• Title/Summary/Keyword: radiation dosage

Search Result 174, Processing Time 0.028 seconds

Radiology Residents' Independent Diagnosis of Appendicitis Using 2-mSv Computed Tomography: A Secondary Analysis of a Large Pragmatic Randomized Trial

  • Jungheum Cho;Hae Young Kim;Seungjae Lee;Ji Hoon Park;Kyoung Ho Lee
    • Korean Journal of Radiology
    • /
    • v.24 no.6
    • /
    • pp.529-540
    • /
    • 2023
  • Objective: To compare the diagnostic performance and clinical outcomes of 2-mSv computed tomography (CT) and conventional-dose CT (CDCT), following radiology residents' interpretation of CT examinations for suspected appendicitis. Materials and Methods: Altogether, 3074 patients with suspected appendicitis aged 15-44 years (28 ± 9 years, 1672 females) from 20 hospitals were randomly assigned to the 2-mSv CT (n = 1535) or CDCT (n = 1539) groups in a pragmatic trial from December 2013 and August 2016. Overall, 107 radiology residents participated in the trial as readers in the form of daily practice after online training for 2-mSv CT. They made preliminary CT reports, which were later finalized by attending radiologists via addendum reports, for 640 and 657 patients in the 2-mSv CT and CDCT groups, respectively. We compared the diagnostic performance of the residents, discrepancies between preliminary and addendum reports, and clinical outcomes between the two groups. Results: Patient characteristics were similar between the 640 and 657 patients. Residents' diagnostic performance was not significantly different between the 2-mSv CT and CDCT groups, with a sensitivity of 96.0% and 97.1%, respectively (difference [95% confidence interval {CI}], -1.1% [-4.9%, 2.6%]; P = 0.69) and specificity of 93.2% and 93.1%, respectively (0.1% [-3.6%, 3.7%]; P > 0.99). The 2-mSv CT and CDCT groups did not significantly differ in discrepancies between the preliminary and addendum reports regarding the presence of appendicitis (3.3% vs. 5.2%; -1.9% [-4.2%, 0.4%]; P = 0.12) and alternative diagnosis (5.5% vs. 6.4%; -0.9% [-3.6%, 1.8%]; P = 0.56). The rates of perforated appendicitis (12.0% vs. 12.6%; -0.6% [-4.3%, 3.1%]; P = 0.81) and negative appendectomies (1.9% vs. 1.1%; 0.8% [-0.7%, 2.3%]; P = 0.33) were not significantly different between the two groups. Conclusion: Diagnostic performance and clinical outcomes were not significantly different between the 2-mSv CT and CDCT groups following radiology residents' CT readings for suspected appendicitis.

Appendiceal Visualization on 2-mSv CT vs. Conventional-Dose CT in Adolescents and Young Adults with Suspected Appendicitis: An Analysis of Large Pragmatic Randomized Trial Data

  • Jungheum Cho;Youngjune Kim;Seungjae Lee;Hooney Daniel Min;Yousun Ko;Choong Guen Chee;Hae Young Kim;Ji Hoon Park;Kyoung Ho Lee;LOCAT Group
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.413-425
    • /
    • 2022
  • Objective: We compared appendiceal visualization on 2-mSv CT vs. conventional-dose CT (median 7 mSv) in adolescents and young adults and analyzed the undesirable clinical and diagnostic outcomes that followed appendiceal nonvisualization. Materials and Methods: A total of 3074 patients aged 15-44 years (mean ± standard deviation, 28 ± 9 years; 1672 female) from 20 hospitals were randomized to the 2-mSv CT or conventional-dose CT group (1535 vs. 1539) from December 2013 through August 2016. A total of 161 radiologists from 20 institutions prospectively rated appendiceal visualization (grade 0, not identified; grade 1, unsure or partly visualized; and grade 2, clearly and entirely visualized) and the presence of appendicitis in these patients. The final diagnosis was based on CT imaging and surgical, pathologic, and clinical findings. We analyzed undesirable clinical or diagnostic outcomes, such as negative appendectomy, perforated appendicitis, more extensive than simple appendectomy, delay in patient management, or incorrect CT diagnosis, which followed appendiceal nonvisualization (defined as grade 0 or 1) and compared the outcomes between the two groups. Results: In the 2-mSv CT and conventional-dose CT groups, appendiceal visualization was rated as grade 0 in 41 (2.7%) and 18 (1.2%) patients, respectively; grade 1 in 181 (11.8%) and 81 (5.3%) patients, respectively; and grade 2 in 1304 (85.0%) and 1421 (92.3%) patients, respectively (p < 0.001). Overall, undesirable outcomes were rare in both groups. Compared to the conventional-dose CT group, the 2-mSv CT group had slightly higher rates of perforated appendicitis (1.1% [17] vs. 0.5% [7], p = 0.06) and false-negative diagnoses (0.4% [6] vs. 0.0% [0], p = 0.01) following appendiceal nonvisualization. Otherwise, these two groups were comparable. Conclusion: The use of 2-mSv CT instead of conventional-dose CT impairs appendiceal visualization in more patients. However, appendiceal nonvisualization on 2-mSv CT rarely leads to undesirable clinical or diagnostic outcomes.

Usefulness in Evaluation of NM Image which It Follows in Onco. Flash Processing Application (Onco. Flash Processing 적용에 따른 핵의학 영상의 유용성 평가)

  • Kim, Jung-Soo;Kim, Byung-Jin;Kim, Jin-Eui;Woo, Jae-Ryong;Kim, Hyun-Joo;Shin, Heui-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.13-18
    • /
    • 2008
  • Purpose: The image processing method due to the algorism which is various portion nuclear medical image decision is important it makes holds. The purpose of this study is it applies hereupon new image processing method SIEMENS (made by Pixon co.) Onco. flash processing reconstruction and the comparison which use the image control technique of existing the clinical usefulness it analyzes with it evaluates. Materials & Methods: 1. Whole body bone scan-scan speed 20 cm/min, 30 cm/min & 40 cm/min blinding test 2. Bone static spot scan-regional view 200 kcts, 400 kcts for chest, pelvis, foot blinding test 3. 4 quadrant-bar phantom-20000 kcts visual evaluation 4. LSF-FWHM resolution comparison ananysis. Results: 1. Raw data (20 cm/min) & processing data (30 cm/min)-similar level image quality 2. Low count static image-image quality clearly improved at visual evaluation result. 3. Visual evaluation by quadrant bar phantom-rising image quality level 4. Resolution comparison evaluation (FWHM)-same difference from resolution comparison evaluation Conclusion: The study which applies a new method Onco. flash processing reconstruction, it will be able to confirm the image quality improvement which until high level is clearer the case which applies the method of existing better than. The new reconstruction improves the resolution & reduces the noise. This enhances the diagnostic capabilities of such imagery for radiologists and physicians and allows a reduction in radiation dosage for the same image quality. Like this fact, rising of equipment availability & shortening the patient waiting move & from viewpoint of the active defense against radiation currently becomes feed with the fact that it will be the useful result propriety which is sufficient in clinical NM.

  • PDF

Growth Inhibition against Contaminants in Aseptic Chocolate Milk Using Physicochemical Methods (물리.화학적 처리에 의한 멸균 초콜릿 우유 오염균의 생육억제 효과)

  • Choi, Moon-Kyoung;Yoon, So-Young;Lee, So-Young;Kim, Koth-Bong-Woo-Ri;Lee, Chung-Jo;Jung, Ji-Yeon;Kwak, Ji-Hee;Kim, Min-Ji;Kim, Dong-Hyun;SunWoo, Chan;Lee, Ju-Woon;Byun, Myung-Woo;Ahn, Dong-Hyun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.8
    • /
    • pp.1157-1163
    • /
    • 2011
  • This study was conducted to investigate the cause of microbiological contaminants in aseptic chocolate milk and evaluate the effect of a physicochemical treatment on the growth inhibition of isolated bacterial strains. The bacterium isolated from aseptic chocolate milk was identified as Bacillus lentus and was named B. lentus M1. In the heat and pH treatment, the growth of B. lentus was inhibited at 110$^{\circ}C$ for >15 min and at pH's <5 and >10. An electrolyzed water treatment against B. lentus M1, revealed 5 mm growth past the inhibition zone. The effect of ozone gas on B. lentus M1 growth was evaluated using viable cell counts. When the initial number of B. lentus M1 was $10^2$ and $10^3$ CFU, the bacteria were completely suppressed by ozone gas treatment for 10 and 30 min, respectively. In a microwave treatment, B. lentus M1 was sterilized following microwave treatment for 1 min. As the result of ${\gamma}$-irradiation against B. lentus M1, numbers decreased as the ${\gamma}$-irradiation dosage increased. These results show the growth inhibition effects against contaminants in aseptic chocolate milk using physicochemical treatments.