리
    • /
    • 제33권3호
    • /
    • pp.25-35
    • /
    • 2022
  • Purpose: Planning for radiotherapy relies on implicit estimation of the probability of tumor control and the probability of complications in adjacent normal tissues for a given dose distribution. Methods: The aim of this pilot study was to reconstruct dose-volume histograms (DVHs) from text files generated by the Eclipse treatment planning system developed by Varian Medical Systems and to verify the integrity and accuracy of the dose statistics. Results: We further compared dose statistics for intensity-modulated radiotherapy of the head and neck between the Eclipse software and software developed in-house. The dose statistics data obtained from the Python software were consistent, with deviations from the Eclipse treatment planning system found to be within acceptable limits. Conclusions: The in-house software was able to provide indices of hotness and coldness for treatment planning and store statistical data generated by the software in Oracle databases. We believe the findings of this pilot study may lead to more accurate evaluations in planning for radiotherapy.

Discrepancies in Dose-volume Histograms Generated from Different Treatment Planning Systems

  • Kim, Jung-in;Han, Ji Hye;Choi, Chang Heon;An, Hyun Joon;Wu, Hong-Gyun;Park, Jong Min
    • Journal of Radiation Protection and Research
    • /
    • 제43권2호
    • /
    • pp.59-65
    • /
    • 2018
  • Background: We analyzed changes in the doses, structure volumes, and dose-volume histograms (DVHs) when data were transferred from one commercial treatment planning system (TPS) to another commercial TPS. Materials and Methods: A total of 22 volumetric modulated arc therapy (VMAT) plans for nasopharyngeal cancer were generated with the Eclipse system using 6-MV photon beams. The computed tomography (CT) images, dose distributions, and structure information, including the planning target volume (PTV) and organs at risk (OARs), were transferred from the Eclipse to the MRIdian system in digital imaging and communications in medicine (DICOM) format. Thereafter, DVHs of the OARs and PTVs were generated in the MRIdian system. The structure volumes, dose distributions, and DVHs were compared between the MRIdian and Eclipse systems. Results and Discussion: The dose differences between the two systems were negligible (average matching ratio for every voxel with a 0.1% dose difference criterion = $100.0{\pm}0.0%$). However, the structure volumes significantly differed between the MRIdian and Eclipse systems (volume differences of $743.21{\pm}461.91%$ for the optic chiasm and $8.98{\pm}1.98%$ for the PTV). Compared to the Eclipse system, the MRIdian system generally overestimated the structure volumes (all, p < 0.001). The DVHs that were plotted using the relative structure volumes exhibited small differences between the MRIdian and Eclipse systems. In contrast, the DVHs that were plotted using the absolute structure volumes showed large differences between the two TPSs. Conclusion: DVH interpretation between two TPSs should be performed using DVHs plotted with the absolute dose and absolute volume, rather than the relative values.

세기조절방사선치료 시 치료 부위에 따른 치료계획 시스템 간 선량평가 (Dose Evaluation of TPS according to Treatment Sites in IMRT)

  • 김진만;김종식;홍채선;박주영;박수연;주상규
    • 대한방사선치료학회지
    • /
    • 제25권2호
    • /
    • pp.181-186
    • /
    • 2013
  • 목 적: 본 연구는 치료계획 시스템인 $Pinnacle^3$ (version 9.2, Philips Medical Systems, USA)과 Eclipse (version 10.0, Varian Medical Systems, USA)을 이용하여 전립선암과 폐암의 세기조절방사선 치료계획시 불균질 부위의 선량 계산 차이를 알고리즘별로 알아보고자 한다. 대상 및 방법: 각 5명의 전립선암 및 폐암 환자를 대상으로, 본원 Protocol에 따른 동일한 조건으로 최적화 계산을 진행하였다. 전립선암 환자의 치료계획은 10 MV, 7Beam을 사용하였으며 2.5 Gy씩 28 fx, 총 70 Gy를 동일 처방하였고, 폐암 환자의 치료계획은 6 MV, 6Beam을 사용하였으며 2 Gy씩 33 fx, 총 66 Gy를 동일 처방하였다. 두 치료계획시스템을 통해 CTV, PTV 및 종양주위의 OAR의 최대선량, 평균선량, 최소선량을 비교하였다. 결 과: 전립선암에서 두 치료계획시스템 모두 CTV와 PTV의 선량변화가 2%이내였으며 종양주변 정상 장기(방광, 대퇴골, 직장)도 선량제약조건을 충족하였다. 폐암에서도 CTV와 PTV는 2%이내의 선량변화를 보였고, 정상 장기(식도, 척수, 양측 폐)도 선량제약 조건을 충족하였다. 하지만, Eclipse 치료계획의 최소선량은 CTV에서 1.9%, PTV에서 3.5% 높았고 양측 폐의 경우 V5 Gy에서 3.0% 높은 차이를 보였다. 결 론: 치료부위에 따른 각각의 치료계획시스템은 본원의 선량제한 조건을 모두 만족하여 임상적 정확성을 확인할 수 있었다. 향후 다양한 부위의 치료계획 연구와 치료계획시스템의 적용은 보다 정확한 치료계획을 위한 방법을 제시할 것이라 사료된다.

  • PDF

Comparison of Linear Accelerator and Helical Tomotherapy Plans for Glioblastoma Multiforme Patients

  • Koca, Timur;Basaran, Hamit;Sezen, Duygu;Karaca, Sibel;Ors, Yasemin;Arslan, Deniz;Aydin, Aysen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권18호
    • /
    • pp.7811-7816
    • /
    • 2014
  • Background: Despite advances in radiotherapy, overall survival of glioblastoma multiforme (GBM) patients is still poor. Moreover dosimetrical analyses with these newer treatment methods are insufficient. The current study is aimed to compare intensity modulated radiation therapy (IMRT) linear accelerator (linac) and helical tomotherapy (HT) treatment plans for patients with prognostic aggressive brain tumors. Material and Methods: A total of 20 GBM patient plans were prospectively evaluated in both linac and HT planning systems. Plans are compared with respect to homogenity index, conformity index and organs at risk (OAR) sparing effects of the treatments. Results: Both treatment plans provided good results that can be applied to GBM patients but it was concluded that if the critical organs with relatively lower dose constraints are closer to the target region, HT for radiotherapeutical application could be preferred. Conclusion: Tomotherapy plans were superior to linear accelerator plans from the aspect of OAR sparing with slightly broader low dose ranges over the healthy tissues. In case a clinic has both of these IMRT systems, employment of HT is recommended based on the observed results and future re-irradiation strategies must be considered.

Merkel cell carcinoma in the community setting: a case report

  • Callaghan, Cameron M.;Amornmarn, Rumpa
    • Radiation Oncology Journal
    • /
    • 제36권2호
    • /
    • pp.163-170
    • /
    • 2018
  • Merkel cell carcinoma (MCC) is a rare neuroendocrine tumor of the skin initially believed to arise from the Merkel cells. In the community setting a general radiation oncologist may only encounter this pathology in a handful of cases over the course of their career. Due to the low incidence of this malignancy, few prospective randomized controlled trials have ever been conducted and therefore guidelines are based on relatively lower levels of evidence upon which the clinical recommendations are made. We discuss the case of a female in her 90s presenting with a classic MCC primary lesion, as well as satellite lesions proximal to both the primary and the draining regional lymph nodes with no evidence of nodal involvement. Here we discuss the presentation, management, treatment planning, underlying pathology, results and sequelae of treatment. We also review new treatment modalities, and the most current staging systems and guidelines.

가임기 여성의 방사선 치료 시 난소 선량 평가 (Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy)

  • 박성준;이영철;김선명;김영범
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.145-153
    • /
    • 2021
  • 목 적: 본 연구에서는 가임기 여성의 유방암 방사선 치료 시 난소 선량에 대해 실험을 통하여 평가해보고자 한다. 치료기법에 따른 치료계획시스템에서 계산된 선량과 열형광선량계를 이용한 측정선량을 비교·분석하여 난소 선량을 평가하고 납(Pb) 앞치마의 사용유무에 따른 선량 분석을 통해 임상에서의 유용성을 알아보고자 한다. 대상 및 방법: 측정에는 Rando humanoid phantom을 이용하였고, 치료기법으로는 쐐기필터치료기법, 3차원 입체조형치료, 세기변조방사선치료를 사용하였다. CT simulator를 이용하여 얻은 Rando humanoid phantom 3D 영상의 우측 유방에 처방선량의 95%가 전달될 수 있도록 치료계획을 세웠고, TLD를 Rando hunmanoid phantom의 가상 표적의 표면 및 심부에 삽입하고 방사선을 조사하였다. 측정위치는 치료 중심점과 Rando humanoid phantom의 정중앙을 중심으로 반대쪽 유방으로 2cm 이동한 지점과 치료 중심축 및 하방으로 우측 유방의 경계면에서 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm, 우측 난소 위치의 표면과 중심점을 포함하여 총 9개 지점에서 측정하였다. 치료계획시스템의 선량 비교에서는 쐐기필터치료기법 2가지와 3차원 입체조형치료, 세기변조방사선치료 등 총 4개의 치료 계획을 수립하여 비교하였다. 그리고 TLD를 이용한 측정값 비교는 세기변조방사선치료와 쐐기필터를 이용한 치료를 비교하였고, 납 앞치마의 사용유무에 따라서 세기변조방사선치료의 선량차이를 측정하여 비교·분석하였다. 측정값은 각 포인트마다 3개의 TLD값 평균을 내고 TLD 교정값을 이용하여 환산하였으며 이를 Point dose mean값으로 계산하였다. 치료계획값과 실제 측정값을 비교하기 위해 각 지점마다 절대선량값을 측정하여 %Diff 값으로 계산하였다. 결 과: 치료 중심점인 Point A에서는 치료계획시스템에서 최대 201.7cGy가 나왔고, 실제 TLD 측정값은 최대 200.6cGy가 나왔다. 모든 치료계획시스템에서 유방 경계면으로부터 하방으로 17.5cm 떨어진 지점인 Point G 부터는 0cGy로 계산이 되었다. 실제 TLD 측정 결과 Point G에서는 최대 2.6cGy가 나왔고, 난소선량인 Point J에서는 최대 0.9cGy로 나타났으며 %Diff값은 0.3%~1.3%였다. 납 앞치마의 사용유무에 따른 선량 차이는 최대 2.1cGy에서 최소 0.1cGy로 나타났으며 %Diff값은 0.1%~1.1%였다. 결 론: 치료계획시스템에서 3가지 치료계획에 따른 선량차이는 최저 0.85%에서 최고 2.45%로 큰 격차를 보이지 않았다. 난소에서 Rando humanoid phantom의 치료계획과 실제 측정한 선량차이는 0.9% 이내로 나타났으나 실제 측정에서 조금 더 높게 측정되었다. 이는 치료계획시스템에서 산란선의 영향을 정확하게 반영하지 못하였고, 실제 측정에서는 TLD를 삽입한 상태로 CBCT를 촬영한 선량과 산란선량이 반영된 것으로 사료된다. 납 앞치마의 유무에 따른 선량측정에서 납 앞치마를 사용했을 경우에 치료범위에서 가까운 거리일수록 차폐의 효과가 있었으며, 치료범위에서 15cm 이상 거리가 있는 경우에는 거의 영향을 미치지 않는 것으로 나타났다. 임상적으로 방사선 치료 중에는 임신이나 인공수정을 하기에는 적절하지 않지만, 치료 중 난소에 조사된 선량은 방사선 치료 후 가임기 여성의 생식 기능에 크게 영향을 주지 않을 것으로 생각된다. 하지만 가임 여성의 경우에는 지속적인 불안감을 가지고 있으므로 이번 결과를 통한 데이터를 제시함으로써 심리적인 안정을 도모할 수 있을 것으로 사료된다.

Proposal on Guideline for Quality Assurance of Radiation Treatment Planning System

  • Oh, Yoonjin;Shin, Dong Oh;Kim, Juhye;Kwon, Nahye;Lee, Soon Sung;Choi, Sang Hyoun;Ahn, Sohyun;Park, Dong-wook;Kim, Dong Wook
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.197-206
    • /
    • 2017
  • We develop guidelines for the quality assurance of radiation treatment planning systems (TPS) by comparing and reviewing recommendations from major countries and organizations, as well as by analyzing the AAPM, ESTRO, and IAEA TPS quality assurance guidelines. We establish quality assurance items for acceptance testing, commissioning, periodic testing, system management, and security, and propose methods to perform each item within acceptable standards. Acceptance includes tests of hardware and network environments, data transmission, software, and benchmarking as specified by the system supplier, and apply the IAEA classification criteria. Commissioning includes dosimetric and non-dosimetric items for assessing TPS performance by applying the AAPM classification criteria and the latest technical items from the IAEA. Periodic quality assurance tests include daily, weekly, monthly, yearly, and occasional items by applying the AAPM classification criteria. System management and security items include the state and network connectivity of TPS, periodic data backup, and data access security. The guidelines for TPS quality assurance proposed in this study will help to improve the safety and quality of radiotherapy by preventing incidents related to radiotherapy.

웹과 네트워크 기술을 이용한 환자 맞춤식 암치료 계획 시뮬레이션 시스템 (A Customized Cancer Radiation Treatment Planning Simulation (ccRTPs) System via Web and Network)

  • 금오연
    • 한국의학물리학회지:의학물리
    • /
    • 제17권3호
    • /
    • pp.144-152
    • /
    • 2006
  • 네트워크기술을 이용한 서버-클라이언트 원격의료기술은 특히 의료시설이 낙후된 지방도시의 의료기관에 질 높은 의료서비스를 제공할 수 있는 기술이다. 이러한 기술은 중앙 집중 방식으로 진단과 검사용으로 사용되는 대형 컴퓨터 하드웨어와 소프트웨어를 매우 효율적이고 경제적으로 관리할 수 있게 하게 때문에 궁극적으로는 의료수가를 감소시키는데도 기여할 것이다. 각 환자에 대해 환자 맞춤형 방사선 치료계획은 매우 효율적인 암 치료를 가능하게 하기 때문에 환자와 의사 모두에게 매우 유익한 방법이다. 치료계획전문가들은 환자에게 너무 적은 선량을 주면 암이 계속 재발할 확률이 높고 너무 많은 선량을 주면 환자를 다치게 할 수도 있다는 것을 잘 이해한다. 최고의 해법은 가장 정확한 선량을 주는 것인데 이것은 각 환자의 CT 자료를 기반으로 정확한 선량계획 시뮬레이션 시스템을 사용하는 것이다. 우리는 네트워크 기반과 웹 기반을 이용한 환자 맞춤형 치료계획 시뮬레이션 시스템개발을 위해 관련된 4가지 컴퓨터 프로그램을 개발하고 있다. 환자의 CT자료를 이용하여 각 환자의 표적 자료를 만드는 프로그램, 이 표적자료를 바탕으로 방사선 선량 시뮬레이션을 하는 병렬 몬테카를로 프로그램, 선량주사변수들을 최적화시키는 프로그램, 그리고 계산결과를 시각화하는 프로그램들이다. 모든 소프트웨어는 약 100-200개의 개인컴퓨터로 구성된 클러스터에서 병렬모드로 운영이 된다. 이와 같이 방대한 하드웨어와 소프트웨어의 효과적인 관리를 각 병원에 맡기는 것은 효율적이지 못하기 때문에 이를 중앙에서 관리하면서 각 병원에서는 네트워크나 웹을 통하여 마치 모든 것이 자기 병원에 있는 것과 같이 편리하게 쓸 수 있게 하는 시스템으로 의사와의 계속적인 의사소통은 클라이언트-서버 시스템의 메신저 기능을 이용한다.

  • PDF

Photon dose calculation of pencil beam kernel based treatment planning system compared to the Monte Carlo simulation

  • Cheong, Kwang-Ho;Suh, Tae-Suk;Kim, Hoi-Nam;Lee, Hyoung-Koo;Choe, Bo-Young;Yoon, Sei-Chul
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.291-293
    • /
    • 2002
  • Accurate dose calculation in radiation treatment planning is most important for successful treatment. Since human body is composed of various materials and not an ideal shape, it is not easy to calculate the accurate effective dose in the patients. Many methods have been proposed to solve the inhomogeneity and surface contour problems. Monte Carlo simulations are regarded as the most accurate method, but it is not appropriate for routine planning because it takes so much time. Pencil beam kernel based convolution/superposition methods were also proposed to correct those effects. Nowadays, many commercial treatment planning systems, including Pinnacle and Helax-TMS, have adopted this algorithm as a dose calculation engine. The purpose of this study is to verify the accuracy of the dose calculated from pencil beam kernel based treatment planning system Helax-TMS comparing to Monte Carlo simulations and measurements especially in inhomogeneous region. Home-made inhomogeneous phantom, Helax-TMS ver. 6.0 and Monte Carlo code BEAMnrc and DOSXYZnrc were used in this study. Dose calculation results from TPS and Monte Carlo simulation were verified by measurements. In homogeneous media, the accuracy was acceptable but in inhomogeneous media, the errors were more significant.

  • PDF