• 제목/요약/키워드: radial distribution

검색결과 851건 처리시간 0.027초

THE DISTRIBUTION OF DUST INSIDE THE ORION NEBULA

  • Shin, Jun-Ho;Hong, Seung-Soo
    • 천문학회지
    • /
    • 제20권1호
    • /
    • pp.1-26
    • /
    • 1987
  • By inverting the brightness integral for the dust-scattered continuum, we have determined how the dust grains are distributed inside the Orion nebula. The scattering characteristics of the Orion dust at a given wavelength is kept constant within the nebula, and the geometry of the nebula is assumed to have a hemispherical shape. The resulting radial distance dependence of the distribution of dust number density, $N_d(r)$, shows that the dust grains are depleted at the central region of the Orion nebula and concentrated in the region $5'{\sim}6'$ away from the Trapezium stars. The scattering characteristics of the Orion dust are of moderately forward throwing nature, and the Orion dust has low values of albedo.

  • PDF

고주파 유도방전 플라즈마 특성에 관한 연구( I ) (A Study on the Characteristics of the Radio-Frequency Inductive Discharge Plasma)

  • 박성근;박상윤;박원주;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1996년도 추계학술발표회논문집
    • /
    • pp.63-66
    • /
    • 1996
  • Electron temperature and electron density were measured in a radio-frequency(rf) inductively coupled plasma using probe measurements. Measurements were made in an argon discharge for pressures from 10 to 100mTorr and input rf power from 100 to 800W. Spatial distribution Electron temperature and electron density were measured for discharge with same aspect ratio. Electron temperature and Electron density were found to depend on both pressure and power. Electron density was creased with increasing pressure, but peaked in a 70mTorr discharge. Radial distribution of the electron density was peaked in the plasma fringes. These results were compared to a simple model of inductively coupled plasmas.

  • PDF

경험적 탐색기법에 근거한 배전계통의 선로 재구성 앨고리즘 (NETWORK RECONFIGURATION ALGORITHM FOR AUTOMATED DISTRIBUTION SYSTEM BASED ON THE BEST-FIRST TREE SEARCH)

  • 정경희;김호용;고윤석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.350-353
    • /
    • 1991
  • This study develops an expert system which solves the problems of the MTr/feeder overloads and the feeder constraints in automated radial distribution systems. Then, the objective is to perform the network reconfiguration by switching the tie and sectionalizing switches which eliminates the system violation, while achieving the load balance of the MTrs/feeders. To reduce the search space, an expert system based on heuristic rules is presented, and implemented in AI language Prolog. This system adopts the best-first tree search technique. The computational results are also prepared to show the performance of the heuristic algorithm developed.

  • PDF

회전하는 타이어 내부공기의 유동특성에 관한 실험적 연구 -무부하 회전구동 타이어- (An Experimental Study on the Characteristics of Air Flow Velocity Distritutions Inside a Rolling Tire -Unloaded Rolling Tire-)

  • 김윤제;조정현
    • 한국자동차공학회논문집
    • /
    • 제7권6호
    • /
    • pp.174-181
    • /
    • 1999
  • in order to elucidate the characteristic of velocity distribution of the cavity air. Exploratory tests were conducted on an unloaded rolling radial tire operated at various speeds and inflation pressure. A hot-wire anemometer, rotating with the tire, was used to measure the flow velocity inside the tire cavity. Tow different types of experiments were performed ; one for the effects of rolling speed with constant inflation pressure, the other for the various cavity pressures with constant rolling speed. Experimental results are given as plots of the mean velocity distributions versus the distance from the rim. It is observed that the magnitude of mean velocity in the cavity air shows increasing natures with the increasing of the inflation pressures and rolling speeds.

  • PDF

Derivation of Distributed Generation Impact Factor in a Networked System in Case of Simultaneous Outputs of Multiple Generation Sites

  • Lim, Jung-Uk;Runolfsson, Thordur
    • 조명전기설비학회논문지
    • /
    • 제20권9호
    • /
    • pp.78-83
    • /
    • 2006
  • A new measure, the distributed generation impact factor (DGIF), is used for evaluating the impact of newly introduced distributed generators on a networked distribution or a transmission system. Distribution systems are normally operated in a radial structure. But the introduction of distributed generation needs load flow calculation to analyze the networked system. In the developed framework, the potential share of every generation bus in each line flow of a networked system can be directly evaluated. The developed index does not require the solution of power flow equations to evaluate the effect of the distributed generation. The main advantage of the developed method lies in its capability of considering simultaneous outputs of multiple generation sites.

Transient heat transfer analysis of functionally graded CNT reinforced cylinders with various boundary conditions

  • Moradi-Dastjerdi, Rasool;Payganeh, Gholamhassan
    • Steel and Composite Structures
    • /
    • 제24권3호
    • /
    • pp.359-367
    • /
    • 2017
  • In this work, transient heat transfer analysis of functionally graded (FG) carbon nanotube reinforced nanocomposite (CNTRC) cylinders with various essential and natural boundary conditions is investigated by a mesh-free method. The cylinders are subjected to thermal flux, convection environments and constant temperature faces. The material properties of the nanocomposite are estimated by an extended micro mechanical model in volume fraction form. The distribution of carbon nanotube (CNT) has a linear variation along the radial direction of axisymmetric cylinder. In the mesh-free analysis, moving least squares shape functions are used for approximation of temperature field in the weak form of heat transform equation and the transformation method is used for the imposition of essential boundary conditions. Newmark method is applied for solution time depended problem. The effects of CNT distribution pattern and volume fraction, cylinder thickness and boundary conditions are investigated on the transient temperature field of the nanocomposite cylinders.

지중배전 케이블의 특성분석 - 화학구조결함, 불순물, 가교도, 수축율 - (Characterization of Undergrounded Distribution Cables - Chemical Structural Defects, Impurities, Degree of Crosslinking and Shrinkage)

  • 김종은;고정우;서광석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.130-134
    • /
    • 1997
  • The structural defects, impurities, degree of crosslinking and shrinkage of 38 field-aged distribution cables have been analyzed. For the comparison of data, 9 new cables were also subjected to an analysis. It is observed that the structural defects and degree of crosslinking show a radial profile. The structural defects are different depending on the manufacturer. A large amount of impurities is present in the insulation shield, which hold true for the new cables manufactured recently. The degree of crosslinking near both shields is lower than that at the central region of the insulation layer. It was also found that, in some cal)toes, the ins난lation was not fully crosslinked. The shrinkage of field-aged cables is higher than that of new cables.

  • PDF

배전자동화 시스템에서 분포부하를 고려한 새로운 조류계산 알고리즘 (A New Load Flow Algorithm based on DAS with Considering Distributed Load)

  • 양하;최면송;임일형;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.169-170
    • /
    • 2006
  • In this paper, A new algorithm for load flow calculation is proposed for radial distribution network. Feeder Remote Terminal Unit (FRTU) is utilized to collect data such as current magnitude and angle of power factor at each node. Proposed algorithm is based on the model of distributed load in distribution system. Load flow calculation is using four terminal constants method.

  • PDF

Load Flow Calculation and Short Circuit Faults Transients in Dispersed Generation Systems

  • Hosseini, Seyed Hossein;Shahnia, Farhad;Tizghadam, Saeed
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.800-804
    • /
    • 2005
  • Load flow and short circuit fault transients of a power distribution system with wind turbines as dispersed generation units is presented. Usage of renewable energies such as wind is already a small part of total installed power system in medium and low voltage networks. In this paper, a radial power distribution system with wind turbines is simulated using DIgSILENT PowerFactory software for their influence on load flow and short circuit fault transients. Short fault occurring in dispersed generation systems causes some problems for the system and costumers such as fault level increase or the problems of sudden fluctuations in the current, voltage, power and torque of the double fed induction machine utilized in the wind turbines which have been studied and investigated.

  • PDF

BLUE STRAGGLER STARS IN THE GLOBULAR CLUSTER M53

  • REY SOO-CHANG;LEE YOUNG-WOOK;CHUN MUN-SUK;BYUN YONG-IK
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.137-138
    • /
    • 1996
  • The first large-format CCD color-magnitude diagram (CMD) in the B and V passbands is presented for the Galactic globular cluster M53 (NGC 5024). We have discovered 117 new blue straggler (BS) candidates in the field of M53. The analysis of bright BS stars (V <19.0) clearly shows a bimodal radial distribution, with a high frequency in the inner and outer regions. The distribution is similar to that found in M3, a globular cluster with similar central density and concentration.

  • PDF