• 제목/요약/키워드: radiation efficiency

검색결과 1,248건 처리시간 0.02초

공동주택의 태양열 집열기 효율에 대한 실험적 연구 (An Experimental Study on the Solar Collector Efficiency for Apartment Building)

  • 최병도;김미연
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.130.2-130.2
    • /
    • 2011
  • The application of solar energy in residential building is general and natural in today. And application methods of solar thermal energy is divided in two kind of form, single evacuated tube and flat-plate form. Then in this study, the efficiency of single evacuated tube and flat-plate system is compared by total and effective area considering the time receiving the solar radiation between 24 hours and the specific time(10:00~15:00). As a result of the experiment, single evacuated tube and flat-plate collector's efficiency is varied by the quantity of solar radiation. And especially, the flat-plate system is more affected by outdoor temperature. Therefore the application of solar thermal system should be considered the solar radiation and outdoor temperature.

  • PDF

감마선을 이용한 Escherichia coli K12의 살균에서 persulfate의 효과 (Effect of Persulfate on Disinfection of Escherichia coli K12 by Gamma Radiation)

  • 이오미;김태훈;유승호;정인하;이면주
    • 방사선산업학회지
    • /
    • 제5권1호
    • /
    • pp.63-67
    • /
    • 2011
  • A comparative experiment was conducted to compare the effects of persulfate with gamma radiation on the disinfection efficiencies against Escherichia coli K12. The microorganism used for the disinfection experiments were prepared by transferring a bacterial stock culture into a 50 ml nutrient broth an incubating for 24 hrs at $37^{\circ}C$. The initial concentration of the harvested culture was approximately $10^7$ to $10^9CFU\;ml^{-1}$. The culture solution was irradiated at different absorbed doses of 0.1, 0.2, 0.3, 0.4, 0.5, 0.7, and 1 kGy, respectively. The disinfection efficiency of persulfate with gamma radiation of 0.3 kGy against Escherichia coli K12 was 97.2% and while the gamma radiation only was 90.01% at 0.3 kGy. Therefore, it could be thought that addition of persulfate in the disinfection of Escherichia coli K12 can enhance the disinfection efficiency when it is used together with gamma radiation.

Expansion of Dusty H II Regions and Its Impact on Disruption of Molecular Clouds

  • Kim, Jeong-Gyu;Kim, Woong-Tae;Ostriker, Eve
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.58.3-59
    • /
    • 2015
  • Dynamical expansion of H II regions plays a key role in dispersing surrounding gas and therefore in limiting the efficiency of star formation in molecular clouds. We use analytic methods and numerical simulations to explore expansions of spherical dusty H II regions, taking into account the effects of direct radiation pressure, gas pressure, and total gravity of the gas and stars. Simulations show that the structure of the ionized zone closely follows Draine (2011)'s static equilibrium model in which radiation pressure acting on gas and dust grains balances the gas pressure gradient. Strong radiation pressure creates a central cavity and a compressed shell at the ionized boundary. We analytically solve for the temporal evolution of a thin shell, finding a good agreement with the numerical experiments. We estimate the minimum star formation efficiency required for a cloud of given mass and size to be destroyed by an HII region expansion. We find that typical giant molecular clouds in the Milky Way can be destroyed by the gas-pressure driven expansion of an H II region, requiring an efficiency of less than a few percent. On the other hand, more dense cluster-forming clouds in starburst environments can be destroyed by the radiation pressure driven expansion, with an efficiency of more than ~30 percent that increases with the mean surface density, independent of the total (gas+stars) mass. The time scale of the expansion is always smaller than the dynamical time scale of the cloud, suggesting that H II regions are likely to be a dominant feedback process in protoclusters before supernova explosions occurs.

  • PDF

손실 기판을 이용한 금속 부착형 RFID 태그 안테나의 복사 효율 향상 (Radiation Efficiency Improvement of RFID Tag Antenna for Metallic Objects Printed on Lossy Substrate)

  • 손해원;최원규;최길영
    • 한국전자파학회논문지
    • /
    • 제19권11호
    • /
    • pp.1265-1271
    • /
    • 2008
  • 본 논문에서는 FR4와 같은 저가의 고손실 기판을 이용하여 금속 부착형 태그 안테나를 설계하는 새로운 방법을 제안한다. 제안한 설계 방법은 유전 손실(dielectric loss)에 따른 기판 손실(substrate loss)을 크게 감소시킴으로써, 태그 안테나의 복사 효율(radiation efficiency)을 기존의 평면 역 F 안테나(planar inverted-F antenna: PIFA)에 비하여 2배 이상 향상시킨다. 본 논문에서는 제안한 방법에 따른 안테나의 등가 회로 모델을 정립하고 이를 체계적으로 분석하였으며, 시제품을 제작 및 측정하여 제안한 방법의 우수성을 입증하였다.

단순지지 사각 접수 평판의 방사효율 근사식에 관한 연구 (A Study on the Approximate Formula for Radiation Efficiency of a Simply Supported Rectangular Plate in Water)

  • 김현실;김재승;김봉기;김상렬
    • 한국소음진동공학회논문집
    • /
    • 제24권1호
    • /
    • pp.21-27
    • /
    • 2014
  • In this paper, an approximate formula for radiation efficiency of the plate surround by an infinite rigid baffle is studied. The plate is simply supported and one side is in contact with air, while other side with water. By assuming an infinite plate, the fluid loading effect is derived in terms of an effective mass. Based on the observation that the fluid loading effect decreases as frequency increases, the radiation efficiency formula at high frequency, which was originally derived for a plate vibrating in the air, is modified as the approximate formula for a submerged plate. The fluid loading effect is taken into account in the wavenumber of the plate. Comparisons of the approximate formula with the numerical results shows that they match well except the mid-frequency range in which numerical results show many oscillations. In numerically solving the fully coupled equations of motion, fourfold integrals of the impedance coefficients are reduced to single nonsingular integrals, which results in substantial reduction in computing time.

7-Diethylamino-4-methylcoumarin 기반 섬광체 제작 및 방사능 검출특성평가 (Fabrication of 7-Diethylamino-4-methylcoumarin-based Scintillator for Gamma Radiation Detection)

  • 민수정;노창현;서범경;홍상범
    • 방사선산업학회지
    • /
    • 제17권1호
    • /
    • pp.69-73
    • /
    • 2023
  • Commercially used organic scintillation materials (1,4 di[2-(5phenyloxazolyl)] benzene) have low solubility in solvents and a wide emission energy range, which causes a decrease in detection efficiency. In this study, an organic liquid scintillator with improved detection efficiency was developed using 7-Diethylamino-4-methylcoumarin material to compensate for the disadvantages of existing organic scintillation detectors. And to evaluate the applicability of radiation measurement, the performance of a commercial plastic detector was compared. As a result of analyzing the 60Co detection characteristics by applying 7-Diethylamino-4-methylcoumarin as an alternative to 1,4 di[2-(5phenyloxazolyl)] benzene, the detection efficiency was improved around 2% compared with commercial scintillator when the 7-Diethylamino-4-methylcoumarin content was 0.04 wt%. Based on the results of this study, the possibility of improving detection efficiency through scintillator material modification was confirmed. In addition, since it is possible to discriminate nuclide through the spectrum correction algorithm, it will be possible to inspect and classify various decommissioning wastes generated during the decommissioning process.

감마선 조사에 의한 Acetylsalicylic Acid의 분해 (Decomposition of Acetylsalicylic Acid by Gamma Ray)

  • 안영덕;이경훤;이오미;김태훈;정인하;유승호;이면주
    • 방사선산업학회지
    • /
    • 제5권3호
    • /
    • pp.253-258
    • /
    • 2011
  • Acetylsalicylic acid (ASA) has been issued recently in contaminated water environments because of potential impacts on ecosystem and public health. This study was aimed at investigating the possibility of ASA degradation using gamma ray irradiation. In addition, the use of sodium persulfate, hydrogen peroxide, ferrous sulfate were tested in order to examine a synergistic effect with gamma ray. The absorbed dose was ranged from 0.2 to 10 kGy and the concentration of oxidants were from 0.1 to 10 mM in this study. The concentration of ASA was gradually decreased corresponding to the increase of the absorbed dose. When soudium persulfate was simultaneously applied, most of the parent compound was completely degraded even at a low dose of 0.8 kGy. The removal efficiency of total organic carbon was 90% even at the highest dose of 10 kGy without sodium persulfate. However, the efficiency was dramatically enhanced up to 98% at the same dose by adding 10 mM of oxidants. It was suggested that hydroxyl radical ($OH{\cdot}$) and sulfate radical ($SO{_4}^-{\cdot}$) were formed in the system and made roles in degrading ASA at the same time.

Construction and Testing of a radiation-beam powered TA (ThermoAcoustic) washer for grease removal

  • ;;김영민;오승진;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.21-28
    • /
    • 2015
  • A small washer powered directly and solely by thermal radiation was constructed and tested to explore the feasibility of using solar energy or other types of thermal radiation for washing and cleaning. In principle, TA (ThermoAcoustic) washers have the benefits of simpler design and operation and fewer energy conversion processes, thus should be more energy efficient and cost less than electric washing/cleaning systems. The prototype TA converter we constructed could sustain itself with consistent fluid oscillations for more than 20 minutes when powered by either concentrated solar radiation or an IR (infrared) heater. The frequencies of water oscillations in the wash chamber ranged from 2.6 to 3.6 Hz. The overall conversion efficiency was lower than the typical efficiencies of TA engines. Change in water temperature had little effect on the oscillatory flow in the TA washer due to its low efficiency. On the other hand higher water temperatures enhanced grease removal considerably in our tests. Methods for measuring the overall conversion efficiency, frictional loss, and grease removal of the TA washing system we designed were developed and discussed.

Optimization of CORVUS Planning System with PRIMART Linac for Intensity Modulated Radiation Therapy

  • Lee, Se-Byeong;Jino Bak;Cho, Kwang-Hwan;Chu, Sung-sil;Lee, Suk;Suh, Chang-ok
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.83-85
    • /
    • 2002
  • Yonsei Cancer Center introduced an IMRT System at the beginning of February, 2002. The system consists of CORVUS(NOMOS) inverse planning machine, LANTIS(SIEMENS), PRIMEVIEW and PRIMART Linac(SIEMENS). The optimization of CORVUS planning system with PRIMART is an important work to get an efficient treatment plan. So, we studied two Finite Size Pencil Beams, 1.0 x 1.0 cm$^2$ and 0.5 x 1.0 cm$^2$, and four leaf transmission sets, 5%, 10%, 20%, 33%. We compared the dose distribution of target volume and delivery efficiency of the plan results.

  • PDF

PRESENT AND FUTURE OF SUPER HIGH-EFFICIENCY TANDEM SOLAR CELLS

  • Yamaguchi, Masafumi
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제11권11호
    • /
    • pp.37-45
    • /
    • 1998
  • In this paper, present status of super high-efficiency tandem solar cells has been reviewed and key issues for realizing super high-efficiency have also been discussed. In addition, the terretrial R&D activities of tandem cells, in the New Sunshine Program of MITI(Ministry of International Trade and Industry) and NEDO(New Energy and Industrial Technology Development Organization) in Japan are reviewed briefly. The mechanical stacked 3-junction cells of monolithically grown InGaP/GaAs 2-junction cells and InGaAs cells have reached the highest efficiency achieved in Japan of 33.3% at 1-sun AM1.5. This paper also reports high-efficiency InGaP/GaAs 2-junction solar cells with a world-record efficiency of 26.9% at AM0, 28$^{\circ}C$ and radiation damage recovery phenomena of the tandem cell performance due to minority-carrier injection under light illumination or forward bias, which causes defect annealing in InGaP top cells. Future prospects for realizing super-high efficiency and low-cost tandem solar cells are also described.

  • PDF