• 제목/요약/키워드: radiation

Search Result 19,470, Processing Time 0.047 seconds

Impact by Estimation Error of Hourly Horizontal Global Solar Radiation Models on Building Energy Performance Analysis on Building Energy Performance Analysis

  • Kim, Kee Han;Oh, John Kie-Whan
    • KIEAE Journal
    • /
    • v.14 no.2
    • /
    • pp.3-10
    • /
    • 2014
  • Impact by estimation error of hourly horizontal global solar radiation in a weather file on building energy performance was investigated in this study. There are a number of weather parameters in a given weather file, such as dry-bulb, wet-bulb, dew-point temperatures; wind speed and direction; station pressure; and solar radiation. Most of them except for solar radiation can be easily obtained from weather stations located on the sites worldwide. However, most weather stations, also including the ones in South Korea, do not measure solar radiation because the measuring equipment for solar radiation is expensive and difficult to maintain. For this reason, many researchers have studied solar radiation estimation models and suggested to apply them to predict solar radiation for different weather stations in South Korea, where the solar radiation is not measured. However, only a few studies have been conducted to identify the impact caused by estimation errors of various solar radiation models on building energy performance analysis. Therefore, four different weather files using different horizontal global solar radiation data, one using measured global solar radiation, and the other three using estimated global solar radiation models, which are Cloud-cover Radiation Model (CRM), Zhang and Huang Model (ZHM), and Meteorological Radiation Model (MRM) were packed into TRY formatted weather files in this study. These were then used for office building energy simulations to compare their energy consumptions, and the results showed that there were differences in the energy consumptions due to these four different solar radiation data. Additionally, it was found that using hourly solar radiation from the estimation models, which had a similar hourly tendency with the hourly measured solar radiation, was the most important key for precise building energy simulation analysis rather than using the solar models that had the best of the monthly or yearly statistical indices.

Radiation Safety and Education in the Applicants of the Final Test for the Expert of Pain Medicine

  • Park, Pyong-Eun;Park, Jung-Min;Kang, Joo-Eun;Cho, Jae-Hun;Cho, Suk-Ju;Kim, Jae-Hun;Sim, Woo-Seog;Kim, Yong-Chul
    • The Korean Journal of Pain
    • /
    • v.25 no.1
    • /
    • pp.16-21
    • /
    • 2012
  • Background: The C-arm fluoroscope is known as the most important equipment in pain interventions. This study was conducted to investigate the completion rate of education on radiation safety, the knowledge of radiation exposure, the use of radiation protection, and so on. Methods: Unsigned questionnaires were collected from the 27 pain physicians who applied for the final test to become an expert in pain medicine in 2011. The survey was composed of 12 questions about the position of the hospital, the kind of hospital, the use of C-arm fluoroscopy, radiation safety education, knowledge of annual permissible radiation dose, use of radiation protection, and efforts to reduce radiation exposure. Results: In this study, although most respondents (93%) had used C-arm fluoroscopy, only 33% of the physicians completed radiation safety education. Even though nine (33%) had received education on radiation safety, none of the physicians knew the annual permissible radiation dose. In comparing the radiation safety education group and the no-education group, the rate of wearing radiation-protective glasses or goggles and the use of radiation badges or dosimeters were significantly higher in the education group. However, in the use of other protective equipment, knowledge of radiation safety, and efforts to reduce radiation exposure, there were no statistical differences between the two groups. Conclusions: The respondents knew very little about radiation safety and had low interest in their radiation exposure. To make the use of fluoroscopy safer, additional education, as well as attention to and knowledge of practices of radiation safety are required for pain physicians.

Radiation safety for pain physicians: principles and recommendations

  • Park, Sewon;Kim, Minjung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.35 no.2
    • /
    • pp.129-139
    • /
    • 2022
  • C-arm fluoroscopy is a useful tool for interventional pain management. However, with the increasing use of C-arm fluoroscopy, the risk of accumulated radiation exposure is a significant concern for pain physicians. Therefore, efforts are needed to reduce radiation exposure. There are three types of radiation exposure sources: (1) the primary X-ray beam, (2) scattered radiation, and (3) leakage from the X-ray tube. The major radiation exposure risk for most medical staff members is scattered radiation, the amount of which is affected by many factors. Pain physicians can reduce their radiation exposure by use of several effective methods, which utilize the following main principles: reducing the exposure time, increasing the distance from the radiation source, and radiation shielding. Some methods reduce not only the pain physician's but also the patient's radiation exposure. Taking images with collimation and minimal use of magnification are ways to reduce the intensity of the primary X-ray beam and the amount of scattered radiation. It is also important to carefully select the C-arm fluoroscopy mode, such as pulsed mode or low-dose mode, for ensuring the physician's and patient's radiation safety. Pain physicians should practice these principles and also be aware of the annual permissible radiation dose as well as checking their radiation exposure. This article aimed to review the literature on radiation safety in relation to C-arm fluoroscopy and provide recommendations to pain physicians during C-arm fluoroscopy-guided interventional pain management.

Toll-like Receptor 5 Agonism Protects Mice from Radiation Pneumonitis and Pulmonary Fibrosis

  • Wang, Zhi-Dong;Qiao, Yu-Lei;Tian, Xi-Feng;Zhang, Xue-Qing;Zhou, Shi-Xiang;Liu, Hai-Xiang;Chen, Ying
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.9
    • /
    • pp.4763-4767
    • /
    • 2012
  • Radiation pneumonitis and pulmonary fibrosis are the main complications with radiotherapy for thoracic neoplasms, directly limiting the efficient dose in clinical application and currently there are few medicines that effectively function as radioprotectants. However, a TLR5 agonist, CBLB502, was confirmed to have protective efficacy against hematopoietic and gastrointestinal radiation syndromes in mice and primates. This study points to a new direction for protection against thoracic radiation-induced pulmonary syndromes and skin injury by CBLB502. We utilized the TUNEL assay, pathological analysis and immunohistochemistry to obtain evidence thatCBLB502 could alleviate the occurrence of radiation pneumonitis and pulmonary fibrosis as well as radiation-induced skin injury. It may thus play a promising role in facilitating clinical radiotherapy of thoracic neoplasms.

Radiation Induced Lung Injury: Prediction, Assessment and Management

  • Giridhar, Prashanth;Mallick, Supriya;Rath, Goura Kishore;Julka, Pramod Kumar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.7
    • /
    • pp.2613-2617
    • /
    • 2015
  • Radiation induced lung injury has long been considered a treatment limiting factor for patients requiring thoracic radiation. This radiation induced lung injury happens early as well as late. Radiation induced lung injury can occur in two phases viz. early (< 6 months) when it is called radiation pneumonitis and late (>6 months) when it is called radiation induced lung fibrosis. There are multiple factors that can be patient, disease or treatment related that predict the incidence and severity of radiation pneumonitis. Radiation induced damage to the type I pneumocytes is the triggering factor to initiate such reactions. Over the years, radiation therapy has witnessed a paradigm shift in radiation planning and delivery and successfully reduced the incidence of lung injury. Radiation pneumonitis is usually a diagnosis of exclusion. Steroids, ACE inhibitors and pentoxyphylline constitute the cornerstone of therapy. Radiation induced lung fibrosis is another challenging aspect. The pathophysiology of radiation fibrosis includes continuing inflammation and microvascular changes due to pro-angiogenic and profibrogenic stimuli resembling those in adult bronchiectasis. General supportive management, mobilization of airway secretions, anti-inflammatory therapy and management of acute exacerbations remains the treatment option. Radiation induced lung injury is an inevitable accompaniment of thoracic radiation.

Preliminary Study of Protective Effects of Flavonoids against Radiation-induced Lung Injury in Mice

  • Wang, Juan;Xu, Heng-Wei;Li, Bao-Sheng;Zhang, Jian;Cheng, Jian
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.12
    • /
    • pp.6441-6446
    • /
    • 2012
  • Background: Radiation therapy plays an important role in lung carcinoma treatment. However, the incidence of symptomatic radiation-induced lung injury is high. This study aimed to evaluate radioprotective effects of flavonoids extracted from Astragalus complanatus and mechanisms of action against radiation damage. Methods: Alteration in antioxidant status and levles of several cytokines were investigated in BABL/C mice treated with 4 mg/kg b.wt. flavonoids after exposure to 10Gy thoracic radiation. Results: Serum levels of SOD in the flavonoids+radiation group were significantly higher compared to the radiation control group, while TGF-${\beta}1$ and IL-6 were lower. Mice in the radiation control group displayed more severe lung damage compared with the flavonoids+radiation group. The expression of TGF-${\beta}1$ and TNF-${\alpha}$ in the radiation control group was markedly increased in alveolar epithelial cells and macrophages of the alveolar septum. Conclusions: From the results of the present study, flavonoids could be excellent candidates as protective agents against radiation-induced lung injury.

IMAGING IN RADIATION THERAPY

  • Kim Si-Yong;Suh Tae-Suk
    • Nuclear Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.327-342
    • /
    • 2006
  • Radiation therapy is an important part of cancer treatment in which cancer patients are treated using high-energy radiation such as x-rays, gamma rays, electrons, protons, and neutrons. Currently, about half of all cancer patients receive radiation treatment during their whole cancer care process. The goal of radiation therapy is to deliver the necessary radiation dose to cancer cells while minimizing dose to surrounding normal tissues. Success of radiation therapy highly relies on how accurately 1) identifies the target and 2) aim radiation beam to the target. Both tasks are strongly dependent of imaging technology and many imaging modalities have been applied for radiation therapy such as CT (Computed Tomography), MRI (Magnetic Resonant Image), and PET (Positron Emission Tomogaphy). Recently, many researchers have given significant amount of effort to develop and improve imaging techniques for radiation therapy to enhance the overall quality of patient care. For example, advances in medical imaging technology have initiated the development of the state of the art radiation therapy techniques such as intensity modulated radiation therapy (IMRT), gated radiation therapy, tomotherapy, and image guided radiation therapy (IGRT). Capability of determining the local tumor volume and location of the tumor has been significantly improved by applying single or multi-modality imaging fur static or dynamic target. The use of multi-modality imaging provides a more reliable tumor volume, eventually leading to a better definitive local control. Image registration technique is essential to fuse two different image modalities and has been In significant improvement. Imaging equipments and their common applications that are in active use and/or under development in radiation therapy are reviewed.

REAL-TIME PERSONAL DOSE MEASUREMENT AND MANAGEMENT SYSTEM RESEARCH IN CHINA

  • Zhang, Z.Y.;Cheng, C.;Liu, Z.S.;Yang, H.T.;Deng, C.M.;Zhang, X.;Guo, Z.J.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.281-286
    • /
    • 2001
  • The composition and design of a real-time personal dose measurement and management system are described in this paper. Accordingly, some pertinent hardware circuits and software codes including their operation modes have also been presented.

  • PDF

Status of Medical Exposure in Korea

  • Yoon, Sei-Chul;Kim, Il-Han;Kim, Sung-Hoon;Kim, Hyuck-Joo
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.96-98
    • /
    • 2010
  • Medical use of radiation is increasing in recent times and its influence on the population creates almost the same amount of annual natural background radiation in industrialized countries in particular. Thus, medical radiation has become a social issue. This paper is a brief report on the status of medical exposure in Korea by way of consulting from the radiation-related medical societies in Korea.