• Title/Summary/Keyword: radiation dosage

Search Result 174, Processing Time 0.024 seconds

Impact of radiation dose on concurrent chemoradiotherapy for limited-stage small-cell lung cancer

  • Park, Junhee;Kang, Min Kyu
    • Radiation Oncology Journal
    • /
    • v.36 no.1
    • /
    • pp.35-44
    • /
    • 2018
  • Purpose: To evaluate clinical outcomes according to radiation dose in patients with limited-stage small-cell lung cancer (LS-SCLC) treated with concurrent chemoradiotherapy (CCRT). Materials and Methods: From January 2006 to December 2015, 38 patients with LS-SCLC were treated with CCRT with etoposide and cisplatin. Total radiation doses ranged from 45 Gy to 66 Gy (1.8-2 Gy/fraction) and were classified into three groups: 45-54 Gy, 60-63 Gy, and 66 Gy. The impact of radiation dose on survival outcomes were evaluated. Toxicities were evaluated according to the Common Terminology Criteria for Adverse Events version 4.03. Results: The median follow-up period was 21 months. The 2-year overall survival (OS) and local failure-free survival (LFFS) rates were 45.8% and 67.5%, respectively. The 2-year LFFS rates were 33.3% for 45-54 Gy group, 68.6% for 60-63 Gy group, and 87.1% for 66 Gy group (p = 0.014). In multivariate analysis, radiation dose was a significant factor for LFFS (p = 0.015). Although radiation dose was not a significant factor for OS and disease-free survival (DFS) in multivariate analysis, both OS and DFS of 66 Gy group tended to be better than that of 45-63 Gy group in univariate analysis. However, there were no differences in severe toxicities among three groups. Conclusion: Higher radiation dose achieved better local control in patients with LS-SCLC treated with CCRT. In addition, a total dose of 66 Gy tended to improve OS and DFS.

Higher thoracic radiation dose is beneficial in patients with extensive small cell lung cancer

  • Yoon, Han Gyul;Noh, Jae Myoung;Ahn, Yong Chan;Oh, Dongryul;Pyo, Hongryull;Kim, Haeyoung
    • Radiation Oncology Journal
    • /
    • v.37 no.3
    • /
    • pp.185-192
    • /
    • 2019
  • Purpose: The effectiveness of thoracic radiation therapy (TRT) in extensive-stage small cell lung cancer (ES-SCLC) patients is increasingly reported, but there is no definite consensus on its application. The aim of this study was to identify factors associated with better outcomes of TRT among patients with ES-SCLC, focusing on whether a higher TRT dose could improve treatment outcome. Materials and Methods: The medical records of 85 patients with ES-SCLC who received TRT between January 2008 and June 2017 were retrospectively reviewed. Eligibility criteria were a biological effective dose with α/β = 10 (BED) higher than 30 Gy10 and completion of planned radiotherapy. Results: During a median follow-up of 5.3 months, 68 patients (80.0%) experienced disease progression. In univariate analysis, a BED >50 Gy10 was a significant prognostic factor for overall survival (OS; 40.8% vs. 12.5%, p = 0.006), progression-free survival (PFS; 15.9% vs. 9.6%, p = 0.004), and intrathoracic PFS (IT-PFS; 39.3% vs. 20.5%, p = 0.004) at 1 year. In multivariate analysis, a BED >50 Gy10 remained a significant prognostic factor for OS (hazard ratio [HR] = 0.502; 95% confidence interval [CI], 0.287-0.876; p = 0.015), PFS (HR = 0.453; 95% CI, 0.265-0.773; p = 0.004), and IT-PFS (HR = 0.331; 95% CI, 0.171-0.641; p = 0.001). Response to the last chemotherapy was also associated with better OS in both univariate and multivariate analysis. Conclusion: A TRT dose of BED >50 Gy10 may be beneficial for patients with ES-SCLC. Further studies are needed to select patients who will most benefit from high-dose TRT.

Dose comparison between prescription methods according to anatomical variations in intracavitary brachytherapy for cervical cancer

  • Choi, Euncheol;Kim, Jae Ho;Kim, Ok Bae;Byun, Sang Jun;Kim, Jin Hee;Oh, Young Kee
    • Radiation Oncology Journal
    • /
    • v.36 no.3
    • /
    • pp.227-234
    • /
    • 2018
  • Purpose: We compared how doses delivered via two-dimensional (2D) intracavitary brachytherapy (ICBT) and three-dimensional (3D) ICBT varied anatomically. Materials and Methods: A total of 50 patients who received 30 Gy of 3D ICBT after external radiotherapy (RT) were enrolled. We compared the doses of the actual 3D and 2D ICBT plans among patients grouped according to six anatomical variations: differences in a small-bowel V2Gy, small bowel circumference, the direction of bladder distension, bladder volume, sigmoid V3.5Gy, and sigmoid circumference. Seven dose parameters were measured in line with the EMBRACE recommendations. Results: In terms of bladder volume, the bladder and small-bowel D2cc values were lower in the 150-250 mL bladder volume subgroup; and the rectum, sigmoid, and bladder D2mL values were all lower in the >250 mL subgroup, for 3D vs. 2D ICBT. In the sigmoid V3.5Gy >2 mL subgroup, the sigmoid and bladder D2mL values were significantly lower for 3D than 2D ICBT. The bladder D2mL value was also significantly lower for 3D ICBT, as reflected by the sigmoid circumference. In patients with a small bowel V2.0Gy >10 mL or small bowel circumference >15%, most dose parameters were significantly lower for 3D than 2D ICBT. The bladder distension direction did not significantly affect the doses. Conclusion: Compared to 2D ICBT, a greater bladder volume can reduce the internal 3D ICBT organ dose without affecting the target dose.

Effect of Withaferin A on A549 Cellular Proliferation and Apoptosis in Non-small Cell Lung Cancer

  • Cai, Yong;Sheng, Zhao-Ying;Chen, Yun;Bai, Chong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.4
    • /
    • pp.1711-1714
    • /
    • 2014
  • Objective: To explore the effect of Withaferin A on A549 cellular proliferation and apoptosis in non-small cell lung cancer (NSCLC). Materials and Methods: NSCLC cell line A549 was selected to explore the effect of Withaferin A on A549 cellular proliferation, apoptosis and the PI3K/Akt signal pathway capable of regulating tumor biological behavior by assessment of cellular proliferation, cellular apoptotic rates and cellular cycling as well as by immuno-blotting. Results: Withaferin A could inhibit A549 cellular proliferation and the control rate was dosage-dependent (P<0.05), which also increased time-dependently with the same dosage of Withaferin A (P<0.05). The apoptotic indexes in A549 cells treated with 0, 2.5, 5.0, 10.0 and 20.0 ${\mu}mol{\cdot}L^{-1}$ Withaferin A for 48 h were significantly different (P<0.05). In addition, the apoptotic rates of each group in both early and advanced stages were higher than those in 0 ${\mu}mol{\cdot}L^{-1}$ (P<0.05), which were evidently higher after 48 h than those after 24 h (P<0.05). A549 cells treated by Withaferin A for 48 h were markedly lower in Bcl-2 level and obviously higher in Bax and cleaved caspase-3 levels than those treated by 0 ${\mu}mol{\cdot}L^{-1}$ Withaferin A (P<0.05), and there were significant differences among 5, 10 and 20 ${\mu}mol{\cdot}L^{-1}$ Withaferin A (P<0.05). The ratios of A549 cells treated by Withaferin A for 48 h in G0/G1 stage were higher than those in 0 ${\mu}mol{\cdot}L^{-1}$, while those in S and G2/M stages were obviously lower than those in G2/M stage, and there were significant differences in 5.0, 10.0 and 20.0 ${\mu}mol{\cdot}L^{-1}$ Withaferin A (P<0.05). Additionally, p-Akt/Akt values were in reverse association with dosage, and the differences were significant (P<0.05). Conclusion: Withaferin A can inhibit the proliferation and apoptosis of A549 cells by suppressing activation of the PI3K/Akt pathways.

Gamma Knife Radiosurgery for Trigeminal Neuralgia : Review and Update

  • Lee, Seunghoon;Lee, Jung-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.5
    • /
    • pp.633-639
    • /
    • 2022
  • Accurate diagnosis of trigeminal neuralgia (TN) is the starting point for optimal treatment. Gamma knife radiosurgery (GKRS) is currently regarded as one of the first-line treatment options for medically refractory TN. GKRS is a less invasive treatment with a low risk of complications than other surgical procedures that provides a favorable pain control Barrow Neurological Institute (BNI) I-IIIb rate of >75% at short-term follow-up. Drawbacks of GKRS include the latency period before pain relief and higher recurrence rate compared with microvascular decompression. Therefore, repeat treatment is necessary if the initial GKRS was effective but followed by recurrence. The concept of dose rate and the biologically effective dose of radiation has been actively studied in radiation oncology and is also applied in GKRS for TN to achieve high safety and efficacy by prescribing the optimal dose. Recent progress in functional imaging, such as diffusion tensor imaging, enables us to understand the pathophysiology of TN and predict the clinical outcome after GKRS. Here, we review TN, GKRS, and recent updates, especially in the concepts of radiation dose, diffusion tensor imaging studies, and repeat treatment in GKRS for TN.

Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion

  • Kim, Hyun Jun;Park, Eun Soo;Lee, Sang Ho;Park, Chan Hong;Chung, Seok Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.6
    • /
    • pp.933-943
    • /
    • 2021
  • Objective : Percutaneous pedicle screw (PPS) fixation is a needle based procedure that requires fluoroscopic image guidance. Consequently, radiation exposure is inevitable for patients, surgeons, and operation room staff. We hypothesize that reducing the production of radiation emission will result in reduced radiation exposure for everyone in the operation room. Research was performed to evaluate reduction of radiation exposure by modifying imaging manner and mode of radiation source. Methods : A total of 170 patients (680 screws) who underwent fusion surgery with PPS fixation from September 2019 to March 2020 were analyzed in this study. Personal dosimeters (Polimaster Ltd.) were worn at the collar outside a lead apron to measure radiation exposure. Patients were assigned to four groups based on imaging manner of fluoroscopy and radiation modification (pulse mode with reduced dose) : continuous use without radiation modification (group 1, n=34), intermittent use without radiation modification (group 2, n=54), continuous use with radiation modification (group 3, n=26), and intermittent use with radiation modification (group 4, n=56). Post hoc Tukey Honest significant difference test was used for individual comparisons of radiation exposure/screw and fluoroscopic time/screw. Results : The average radiation exposure/screw was 71.45±45.75 µSv/screw for group 1, 18.77±11.51 µSv/screw for group 2, 19.58±7.00 µSv/screw for group 3, and 4.26±2.89 µSv/screw for group 4. By changing imaging manner from continuous multiple shot to intermittent single shot, 73.7% radiation reduction was achieved in the no radiation modification groups (groups 1, 2), and 78.2% radiation reduction was achieved in the radiation modification groups (groups 3, 4). Radiation source modification from continuous mode with standard dose to pulse mode with reduced dose resulted in 72.6% radiation reduction in continuous imaging groups (groups 1, 3) and 77.3% radiation reduction in intermittent imaging groups (groups 2, 4). The average radiation exposure/screw was reduced 94.1% by changing imaging manner and modifying radiation source from continuous imaging with standard fluoroscopy setting (group 1) to intermittent imaging with modified fluoroscopy setting (group 4). A total of 680 screws were reviewed postoperatively, and 99.3% (675) were evaluated as pedicle breach grade 0 (<2 mm). Conclusion : The average radiation exposure/screw for a spinal surgeon can be reduced 94.1% by changing imaging manner and modifying radiation source from real-time imaging with standard dose to intermittent imaging with modified dose. These modifications can be instantly applied to any procedure using fluoroscopic guidance and may reduce the overall radiation exposure of spine surgeons.

Identification of CEA-interacting proteins in colon cancer cells and their changes in expression after irradiation

  • Yoo, Byong Chul;Yeo, Seung-Gu
    • Radiation Oncology Journal
    • /
    • v.35 no.3
    • /
    • pp.281-288
    • /
    • 2017
  • Purpose: The serum carcinoembryonic antigen (CEA) level has been recognized as a prognostic factor in colorectal cancer, and associated with response of rectal cancer to radiotherapy. This study aimed to identify CEA-interacting proteins in colon cancer cells and observe post-irradiation changes in their expression. Materials and Methods: CEA expression in colon cancer cells was examined by Western blot analysis. Using an anti-CEA antibody or IgG as a negative control, immunoprecipitation was performed in colon cancer cell lysates. CEA and IgG immunoprecipitates were used for liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. Proteins identified in the CEA immunoprecipitates but not in the IgG immunoprecipitates were selected as CEA-interacting proteins. After radiation treatment, changes in expression of CEA-interacting proteins were monitored by Western blot analysis. Results: CEA expression was higher in SNU-81 cells compared with LoVo cells. The membrane localization of CEA limited the immunoprecipitation results and thus the number of CEA-interacting proteins identified. Only the Ras-related protein Rab-6B and lysozyme C were identified as CEA-interacting proteins in LoVo and SNU-81 cells, respectively. Lysozyme C was detected only in SNU-81, and CEA expression was differently regulated in two cell lines; it was down-regulated in LoVo but up-regulated in SNU-81 in radiation dosage-dependent manner. Conclusion: CEA-mediated radiation response appears to vary, depending on the characteristics of individual cancer cells. The lysozyme C and Rab subfamily proteins may play a role in the link between CEA and tumor response to radiation, although further studies are needed to clarify functional roles of the identified proteins.

Correlation between the Portable X-ray and the Radiation Exposure dose in the Emergency Department: Cohort Study (응급실에서 이동식 단순 X-선 검사와 피폭선량과의 상관관계: 코호트 연구)

  • Kim, Yu Jung;Ahn, Hee Cheol;Sohn, You Dong;Ahn, Ji Yoon;Park, Seung Min;Lee, Won Woong;Lee, Young Hwan
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.11 no.2
    • /
    • pp.101-105
    • /
    • 2013
  • Purpose: This study was conducted in order to determine the relationship between the number of portable X-rays and the radiation exposure dose for emergency medical service providers working in the emergency department (ED). Methods: A prospective study was conducted from February 15, 2013 to May 15, 2013 in the ED in an urban hospital. Six residents, seven emergency medical technicians (EMT), and 24 nurses were enrolled. They wore a personal radiation dosimeter on their upper chest while working in the ED, and they stayed away from the portable X-ray unit at a distance of at least 1.8 m when the X-ray beam was generated. Results: The total number of portable x-rays was 2089. The average total radiation exposure dose of emergency medical service providers was $0.504{\pm}0.037$ mSv, and it was highest in the EMT group, 0.85(0.58-1.08) mSv. The average of the total number of portable X-rays was highest in the doctor group, 728.5(657.25-809). The relationship between the number of portable X-rays and the radiation exposure dose was not statistically significant(-0.186, p=0.269). Conclusion: Under the condition of staying away from the portable X-ray unit at a distance of least 1.8 m, the relationship between the number of portable X-rays and the radiation exposure dose was not statistically significant.

  • PDF

Leakage and scattered radiation from hand-held dental x-ray unit (이동용 치과 X선 발생장치의 누설 및 산란 선량에 관한 연구)

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.37 no.2
    • /
    • pp.65-68
    • /
    • 2007
  • Purpose: To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. Materials and Methods: For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR III was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of handheld dental X-ray unit were 70 kVp, 3 mA, 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. Results: The mean dose at the hand level when human skull DXTTR III was exposed with portable X-ray unit $6.39{\mu}Gy$, and the mean dose with fixed X-ray unit $3.03{\mu}Gy$ (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was $2.97{\mu}Gy$ and with fixed X-ray unit the mean dose was $0.68{\mu}Gy$ (p<0.01). Conclusions: The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography.

  • PDF

Radiation Effects on Electrical Treeing Characteristics of Low Density Polyethylene (저밀도 폴리에틸렌의 방사선 조사에 따른 전기 트리 특성 변화)

  • Lee, Chung;Shin, Hee-Kyung;Kim, Ki-Yup;Park, Soo-Gil;Ryu, Boo-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1992-1994
    • /
    • 1999
  • Dicumyl peroxide (DCP) is used for crosslinking agent in general. And the correlation between polyethylene and DCP is significant in particular radiation environment. On this paper, The effects on $Co^{60}{\gamma}$-ray irradiation of polyethylene doped dicumyl peroxide(DCP) were investigated. We experimented on electrical properties as following; electrical tree inception and growing type for applying AC step voltage, AC breakdown strength, volume resistivity, capacitance and dissipation factor at high frequency as increasing dosage. Also, chemical analysis was performed TGA, gel content.

  • PDF