• Title/Summary/Keyword: radial fracture

Search Result 143, Processing Time 0.034 seconds

Osborne-Cotterill Lesion a Forgotten Injury: Review Article and Case Report

  • Vargas, Daniel Gaitan;Woodcock, Santiago;Porto, Guido Fierro;Gonzalez, Juan Carlos
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.1
    • /
    • pp.27-30
    • /
    • 2020
  • Osborne-Cotterill lesion is an osteochondral fracture located in the posterolateral margin of the humeral capitellum, which may be associated with a defect of the radial head after an elbow dislocation. This lesion causes instability by affecting the lateral ulnar collateral ligament over its capitellar insertion, which is associated with a residual capsular laxity, thereby leading to poor coverage of the radial head, and hence resulting in frequent dislocations. We present a 54-year-old patient, a physician who underwent trauma of the left elbow after falling from a bike and suffered a posterior dislocation fracture of the elbow. The patient subsequently presented episodes of instability, and additional work-up studies diagnosed the occurrence of Osborne-Cotterill lesion. An open reduction and internal fixation of the bony lesion was performed, with reinsertion of the lateral ligamentous complex. Three months after surgery, the patient was asymptomatic, having a flexion of 130° and extension of 0°, and resumed his daily activities without any limitation. Currently, the patient remains asymptomatic 2 years after the procedure. Elbow instability includes a large spectrum of pathological conditions that affect the biomechanics of the joint. The Osborne-Cotterill lesion is one among these conditions. It is a pathology that is often forgotten and easily overlooked. Undoubtedly, this lesion requires surgical intervention.

Numerical Simulation of Fracture Mechanism by Blasting using PFC2D (PFC2D에서의 발파에 의한 파괴 메커니즘의 수치적 모델링)

  • Jong, Yong-Hun;Lee, Chung-In;Jeon, Seok-Won
    • Tunnel and Underground Space
    • /
    • v.16 no.6 s.65
    • /
    • pp.476-485
    • /
    • 2006
  • During blasting, both shock wave and gas are generated in detonation process of explosives and the generated wave and gas expansion may create new fractures and damage rock mass. In order to explain and understand completely the fracture mechanism by blasting, we have to consider both effects of the wave and gas expansion simultaneously. In this study, we use a discrete element code, PFC2D and develop an algorithm which is capable of modeling both detonation and gas pressures acting on blasthole wall and visualizing generated cracks within rock mass. Moreover, the gas-pressure modeling method which applies a corresponding external force of gas pressure to parent particles of radial fractures is adopted to simulate a coopting between rock mass and gas penetrating created radial fractures. The developed algorithm is verified by reproducing numerical simulations of a lab-scale test blast successfully.

Studies on Criterion for Mixed Mode Fracture in Glulam (집성재(集成材)의 혼합모드 하중시 파괴(破壞) 기준(基準)에 관한 연구(硏究))

  • Lee, Jee-Yong;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.15-22
    • /
    • 1993
  • This study was carried out to investigate the fracture criterion of glulam. The mixed mode fracture of glulam was investigated by means of single edge notched specimens with various crack inclination in the longitudinal-radial plane. While fracture of wood is not completely understood, the study on linear-elastic fracture mechanics is a rational and valuable tool for studying the strength behavior of glulam. The results are summarized as follows : 1. Glue line has no effect on fracture strength. 2. There is a definite interaction between fracture toughness $K_I$ and $K_{II}$ during the mixed mode fracture of glulam. Several criterions for mixed mode failure were compared. The criterion was expressed in the following form: $(\frac{K_I}{K_{IC}})^2+(\frac{K_{II}}{K_{IIC}})^2=1$ 3. As crack inclination increases, $K_{IC}$ value and $K_{IIC}$ value decreases. The equations relating crack angle to $K_{IC}$ and $K_{IIC}$, respectively, were obtained as follows; $K_{IC}$ = -77.42${\gamma}$+153.72 ($R^2$ = 0.78) $K_{IIC}$ = -9.17${\gamma}$+34.90 ($R^2$ = 0.48)

  • PDF

An experimental study on the hydraulic fracturing of radial horizontal wells

  • Yan, Chuanliang;Ren, Xu;Cheng, Yuanfang;Zhao, Kai;Deng, Fucheng;Liang, Qimin;Zhang, Jincheng;Li, Yang;Li, Qingchao
    • Geomechanics and Engineering
    • /
    • v.17 no.6
    • /
    • pp.535-541
    • /
    • 2019
  • Combining the radial well drilling and hydraulic fracturing technique, the production capacity of the reservoirs with low-permeability can be improved effectively. Due to the existence of radial holes, the stress around the well is redistributed, and the initiation and propagation of hydraulic fractures are different with those in traditional hydraulic fracturing. Therefore, it is necessary to study the influences of radial horizontal wells on hydraulic fracturing. The laboratory experiment was conducted to simulate the hydraulic fracturing on the physical model with radial holes. The experimental results showed that, compared with the borehole without radial holes, the sample with radial hole in the direction of maximum horizontal stress was fractured with significantly lower pressure. As the angle between direction of the horizontal hole and the maximum horizontal stress increased, the breakdown pressure grew. While when the radial hole was drilled towards the direction of the minimum horizontal stress, the breakdown pressure increased to that needed in the borehole without radial holes. When the angle between the radial hole and the maximum horizontal stress increase, the pressure required to propagate the fractures grew apparently, and the fracture become complex. Meanwhile, the deeper the radial hole drilled, the less the pressure was needed for fracturing.

Transition Mechanism from Brittle Fracture to Ductile Shear when Machining Brittle Materials with an Abrasive Waterjet

  • Huang, Chuanzhen;Zhu, Hongtao;Lu, Xinyu;Li, Quanlai;Che, Cuilian
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.2
    • /
    • pp.11-17
    • /
    • 2008
  • Critical erosion kinetic energy models for radial/median cracks and lateral cracks in a workpiece are established in this study. We used experimental results to demonstrate that the fracture erosion resistance and erosion machining number could be used to evaluate the brittle fracture resistance and machinability of a workpiece. Erosion kinetic energy models were developed to predict brittle fracture and ductile shear, and a critical erosion kinetic energy model was developed to predict the transition from brittle fracture to ductile shear. These models were verified experimentally.

The Result of Conservative Treatment in Displaced Radial Head Fracture (전위된 요골두 골절의 보존적 치료의 결과)

  • Yi, Seung-Rim;Hahn, Sung-Ho;An, Young-Joon;Yoo, Jae-Ho;Jeon, Do-Whan;Yang, Bo-Kyu
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.4 no.1
    • /
    • pp.43-48
    • /
    • 2005
  • Purpose: The purpose of this study is to assess the result of conservative treatment in displaced radial head fracture. Materials and Methods: We analyzed 15 cases of displaced radial head fracture who were treated conservatively from April 1992 to May 2002. Follow-up period was more than 1 year. They were all males and the average age of patients was 20.2($11{\sim}24$) years. The average follow-up period was 13.4($12{\sim}15$) months. They were able to do active pronation and supination more than 70 degrees initially, who were applied long arm splint less than 1 week. The functional rating index modified after B.F. Morrey and no further displacement and union state of fragment in simple X-ray were used in follow-up assessment. Results: On the basis of the functional rating index modified after B.F. Morrey that included elements of pain, motion, strength, and stability, the results were 8 excellent, 7 good in patients who were treated conservatively, who had union and no further displacement of fragment in follow-up. Conclusion: We conclude that if they are able to do active pronation and supination more than 70 degrees initially, we take them to do early range of motion exercise after subsiding swelling, which can restrict limitation of range of motion exercise and return to the living early.

  • PDF

The Clinical usefulness of the tangential projection view of Radius groove after Distal Radius Fracture operation using the T-type Plat (전방 잠금형 금속판을 이용한 요골 원위부 골절수술 후 요골구 접선방향 촬영법의 임상적 유용성)

  • Seo, Sun-Youl;Cho, Jeong-Hee;Han, Man-Seok;Kim, Tae-Hyung;Yoo, Se-Jong;Kim, Yong-Kyun;Han, Dong-Kyoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2760-2766
    • /
    • 2013
  • Introduction : The projection method to check existence and nonexistence of radius groove penetration of screw after distal radius fracture operation clinical using the T-type plate and the radiation of radial groove tangential is to propose a new test. Material and Methods : On the tangential projection view of radius groove, elevation angle of distal radius is 2.5, 5, 7.5, 10 degree. and forearm and radiation detector of angle is 60, 70, 80, degree each changed. that analyzed check existence and nonexistence of radius groove penetration of screw. Results : For the image of Radial groove tangential. the case of not radius groove penetration of screw(63.95%, n=55), medial penetration of radius groove(10.47%, n=9) or lateral penetration of radius groove(25.58%, n=22) was analysis. The radius groove penetrating of screw length was a range of 0.43 ~ 2.72mm, the average was 1.06mm. the check existence and nonexistence of radius groove penetration of medial or lateral was analysis that it accurate for the image of Radial groove tangential. the radiography of radial groove is well described elevation angle of distal radius 2.5 to 7.5 degree(90% over), forearm and radiation detector of angle 70degree(80%over) Conclusion : It is elevation angle of distal radius is 5degree, forearm and radiation detector of angle 70degree recommended.

Operative Treatment of Terrible Triad in Elbow of Adults (성인 주관절의 요골두와 구상돌기 골절을 동반한 탈구의 수술 적 치료 (성인 주관절에 발생한 위험3증주의 수술적 치료))

  • Kim, Byung-Heum;Park, Jong-Seok;Choi, Ho-Rim;Lee, Sang-Sun;Rah, Soo-Kyun;Lee, Hyun-Wook
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.1
    • /
    • pp.50-59
    • /
    • 2006
  • Purpose: The nonoperative outcome of elbow dislocations with associated radial head and coronoid fractures are often unsatisfactory because of chronic instability and stiffness from proloned immobilization, Therefore we managed these injuries with well programed surgical appproaches. Method: Ten patients with this injury were evaluated retrospectively from May 1998 to June 2004 after a minimum of 12 months. These injuries include elbow dislocation and associated fractures of both the radial head and the coronoid process. All ten patients were treated by one clinic operatively with similar scheduled surgical methods which started on the lateral side and terminated on the medial side of the elbow. Radial head and neck fractures were classified Mason types, as two and three types respectively with six and four cases and six cases were fixated. Coronoid process were fixated with screws anteroposterior directly or anchor suture in all cases, each type was classified one, two and three. where were three type one, four type two, and three type three were according to Regan and Morrey classification. Results: The outcome was three resulting in excellent, four good, two normaland and the remaining case was one poor according to the Mayo Elbow Performance score. At a terminal follow up, the range of motion of the elbow averaged flection contracture, $6^{\circ}(0{\sim}20^{\circ})$ and further flection, $129^{\circ}(115{\sim}140^{\circ})$. Two patients had complications requiring additional care. One, displaced coronoid process which was repaired with capsule and the other patient experienced, palsy of ulnar nerve and contracted elbow joint. Conclusions: Usage of early operation as the minimum injury of medial ligaments complex and the rigid fixation of fractures to prompt motion with our scheduled management for elbow dislocations with associated radial head and coracoid fractures provided excellent results.

Anterior Dislocation of the Radial Head Combined with Plastic Deformity of the Ulnar Shaft in an Adult: A Case Report

  • Moon, Sang Won;Kim, Youngbok;Kim, Young-Chang;Kim, Ji-Wan;Yoon, Taiyeon;Kim, Seung-Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.1
    • /
    • pp.42-47
    • /
    • 2018
  • A 25-year-old woman presented to the emergency room with a painful and swollen right forearm. She had just sustained an injury from an accident during which her arm was tightly wound by a rope as she was lowering a net from a fishing boat. Before being released, her arm was rigidly trapped in the rope for approximately ten minutes. Radiographs revealed anterior dislocation of the radial head that was accompanied by plastic deformation of the proximal ulna, manifested as a reversal of the proximal dorsal angulation of the ulna (PUDA); suggested a Monteggia equivalent fracture. With the patient under general anesthesia, we reduced the radial head by posterior compression at $90^{\circ}$ of elbow flexion and at neutral rotation of the forearm. However, the reduction was easily lost and the elbow re-dislocated with even slight supination or extension of the arm. After the osteotomy of the ulnar deformity to restore the PUDA to normal, the reduction remained stable even with manipulation of the arm. We found that the patient could exercise a full range of motion without pain at the 3-month follow-up, and neither residual instability nor degenerative changes were observed at the final 3-year follow-up.