• Title/Summary/Keyword: radiation concentration

Search Result 1,018, Processing Time 0.03 seconds

Development of an Efficiency Calibration Model Optimization Method for Improving In-Situ Gamma-Ray Measurement for Non-Standard NORM Residues (비정형 공정부산물 In-Situ 감마선 측정 정확도 향상을 위한 효율교정 모델 최적화 방법 개발)

  • WooCheol Choi;Tae-Hoon Jeon;Jung-Ho Song;KwangPyo Kim
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.471-479
    • /
    • 2023
  • In In-situ radioactivity measurement techniques, efficiency calibration models use predefined models to simulate a sample's geometry and radioactivity distribution. However, simplified efficiency calibration models lead to uncertainties in the efficiency curves, which in turn affect the radioactivity concentration results. This study aims to develop an efficiency calibration optimization methodology to improve the accuracy of in-situ gamma radiation measurements for byproducts from industrial facilities. To accomplish the objective, a drive mechanism for rotational measurement of an byproduct simulator and a sample was constructed. Using ISOCS, an efficiency calibration model of the designed object was generated. Then, the sensitivity analysis of the efficiency calibration model was performed, and the efficiency curve of the efficiency calibration model was optimized using the sensitivity analysis results. Finally, the radiation concentration of the simulated subject was estimated, compared, and evaluated with the designed certification value. For the sensitivity assessment of the influencing factors of the efficiency calibration model, the ISOCS Uncertainty Estimator was used for the horizontal and vertical size and density of the measured object. The standard deviation of the measurement efficiency as a function of the longitudinal size and density of the efficiency calibration model decreased with increasing energy region. When using the optimized efficiency calibration model, the measurement efficiency using IUE was improved compared to the measurement efficiency using ISOCS at the energy of 228Ac (911 keV) for the nuclide under analysis. Using the ISOCS efficiency calibration method, the difference between the measured radiation concentration and the design value for each simulated subject measurement direction was 4.1% (1% to 10%) on average. The difference between the estimated radioactivity concentration and the design value was 3.6% (1~8%) on average when using the ISOCS IUE efficiency calibration method, which was closer to the design value than the efficiency calibration method using ISOCS. In other words, the estimated radioactivity concentration using the optimized efficiency curve was similar to the designed radioactivity concentration. The results of this study can be utilized as the main basis for the development of regulatory technologies for the treatment and disposal of waste generated during the operation, maintenance, and facility replacement of domestic byproduct generation facilities.

Implementation of Popular Radon Detector Using Pin Photodiode (핀 포토다이오드를 이용한 보급형 라돈 검출기의 구현)

  • Yun, Sung-Ha;Kim, Jae-Hak;Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.99-106
    • /
    • 2016
  • When radon is staying at alveoli and bronchial tubes, the collapse of radon creates progeny nuclides (alpha ray, beta ray, gamma ray, etc.). They emit radiation causing a mutation in the chromosome of the cell, resulting in lung cancer. In other words, the main cause of lung cancer is radiation emitting as the result of radon collapse rather than radon gas. The 82% of radiation exposed to people is the natural radiation. Most of the natural radiation is radon. If we properly control the concentration of radon indoors, the probability of occurrence of lung cancer could be decreases to be 70%. Until now, to measure the indoor radon concentration, imported radon sensors are needed. So, DB construction of indoor radon emission and popular radon measuring apparatus should be developed. In this paper, we propose the radon detecting method using PIN photodiode. Also, we confirmed the PIN photodiode could be used as radon sensor module through some experimental studies.

Microwave Radiation-Assisted Chitin Deacetylation: Optimization by Response Surface Methodology (RSM)

  • Iqmal Tahir;Karna Wijaya;Mudasir;Dita Krismayanti;Aldino Javier Saviola;Roswanira Abdul Wahab;Amalia Kurnia Amin;Wahyu Dita Saputri;Remi Ayu Pratika
    • Korean Journal of Materials Research
    • /
    • v.34 no.2
    • /
    • pp.85-94
    • /
    • 2024
  • The optimization of deacetylation process parameters for producing chitosan from isolated chitin shrimp shell waste was investigated using response surface methodology with central composite design (RSM-CCD). Three independent variables viz, NaOH concentration (X1), radiation power (X2), and reaction time (X3) were examined to determine their respective effects on the degree of deacetylation (DD). The DD of chitosan was also calculated using the baseline approach of the Fourier Transform Infrared (FTIR) spectra of the yields. RSM-CCD analysis showed that the optimal chitosan DD value of 96.45 % was obtained at an optimized condition of 63.41 % (w/v) NaOH concentration, 227.28 W radiation power, and 3.34 min deacetylation reaction. The DD was strongly controlled by NaOH concentration, irradiation power, and reaction duration. The coefficients of correlation were 0.257, 0.680, and 0.390, respectively. Because the procedure used microwave radiation absorption, radiation power had a substantial correlation of 0.600~0.800 compared to the two low variables, which were 0.200~0.400. This independently predicted robust quadratic model interaction has been validated for predicting the DD of chitin.

Performance of the RI Exhaust Filter at Chosun University Cyclotron Facility and 18F Emission Reduction (조선대학교 사이클로트론 시설의 RI 배기필터 성능평가 및 18F 배출저감 연구)

  • Jeong, Cheol-Ki;Jang, Han;Lee, Goung-Jin
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2017
  • Recently, the number of PET cyclotrons has increased in Korea. A cyclotron mainly produces $^{18}F$, which is used for the production of [$^{18}F$]FDG, a cancer diagnostic radiopharmaceutical. For radiation protection, the discharge control standard under the Nuclear Safety Act limits the radioactive concentration of $^{18}F$ in the exhaust discharged from a nuclear power utilization facility to below $2,000Bq\;m^{-3}$. However, the radioactive concentration of $^{18}F$ discharged during [$^{18}F$]FDG production at the cyclotron facility at Chosun University is maintained at about $1,500Bq\;m^{-3}$ on average, which is 75% of the concentration limit of the discharge control standard, and temporarily exceeds the standard as per the real-time monitoring results. This study evaluated the performance of the exhaust filter unit of the cyclotron facility at Chosun University by assessing the concentration of $^{18}F$ in the exhaust, and an experiment was conducted on the discharge reduction, where $^{18}F$ is discharged without reacting with the FDG precursors during [$^{18}F$]FDG synthesis and is immediately captured by the [$^{18}F$]FDG automatic synthesis unit. Based on the performance evaluation results of the exhaust filter at the cyclotron facility of Chosun University, the measured capture efficiency before and after the filter was found to be 92%. Furthermore, the results of the discharge reduction experiment, where the exhaust $^{18}F$ was immediately captured by the [$^{18}F$]FDG synthesizer, showed a very satisfactory 94.3% reduction in the concentration of discharge compared to the existing discharge concentration.

Preparation of Son Exchange Kapok Fiber by Radiation Polymerization (방사선 중합법에 의한 Kapok 이온교환 섬유의 합성)

  • Cho, In-Hee;Kang, Phil-Hyun;Lim, Youn-Mook;Choi, Jae-Hak;Hwang, Taek-Sung;Nho, Young-Chang
    • Polymer(Korea)
    • /
    • v.31 no.6
    • /
    • pp.512-517
    • /
    • 2007
  • The grafting of styrene, glycidylmethacrylate (GMA) or acrylic acid (AAc) onto kapok fiber were performed by $Co_{60}\;{\gamma}-ray$ radiation-induced graft copolymerization. Degree of grafting (DG) of copolymers were increased with increasing monomer concentration and radiation dose. In addition to we confirmed the introduced functional group and measured ion exchange capacity. Morphology of the ion exchange fibers and their structures were analyzed by SEM and FT-IR.

Estimation of 222Rn Concentration in the Lower Troposphere during Precipitation Using Wet Scavenging Model for its Decay Products

  • Takeyasu, Masanori;Takeishi, Minoru
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.1
    • /
    • pp.20-25
    • /
    • 2010
  • The gaseous $^{222}Rn$ concentration at the level of clouds was estimated by using the wet scavenging model of its decay products with the observed data of environmental radiation at the ground. And the origin of the $^{222}Rn$ was also discussed. The estimation was done for a precipitation event on Dec. 26-27, 2003, when a large increase of the radiation was observed in Tokai-mura in Ibaraki, Japan. From a backward trajectory analysis, the origin of $^{222}Rn$ atoms for that event was traced back to the northeastern part of China, and it was expected that the large amount of $^{222}Rn$ emitted in the northeastern part of China was transported to Tokai-mura by the Eurasian continental air mass.

The Variation of Radiation Transmittance by the cw 1.07 ㎛ Fiber Laser and Water Aerosol Interaction

  • Koh, Hae Seog;Shin, Wan Soon;Jeon, Min Yong;Park, Byung Suh
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.191-195
    • /
    • 2012
  • Among the atmospheric effect of laser propagation, the variations of the radiation transmittance by water aerosol evaporation have quantitatively been investigated. When the aerosol was exposed by a 1.07 ${\mu}m$ cw fiber laser, the increased amount of the transmittance variation was a maximum of 19.1% and the volume concentration variation of aerosol was observed as an increasing of laser intensity. Also, significant irregularity of refractive index was not found in the heated area during the continuous laser heating.

Synthesis of Synchrotron Radiation-induced Gold Nanoparticles as Radiosensitizer in Radiotherapy

  • Oh, Se An;Park, Jae Won;Kim, Seong Hoon;Kim, Sung Kyu;Yea, Ji Woon;Lee, Su Yong;Kang, Hyon Chol
    • Journal of the Korean Physical Society
    • /
    • v.73 no.11
    • /
    • pp.1744-1749
    • /
    • 2018
  • This study investigated the feasibility of synthesizing GNPs using synchrotron radiation X-ray for use as a radiosensitizer in radiotherapy, and examined the morphology of the GNPs. Different concentration ratios of 4-mM gold precursor aqueous solution and 4-mM $NaHCO_3$ were mixed. This gold precursor aqueous solution was continuously irradiated with synchrotron radiation in the 4B X-ray microdiffraction beamline of Pohang Light Source (PLS)-II in Korea. The SEM, EDS, TEM, and XRD spectra of the GNPs synthesized using the synchrotron radiation were investigated. The GNPs synthesized using the synchrotron radiation were nanocrystals predominantly in the (111) direction of the face-centered cubic structure. We found that the shape of the gold nanoparticles was icosahedron at the molar concentrations of 0.25 mM:0.25 mM and 0.5 mM:0.5 mM mixed with 4 mM $HAuCl_4{\cdot}3H_2O$ and 4 mM $NaHCO_3$ solutions.

Numerical Study of Entropy Generation with Nonlinear Thermal Radiation on Magnetohydrodynamics non-Newtonian Nanofluid Through a Porous Shrinking Sheet

  • Bhatti, M.M.;Abbas, T.;Rashidi, M.M.
    • Journal of Magnetics
    • /
    • v.21 no.3
    • /
    • pp.468-475
    • /
    • 2016
  • In this article, entropy generation on MHD Williamson nanofluid over a porous shrinking sheet has been analyzed. Nonlinear thermal radiation and chemical reaction effects are also taken into account with the help of energy and concentration equation. The fluid is electrically conducting by an external applied magnetic field while the induced magnetic field is assumed to be negligible due to small magnetic Reynolds number. The governing equations are first converted into the dimensionless expression with the help of similarity transformation variables. The solution of the highly nonlinear coupled ordinary differential equation has been obtained with the combination of Successive linearization method (SLM) and Chebyshev spectral collocation method. Influence of all the emerging parameters on entropy profile, temperature profile and concentration profile are plotted and discussed. Nusselt number and Sherwood number are also computed and analyzed. It is observed that entropy profile increases for all the physical parameters. Moreover, it is found that when the fluid depicts non-Newtonian (Williamson fluid) behavior then it causes reduction in the velocity of fluid, however, non-Newtonian behavior enhances the temperature and nanoparticle concentration profile.

Re-evaluation of Korean Effluent Concentration Limits and Comparative Analysis

  • Hwang, Won Tae;Lee, Joeun;Kwon, Dahye;Kim, Eun Han;Han, Moon Hee
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.3
    • /
    • pp.124-129
    • /
    • 2018
  • Background: Effluent Concentration Limits (ECLs) were re-evaluated via direct calculation using dose coefficients based on radiation protection quantity introduced in Korea and the intrinsic breathing rates of Korean residents. Materials and Methods: The re-evaluated ECLs were compared with the domestic standards given in the Notice of the Nuclear Safety and Security Commission (NSSC), as well as with ECLs specified in the Code of Federal Regulations (CFR). Results and Discussion: The relative ratios of the re-evaluated ECLs to the currently applied domestic standards differed depending on the radionuclide type, but it was clearly shown that, for tritium ($^3H$) and radiocarbon ($^{14}C$), which significantly affect radiological dose to the public during the normal operation of nuclear power plants, the re-evaluated ECLs were higher than the domestic standards. This implies that Korean standards are relatively conservative. Conclusion: The re-evaluated results for each age group showed that $^{131}I$ (radioiodine), one of the significant radionuclides, had the lowest values, but nonetheless, the domestic standards for radioiodine were lower than the ECLs given in the CFR and the re-evaluated ECLs via a method given in the CFR.