• Title/Summary/Keyword: radiation power

Search Result 1,954, Processing Time 0.027 seconds

Comparison of Horizontal and Vertical Noise Power Spectrum in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료 시 전자포털 영상장치를 이용한 잡음전력스펙트럼 수평 및 수직 측정비교)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Kwon, Kyung-Tae;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.171-176
    • /
    • 2016
  • The quality assurance (QA) is very important for diagnostic field and radiation therapy field to evaluate the characteristic of devices. The purpose of this study was to compare different NPS methodologies results which are measuring NPS with regard to horizontal and vertical directions by using megavoltage X-ray energies. The NPS evaluation methods were applied to the International Electro-technical Commission standard (IEC 62220-1). The electronic portal imaging devices (EPID) devices such as Siemens BEAMVIEW$^{PLUS}$, Elekta iViewGT and Varian Clinac$^R$ iX aS1000 were used. NPS data were expressed by corresponding each frequency about average of noise value corresponding the each frequency, and NPS were evaluated quantitatively by totaling up the noise values of average frequency which are on horizontal and vertical directions. In NPS results for Elekta iViewGT, NPS of horizontal and vertical by using 4 methods were indicated the difference of 3~5% between horizontal and vertical direction. In the results of Siemens BEAMVIEW$^{PLUS}$ and Varian Clinac$^R$ iX aS1000, the NPS of horizontal and vertical direction were indicated the difference of 15% when averaging the whole values. This study were evaluated the NPS of each devices by totaling up the noise values of average frequency which are on horizontal and vertical directions suggesting the quantitative evaluation method using the data.

Structure and Variation of Tidal Flat Temperature in Gomso Bay, West Coast of Korea (서해안 곰소만 갯벌 온도의 구조 및 변화)

  • Lee, Sang-Ho;Cho, Yang-Ki;You, Kwang-Woo;Kim, Young-Gon;Choi, Hyun-Yong
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.10 no.1
    • /
    • pp.100-112
    • /
    • 2005
  • Soil temperature was measured from the surface to 40 cm depth at three stations with different heights in tidal flat of Gomso Bay, west coast of Korea, for one month in every season 2004 to examine the thermal structure and the variation. Mean temperature in surface layer was higher in summer and lower in winter than in lower layer, reflecting the seasonal variation of vertically propagating structure of temperature by heating and cooling from the tidal flat surface. Standard deviation of temperature decreased from the surface to lower layer. Periodic variations of solar radiation energy and tide mainly caused short term variation of soil temperature, which was also intermittently influenced by precipitation and wind. Time series analysis showed the power spectral energy peaks at the periods of 24, 12 and 8 hours, and the strongest peak appeared at 24 hour period. These peaks can be interpreted as temperature waves forced by variations of solar radiation, diurnal tide and interaction of both variations, respectively. EOF analysis showed that the first and the second modes resolved 96% of variation of vertical temperature structure. The first mode was interpreted as the heating antl cooling from tidal flat surface and the second mode as the effect of phase lag produced by temperature wave propagation in the soil. The phase of heat transfer by 24 hour period wave, analyzed by cross spectrum, showed that mean phase difference of the temperature wave increased almost linearly with the soil depth. The time lags by the phase difference from surface to 10, 20 and 40cm were 3.2,6.5 and 9.8 hours, respectively. Vertical thermal diffusivity of temperature wave of 24 hour period was estimated using one dimensional thermal diffusion model. Average diffusivity over the soil depths and seasons resulted in $0.70{\times}10^{-6}m^2/s$ at the middle station and $0.57{\times}10^{-6}m^2/s$ at the lowest station. The depth-averaged diffusivity was large in spring and small in summer and the seasonal mean diffusivity vertically increased from 2 cm to 10 cm and decreased from 10 cm to 40 cm. Thermal propagation speeds were estimated by $8.75{\times}10^{-4}cm/s,\;3.8{\times}10{-4}cm/s,\;and\;1.7{\times}10^{-4}cm/s$ from 2 cm to 10 cm, 20 cm and 40 cm, respectively, indicating the speed reduction with depth increasing from the surface.

The Study of Standardization of Temperature Distribution of Interstitial Hyperthermia -In Phantoms and Living cat's brain tissue (Normal Tissue)- (915 MHz 극초단파 자입온열시 온도분포 적정화에 관한 연구 -조직등가물 및 가묘대뇌를 대상으로-)

  • Kyoung Hwan Koh;Cho Chul Koo;Park Young Hwan;Yoo Seong Yul;Kim Jong Hyun;Lee Seung Hoon
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.7-15
    • /
    • 1990
  • The ultimate objective of our experiment is to obtain the precise distribution of temperature in malignant tumors occurring in cerebral parenchyme of human beings when we will carry out interstitial hyperthermia in the near future. To achieve this purpose, first of all, it is necessary to make an attempt at performing interstitial hyperthermia in vivo under the similar condition of human beings. Therefore, we chose cats as materials much alike tissue characteristics of human beings. Moreover, it is also necessary to get the basic data from dynamic phantom in order to standardize and compare results obtained from interstitial hyperthermia carried out in cats. By having performed these experiments we got the following results. 1) On doing interstitial hyperthermia with 915 MHz microwave, the possible treated volume was 2 cm by 2 cm by 6 cm according to $50\%$ specific absorption rate (SAR). 2) The distribution of temperature within non-circulated static phantom was much the same as power density in air, but we observed that the temperature, within $5\~10$ minutes, rose to more higher than $55^{\circ}C$ not measured with Ga-As fiberoptic thermistor which was not impeded by microwave after performing interstitial hyperthermia. 3) Within dynamic phantom in which normal saline was circulating, temperature reached steady state which was maintained for more than 45 minutes through transit period in 5 minutes after starting interstitial hyperthermia. 4) When we interrupted circulation in the dynamic phantom, we observed that temperature rose to the same level as in the static phantom. 5) We could carry out interstitial hyperthermia safely when we used the generating power below 5 watts. Abrupt interruption of circulation caused a rapid increase in temperature. Times taking to rise to maximum $55^{\circ}C$ were 15.2 minutes (SE 0.4),9.7 minutes (SE 0.3), and 6.3 min-utes (SE 0.4) respectively with generating powers of 5,10, and 15 watts.

  • PDF

Hay Preparation Technology for Sorghum×Sudangrass Hybrid Using a Stationary Far-Infrared Dryer (정치식 원적외선 건조기를 이용한 수수×수단그라스 교잡종의 건초 조제 기술 연구)

  • Jong Geun Kim;Hyun Rae Kim;Won Jin Lee;Young Sang Yu;Yan Fen Li;Li Li Wang
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.43 no.1
    • /
    • pp.22-27
    • /
    • 2023
  • This experiment was conducted to confirm the possibility of preparing Sorghum×sudangrass hybrid artificial hay using far-infrared rays in Korea. The machine used in this experiment is a drying device based on far-infrared rays, and is designed to control temperature, air flow rate, far-infrared radiation amount, and air flow speed. The Sorghum×sudangrass hybrids harvested in late September were wilted in the field for one day, and a drying test was performed on them. Conditions for drying were performed by selecting a total of 7 conditions, and each condition induced a change in radiation amount in a single condition (42%) and two steps (4 treatments) and three steps (2 treatments). The speed of the air flow in the device was fixed at 60 m/s, and the run time was changed to 30, 60, and 90 minutes. The average dry matter (DM) content was 82.84%. The DM content was 59.94 and 76.91%, respectively, in drying conditions 1 and 3, which were not suitable for hay. In terms of drying rate, it was significantly higher than 80% in the 5, 6 and 7 treatment, and power consumption was slightly high with an average of 5.7 kw/h. As for the feed value according to each drying condition, the crude protein (CP) content increased as the drying time increased, and there was no significant difference between treatments in ADF, NDF, IVDMD and TDN content. In terms of RFV, treatment 1, which is a single condition, was significantly lower than the complex condition. Through the above results, it was determined that the drying conditions 4 and 5 were the most advantageous when considering the drying speed, power consumption, and quality.

A Statistical Analysis of External Force on Electric Pole due to Meteorological Conditions (기상현상에 의한 전주 외력의 통계적 분석)

  • Park, Chul Young;Shin, Chang Sun;Cho, Yong Yun;Kim, Young Hyun;Park, Jang Woo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.11
    • /
    • pp.437-444
    • /
    • 2017
  • Electric Pole is a supporting beam used for power transmission/distribution which is sensitive to external force change of environmental factors. Therefore, power facilities have many difficulties in terms of maintenance/conservation from external environmental changes and natural disasters that cause a great economic impact. The aerial wire cause elasticity due to the influence of temperature, or factors such as wind speed and wind direction, that weakens the electric pole. The situation may lead to many safety risk in day-to-day life. But, the safety assessment of the pole is carried out at the design stage, and aftermath is not considered. For the safety and maintenance purposes, it is very important to analyze the influence of weather factors on external forces periodically. In this paper, we analyze the acceleration data of the sensor nodes installed in electric pole for maintenance/safety purpose and use Kalman filter as noise compensation method. Fast Fourier Transform (FFT) is performed to analyze the influence of each meteorological factor, along with the meteorological factors on frequency components. The result of the analysis shows that the temperature, humidity, solar radiation, hour of daylight, air pressure, wind direction and wind speed were influential factors. In this paper, the influences of meteorological factors on frequency components are different, and it is thought that it can be an important factor in achieving the purpose of safety and maintenance.

An Electrical Properties Analysis of CMOS IC by Narrow-Band High-Power Electromagnetic Wave (협대역 고출력 전자기파에 의한 CMOS IC의 전기적 특성 분석)

  • Park, Jin-Wook;Huh, Chang-Su;Seo, Chang-Su;Lee, Sung-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.9
    • /
    • pp.535-540
    • /
    • 2017
  • The changes in the electrical characteristics of CMOS ICs due to coupling with a narrow-band electromagnetic wave were analyzed in this study. A magnetron (3 kW, 2.45 GHz) was used as the narrow-band electromagnetic source. The DUT was a CMOS logic IC and the gate output was in the ON state. The malfunction of the ICs was confirmed by monitoring the variation of the gate output voltage. It was observed that malfunction (self-reset) and destruction of the ICs occurred as the electric field increased. To confirm the variation of electrical characteristics of the ICs due to the narrow-band electromagnetic wave, the pin-to-pin resistances (Vcc-GND, Vcc-Input1, Input1-GND) and input capacitance of the ICs were measured. The pin-to-pin resistances and input capacitance of the ICs before exposure to the narrow-band electromagnetic waves were $8.57M{\Omega}$ (Vcc-GND), $14.14M{\Omega}$ (Vcc-Input1), $18.24M{\Omega}$ (Input1-GND), and 5 pF (input capacitance). The ICs exposed to narrow-band electromagnetic waves showed mostly similar values, but some error values were observed, such as $2.5{\Omega}$, $50M{\Omega}$, or 71 pF. This is attributed to the breakdown of the pn junction when latch-up in CMOS occurred. In order to confirm surface damage of the ICs, the epoxy molding compound was removed and then studied with an optical microscope. In general, there was severe deterioration in the PCB trace. It is considered that the current density of the trace increased due to the electromagnetic wave, resulting in the deterioration of the trace. The results of this study can be applied as basic data for the analysis of the effect of narrow-band high-power electromagnetic waves on ICs.

Construction and Performance Evaluation of Digital Radiographic System (이동형 디지털 X선 촬영장치의 구축 및 성능평가)

  • Cho, Hyo-Min;Nam, So-Ra;Lee, Chang-Lae;Jung, Ji-Young;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.144-148
    • /
    • 2007
  • Current digital radiography systems are rapidly glowing in clinical applications. The purpose of this study was to evaluate the characteristics of a mobile digital radiographic system. The performance of the mobile DR system was evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Measurements were made on a LISTEM Mobix-1000 generator and a Teleoptic PRA Alpha-R4000 detector. Imaging characteristics were measured for these two systems using the IEC-61267 defined RQA5 (kVp: 74, additional filtration: 21 mmAl) radiographic condition. The MTF at 10% was measured as 2.4 cycles/mm and the DQE(0) values for radiation exposure 0.19, 0.5, and 1.3 mR were measured as 54%, 55%, and 76%, respectively. The NPS curves gradually decreased at high spatial frequencies. This high DQE at low frequencies, may be useful for low frequency information. The results suggested that mobile DR system could be integrated with emergency ambulance system in teleradiologic imaging applications.

  • PDF

A Study on the Method for the Removal of Radioactive Corrosion Produce Using Permanent and Electric Magnets

  • Kong Tae-Young;Song Min-Chul;Lee Kun-Jai
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.2
    • /
    • pp.113-123
    • /
    • 2005
  • The removal of radioactive corrosion products from the reactor coolant through a magnetic filter system is one of the many approaches being investigated as a means to reduce radiation sources and exposures to the operational and maintenance personnel in a nuclear power plant. Many research activities in water chemistry, therefore, have been performed to provide a filtration system with high reliability and feasibility and are still in process. In this study, it was devised the magnetic filter system with permanent and electric magnets to remove the corrosion products in the coolant stream taking an advantage of the magnetic properties of corrosion particles. Permanent magnets were used for separation of corrosion products and electric magnets were utilized for flocculation of colloidal particles to increase in their size. Experiments using only permanent magnets, in the previous study, displayed the satisfactory outcome of filtering corrosion products and indicated that the removal efficiency was more than 90 $\%$ for above 5 $\mu$m particles. Experiments using electric magnets also showed the good performance of flocculation without chemical agents and exhibited that most corrosion particles were flocculated into larger aggregates about 5 $\mu$m and over in diameter. It is, thus, expected that the magnetic filter system with the arrangement of permanent and electric magnets will be an effective way for the removal of radioactive corrosion products with considerably high removal efficiency.

  • PDF

Preliminary Assessment of Radiological Impact on the Domestic Railroad Transport of High Level Radioactive Waste (고준위 방사성폐기물의 국내철도운반에 관한 방사선영향 예비평가)

  • Seo, Myunghwan;Dho, Ho-Seog;Hong, Sung-Wook;Park, Jin Beak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.4
    • /
    • pp.381-390
    • /
    • 2017
  • In Korea, commercial nuclear power plants and research reactors have on-site storage systems for the spent nuclear fuel, but it is difficult to expand the facilities used for the storage systems. If decommissioning of nuclear power plants starts, an amount of high level radioactive waste will be generated. In this study, a radiological impact assessment of the railroad transport of high level radioactive waste was carried out considering radiation workers and the public, using the developed transport container as the transport package. The dose rates for workers and the public during the transport period were estimated, considering anticipated transport scenarios, and the results compared with the regulatory limit. A sensitivity analysis was also carried out by considering the different release ratios of the radioactive materials in the high level radioactive waste, and different distances between the transport container and workers during loading and unloading phases and while attaching another freight car. For all the anticipated transport scenarios, the radiological impacts for workers and the public met the regulatory limits.

A 3-D Measuring System of Thermoluminescence Spectra and Thermoluminescence of CaSO4 : Dy, P (열자극발광 스펙트럼의 3차원 측정 장치와 CaSO4 : Dy, P의 열자극발광)

  • Lee, Jung-Il;Moon, Jung-Hak;Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.71-75
    • /
    • 2001
  • In this paper, a three-dimensional measuring system of thermoluminescence(TL) spectra based on temperature, wavelength and luminescence intensity was introduced. The system was composed of a spectrometer, temperature control unit for thermal stimulation, photon detector and personal computer for control the entire system. Temperature control was achieved by using feedback to ensure a linear-rise in the sample temperature. Digital multimeter(KEITHLEY 195A) measures the electromotive force of Copper-Constantan thermocouple and then transmits the data to the computer through GPIB card. The computer converts this signal to temperature using electromotive force-temperature table in program, and then control the power supply through the D/A converter. The spectrometer(SPEX 1681) is controlled by CD-2A, which is controlled by the computer through RS-232 communication port. For measuring the luminescence intensity during the heating run, the electrometer(KEITHLEY 617) measures the anode current of photomultiplier tube(HAMAMATSU R928) and transmits the data to computer through the A/D converter. And, we measured and analyzed thermoluminescence of $CaSO_4$ : Dy, P using the system. The measuring range of thermoluminescence spectra was 300K-575K and 300~800 nm, $CaSO_4$ : Dy. P was fabricated by the Yamashita's method in Korea Atomic Energy Research Institute(KAERI) for radiation dosimeter. Thermoluminesce spectra of the $CaSO_4$ : Dy, P consist of two main peak at temperature of $205^{\circ}C$, wavelength 476 nm and 572 nm and with minor ones at 658 nm and 749 nm.

  • PDF