• Title/Summary/Keyword: radiation power

Search Result 1,954, Processing Time 0.025 seconds

A Solar Stationary Type IV Radio Burst and Its Radiation Mechanism

  • Liu, Hongyu;Chen, Yao;Cho, Kyungsuk;Feng, Shiwei;Vasanth, Veluchamy;Koval, Artem;Du, Guohui;Wu, Zhao;Li, Chuanyang
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.52.2-53
    • /
    • 2018
  • A stationary Type IV (IVs) radio burst was observed on September 24, 2011. Observations from the Nançay RadioHeliograph (NRH) show that the brightness temperature (TB ) of this burst is extremely high, over 10^11K at 150 MHz and over 10^8K in general. The degree of circular polarization (q ) is between -60%~-100%, which means that it is highly left-handed circularly polarized. The flux-frequency spectrum follows a power-law distribution, and the spectral index is considered to be roughly -3~-4 throughout the IVs. Radio sources of this event are located in the wake of the coronal mass ejection and are spatially dispersed. They line up to present a formation in which lower-frequency sources are higher. Based on these observations, it is suggested that the IVs was generated through electron cyclotron maser emission.

  • PDF

Revealing the Powering Mechanism of Lyman Alpha Blob via Polarization

  • Kim, Eunchong;Yang, Yujin;Zabludoff, Ann;Smith, Paul;Jannuzi, Buell;Lee, Myung Gyoon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.35.4-36
    • /
    • 2018
  • $Ly{\alpha}$ blobs are mysterious, giant (~100 kpc), glowing gas clouds in the distant universe. They occupy the dark matter halos that will evolve into the richest groups and clusters today. The blob's gas may be the proto-intracluster medium and their embedded galaxies are considered as the progenitors of massive cluster galaxies. Yet we do not know why $Ly{\alpha}$ blobs glow. There are evidences of kinematic measurements to exclude shocks and winds from AGN or starbursts as a power source, suggesting that photoionizing radiation or scattering of $Ly{\alpha}$ photons might be responsible. Polarization mapping can discriminate between these photo-ionization and scattering. Previous results of imaging polarimetry for $Ly{\alpha}$ nebulae are roughly consistent with scattering models. However the polarization morphologies in those of previous results are all different, motivating our polarimetric survey of $Ly{\alpha}$ nebulae for the statisticallymeaningful sample. As initial results of our survey, we present the total polarization map of the LABd05 which has the spatial offset between the peak of $Ly{\alpha}$ surface brightness and an obscured AGN. We detect the significant polarization in this target with the radially increasing polarization gradient, suggesting that scattering plays major role within this nebula. The polarization pattern is more aligned with the $Ly{\alpha}$ peak rather than the AGN (the potential energy source), indicating that the $Ly{\alpha}$ photons are originated from the region near the peak of $Ly{\alpha}$ intensity.

  • PDF

Monitoring of Climate Change of Northeast Asia and Background Atmosphere in Korea

  • Oh, Sung-Nam;Chung, Hyo-Sang;Choi, Jae-Cheon;Bang, So-Young;Hyun, Myung-Suk
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.232-235
    • /
    • 2003
  • In general, the parameters of climate change include aerosol chemical compounds, aerosol optical depth, greenhouse gases(carbon dioxide, CFCs, methane, nitrous oxide, tropospheric ozone), ozone distribution, precipitation acidity and chemical compounds, persistent organic pollutants and heavy metals, radioactivity, solar radiation including ultra-violet and standard meteorological parameters. Over the last ten years, the monitoring activities of Korea regarding to the climate change have been progressed within the WMO GAW and ACE-Asia IOP programs centered at the observation sites of Anmyeon and Jeju Gosan islands respectively. The Greenhouse gases were pointed out that standard air quality monitoring techniques are required to enhance data comparability and that data presentation formats need to be harmonized and easily understood. Especially, the impact of atmospheric aerosols on climate depends on their optical properties, which, in turn, are a function of aerosol size distribution and the spectral reflective indices. Aerosol optical depth and single scattering albedo in the visible are used as the two basic parameters in the atmospheric temperature variation studies. The former parameter is an indicator of the attenuation power of aerosols, while the latter represents the relative strength of scattering and absorption by aerosols. For aerosols with weak absorption, surface temperature decreases as the optical depth increases because of the domination of backscattering. For aerosols with strong absorption, however, warming could occur as the optical depth increases. The objective of the study is to characterize the means, variability, and trends of Greenhouse gases and aerosol properties on a regional basis using data from its baseline observatories in Korea peninsula. A further goal is to understand the factors that control radiative forcing of the greenhouse and aerosol.

  • PDF

Electromagnetic Interference Suppression Method of Motor Assembly for Aircraft Application (항공용 모터 조립체의 전자기 간섭 감쇠 방안)

  • Kim, Jee-Heung;Ryu, Hong-Kyun;Park, Beom-Jun;Park, Young-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.351-358
    • /
    • 2018
  • In this study, we propose a method of suppressing the leakage noise signal of motor assembly through the test. The motor assembly is mounted on outside of the aircraft to rotate an antenna and must satisfy RE102 requirement on MIL-STD-461F in terms of electromagnetic interference. It is confirmed by RE102 test result hat the leakage noise signal of the equipment occurs due to external influx through the power and control cable and rotation of the motor. And it is ascertained that the part where internal/external physical shielding is difficult to rotate is the leakage path. To reduce the leakage noise signal, the electrical ground reinforcement and the electric shielding structure considering the operation of the equipment is applied and it is verified that the requirement is satisfied. Finally, we verified that required specification are met by applying circular corrugated choke with interlocking shapes and conductive grease to the noise leakage path.

Design and Development of Signal Transmitting POD for Aircraft Application (항공기용 신호 송출 POD의 설계 및 개발)

  • Kim, Jee-heung;Kwak, Young-kil;Kim, Kichul;Park, Joo-rae
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • In this research, we develop an airborne equipment radiating S/C-band signal to a target located at a long distance. RF interface of the equipment comprises band-specific transmitters and an broadband antenna to satisfy EIRP(effective isotropic radiated power) requirements. The equipment is in a shape of a POD like an aircraft fuel tank. The measured weight of the equipment is 119.8 kg, the CG(center of gravity) is 1391.35 mm and the MOI(moment of inertia) are 46.07 ± 0.05(Iyy) kg·㎡, 45.36 ± 0.09(Izz) kg·㎡. All results are found to meet the requirements for aircraft installation. To verify flight safety, EMI(electromagnetic interference) tests (RE102, CE102), environmental tests (high/low temperature operation, altitude), intra-system EMC(electromagnetic compatibility) and HERP(hazards electromagnetic radiation personnel) tests have been conducted and all the test results met the requirements. It is confirmed that the equipment could be mounted on the aircraft by meeting all electrical and mechanical requirements.

3D RANS Simulation and the Prediction by CRN Regarding NOx in a Lean Premixed Combustion in a Gas Turbine Combustor (희박 예혼합 가스터빈 연소기 3 차원 전산 해석 및 화학반응기 네트워크에 의한 NOx 예측)

  • Yi, Jae-Bok;Jeong, Dae-Ro;Huh, Kang-Yul;Jin, Jae-Min;Park, Jung-Kyu;Lee, Min-Chul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1257-1264
    • /
    • 2011
  • This paper presents 3D simulation by STAR-CCM+ for lean premixed combustion in a stationary gas turbine combustor with separate pilot and main nozzles. The constant for the source term in the flame area density transport equation was modified to account for a low global equivalence ratio and validated against measurement data. A Partially-premixed Coherent Flame Model(PCFM) involves propagation of a laminar premixed flame with the predicted flame surface density and equilibrium assumption in the burned gas with spatial inhomogeneity. The conditions for cooling by radiation and convection are considered for accurate determination of the heat flux on the wall. A parametric study is of the pilot-fuel-to-total-fuel-ratio is carried out. A chemical reactor network (CRN) was constructed on the basis of the 3D simulation results and compared against measurements of NOx.

Analytical Investigation of In-direct Heater to Simulate Space Thermal Environment for Thermal Vacuum Test (열진공 시험용 비접촉식 우주 열환경 모사 장치의 해석적 검토)

  • Baek, Cheul-Woo;Shin, So-Min;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.2
    • /
    • pp.178-183
    • /
    • 2012
  • To simulate space thermal environment in thermal vacuum test, direct or in-direct heater has been applied on the radiator. Both of them, direct heater attached on the radiator and indirect heater with a distance from the radiator, simulate the heat fluxes from the Sun radiation, the Earth IR and Albedo. They also supply the heat fluxes to the radiator of spacecraft to achieve the target temperature according to thermal test conditions. In general, indirect heater is used when the heater is not allowed to attach on the radiator directly due to constraints of coating property or contamination. For in-direct heater design, it is needed to estimate the heat power to make the extreme test conditions and minimize the interference with heat exchange of radiator and shroud. In this study, optimized thermal design of in-direct heater is proposed and investigated by commercial S/W SINDA. The effective values of design factors are also derived.

The Noise Evaluation for Ragius 150 CR System (Regius 150 Computed Radiography 시스템의 Noise 평가에 관한 연구)

  • Kim, Jung-Min;Min, Jung-Whan;Jeong, Hea-Won;Im, Eun-Kyung;Yang, Han-Joon
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.237-240
    • /
    • 2006
  • The Noise of CR Systems is made up of X-ray quantum mottle and additional Imaging plate's structure noise, photon noise of lumine cence, noise of electrometer, quantization noise etc. In this Regius 150 system, SNR was increased from 8.2 to 30 with linearily according to radiation dose from 0.1 mR to 100 mR. It means that the Regius 150 system has enough trustability because of SNR is over 5 by Rose Model. NPS was calculated two dementional Fourier Transform with shake of pixel value in the white Image. In the spatial frequence range of $0.5\;lp/mm{\sim}2.5\;lp/mm$, the NPS was distributed $10^{-4}{\sim}10^{-5}$ at 1 mR X-ray dose. That is similar result compare other systems to that of Kodak CR system reported by Carlu, HR-CR system reported by Dobbins.

  • PDF

Predicting the Greenhouse Air Humidity Using Artificial Neural Network Model Based on Principal Components Analysis (PCA에 기반을 둔 인공신경회로망을 이용한 온실의 습도 예측)

  • Owolabi, Abdulhameed B.;Lee, Jong W;Jayasekara, Shanika N.;Lee, Hyun W.
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.5
    • /
    • pp.93-99
    • /
    • 2017
  • A model was developed using Artificial Neural Networks (ANNs) based on Principal Component Analysis (PCA), to accurately predict the air humidity inside an experimental greenhouse located in Daegu (latitude $35.53^{\circ}N$, longitude $128.36^{\circ}E$, and altitude 48 m), South Korea. The weather parameters, air temperature, relative humidity, solar radiation, and carbon dioxide inside and outside the greenhouse were monitored and measured by mounted sensors. Through the PCA of the data samples, three main components were used as the input data, and the measured inside humidity was used as the output data for the ALYUDA forecaster software of the ANN model. The Nash-Sutcliff Model Efficiency Coefficient (NSE) was used to analyze the difference between the experimental and the simulated results, in order to determine the predictive power of the ANN software. The results obtained revealed the variables that affect the inside air humidity through a sensitivity analysis graph. The measured humidity agreed well with the predicted humidity, which signifies that the model has a very high accuracy and can be used for predictions based on the computed $R^2$ and NSE values for the training and validation samples.

The Effect of Soil Warming on the Greenhouse Heating Load (지중가온이 온실의 난방부하에 미치는 영향)

  • Nam, Sang-Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.5
    • /
    • pp.51-60
    • /
    • 2006
  • In order to examine the heat transfer characteristic of a soil warming system and effects of soil warming on the greenhouse heating load, control experiments were performed in two greenhouses covered with double polyethylene film. One treated the soil warming with an electric heat wire and the other treated a control. Inside and outside air temperature, soil temperature and heat flux, and heating energy consumption were measured under the set point of heating temperature of $5,\;10,\;15,\;and\;20^{\circ}C$, respectively. Soil temperatures in a soil warming treatment were observed $4.1\;to\;4.9^{\circ}C$ higher than a control. Heating energy consumptions decreased by 14.6 to 30.8% in a soil warming treatment. As the set point of heating temperature became lower, the rate of decrease in the heating energy consumptions increased. The percentage of soil heat flux in total heating load was -49.4 to 24.4% and as the set point of heating temperature became higher, the percentage increased. When the set point of heating temperature was low in a soil warming treatment, the soil heat flux load was minus value and it had an effect on reducing the heating load. Soil heat flux loads showed in proportion to the air temperature difference between the inside and outside of greenhouse but they showed big difference according to the soil warming treatment. So new model for estimation of the soil heat flux load should be introduced. Convective heat transfer coefficients were in proportion to the 1/3 power of temperature difference between the soil surface and the inside air. They were $3.41\;to\;12.42\;W/m^{2}^{\circ}C$ in their temperature difference of $0\;to\;10^{\circ}C$. Radiative heat loss from soil surface in greenhouse was about 66 to 130% of total heating load. To cut the radiation loss by the use of thermal curtains must be able to contribute for the energy saving in greenhouse.