• Title/Summary/Keyword: radiation accident

Search Result 308, Processing Time 0.021 seconds

DEVELOPMENT OF MARS-GCR/V1 FOR THERMAL-HYDRAULIC SAFETY ANALYSIS OF GAS-COOLED REACTOR SYSTEMS

  • LEE WON-JAE;JEONG JAR-JUN;LEE SEUNG-WOOK;CHANG JONGHWA
    • Nuclear Engineering and Technology
    • /
    • v.37 no.6
    • /
    • pp.587-594
    • /
    • 2005
  • In an effort to develop a thermal-hydraulic (TH) safety analysis code for Gas-cooled Reactors (GCRs), the MARS code, which was primarily developed for TH analysis of water reactor systems, has been extended here for application to GCRs. The modeling requirements of the system code were derived from a review of major processes and phenomena that are expected to occur during normal and accident conditions of GCRs. Models fur code improvement were then identified through a review of existing MARS code capability. Among these, the following priority models necessary fur the analysis of limiting high and low pressure conduction cooling events were evaluated and incorporated in MARS-GCR/V1 : 1) Helium (He) and Carbon Dioxide ($CO_2$) as main system fluids, 2) gas convection heat transfer, 3) radiation heat transfer, and 4) contact heat transfer models. Each model has been assessed using various conceptual problems for code-to-code benchmarks and it was demonstrated that MARS-GCR/V1 is capable of capturing the relevant phenomena. This paper describes the models implemented in MARS-GCR/V1 and their verification and validation results.

In-situ Blockage Monitoring of Sensing Line

  • Mangi, Aijaz Ahmed;Shahid, Syed Salman;Mirza, Sikander Hayat
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.98-113
    • /
    • 2016
  • A reactor vessel level monitoring system measures the water level in a reactor during normal operation and abnormal conditions. A drop in the water level can expose nuclear fuel, which may lead to fuel meltdown and radiation spread in accident conditions. A level monitoring system mainly consists of a sensing line and pressure transmitter. Over a period of time boron sediments or other impurities can clog the line which may degrade the accuracy of the monitoring system. The aim of this study is to determine blockage in a sensing line using the energy of the composite signal. An equivalent Pi circuit model is used to simulate blockages in the sensing line and the system's response is examined under different blockage levels. Composite signals obtained from the model and plant's unblocked and blocked channels are decomposed into six levels of details and approximations using a wavelet filter bank. The percentage of energy is calculated at each level for approximations. It is observed that the percentage of energy reduces as the blockage level in the sensing line increases. The results of the model and operational data are well correlated. Thus, in our opinion variation in the energy levels of approximations can be used as an index to determine the presence and degree of blockage in a sensing line.

The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition (일체형 주상용 몰드변압기의 덕트에 따른 열해석 특성 연구)

  • Cho, Han-Goo;Lee, Un-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1135-1138
    • /
    • 2003
  • The transformer is major equipment in power receiving and substation facilities. Necessary conditions required for the transformer are compactness, lightness, high reliability, economic advantages, and easy maintenance. The pole-mount transformer installed in distribution system is acting direct role in supply of electric power and it is electric power device should drive for long term. Most of modem transformer are oil-filled transformer and accident is happening considerable. The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. One body molding transformer needs some cooling method because heat radiation between each winding is difficult. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

  • PDF

PRELIMINARY SAFETY STUDY OF ENGINEERING-SCALE PYROPROCESS FACILITY

  • Moon, Seong-In;Chong, Won-Myung;You, Gil-Sung;Ku, Jeong-Hoe;Kim, Ho-Dong;Lim, Yong-Kyu;Chang, Hyeon-Sik
    • Nuclear Engineering and Technology
    • /
    • v.46 no.1
    • /
    • pp.63-72
    • /
    • 2014
  • Pyroprocess technology has been considered as a fuel cycle option to solve the spent fuel accumulation problems in Korea. The Korea Atomic Energy Research Institute has been studying pyroprocess technology, and the conceptual design of an engineering-scale pyroprocess facility, called the Advanced Fuel Cycle (AFC) facility, has been performed on the basis of a 10tHM throughput per year. In this paper, the concept of the AFC facility was introduced, and its safety evaluations were performed. For the safety evaluations, anticipated accident events were selected, and environmental safety analyses were conducted for the safety of the public and workers. In addition, basic radiation shielding safety analyses and criticality safety analyses were conducted. These preliminary safety studies will be used to specify the concept of safety systems for pyroprocess facilities, and to establish safety design policies and advance more definite safety designs.

Deep Learning(CNN) based Worker Detection on Infrared Radiation Image Analysis (딥러닝(CNN)기반 저해상도 IR이미지 분석을 통한 작업자 인식)

  • Oh, Wonsik;Lee, Ugwiyeon;Oh, Jeongseok
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.8-15
    • /
    • 2018
  • worker-centered safety management for hazardous areas in the plant is required. The causes of gas accidents in the past five years are closely related to the behavior of the operator, such as careless handling of the user, careless handling of the suppliers, and intentional, as well as equipment failure and accident of thought. In order to prevent such accidents, real-time monitoring of hazardous areas in the plant is required. However, when installing a camera in a work space for real-time monitoring, problems such as human rights abuse occur. In order to prevent this, an infrared camera with low resolution with low exposure of the operator is used. In real-time monitoring, image analysis is performed using CNN algorithm, not human, to prevent human rights violation.

A flammability limit model for hydrogen-air-diluent mixtures based on heat transfer characteristics in flame propagation

  • Jeon, Joongoo;Choi, Wonjun;Kim, Sung Joong
    • Nuclear Engineering and Technology
    • /
    • v.51 no.7
    • /
    • pp.1749-1757
    • /
    • 2019
  • Predicting lower flammability limits (LFL) of hydrogen has become an ever-important task for safety of nuclear industry. While numerous experimental studies have been conducted, LFL results applicable for the harsh environment are still lack of information. Our aim is to develop a calculated non-adiabatic flame temperature (CNAFT) model to better predict LFL of hydrogen mixtures in nuclear power plant. The developed model is unique for incorporating radiative heat loss during flame propagation using the CNAFT coefficient derived through previous studies of flame propagation. Our new model is more consistent with the experimental results for various mixtures compared to the previous model, which relied on calculated adiabatic flame temperature (CAFT) to predict the LFL without any consideration of heat loss. Limitation of the previous model could be explained clearly based on the CNAFT coefficient magnitude. The prediction accuracy for hydrogen mixtures at elevated initial temperatures and high helium content was improved substantially. The model reliability was confirmed for $H_2-air$ mixtures up to $300^{\circ}C$ and $H_2-air-He$ mixtures up to 50 vol % helium concentration. Therefore, the CNAFT model developed based on radiation heat loss is expected as the practical method for predicting LFL in hydrogen risk analysis.

Preliminary Evaluation of Radiological Impact for Domestic On-road Transportation of Decommissioning Waste of Kori Unit 1

  • Dho, Ho-Seog;Seo, Myung-Hwan;Kim, Rin-Ah;Kim, Tae-Man;Cho, Chun-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.4
    • /
    • pp.537-548
    • /
    • 2020
  • Currently, radioactive waste for disposal has been restricted to low and intermediate level radioactive waste generated during operation of nuclear power plants, and these radioactive wastes were managed and disposed of the 200 L and 320 L of steel drums. However, it is expected that it will be difficult to manage a large amount of decommissioning waste of the Kori unit 1 with the existing drums and transportation containers. Accordingly, the KORAD is currently developing various and large-sized containers for packaging, transportation, and disposal of decommissioning waste. In this study, the radiation exposure doses of workers and the public were evaluated using RADTRAN computational analysis code in case of the domestic on-road transportation of new package and transportation containers under development. The results were compared with the domestic annual dose limit. In addition, the sensitivity of the expected exposure dose according to the change in the leakage rate of radionuclides in the waste packaging was evaluated. As a result of the evaluation, it was confirmed that the exposure dose under normal and accident condition was less than the domestic annual exposure dose limit. However, in the case of a number of loading and unloading operations, working systems should be prepared to reduce the exposure of workers.

Application of two different similarity laws for the RVACS design

  • Min Ho Lee;Ji Hwan Hwang;Ki Hyun Choi;Dong Wook Jerng;In Cheol Bang
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4759-4775
    • /
    • 2022
  • The RVACS is a versatile and robust safety system driven by two natural circulations: in-vessel coolant and ex-vessel air. To observe interaction between the two natural circulations, SINCRO-IT facility was designed with two different similarity laws simultaneously. Bo' based similarity law was employed for the in-vessel, while Ishii's similarity law for the ex-vessel excluding the radiation. Compared to the prototype, the sodium and air system, SINCRO-IT was designed with Wood's metal and air, having 1:4 of the length reduction, and 1.68:1 of the time scale ratio. For the steady state, RV temperature limit was violated at 0.8% of the decay heat, while the sodium boiling was predicted at 1.3%. It showed good accordance with the system code, TRACE. For an arbitrary re-criticality scenario with RVACS solitary operation, sodium boiling was predicted at 25,100 s after power increase from 1.0 to 2.0%, while the system code showed 30,300. Maximum temperature discrepancy between the experiments and system code was 4.2%. The design and methodology were validated by the system code TRACE in terms of the convection, and simultaneously, the system code was validated against the simulating experiments SINCRO-IT. The validated RVACS model could be imported to further accident analysis.

Preliminary Shielding Analysis of the Concrete Cask for Spent Nuclear Fuel Under Dry Storage Conditions (건식저장조건의 사용후핵연료 콘크리트 저장용기 예비 방사선 차폐 평가)

  • Kim, Tae-Man;Dho, Ho-Seog;Cho, Chun-Hyung;Ko, Jae-Hun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.4
    • /
    • pp.391-402
    • /
    • 2017
  • The Korea Radioactive Waste Agency (KORAD) has developed a concrete cask for the dry storage of spent nuclear fuel that has been generated by domestic light-water reactors. During long-term storage of spent nuclear fuel in concrete casks kept in dry conditions, the integrity of the concrete cask and spent nuclear fuel must be maintained. In addition, the radiation dose rate must not exceed the storage facility's design standards. A suitable shielding design for radiation protection must be in place for the dry storage facilities of spent nuclear fuel under normal and accident conditions. Evaluation results show that the appropriate distance to the annual dose rate of 0.25 mSv for ordinary citizens is approximately 230 m. For a $2{\times}10$ arrangement within storage facilities, rollover accidents are assumed to have occurred while transferring one additional storage cask, with the bottom of the cask facing the controlled area boundary. The dose rates of 12.81 and 1.28 mSv were calculated at 100 m and 230 m from the outermost cask in the $2{\times}10$ arrangement. Therefore, a spent nuclear fuel concrete cask and storage facilities maintain radiological safety if the distance to the appropriately assessed controlled area boundary is ensured. In the future, the results of this study will be useful for the design and operation of nuclear power plant on-site storage or intermediate storage facilities based on the spent fuel management strategy.

Reduction of Outdoor and Indoor Ambient Dose Equivalent after Decontamination in the Fukushima Evacuation Zones

  • Yoshida-Ohuchi, Hiroko;Kanagami, Takashi;Naitoh, Yutaka;Kameyama, Mizuki;Hosoda, Masahiro
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.1
    • /
    • pp.42-47
    • /
    • 2017
  • Background: One of the most urgent issues following the accident at the Fukushima Daiichi nuclear power plant (FDNPP) was the remediation of the land, in particular, for residential area contaminated by the radioactive materials discharged. In this study, the effect of decontamination on reduction of ambient dose equivalent outdoors and indoors was evaluated. The latter is essential for residents as most individuals spend a large portion of their time indoors. Materials and Methods: From December 2012 to November 2014, thirty-seven Japanese single-family detached wooden houses were investigated before and after decontamination in evacuation zones. Outdoor and indoor dose measurements (n = 84 and 114, respectively) were collected based on in situ measurements using the NaI (Tl) scintillation surveymeter. Results and Discussion: The outdoor ambient dose equivalents [$H^*(10)_{out}$] ranged from 0.61 to $3.71{\mu}Sv\;h^{-1}$ and from 0.23 to $1.32{\mu}Sv\;h^{-1}$ before and after decontamination, respectively. The indoor ambient dose equivalents [$H^*(10)_{in}$] ranged from 0.29 to $2.53{\mu}Sv\;h^{-1}$ and from 0.16 to $1.22{\mu}Sv\;h^{-1}$ before and after decontamination, respectively. The values of reduction efficiency (RE), defined as the ratio by which the radiation dose has been reduced via decontamination, were evaluated as $0.47{\pm}0.13$, $0.51{\pm}0.13$, and $0.58{\pm}0.08$ ($average{\pm}{\sigma}$) when $H^*(10)_{out}$ < $1.0{\mu}Sv\;h^{-1}$, $1.0{\mu}Sv\;h^{-1}$ < $H^*(10)_{out}$ < $2.0{\mu}Sv\;h^{-1}$, and $2.0{\mu}Sv\;h^{-1}$ < $H^*(10)_{out}$, respectively, indicating the values of RE increased as $H^*(10)_{out}$ increased. It was found that the values of RE were $0.53{\pm}0.12$ outdoors and $0.41{\pm}0.09$ indoors, respectively, indicating RE was larger outdoors than indoors. Conclusion: Indoor dose is essential as most individuals spend a large portion of their time indoors. The difference between outdoors and indoors should be considered carefully in order to estimate residents' exposure dose before their returning home.