• Title/Summary/Keyword: radiation

Search Result 19,449, Processing Time 0.043 seconds

Some Measurements of Scattered Radiation from Various Radiation Shielding Materials (방사선(放射線) 차폐물질(遮蔽物質)에서 발생(發生)하는 산란선(散亂線)의 측정(測定))

  • Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.4 no.1
    • /
    • pp.15-22
    • /
    • 1981
  • Half value layer(radiation energy) of $90^{\circ}$ scattered radiation from various radiation shielding materials was measured at 1 m distance from the central ray of the primary beam. Scattered radiation was measured from 100 to 200 kVp for 0-2.0mm Cu+1.0mm Al added filter in the primary beam for a deep therapeutic unit, the obtained results were as follows: 1. The ratio of scattered radiation to primary radiation was increased by using lighter filter. 2. The ratio of scattered radiation to primary radiation was decreased by using heavier filter. 3. The ratio of scattered radiation to primary radiation was independent of tube voltage. 4. The scattered radiation of high energy was produced, when the effective atomic number and density of shielding material were high.

  • PDF

The Radiation Resistance Evaluation of Electrically Insulating Polymers

  • Lee, Dong-Hoon;Jung, Chan-Hee;Hwang, In-Tae;Choi, Jae-Hak;Im, Don-Sun;Kim, Ki-Yup;Nho, Young-Chang
    • Journal of Radiation Industry
    • /
    • v.5 no.3
    • /
    • pp.237-242
    • /
    • 2011
  • In this research, the radiation resistance of ethylene propylene rubber (EPR) and chlorosulfonated polyethylene (CSPE) which can be used as a insulating materials of for electrical cable in the nuclear power plant were investigated. EPR and CSPE were irradiated by ${\gamma}$-ray at various doses ranging from 50 to 500 kGy at room temperature in air. The irradiated EPR and CSPE was investigated in terms of activation energy, mechanical properties, and oxidation stability. The experimental results revealed that CSPE exhibited the higher radiation resistance in comparison to that of EPR.

Simple Calculation Method as a Supplementary Radiation Safety Assessment for Facility with Radiation Generator

  • Kim, Sang-Tae
    • International Journal of Contents
    • /
    • v.14 no.4
    • /
    • pp.65-69
    • /
    • 2018
  • The objective of this study was to conduct a radiation shielding analysis for the facility equipped with radiation generator. The analysis was carried out in two aspects. First, from the aspect of the effect caused by primary and leakage radiation. Second, effect of scattered radiation was evaluated by applying a simple calculation method based on a scattering rate concept since effect of scattered radiation is significantly important at maze entrance of the radiation facility. The calculated results obtained using the simple method were compared to the results calculated using Geant4 code and the measured values. The results calculated by the suggested method indicate that slight error exists in a radiation shielding analysis done at the maze entrance comparing to other two results, while the results evaluated at the outside of the maze entrance door are relatively consistent with other values.

The Necessity and Development of Radiation Counsellor Qualifications System (방사선카운슬러 자격제도의 필요성과 발전방안)

  • Kweon, Dae Cheol;Choi, Jiwon
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.373-377
    • /
    • 2018
  • The purpose of this study is to suggest a necessity and development of radiation counsellor qualifications system for the public to solve the anxiety and the curiosity about radiation exposure. We analyzed the definition and role of radiation counsellor and define radiation counsellor qualifications system. Qualification is given to those who have completed the professional training course organized by Korea Energy Information Culture Agency (KEIA). Since 2014, KEIA has been conducting radiation counsellor training, Examination and certification. This system continues to promote efforts to disseminate and develop the right knowledge about radiation risk and information of radiation risk to the public. Also, it is thought that radiation counsellors could be able to fulfill the roles needed in society through legislation for the mandatory placement of radiation counsellors.

Effects of ${\gamma}$-Irradiation on Immunological Activities of ${\beta}$-Glucan

  • Kim, Jae-Hun;Sung, Nak-Yun;Byun, Eui-Hong;Kwon, Sun-Kyu;Song, Beom-Seok;Choi, Jong-Il;Yoon, Yohan;Kim, Jin-Kyu;Byun, Myung-Woo;Lee, Ju-Woon
    • Food Science and Biotechnology
    • /
    • v.18 no.5
    • /
    • pp.1305-1309
    • /
    • 2009
  • This study evaluated the effects of $\gamma$-irradiation on immunomodulating properties and structural changes of ${\beta}$-glucan. ${\beta}$-Glucan solutions (10 mg/mL) were ${\gamma}$-irradiated at 10, 30, and 50 kGy. Splenocyte proliferation and cytokine (interferon-${\gamma}$ and interlukin-2) productions by ${\gamma}$-irradiated ${\beta}$-glucan were evaluated in in vivo and in vitro, and structural changes of ${\beta}$-glucan were also determined after ${\gamma}$-irradiation. ${\gamma}$-Irradiation on ${\beta}$-glucan at 50 kGy enhanced splenocyte proliferation and cytokine productions, (p<0.05) and cleft glycosidic bonds of ${\beta}$-glucan resulting in lower the molecular weight. These results indicate that the use of ${\gamma}$-irradiation on ${\beta}$-glucan may be useful for improving its immunological activity by lowering the molecular weight of ${\beta}$-glucan.

Factors predicting radiation pneumonitis in locally advanced non-small cell lung cancer

  • Kim, Myung-Soo;Lee, Ji-Hae;Ha, Bo-Ram;Lee, Re-Na;Lee, Kyung-Ja;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.29 no.3
    • /
    • pp.181-190
    • /
    • 2011
  • Purpose: Thoracic radiotherapy is a major treatment modality of stage III non-small cell lung cancer. The normal lung tissue is sensitive to radiation and radiation pneumonitis is the most important dose-limiting complication of thoracic radiation therapy. This study was performed to identify the clinical and dosimetric parameters related to the risk of radiation pneumonitis after definitive radiotherapy in stage III non-small cell cancer patients. Materials and Methods: The medical records were reviewed for 49 patients who completed definitive radiation therapy for locally advanced non-small cell lung cancer from August 2000 to February 2010. Radiation therapy was delivered with the daily dose of 1.8 Gy to 2.0 Gy and the total radiation dose ranged from 50.0 Gy to 70.2 Gy (median, 61.2 Gy). Elective nodal irradiation was delivered at a dose of 45.0 Gy to 50.0 Gy. Seven patients (14.3%) were treated with radiation therapy alone and forty two patients (85.7%) were treated with chemotherapy either sequentially or concurrently. Results: Twenty-five cases (51.0%) out of 49 cases experienced radiation pneumonitis. According to the radiation pneumonitis grade, 10 (20.4%) were grade 1, 9 (18.4%) were grade 2, 4 (8.2%) were grade 3, and 2 (4.1%) were grade 4. In the univariate analyses, no clinical factors including age, sex, performance status, smoking history, underlying lung disease, tumor location, total radiation dose and chemotherapy were associated with grade ${\geq}2$ radiation pneumonitis. In the subgroup analysis of the chemotherapy group, concurrent rather than sequential chemotherapy was significantly related to grade ${\geq}2$ radiation pneumonitis comparing sequential chemotherapy. In the univariate analysis with dosimetric factors, mean lung dose (MLD), $V_{20}$, $V_{30}$, $V_{40}$, MLDipsi, $V_{20}$ipsi, $V_{30}$ipsi, and $V_{40}$ipsi were associated with grade ${\geq}2$ radiation pneumonitis. In addition, multivariate analysis showed that MLD and V30 were independent predicting factors for grade ${\geq}2$ radiation pneumonitis. Conclusion: Concurrent chemotherapy, MLD and $V_{30}$ were statistically significant predictors of grade ${\geq}2$ radiation pneumonitis in patients with stage III non-small cell lung cancer undergoing definitive radiotherapy. The cutoff values for MLD and $V_{30}$ were 16 Gy and 18%, respectively.

Knowledge of Radiation Protection and the Recognition and Performance of Radiation Protection Behavior among Perioperative Nurses (수술실 간호사의 방사선 방어에 대한 지식과 방사선 방어행위에 대한 인식도 및 수행도)

  • Kang, Sung Gum;Lee, Eun Nam
    • Journal of muscle and joint health
    • /
    • v.20 no.3
    • /
    • pp.247-257
    • /
    • 2013
  • Purpose: The purpose of this descriptive study was to investigate the knowledge of radiation protection and the recognition and performance of radiation protection behaviors among perioperative nurses. This study was intended to yield basic data for the development of nursing interventions aimed at improving the nurses' radiation protection behaviors. Methods: One hundred and thirty-seven nurses working in the operating room participated in a survey from September 1 to 30, 2011. The data was analyzed using t-test, ANOVA, and Pearson's correlation with the SPSS/WIN 19.0 program. Results: The average score of radiation protection knowledge was $7.57{\pm}3.45$ out of 16. The average score for the recognition and performance of radiation protection behaviors was $4.32{\pm}0.23$. The knowledge of radiation protection was significantly correlated with the recognition and performance of radiation protection behaviors. Conclusion: Expanding the knowledge of radiation protection could lead to the increase of the recognition and performance of radiation protection behaviors. Therefore, promoting the performance of radiation protection behaviors by improving perioperative nurses' knowledge of radiation protection through reinforcing radiation-related education hereafter could be an important part of nursing.

Possible Biomarker Gene for Radiation Workers in Hospital

  • Jin, Young-Woo;Jeong, Mee-Seon;Moon, Kien;Lee, Chee-Young;Bae, Sang-Woo;Choi, Soo-Yong;Lee, Yun-Sil
    • Molecular & Cellular Toxicology
    • /
    • v.5 no.2
    • /
    • pp.165-171
    • /
    • 2009
  • Biomarkers indicating past exposure to radiation have not yet been entirely satisfactory. In this study, we validated several genes reported as radiation response genes, as biomarkers to detect past exposure to radiation in occupationally exposed workers, especially workers in the medical field. A total of 54 radiation workers in hospital were investigated for radiation exposure dose. Their average radiation dose of recent one year was 1.09 mSv ($\pm$1.63) with a 10.63 mSv ($\pm$12.91) cumulative dose. The results of the multiple regression analysis for the various variables indicate that the Hsc70 (P=0.0292) and ORAL (P=0.0045) may be candidate biomarkers for the recent 1 year radiation exposure in radiation workers, whereas AEN (P=0.0334) and PGAMI (P=0.0003) might be for cumulative exposure.

System Software Design of Computerized Tomography Radiation Dose Management (컴퓨터 단층촬영 방사선 노출 관리 시스템 소프트웨어 설계)

  • Yang, Yu Mi;Cho, Sang Wook;Lee, Kil Hung
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.3
    • /
    • pp.41-48
    • /
    • 2014
  • This paper provides the design of system software for the management of radiation dose that is generated by using computerized tomography(CT). Recently, the radiation leakage incident of Japanese nuclear power plant was in the news internationally and there is a growing interest not only in nuclear power plant but in medical radiation exposure. In spite of the fact that currently safety management of radiation is under control only the workers of the radiation involved, now the exposure management of patients have been required. As surgery and inspections using the radiation have increased, this medical radiation exposure is increasing too. But it is a real situation that medical institutions don't know the level of radiation exposure applied to the patient. Therefore, a system for managing the radiation exposure of a patient from the medical institution is required. This paper proposes a design of a software program that manages the radiation exposure of CT which is a typical imaging tool to use the radiation in the medical institution. By check the amount of radiation dose and set the limit of dose, we would be of help to optimize the medical exposure of the patient.