• Title/Summary/Keyword: radiation concentration

Search Result 1,018, Processing Time 0.023 seconds

Simulating the impact of iodine as a contrast substance to enhance radiation to the tumor in a brain x-rayphototherapy

  • M. Orabi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1671-1676
    • /
    • 2023
  • The influence of adding iodine as a contrast substance to elevate radiation in a tumor is studied using simulation techniques of Monte-Carlo. The study is carried on a brain cancer by adopting an unsophisticated head phantom. The ionizing radiation source is an external beam of x-rays with energy range of a few tens of keV. The expected radiation dose increment due to adding the iodine is investigated by comparing the radiation in the tumor after and before adding the iodine and calculating the ratio between the two doses. Several concentrations of the contrast substance are used to quantify its impact. The change of the dose increment with the source energy is also examined. It is found that the radiation elevation in the tumor tends to saturate with increasing the iodine concentration, and for the studied domain of energies (30 keV-100 keV), the radiation dose enhancement factors (RDEF) for the different iodine concentrations (1%-9%) show peaked curves, with the peak occurring between 60 keV and 70 keV. For the highest concentration studied, 9%, the peak value is almost 7.

Effect of Radiation Models on the Suppression Limits in Counterflow Methane/Air Diffusion Flames (대향류 메탄/공기 확산화염에서 복사모델이 소화한계에 미치는 영향)

  • Mun, Sun-Yeo;Cho, Jae-Ho;Hwang, Cheol-Hong;Oh, Chang Bo;Park, Won-Hee
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.20-28
    • /
    • 2014
  • Effect of radiation models on the suppression limits in counterflow $CH_4$/air diffusion flame was numerically investigated with fundamental experiments for the numerical validation. $N_2$ and $CO_2$ were considered as extinguishing agents. The differences in extinguishing concentration between OTM and SNB radiation models which have different accuracy levels were examined. As a result, there is no considerable difference in extinguishing concentration for the $N_2$ dilution as the radiation models with different accuracy levels were used. As the $CO_2$ having strong radiative effect was diluted in the low strain flames, however, the radiation model with high predictive accuracy such as SNB should be used. In particular, the $CO_2$ dilution in fuel stream leads to the significant difference in extinguishing concentration between OTM and SNB models. Therefore, it is necessary that the radiation model should be reasonably chosen with the consideration of numerical accuracy and computational time for the prediction of extinguishing concentration.

A Study on the Correlation between the Volume of Indoor Space and the Measured Concentration of Indoor Radon (실내 체적과 라돈 농도와의 상관관계 연구)

  • Kang, Sung-A;Han, Dong-Hyun;Kim, Chong-Yeal
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.97-104
    • /
    • 2007
  • The corelation between the indoor volume and the measured radon concentration has been analyzed by comparing the radon concentration and the indoor volume of apartment rooms in Jeonju City. We also measured the annual exposure dose based on the variation in indoor radon concentration over time. To do this, we took 8 larger rooms and 8 smaller rooms of apartment, respectively, as a sample. The average volume of the larger rooms and that of the smaller rooms were $31.59\;m^3$ and $16.82\;m^3$, respectively. The average radon concentration of the larger rooms and that of the smaller rooms turned out to be $71.73\;Bq/m^3$ and $108.51\;Eq/m^3$, respectively. indicating that indoor volume is in inverse proportion to the radon concentration, i.e., the bigger the ratio of the surface area/volume, the higher the indoor radon concentration. From the measurement of the variation in indoor radon concentration over time fur a single day, the average intraday radon concentration variation was found to be about $46.8\;Bq/m^3$. The highest level of concentration ($114.5\;Bq/m^3$) was measured between 8 and 10 AM and the lowest level of concentration ($67.7\;Bq/m^3$) between 2 and 4 PM. The annual exposure dose turned out to be in the range of 0.3 mSv/yr to 2.16 mSv/yr, showing that the dose in some apartments exceeded 1.3 mSv/yr, the numerical value presented by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR).

Antibacterial Effect of PVP/PEG/Carrageenan/Silver Acetate Hydrogels by γ-ray (γ-ray를 이용하여 합성한 PVP/PEG/Carrageenan/Silver acetate 하이드로겔의 항균효과)

  • Lim, Youn-Mook;Youn, Young;Gwon, Hui-Jeong;Park, Jong-Seok;Nho, Young-Chang
    • Journal of Radiation Industry
    • /
    • v.4 no.1
    • /
    • pp.73-77
    • /
    • 2010
  • In recent day, there is much interest in the biocidal activity of silver since silver is known to be safe and effective as disinifectant and biocidal material against coliforms and viruses. In this study, hydrogels containing silver acetate as antibacterial agent have been prepared using gamma rays irradiation. The hydrogels are composed of poly(vinyl pyrrolidone) (PVP), poly(ethylene glycol) (PEG), carrageenan and silver acetate. The concentration of solution was 9 wt%. The ratio of PVP : PEG : carrageenan was 6 : 1 : 2. The concentration of the silver acetate were 0, 0.01, 0.03, 0.05 and 0.07% and Gamma irradiation dose was 25 kGy. The Gamma irradiation dose in hydrogels with 0.01% silver acetate were 20 kGy, 35 kGy, 50 kGy, 65 kGy, and 80 kGy. The results showed that 0.01% silver acetate concentration of hydrogels by 25 kGy irradiation dose showed the highest antibacterial activity against E. coli and Staphylococcus aureus. Moreover, antibacterial activity of various Gamma irradiation dose in hydrogels treated 0.01% silver acetate showed highest 35 kGy irradiation dose against Staphylococcus aureus.

N-Nitrosodimethylamine Concentrations in Domestic and Imported Beer in Korea

  • Ahn, Hyun-Joo;Kim, Jae-Hyun;Cheorun Jo;Kim, Myung-Chul;Hong, Jin-Hwan;Byun, Myung-Woo
    • Preventive Nutrition and Food Science
    • /
    • v.7 no.2
    • /
    • pp.219-221
    • /
    • 2002
  • N-Nitrosodimethylamine (NDMA) was determined in both domestic Korean and imported beers, from the Netherlands, USA, Japan, Belgium and Germany. Among the 8 kinds of Korean beers, 4 were contaminated with NDMA, and 4 were not. The average concentration of NDMA detected in Korean beers was 0.78 $\mu\textrm{g}$/kg and the maximum NDMA concentration was 5.73 $\mu\textrm{g}$/kg. NDMA was only detected in one imported beer, which had a concentration of 5.29 $\mu\textrm{g}$/kg. Assuming an average concentration of 0.78 $\mu\textrm{g}$/kg NDMA in Korean domestic beer, the average daily intake of NDMA through domestic beer consumption by a typical Korean is approximately 0.58 $\mu\textrm{g}$/person/day.

Preparation and Characterization of Polyvinylpyrrolidone/${\kappa}$-Carrageenan/Hexanediol Hydrogel by Gamma-ray Irradiation (감마선을 이용한 폴리비닐피롤리돈/카파-카라기난/1,2-헥산디올 하이드로젤의 제조 및 특성)

  • Han, Il-Soo;Lim, Youn-Mook;Gwon, Hui-Jeong;Park, Jong-Seok;Nho, Young-Chang
    • Polymer(Korea)
    • /
    • v.35 no.1
    • /
    • pp.13-16
    • /
    • 2011
  • In this study, the hydrogels composed of polyvinylpyrrolidone (PVP), ${\kappa}$-carrageenan (${\kappa}C$), and 1,2-hexanediol (HD) were prepared by ${\gamma}$-ray irradiation. The radiation dose was 25 kGy and the concentration of ${\kappa}C$ was 3 wt%. The physical properties of the hydrogels were investigated as a function of the concentrations of PVP and HD. The gel content and the tensile strength increased with increasing PVP concentration due to the crosslinking between the pyrrolidone molecules and decreased with increasing HD concentration. The degree of swelling was inversely proportional to the gel content because the highly crosslinked hydrogels had a tighter structure, hence reducing their water absorption. The antibacterial tests indicated that the hydrogels containing HD had antibacterial activity.

Effect of Salt Concentration on the Quality of SaewooJeot(Salted Shrimp) Fermented at Room Temperature (실온 저장 새우젓의 이화학적 미생물학적 특성에 미치는 염농도의 영향)

  • Oh Sang-Hee;Heo Ok-Soon;Shin Hyun-Soo;Lee Ju-Woon;Kim Dong-Ho;Byun Myung-Woo;Kim Mee-Ree
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.15 no.4
    • /
    • pp.444-449
    • /
    • 2005
  • Effect of salt concentration on the quality of Saewoojeot (salted shrimp) fermented at room temperature was evaluated Salted shrimp with three different salt concentration (9, 18 and $27\%$) were prepared with fresh shrimp, and fermented at $20^{\circ}C$ temperatures for 180 days. Amino nitrogen (AN), volatile basic nitrogen (VBN) and trimethylamine (TMA) contents increased with longer fermentation time and lower salt concentration. AN, VBN and TMA contents in salted and fermented shrimp with $9\%$ salt increased rapidly during fermentation period, while that with 18 and $27\%$ salt maintained its initial level through 180 days of fermentation. When salted and fermented shrimps were fermented at $20^{\circ}C$, all the indexes of fermentation process maintained stable with $27\%$ salt level. Pathogenic bacteria such as pathogenic Echerichia coli, Salmonella spp., were not detected in the manufactured salted and fermented shrimps. However, coliform and yeast disappeared within 180 days and 100 days of storage for 18 and $27\%$ salt, respectively. Gram positive cocci survived until 180 days of storage against $18\%$($10^3-10^6$ CFU/g) and $27\%$($0-10^6$ CFU/g) salt.

  • PDF

An Internal Tritium Concentration Analysis in Urine Samples as a Function of Submission Time after Airborne Tritium Intake at Korean Pressurized Heavy Water Reactors (중수로원전 방사선작업종사자의 공기중 삼중수소 섭취 후 뇨시료 제출 시간이 체내 삼중수소 농도에 미치는 영향 분석)

  • Kim, Hee-Geun;Kong, Tae-Young;Jeong, Woo-Tae;Kim, Seok-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.184-189
    • /
    • 2009
  • In pressurized heavy water reactors, workers who enter radiation controlled areas must submit their urine samples to health physicists after radiation work; these samples are then used to monitor internal radiation exposure from tritium intake. This procedure assumes that the samples submitted represent tritium concentration inside the body at equilibrium. According to both technical reports from the International Commission on Radiological Protection and experimental results from Canadian nuclear utilities, tritium inside the body generally reaches equilibrium concentration after approximately 2-3 hours of intake. In practice, urine samples can be submitted either before the 2 hours mark or after several hours of radiation work because of the numerous tasks that workers must perform and their frequent entries during nuclear power plant maintenance. In this paper, tritium concentration in workers' urine samples was measured as a function of time submitted after radiation work. Based on the measurement results, changes in the tritium concentration inside the body and its effect on internal dose assessment were then analyzed. As a result, it was found that tritium concentration reaches equilibrium concentration before the 2 hours mark for most workers' urine samples.

Relationship Between Ozone Concentrations and Affecting factors in Seosan City of Korea (충남 서산지역 대기 중의 오존농도와 그 영향인자와의 관련성)

  • Kim, Jun-Kyeom;Jeong, Yong-Jun;Cho, Young-Chae
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.78-88
    • /
    • 2003
  • This study was conducted to investigate the relation between ozone concentration and the affecting factors in Seosan City of Korea from Jan. 2002 to Dec. 2002. We analyzed the air pollutants such as NO$_2$, PM$_{10} $,SO$_2$, CO and the meteorological factors including solar radiation, air temperature, wind speed and relative humidity. The analytical data were taken statistics by SPSS method. The results were as follows: The seasonal average concentration of ozone were detected 35.0 ppb in Spring, 25.4 ppb in Summer, 23.5 ppb in Autumn and 21.4 ppb in Winter. So the difference of concentrations showed significantly in statistics. The hourly ozone concentration in a day was increased at 7-9 AM, peaked at 3-4 PM. The correlation coefficients was negative to ozone concentration and NO$_2$, SO$_2$, CO, relative humidity, but positive to solar radiation, air temperature, wind speed. With stepwise multiple regression analysis on the 8 factors such as NO$ _2$, PMSO$_{10}$,SO$_2$, CO, solar radiation, air temperature, wind speed and relative humidity, the seasonal primary factors were air temperature in spring, relative humidity in summer and solar radiation in autumn and winter. The above results suggest that ozone is the secondary pollutant by photochemical reaction as the concentration of ozone was increased with the raise of solar radiation.

Decomposition of Antibiotics (Cefaclor) by Ionizing Radiation: Optimization and Modeling Using a Design of Experiment (DOE) Based on Statistical Analysis

  • Yu, Seung-Ho;Chang, Soon-Woong;Lee, Si-Jin;Cho, Il-Hyoung
    • Environmental Engineering Research
    • /
    • v.14 no.2
    • /
    • pp.81-87
    • /
    • 2009
  • The decomposition of antibiotics (cefaclor) by gamma irradiation in aqueous solutions was experimentally evaluated. To obtain a mutual interaction between two factors (antibiotics concentrations and radiation doses) and to optimize these factors during the process, experimental design and statistical analysis were employed. The decomposition capability of the gamma radiation was also mathematically described as a function of cefaclor concentration and gamma-ray dose using the statistical analysis. The results showed that the cefaclor concentration ($X_1$) in the response $Y_1$ (Reduction of cefaclor concentration) and gamma-ray dose ($X_2$) in the response $Y_2$ (Removal efficiency (%) of cefaclor concentration) exhibited a significantly positive effect, whereas gamma-ray dose ($X_2$) in the response $Y_1$ showed a significantly negative effect. The estimated ridge of maximum responses and optimal conditions for $Y_1$:($X_1$,$X_2$)=(25 mg/L, 350 Gy) and $Y_2$:($X_1$,$X_2$)=(21 mg/L, 565 Gy) using canonical analysis were 4.37 mg/L of reduction of cefaclor concentration and 98.35% of removal efficiency of cefaclor concentration, respectively. The measurement values agreed well with the predicted ones, thereby confirming the suitability of the model for $Y_1$ and $Y_2$ and the success of the experimental design in optimizing the conditions of the gamma irradiation process.