• Title/Summary/Keyword: r값

Search Result 126, Processing Time 0.021 seconds

The Usefulness in an Automated Kinetic Method in Determining of ADA Activity in Pleural Fluid (자동화학분석기를 이용한 흉막액내 ADA 활성치 측정의 유용성에 관한 연구)

  • Ryu, Jeong-Seon;Yong, Suk-Joong;Song, Kwang-Seon;Shin, Kye-Chul;Lee, Won-Sik;Kang, Shin-Ku;Uh, Young;Yoon, Kap-Jun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.838-845
    • /
    • 1995
  • The determination of ADA(adenosine deaminase) activity in pleural fluid is useful in differental diagnosis of pleural effusion. The conventional method of determining ADA activity used by Giusti was influenced by contamination of ammonia. Additionally, because Giusti's method was mannual method a determining the ADA activities in sample, was not easily automated. In 1993, Oosthuizen HM with collegues developed simple kinetic method for determining ADA activity. It was reliable and suiable method for automation. In this study, we have measured ADA activity in 162 patients with various pleural effusion by Hitachi 747 autoanalyser using the Oosthuizen kinetic method for the purpuse of determination of new diagnostic cut-off value for the tuberculous effusion and evaluation of the correlation between the conventional method and new automated method. This new method of an enzymatic reaction involves 2, 6-dichlorophenolindophenol dye(DICP), adenosine, xanthine oxidase(XO), and nucleoside phosphorylase(NP). The results were as follows: 1) The mean pleural ADA activity of the tuberculous effusion was $52.53{\pm}16.43\;U/L$ and significantly higher than that of other groups(p<0.001). If the diagnostic cut-off value of pleural ADA activity for tuberculous effusion is above 30 U/L, the sensitivity is 96% and the specificity is 90%. 2) The mean pleural to serum ADA activity ratio of the tuberculous effusion was $2.29{\pm}0.96$ and it was also significantly higher than that of other pleural groups(p<0.001). If the diagnostic cut-off value of pleural to serum ADA activity ratio is 1.5, the sensitivity is 80% and the specificity is 88% in the diagnosis of tuberculous pleural effusion. 3) The new kinetic method is correlates well to Giuisti's conventional method(r=0.971). In conclusion, the new kinetic method described is easily automated and seems to be suitable for the routine determination of ADA activity.

  • PDF

The Crystal and Molecular Structure of 25,26,27,28-Tetrnacetoxy[4]Arene${\cdot}$Monohydrate (25,26,27,28-테트라아세트오키시[4]에렌${\cdot}$일수화물의 결정 및 분자구조)

  • Choong Tai Ahn;Kwanghyun No
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.3
    • /
    • pp.344-350
    • /
    • 1993
  • 25,26,27,28-Tetraacetoxycalix[4]arene·monohydrate is orthorhombic, space group Pbca with a = 14.979(4), b = 15.154(4), c = 27.890(3) ${\AA}$, Z = 8, V = 6330.6 ${\AA}^{-3}$, D$_c$ = 1.28 $g{\cdot}cm^{-3}$, (Mo K${\alpha}$) = 0.71069 ${\AA}$, ${\mu}$ = 0.86 cm$^{-1}$, F(000) = 2600, and R = 0.069 for 3376 unique observed reflections with I > 1.0 ${\sigma}$(I). The structure was solved by direct methods and refined by cascade diagonal least-squares refinement. All the C-H bond lengths(= 0.96 ${\AA}$), the methyl groups and the methylene groups are fixed and refined as the rigid groups with ideal geometry. The macrocycle exists in the 1,3 alternate conformation (by Conforth) making the angles of 110.7, 684, 113.7 and 68.8$^{\circ}$ between the benzene rings and the methylenic mean plane, and four each acetoxy groups are twisted away from their own benzene rings with the angles of 68.2, 97.6, 78.9 and 71.3$^{\circ}$, respectively. The relative dihedral angles between two opposite side of the benzene rings are 135.6$^{\circ}$ for the rings (1) and (3) and 135.2$^{\circ}$ for (2) and (4). A water molecule which has nearly the same height of the methylenic plane of the macrocycle in the c-axis, is located within the distances of 2.942(5) ${\AA}$ from the O(8) atom of the carbonyl group and 2.901 ${\AA}$ from, another O(2)(1/2-x, -1/2+y, z). The shortest contact between the molecule is 3.193 ${\AA}$ from the O(4) to the C(3)(1/2+x, 1/2-y,-z).

  • PDF

Evaluation of MODIS-derived Evapotranspiration at the Flux Tower Sites in East Asia (동아시아 지역의 플럭스 타워 관측지에 대한 MODIS 위성영상 기반의 증발산 평가)

  • Jeong, Seung-Taek;Jang, Keun-Chang;Kang, Sin-Kyu;Kim, Joon;Kondo, Hiroaki;Gamo, Minoru;Asanuma, Jun;Saigusa, Nobuko;Wang, Shaoqiang;Han, Shijie
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.4
    • /
    • pp.174-184
    • /
    • 2009
  • Evapotranspiration (ET) is one of the major hydrologic processes in terrestrial ecosystems. A reliable estimation of spatially representavtive ET is necessary for deriving regional water budget, primary productivity of vegetation, and feedbacks of land surface to regional climate. Moderate resolution imaging spectroradiometer (MODIS) provides an opportunity to monitor ET for wide area at daily time scale. In this study, we applied a MODIS-based ET algorithm and tested its reliability for nine flux tower sites in East Asia. This is a stand-alone MODIS algorithm based on the Penman-Monteith equation and uses input data derived from MODIS. Instantaneous ET was estimated and scaled up to daily ET. For six flux sites, the MODIS-derived instantaneous ET showed a good agreement with the measured data ($r^2=0.38$ to 0.73, ME = -44 to $+31W\;m^{-2}$, RMSE =48 to $111W\;m^{-2}$). However, for the other three sites, a poor agreement was observed. The predictability of MODIS ET was improved when the up-scaled daily ET was used ($r^2\;=\;0.48$ to 0.89, ME = -0.7 to $-0.6\;mm\;day^{-1}$, $RMSE=\;0.5{\sim}1.1\;mm\;day^{-1}$). Errors in the canopy conductance were identified as a primary factor of uncertainty in MODIS-derived ET and hence, a more reliable estimation of canopy conductance is necessary to increase the accuracy of MODIS ET.

Interaction between Invertebrate Grazers and Seaweeds in the East Coast of Korea (동해안 조식성 무척추동물과 해조류 간 상호작용)

  • Yoo, J.W.;Kim, H.J.;Lee, H.J.;Lee, C.G.;Kim, C.S.;Hong, J.S.;Hong, J.P.;Kim, D.S.
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.12 no.3
    • /
    • pp.125-132
    • /
    • 2007
  • We estimated the distribution of predator-prey interaction strengths for 12 species of herbivores (including amphipods, isopods, gastropods, and sea urchins) and made a regression model that may be applicable to other species. Laboratory experiments were used to determine per capita grazing rate (PCGR; g seaweeds/individual/day). Relationship between the biomass of individual grazers and fourth-root transformed PCGR was fitted to power curve ($y=0.2310x^{0.3290}$, r=0.8864). This finding supported that the grazing efficiency was not even as individual grazers increase in size (biomass). Therefore, the biomass-normalized PCGR was estimated and revealed that smaller size herbivores were more effective grazers. Grazing impact considering density of each taxon was calculated. The sea hare Aplysia kurodai had greatest grazing impact on the seaweed bed and the sea urchin Strongylocentrotus nudus and S. intermedius were ranked in descending order of the impact. The amount of seaweed grazed by the amphipod Elasmopus sp. (>4,000 $ind./m^2$) and Jassa falcata (>2,000 $ind./m^2$) were 3.435 and $1.697mg/m^2/day$ respectively. The combined grazing amount of herbivores was $5,045mg/m^2/day$ in the seaweed bed. Although sea hare and sea urchin had strong impacts on seaweeds, the effects of dense, smaller species could not be seen as negligible. Surprisingly, the calculated grazing potential of sea urchins with a mean density of 3 $ind./m^2$ exceeded the mean production of seaweed cultured in domestic coastal waters in Korea (ca., 5 ton/ha). Small crustaceans were also expected to consume up to 16% of the seaweed production if their densities were rising under weak predation conditions. Considering that the population density of herbivores are strongly controlled by fish, human interference like overfishing may have strong negative effects on persistence of seaweeds communities.

The Effect of Using Two Different Type of Dose Calibrators on In Vivo Standard Uptake Value of FDG PET (FDG 사용 시 Dose Calibrator에 따른 SUV에 미치는 영향)

  • Park, Young-Jae;Bang, Seong-Ae;Lee, Seung-Min;Kim, Sang-Un;Ko, Gil-Man;Lee, Kyung-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.115-121
    • /
    • 2010
  • Purpose: The purpose of this study is to measure F-18 FDG with two different types of dose calibrator measuring radionuclide and radioactivity and investigate the effect of F-18 FDG on SUV (Standard Uptake Value) in human body. Materials and Methods: Two different dose calibrators used in this study are CRC-15 Dual PET (Capintec) and CRC-15R (Capintec). Inject 1 mL, 2 mL, 3 mL of F-18 FDG into three 2 mL syringes, respectively, and measure initial radioactivity from each dose calibrator. Then measure and record radioactivity at 30 minute interval for 270 minutes. According to the initial radioactivity, linearity between decay factor driven from radioactive decay formula and the values measured by dose calibrator have been analyzed by simple linear regression. Fine linear regression line optimizing values measured with CRC-15 through regression analysis on the basis of the volume of which the measured value is close to the most ideal one in CRC-15 Dual PET. Create ROI on lung, liver, and region part of 50 persons who has taken PET/CT test, applying values from linear regression equation, and find SUV. We have also performed paired t-test to examine statistically significant difference in the radioactivity measured with CRC-15 Dual PET, CRC-15R and its SUV. Results: Regression analysis of radioactivity measured with CRC-15 Dual PET and CRC-15R shows results as follows: in the case 1 mL, the r statistic representing correlation was 0.9999 and linear regression equation was y=1.0345x+0.2601; in 2 mL case, r=0.9999, linear regression equation y=1.0226x+0.1669; in 3 mL case, r=0.9999, linear regression equation y=1.0094x+0.1577. Based on the linear regression equation from each volume, t-test results show significant difference in SUV of ROI in lung, liver, region part in all three case. P-values in each case are as follows: in 1 mL case, lung, liver and region (p<0.0001); in 2 mL case, lung (p<0.002), liver and region (p<0.0001); in 3 mL case, lung (p<0.044), liver and region (p<0.0001). Conclusion: Radioactivity measured with CRC-15 Dual PET, CRC-15R, dose calibrator for F-18 FDG test, do not show difference correlation, while these values infer that SUV has significant differences in the aspect of uptake in human body. Therefore, it is necessary to consider the difference of SUV in human body when using these dose calibrator.

  • PDF

Breathing Reserve Index at Anaerobic Threshold of Cardiopulmonary Exercise Test in Chronic Obstructive Pulmonary Disease (만성폐쇄성 폐질환의 운동부하 심폐기능검사에서 무산소역치 예비호흡지수의 의의)

  • Lee, Byoung-Hoon;Kang, Soon-Bock;Park, Sung-Jin;Jee, Hyun-Suk;Choi, Jae-Chol;Park, Yong-Bum;Ahn, Chang-Hyuk;Kim, Jae-Yeol;Park, In-Won;Choi, Byung-Whui;Hue, Sung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.795-802
    • /
    • 1999
  • Objective : Cardiopulmonary exercise test is a useful tool to evaluate the operative risk and to plan exercise treatment for the patients with chronic obstructive pulmonary disease(COPD). In cardiopulmonary exercise test, most of the measured parameters are recorded at the time of peak exercise, which are hard to attain in COPD patients. So we evaluated the usefulness of the parameter, breathing reserve index(BRI=minute ventilation [$V_E$]/maximal voluntary ventilation[MVV]) at the time of anaerobic threshold($BRI_{AT}$) for the differentiation of COPD patients with normal controls. Methods : Thirty-six COPD patients and forty-two healthy subjects underwent progressive, incremental exercise test with bicycle ergometer upto possible maximal exercise. All the parameters was measured by breath by breath method. Results : The maximal oxygen uptake in COPD patients (mean$\pm$SE) was $1061.2{\pm}65.6ml/min$ which was significantly lower than $2137.6{\pm}91.4ml/min$ of normal subjects(p<0.01). Percent predicted maximal oxygen uptake was 54.3% in COPD patients and 86.0% in normal subjects(p<0.01). Maximal exercise(respiratory quotient; $VCO_2/VO_2{\geq}1.09$) was accomplished in 7 of 36 COPD patients(19.4%) and in 18 of 42 normal subjects(42.9%). The $BRI_{AT}$ of COPD patients was higher($0.50{\pm}0.03$) than that of control subject($028{\pm}0.02$, p<0.01), reflecting early hyperventilation in COPD patient during exercise. The correlation between $BRI_{AT}$ and BRI at maximal exercise in COPD patients was good(r=0.9687, p<0.01). Conclusion : The $BRI_{AT}$ could be a useful parameter for the differentiation of COPD patients with normal controls in the submaximal cardiopulmonary exercise test.

  • PDF