• Title/Summary/Keyword: radiation response

Search Result 1,316, Processing Time 0.024 seconds

SiC(3C)/Si Photodetector (SiC(3C)/Si 수광소자)

  • 박국상;남기석;김정윤
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.2
    • /
    • pp.212-216
    • /
    • 1999
  • SiC(3C) photodiodes (PDs) were fabricated on p-type Si(111) substrates using chemical vapor deposition (CVD) technique by pyrolyzing tetramethylsilane (TMS) with $H_{2}$ carrier gas. Electrical properties of SiC(3C) were investigated by Hall measurement and current-voltage (I-V) characteristics. SiC(3C) layers exhibited n-type conductivity. Ohmic contact was formed by thermal evaporation Al metal through a shadow-mask. The optical gain $(G_{op})$ of the SiC(3C)/Si PD was measured as a function of the incident wavelength. For the analysis of the photovoltaic detection of the Sic(3C) n/p PD, the spectral response (SR) has calculated by using the electrical parameters of the SiC(3C) layer and the geometric structure of the PD. The peak response calculated for properly chosen parameters was about 0.75 near 550 nm. We expect a good photoresponse in the SiC(3C) heterostructure for the wavelength range of 400~600 nm. The SiC(3C) photodiode can detect blue and near ultraviolet (UV) radiation.

  • PDF

Residential Radon and Lung Cancer Risk: An Updated Meta-analysis of Case-control Studies

  • Zhang, Zeng-Li;Sun, Jing;Dong, Jia-Yi;Tian, Hai-Lin;Xue, Lian;Qin, Li-Qiang;Tong, Jian
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.6
    • /
    • pp.2459-2465
    • /
    • 2012
  • Background: Numbers of epidemiological studies assessing residential radon exposure and risk of lung cancer have yielded inconsistent results. Methods: We therefore performed a meta-analysis of relevant published case-control studies searched in the PubMed database through July 2011 to examine the association. The combined odds ratio (OR) were calculated using fixed- or random-effects models. Subgroup and dose-response analyses were also performed. Results: We identified 22 case-control studies of residential radon and lung cancer risk involving 13,380 cases and 21,102 controls. The combined OR of lung cancer for the highest with the lowest exposure was 1.29 (95% CI 1.10-1.51). Dose-response analysis showed that every 100 Bq/$m^3$ increment in residential radon exposure was associated with a significant 7% increase in lung cancer risk. Subgroup analysis displayed a more pronounced association in the studies conducted in Europe. Studies restricted to female or non-smokers demonstrated weakened associations between exposure and lung cancer. Conclusions: This meta-analysis provides new evidence supporting the conclusion that residential exposure to radon can significantly increase the risk of lung cancer in a dose-response manner.

An Analysis of the Hydroelastic Response of Large Floating Structures in Oblique Waves (사파중에 놓인 거대 부유체의 응답에 대한 유탄성 해석)

  • In-H. Sim;Jae-D. Yoon;Hang-S. Choi
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.36 no.3
    • /
    • pp.83-92
    • /
    • 1999
  • In this paper, the fluid-structure interaction of large floating structures has been rigorously analyzed and the shear effect on the structural deformation has been investigated in oblique waves. A constant panel method(CPM) based on the Green function method is implemented for computing the hydrodynamic pressure, while a finite element method(FEM) is applied for the structural response based on the Mindlin plate theory with including shear deformation. In order to validate the method, we compared numerical results with experimental ones of Mega Float carried out by Yago & Endo in head waves. General behavior shows good agreement but the local displacement at the ends is slightly different. The numerical results show that the radiation pressure due to the fluid-structure interaction is locally larger than that of wave excitation and mooring devices greatly reduce the response. It is observed that the shear effects among the total deformation constitutes about 4% in the case of Mega Float in oblique waves.

  • PDF

Ki-67 Can Predict the Response to the Gemcitabine, Oxaliplatin And L-asparaginase Regimen (GELOX) and Prognosis in Patients with Nasal Natural Killer/T-cell Lymphoma

  • Zhang, Jing;Jiang, Wei;Wang, Wei-Da;Liu, Cheng-Cheng;Hu, Yan-Ping;Xia, Zhong-Jun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.11
    • /
    • pp.4515-4520
    • /
    • 2015
  • GELOX (gemcitabine, oxaliplatin and L-asparaginase) regimen showed an impressive result in our previous study, but the effect of this new regimen is still dissatisfying for some patients, so it is necessary to identify which patients will benefit from this regimen. A total of fifty-one cases with nasal natural killer/T-cell lymphoma receiving initial GELOX chemotherapy were enrolled in this study. The ki-67 expression detected by immunohistochemistry (IHC) in the specimens ranged from 10% to 90%, with a median value of 70%, so cases higher than the median value (${\geq}70%$) were defined as high ki-67 expression, and the others were designated as low ki-67 expression. The response rate had no statistical difference between low ki-67 expression group and high ki-67 expression group (P=0.291) though the value in the former group was relatively high. After a median follow-up of 18.03 months, the 3-year progression-free survival (PFS) for patients with low ki-67 expression was significantly higher than those with high ki-67 expression (83.8% vs. 47.9%, P=0.038). In the stage I/II subgroup, 3-year PFS and overall survival (OS) were statistically higher in the patients with low ki-67 expression than those with high ki-67 expression. Multivariate analysis revealed high ki-67 expression was an independent prognostic factor for PFS. These results suggest that low ki-67 expression can predict a good response of GELOX in these patients, and the combination of ki-67 expression and early stage is helpful to identify an excellent prognosis subgroup from patients receiving GELOX in this disease.

Ifosfamide and Doxorubicin Combination Chemotherapy for Recurrent Nasopharyngeal Carcinoma Patients

  • Dede, Didem Sener;Aksoy, Sercan;Cengiz, Mustafa;Gullu, Ibrahim;Altundag, Kadri
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.2225-2228
    • /
    • 2012
  • Background: We assessed the efficacy and toxicity of ifosfamide and doxorubicin combination chemotherapy (CT) regimen retrospectively in Turkish patients with recurrent or metastatic nasopharyngeal carcinoma (NPC) previously treated with platinum-based chemotherapy. Methods: A total of thirty patients who had received cisplatin based chemotherapy/chemoradiotherapy as a primary treatment received ifosfamide 2500 $mg/m^2$ days 1-3, mesna 2500 $mg/m^2$ days 1-3, doxorubicin 60 mg/m2 day 1 (IMA), repeated every 21 days. Eligible patients had ECOG PS< 2, measurable recurrent or metastatic disease, with adequate renal, hepatic and hematologic functions. Results: Median age was 47 (min-max; 17-60). Twenty six (86.7 %) were male. Median cycles of chemotherapy for each patient were 2 (range:1-6). Twenty patients were evaluable for toxicity and response. No patient achieved complete response, with nine partial responses for a response rate of 30.0% in evaluable patients. Stable disease, and disease progression were observed in five (16.7%) and six (20.0%) patients, respectively. Clinical benefit was 46.7%. Median time to progression was 4.0 months. Six patients had neutropenic fever after IMA regimen and there were one treatment-related death due to tumor lysis syndrome in first cycle of the CT. No cardiotoxicity was observed after CT and treatments were generally well tolerated. Conclusion: Ifosfomide and doxorubicin combination is an effective regimen for patients with recurrent and metastatic NPC. For NPC patients demonstrating failure of cisplatin based regimens, this CT combination may be considered as salvage therapy.

Postoperative Cure for Metastatic Gastrointestinal Stromal Tumor (전이성 위장관 기질종양의 수술 후 완치)

  • Park, Eun Hyea;Kim, Jin Il;Cheung, Dae Yong;Park, Soo-Heon
    • The Korean journal of helicobacter and upper gastrointestinal research
    • /
    • v.18 no.4
    • /
    • pp.264-270
    • /
    • 2018
  • Gastrointestinal stromal tumor (GIST) is a mesenchymal tumor derived from Cajal cells originating from the myotonic plexus. The expression of tyrosine kinase (KIT) membrane receptors that are active on KIT is inhibited by the KIT inhibitor imatinib mesylate. GISTs are resistant to conventional chemotherapy, and radiation therapy is not significantly beneficial for GISTs. With the development of imatinib mesylate, approximately 81.6% of patients with advanced and metastatic GIST exhibit an effect above the stabilization response, thereby increasing the survival time. However, imatinib mesylate alone is unlikely to cure metastatic GISTs. Even with a partial or stable response, imatinib mesylate may be used for a longer time period. However, resection of grossly visible lesions should be considered for patients with a stable response during surgical treatment. In this study, we present a case of GIST with liver metastasis after imatinib mesylate treatment, which was followed up without recurrence after partial resection.

Numerical and Experimental Study on Linear Behavior of Salter's Duck Wave Energy Converter (비대칭 형상 파력발전 로터의 선형 거동에 대한 수치적·실험적 연구)

  • Kim, Dongeun;Poguluri, Sunny Kumar;Ko, Haeng Sik;Lee, Hyebin;Bae, Yoon Hyeok
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.116-122
    • /
    • 2019
  • Among the various wave power systems, Salter's duck (rotor) is one of the most effective wave absorbers for extracting wave energy. The rotor shape is designed such that the front part faces the direction of the incident wave, which forces it to bob up and down due to wave-induced water particle motion, whereas the rear part, which is mostly circular in shape, reflects no waves. The asymmetric geometric shape of the duck makes it absorb energy efficiently. In the present study, the rotor was investigated using WAMIT (a program based on the linear potential flow theory in three-dimensional diffraction/radiation analyses) in the frequency domain and verified using OrcaFlex (design and analysis program of marine system) in the time domain. Then, an experimental investigation was conducted to assess the performance of the rotor motion based on the model scale in a two-dimensional (2D) wave tank. Initially, a free decay test (FDT) was carried out to obtain the viscous damping coefficient. The pitch response was extracted from the experimental time series in a periodic regular wave for two different wave heights (1 cm and 3 cm). In addition, the viscous damping coefficient was calculated from the FDT result and fluid forces, obtained from WAMIT, are incorporated into the final response of the rotor. Finally, a comparative study based on experimental and numerical results (WAMIT & OrcaFlex) was performed to confirm the performance reliability of the designed rotor.

A Survey of Medical Environments in Regional Public Hospitals Respond to Disasters (지역거점공공병원의 재난 대비 안전한 의료환경 실태조사 연구)

  • Lee, Hyunjin;Song, Sanghoon;Kim, Taeyun;Kim, Youngaee
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.30 no.2
    • /
    • pp.35-46
    • /
    • 2024
  • Purpose: It is the responsibility of public healthcare to respond quickly to infectious disease outbreaks and disasters such as MERS, COVID-19, the Syrian earthquake, and the Miryang Sejong Hospital fire accident. It is very important to secure safe medical facilities and protect lives through emergency medical support and disaster response systems. The purpose of this study is to investigate the safety status of regional medical facilities that play a central role in the event of a disaster. Methods: The target was 41 local public hospitals, including 35 regional medical centers and 6 Red Cross hospitals nationwide. We delivered a questionnaire to 41 medical facilities and collected data from 32 regional public hospitals that received responses. Results: In order to respond to safety accidents, a survey was conducted on infections, falls, patient identification, and incorrect connections for medical accidents, and for in-hospital accidents, a survey was conducted on entrapment, collision, water leaks, falling objects, and crime prevention. For natural disasters, we investigated the response environment for typhoons, floods, and snow damage, and for social disasters, we investigated the response environment for fire, power outages, and radiation damage. Implications: We hope that it will be used as basic data for developing standards and creating hospital facilities and environments that are safe for everyone to respond to various disasters and prevent patient safety accidents in the future.

Photon dose response functions for accurate skeletal dosimetry for Korean and Asian populations

  • Bangho Shin;Chansoo Choi;Rui Qiu;Suhyeon Kim;Hyeonil Kim;Sungho Moon;Gahee Son;Jaehyo Kim;Haegin Han;Yeon Soo Yeom;Chan Hyeong Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2195-2207
    • /
    • 2024
  • To enhance skeletal dosimetry in conjunction with the adult mesh-type reference Korean phantoms (MRKPs), Korean/Asian photon fluence-to-skeletal dose response functions (DRFs) were established utilizing an updated version of micro-CT-based detailed bone models from Tsinghua University. These bone models were incorporated into the MRKPs using the parallel geometry feature of Geant4. We calculated bone-site-specific electron absorbed fractions and used them to generate DRFs, following a similar methodology employed for ICRP-116 DRFs that have been used with the ICRP reference phantoms for skeletal dosimetry. To assess dosimetric implications of the Korean/Asian DRFs, we calculated RBM and BE doses for the MRKPs exposed to photon beams in the antero-posterior direction using the Korean/Asian and ICRP-116 DRFs. For energies ≥200 keV, the Korean/Asian DRFs-based skeletal doses exhibited excellent agreement with the ICRP-116 DRFs-based skeletal doses, attributed to the existence of charged particle equilibrium across the bone site. Conversely, significant differences of up to ~2.3 times were observed at lower energies, due to differences in the skeletal tissue distributions of bone models used to derive the Korean/Asian and ICRP-116 DRFs. The DRFs established in this study are expected to yield more accurate skeletal doses for Korean and Asian populations compared to the ICRP-116 DRFs.

Deconvolution of Detector Size Effect Using Monte Carlo Simulation (몬데카를로 시뮬레이션을 이용한 검출기의 크기효과 제거)

  • Park, Kwangyl;Yi, Byong-Yong;Young W. Vahc
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.100-104
    • /
    • 2004
  • The detector size effect due to the spatial response of detectors is a critical source of inaccuracy in clinical dosimetry that has been the subject of numerous studies. Conventionally, the detector response kernel contains all the information about the influence that the detector size has on the measured beam profile. Various analytical models for this kernel have been proposed and studied in theoretical and experimental works. Herein, a method to simply determine the detector response kernel using the Monte Carlo simulation and convolution theory has been proposed. Based on this numerical method, the detector response kernel for a Farmer type ion chamber embedded in a water phantom has been obtained. The obtained kernel shows characteristics of both the pre-existing parabolic model proposed by Sibata et al. and the Gaussian model used by Garcia-Vicente et al. From this kernel and deconvolution technique, the detector size effect can be removed from measurements for 6MV, 10${\times}$10 $\textrm{cm}^2$ and 0.5${\times}$10 $\textrm{cm}^2$photon beams. The deconvolved beam profiles are in good agreements with the measurements performed by the film and pin-point ion chamber, with the exception of in the tail legion.

  • PDF