• Title/Summary/Keyword: radiation concentration

Search Result 1,018, Processing Time 0.03 seconds

Sensitivity Study of Simulated Sea-Ice Concentration and Thickness Using a Global Sea-Ice Model (CICE) (전구 해빙모델(CICE)을 이용한 해빙 농도와 해빙 두께 민감도 비교)

  • Lee, Su-Bong;Ahn, Joong-Bae
    • Atmosphere
    • /
    • v.24 no.4
    • /
    • pp.555-563
    • /
    • 2014
  • The impacts of dynamic and thermodynamic schemes used in the Community Ice CodE (CICE), the Los Alamos sea ice model, on sea ice concentration, extent and thickness over the Arctic and Antarctic regions are evaluated. Using the six dynamic and thermodynamic schemes such as sea ice strength scheme, conductivity scheme, albedo type, advection scheme, shortwave radiation method, and sea ice thickness distribution approximation, the sensitivity experiments are conducted. It is compared with a control experiment, which is based on the fixed atmospheric and oceanic forcing. For sea ice concentration and extent, it is found that there are remarkable differences between each sensitivity experiment and the control run over the Arctic and Antarctic especially in summer. In contrast, there are little seasonal variations between the experiments for sea ice thickness. In summer, the change of the albedo type has the biggest influence on the Arctic sea ice concentration, and the Antarctic sea ice concentration has a greater sensitivity to not only the albedo type but also advection scheme. The Arctic sea ice thickness is significantly affected by the albedo type and shortwave radiation method, while the Antarctic sea ice thickness is more sensitive to sea ice strength scheme and advection scheme.

Development of Relative Calibration Method for Measurement of Radon and Application (라돈농도 측정을 위한 고체비적검출기의 상대교정법 개발 및 응용)

  • Park, Young-Woong;Yang, Hyun-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.243-250
    • /
    • 1997
  • A relative-calibration-method of solid-state-track-detector for measurement of radon in air has been developed, and the concentration of radon in each room of a 15th-floor-apartment was measured by using the relative calibrated SSTD. There is a tendency to decrease the concentration of radon when the floor is higher, but the main factor to reduce the concentration of radon in room appeared to be ventilation rate. Average concentration of radon of the 15th-floor-apartment was $1.50{\pm}0.51pCi/l$, and the highest and the lowest concentration of radon were $2.68{\pm}0.32pCi/l$, $0.69{\pm}0.16pCi/l$ respectively.

  • PDF

Ammonia Nitrogen Removal and Recovery from Swine Wastewater by Microwave Radiation

  • La, Joohee;Kim, Taeyoung;Jang, Jae Kyung;Chang, In Seop
    • Environmental Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.381-385
    • /
    • 2014
  • Microwave (MW) radiation was developed to remove and recover ammonia nitrogen in the real swine wastewater. The effect of operating parameters of MW radiation such as initial pH, power, radiation time, aeration, and stirring for removal ammonia nitrogen in swine wastewater was determined. The pH, radiation time, and power were significantly influenced on the removal of ammonia nitrogen, and aeration and stirring showed relatively minor effect on the removal of ammonia nitrogen. Optimum condition was achieved to retrieve the nitrogen efficiently at pH 11, 700 W for 5 min in MW radiation process. Through this process, 83.1% of ammonia nitrogen concentration was reduced in swine wastewater and also 82.6% of ammonia nitrogen was recovered as ammonium sulfate at the optimized condition. The high ammonia removal and recovery efficiency of the MW radiation method indicated that MW radiation was an effective technique to remove and recover ammonia nitrogen in the swine wastewater.

The Effect of 5-FU and Radiation on A549 Cells In Vitro (시험관내의 인체폐암 세포 A549의 방사선 및 5-Fluorouracil에 대한 효과)

  • Lee, Myung-Za;Chun, Ha-Chong;Lee, Won-Young
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.1-13
    • /
    • 1989
  • Effects of ionizing radiation alone and combined with chemotherapy on tumor growth and it's clonal specificity monitored by changes in distribution of chromosome number were studies in A549 ceil line originated from human adenocarcinoma of the lung. Radiation (300 rad, 600 rad and 900 rad) were delivered with or without 5-FU. Forty eight hours later, 57.5% of growth inhibition of cell w8s seen in cells treated with 5-FU concentration of $0.4{\mu}g/ml$ for 24hr exposure. Cell survival curves after radiation with and without 5-FU were made. Chromosomal analysis of cells in metaphase in control, and in cells treated with 300 rad of radiation, or $0.4{\mu}g/ml$ of 5-FU treatment, and combined treatment of both were done to examine the changes in ploidy and number of chromosome. Radiation combined with S-FU enhanced growth inhibition of A549 cells. However, no evidence of synergegic effects in growth. inhibition was observed in the cells treated with the combination therapy. Pattern of chromosomal distribution of survived cells were shifted from hyperploidy to hypoploidy by single dose of radiation (300 rad). As radiation dose increased a large number of hypoploidy cells were observed. Following treatment of cells with 5-FU, chomosomal distribution of survived cells were also shifted to hypodiploidy which were seen in cells treated with radiation, The ceil treated with 5-FU and fellowed by radiation within 24 hrs had cell with increased number of hypodiploidy cells. Almost same type of chromosomal changes were reproduced in cells treated with combined treatment with radiation and 5-FU. Minor differences were that cells with fewer number of chromosome were more frequent in cells treated with combined therapy. Further increase in cells of hypoploidy (93%) having 1-10 chromosome were induced by additional radiation. Therefore, the enhanced therapeutic effect of 5-FU combined with radiation of A549 cells appeared to be additive rather than synergistic.

  • PDF

Effect of Persulfate on Disinfection of Escherichia coli K12 by Gamma Radiation (감마선을 이용한 Escherichia coli K12의 살균에서 persulfate의 효과)

  • Lee, O Mi;Kim, Tae Hun;Yu, Seungho;Jung, Inha;Lee, Myun Joo
    • Journal of Radiation Industry
    • /
    • v.5 no.1
    • /
    • pp.63-67
    • /
    • 2011
  • A comparative experiment was conducted to compare the effects of persulfate with gamma radiation on the disinfection efficiencies against Escherichia coli K12. The microorganism used for the disinfection experiments were prepared by transferring a bacterial stock culture into a 50 ml nutrient broth an incubating for 24 hrs at $37^{\circ}C$. The initial concentration of the harvested culture was approximately $10^7$ to $10^9CFU\;ml^{-1}$. The culture solution was irradiated at different absorbed doses of 0.1, 0.2, 0.3, 0.4, 0.5, 0.7, and 1 kGy, respectively. The disinfection efficiency of persulfate with gamma radiation of 0.3 kGy against Escherichia coli K12 was 97.2% and while the gamma radiation only was 90.01% at 0.3 kGy. Therefore, it could be thought that addition of persulfate in the disinfection of Escherichia coli K12 can enhance the disinfection efficiency when it is used together with gamma radiation.

Fabrication and Characterization of PVA/CMC Hydrogels by Freezing-Thawing Technique and Gamma-Ray Irradiation (동결/융해와 방사선 가교법에 의한 PVA/CMC 수화젤의 제조 및 특성 평가)

  • Jo, Sun-Young;Lim, Youn-Mook;Youn, Min-Ho;Gwon, Hui-Jeong;Park, Jong-Seok;Nho, Young-Chang;Shin, Heung-Soo
    • Polymer(Korea)
    • /
    • v.33 no.6
    • /
    • pp.551-554
    • /
    • 2009
  • Poly (vinyl alcohol) (PVA) and carboxymethyl cellulose (CMC) have received increasing attention in biomedical and biochemical applications because of their properties such as being water-soluble and biocompatible. In this study, a PVA/CMC hydrogel applicable to artificial cartilage was prepared by a freezing-thawing technique and a gamma-ray irradiation. The solid concentration of PVA was 7 wt% and the concentration of CMC was 4 wt%. The freezing/thawing process was repeated twice and the dose of gamma-ray irradiated was 30 kGy. Results of gelation before and after gamma-ray irradiation were similar, but the swelling degree decreased and compressive strength increased. The cytotoxicity was investigated with CCK-8 assay.

Radiation stability and radiolysis mechanism of hydroxyurea in HNO3 solution: Alpha, beta, and gamma irradiations

  • Yilin Qin;Wei Liao;Tu Lan;Fengzhen Li;Feize Li;Jijun Yang;Jiali Liao;Yuanyou Yang;Ning Liu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4660-4670
    • /
    • 2022
  • Hydroxyurea (HU) is a novel salt-free reductant used potentially for the separation of U/Pu in the advanced PUREX process. In this work, the radiation stability of HU were systematically investigated in solution by examining the effects of the type of rays (α, β, and γ irradiations), the absorbed dose (10-50 kGy), and the HNO3 concentration (0-3 mol L-1). The influence degree on HU radiolysis rates followed the order of the absorbed dose > the ray type > the HNO3 concentration, but the latter two had moderate effects on HU radiolysis products where NH4+ and NO2- were found to be the most abundant ones, suggesting that the differences of α, β, and γ rays should be considered in the study of irradiation effects. The radiolysis mechanism was explored using density functional theory (DFT) calculations, and it proposed the dominant radiolysis paths of HU, indicating that the radiolysis of HU was mainly a free radical reaction among ·H, eaq-, H2O, intermediates, and the radiolytic free radical fragments of HU. The results reported here provide valuable insights into the mechanistic understanding of HU radiolysis under α, β, and γ irradiations and reliable data support for the application of HU in the reprocessing of spent fuel.

Change of Biomagnetic Field around Acupoints of Kigong Master during Qi radiation (발공중인 기공자 경혈주위의 미소자기장 관찰)

  • Jang Kyeong Seon;Choi Chan Hun;Jeong Chan Won;Lee Yoon Ho;Yoon Yoo Sik;So Cheal Ho
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.3
    • /
    • pp.537-541
    • /
    • 2002
  • When a Kigong master concentrates the Qi at Yintang, Laogong(P8), Qihai(CV6) meridian points during Kigong state, the change of magnetic field around acupoints Yintang, Laogong points has been measured using DROS-SQUID apparatus. After smoothing process of the continuously measured magnetic signal around acupoints for a few minutes, we could observe that a series of peaks, magnitude of 1~2 pT and period of 5 sec, appeared and find that these peaks were clearly changed as if switch on and off according to Qi concentration state. Before Qi radiation, a series of the peaks measured on Yintang or Laogong point of a Kigong master shows one of either SW-ON state or SW-OFF state as initial state. During Qi radiation, its state becomes inverse of initial state. After Qi radiation, it returns to the initial state for some cases (called P type ; push button switch type) or it remains inversion state for other cases (called T type; toggle switch type). From the data of peaks measured at different position from the Qi concentration acupoint, we found that the Qi radiation on an acupoint makes the switching effect even not at the acupoint that Qi is concentrated but at the other acupoints that Qi is not concentrated.

A Study of the Pollutant Formation and Spectral Radiation Properties in Ceramic Fiber Radiant Burner (세라믹 화이버 버너의 배기 배출물과 분광학적 특성에 관한 연구)

  • Jeong, Yong-Ki;Kim, Young-Soo;Lee, Dae-Rae;Yang, Dae-Bong;Ryu, Jung-Wan;Yun, Alexander;Ha, Man-Young;Chang, Young-June;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.9
    • /
    • pp.790-798
    • /
    • 2007
  • An experimental study was performed to investigate the effects of mixing quality, inlet pressure, nozzle diameter on CO, NO emission and radiation characteristics in porous ceramic fiber radiant burners. Observations of combustion characteristics occurring inside the burner system which was insulated fiber mat, were investigated by measuring emission and radiation characteristics. Combustion was achieved at the firing rate of $88{\sim}99\;kcal/hr$, inlet pressure of $100{\sim}250mmH_2O$. The fiber burner exhibit significant both spectral intensity peaks in the bands at $2.5{\mu}m\;and\;4.0{\mu}m$ relatively. There is a small difference in the variable mixing tube. However spectral intensity increased with the firing rate. CO emissions were found to be strongly dependent on the operating conditions. There was a tendency that CO concentration increased as the firing rate increases. the reason for rise of CO concentration is that is becomes it the relatively rich condition. Relatively low NO emission was observed for the whole operating range. The NO concentration is maximal at the firing rate of approximately 2850 kcal/hr and an air ratio of about 1.

Quantitative Analysis of Radiation-induced Hydrocarbons in Irradiated Chicken at Various Dose Levels

  • Kim, Eun-Ah;Lee, Hae-Jung;Yang, Jae-Seung;Kim, Kyong-Su
    • Preventive Nutrition and Food Science
    • /
    • v.3 no.4
    • /
    • pp.339-343
    • /
    • 1998
  • Gamma-irradiated chicken at dose levels of 0.1 to 10 kGy was subjected to detection of radiation-induced hydrocarbons whether irradiated or not. The hydrocarbons extracted from chicken fat were separated by florishil column chromatography and identified with GC-FID and GC/MS methods. Eight kinds of hydrocarbons were identified from irradiated chicken, among which 1, 7-hexadecadiene and 8-heptadencene were detected as major compounds , Remarkably radiation-induced hydrocarbons in irradiated chiken were detected at 0.5kGy and over. The concentration of radiation-induced hydrocarbons was relatively constant during 16 weeks.

  • PDF