• Title/Summary/Keyword: quantitative image

Search Result 1,402, Processing Time 0.025 seconds

Digital Color Imaging Systems for Quantitative Evaluation of Skin Lesions (피부병변의 정량적 평가를 위한 디지털 컬러 영상 시스템)

  • Han, Byung-Kwan;Jung, Byung-Jo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.195-198
    • /
    • 2007
  • In this paper, we introduce a digital cross-polarization and fluorescent color imaging system for quantitative evaluation of skin lesions. We describe the characterization of the imaging systems and the quantitative image analysis methods to show the feasibility for quantitative evaluation of skin lesions. The polarization color image was used to compute erythema and melanin index image which are useful for quantitative evaluation of pigmentation and vascular skin lesions, respectively. The fluorescent color image was used to quantitatively evaluate "sebum" and "vitiligo". In quantitative evaluation of various skin lesions, we confirmed the clinical efficacy of the imaging systems for dermatological applications. Finally, we sure that the imaging systems can be utilized as important assistant tools for the evaluation of skin lesions by providing reproducible quantitative result for widely distributed skin lesions.

The Assessment on the Characteristics of Quantitative Image in Digora$\textregistered$ (Digora$\textregistered$에서 정량영상의 특성에 대한 평가)

  • Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.397-405
    • /
    • 1999
  • Purpose: To clarify the usefulness and the limitation of Digora system/sup (R)/ by evaluating the physical characteristics as the quantitative image on Image Plate(Ip). Materials and Methods: Radiograms were taken by Heliodent MD(Siemens Co.. Germany) with the image plate for adult. Cu-step wedge as reference material. and three pieces of dry mandibular bone. Image analysis was performed by single color enhancement. density measurement with histogram. The relationship between the exposure conditions and the distribution of the pixel values of the image. the variation of pixel values of each step of Cu-step wedge at two different area and Cu-equivalent value of three pieces of dry mandibular bone measure by the conversion equation. Results: There was no linear relationship between the exposure condition and the average pixel value of the image. of which the distribution was not even. The pixel value differences between the center portion and the periphery were ranged from 60 to 70 in vertical plane and from 15 to 26 in horizontal plane. Two plot profile formed at two different areas of the Cu-step wedge were different. The measured Cu-equivalent values showed the discrepancy among the times of measurement. Conclusion: As above results. Image Plate(Ip) of Digora system/sup (R)/ showed the limitation as the quantitative image. The physical property of IP was expected to need to be compensated for the quantitative evaluation of the bone or others

  • PDF

Comparison of Quantitative Analysis of Radioactive Corrosion Products Using an EPMA and X-ray Image Mapping

  • Jung, Yang Hong;Choo, Young Sun
    • Corrosion Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.231-238
    • /
    • 2020
  • Radioactive corrosion product specimens were analyzed using an electron probe microanalyzer (EPMA) and X-ray image mapping. It is difficult to analyze the composition of radioactive corrosion products using an EPMA due to the size and rough shape of the surfaces. It is particularly challenging to analyze the composition of radioactive corrosion products in the form of piled up, small grains. However, useful results can be derived by applying a semi-quantitative analysis method using an EPMA with X-ray images. A standard-less, semi-quantitative method for wavelength dispersive spectrometry. EPMA analysis was developed with the objective of simplifying the analytical procedure required. In this study, we verified the reasonable theory of semi-quantitative analysis and observed the semi-quantitative results using a sample with a good surface condition. Based on the validated results, we analyzed highly rough-surface radioactive corrosion products and assessed their composition. Finally, the usefulness of the semi-quantitative analysis was reviewed by verifying the results of the analysis of radioactive corrosion products collected from spent nuclear fuel rods.

Polarization Spectral Imaging System for Quantitative Evaluation of Port Wine Stain Blanching Following Laser Treatment

  • Jung, Byung-Jo
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.234-239
    • /
    • 2003
  • Objective methods to assess quantitatively port wine stain (PWS) blanching in response to laser therapy are needed to improve laser therapeutic outcome. Previous studies have attempted to assess objectively PWS color based on point measurement devices. To date, these approaches have typically been limited by a number of factors such as small test area and need for contact. To address these issues, a polarization spectral imaging system and an image analysis method have been developed to evaluate quantitatively erythema and melanin content distribution in skin. The developed polarization spectral imaging system minimizes artifacts such as glaring, shadowing, and non-uniform illumination that interfere with image fidelity. Furthermore, the image analysis method has been employed to get images of skin melanin and erythema indices from the acquired color images for quantitative analysis. Finally, using PWS patient color image, the effectiveness in laser treatment of PWS was evaluated by calculating relative erythema index image that is the relative erythema index of PWS region to the normal region. The developed device and analysis method appears to be a simple and effective method for quantitative analysis of PWS blanching.

Development and Application of Image Analysis Program for Investigation of Pore Characteristics in Transverse Surface of Hardwoods

  • Kwon, Oh-Kyung;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.29-37
    • /
    • 1998
  • An image analysis program with the function of measuring various quantitative characteristics in the transverse surface of wood was developed using Delphi 2.0. Data on pore characteristics (conditions for image processing, proportion of pores in relationship to other elements, tangential diameter, area, tangential and radial diameter, x and y coordinates of pore center, and geometric coefficients) were saved in text file format. In addition, the pore area histogram in the tangential and radial directions was saved as a BMP (bitmap) type file. Analyses indicated that quantitative characteristics such as the relative radial distribution of pores in a growth ring, pore tangential area histogram, and proportion of pore in lumen area appear to be useful in separating four diffuse-porous woods and four ring-porous woods on the species level.

  • PDF

Quantitative Visualization of Mixed Convection in 3-D Rectangular Channels Using TLC Tracers (액정을 이용한 3차원 사각채널 내 혼합대류의 정량적 가시화)

  • Piao, Ri-Long;Kim, Jeong-Soo;Bae, Dae-Seok
    • Journal of Power System Engineering
    • /
    • v.20 no.6
    • /
    • pp.51-57
    • /
    • 2016
  • Experiment is carried out to investigate the mixed convective flow in three-dimensional horizontal rectangular channels filled with high viscous fluid. The particle image velocimetry(PIV) with thermo-sensitive liquid crystal tracers is used for visualizing and analysis. Quantitative data of temperature and velocity are obtained by applying the color-image processing to a visualized image, and neural network is applied to the color-to-temperature calibration. In this study, the fluid used is silicon oil(Pr=909), the aspect ratio(channel width to heigh) is 4 and Reynolds number is $2{\times}10^{-2}$. From the present study, we can visualize the quantitative temperature and velocity of mixed convective flow in three-dimensional horizontal rectangular channels simultaneously.

Quantitative Evaluation of Fabric Drape Using Image Analysis (화상처리기법을 활용한 천의 드레이프성의 정량적 평가방법)

  • Park, Chang-Kyu
    • Fashion & Textile Research Journal
    • /
    • v.4 no.3
    • /
    • pp.284-288
    • /
    • 2002
  • In this research, a new quantitative fabric drape evaluation system has been developed using image processing technology. The purpose of this research is to get the more detailed information of fabric drapability quantitatively from digital images captured with a digital camera generally commercialized. The shape parameters of a 3-dimensional geometric drape model were defined as the number of nodes, frequency and amplitude. Also, various statistical information of drape shapes can be obtained using image processing technology and frequency analysis as well as traditional drape coefficients. Hardware system to capture drape images is simply composed of three parts including a digital USB (Universal Serial Bus) camera, a frame cover and a stand for camera to attach to traditional drape tester. The evaluation software coded with the MS Visual C++ is operated under the MS windows 9x above.

Quantitative Assessment of Denticulus by Color Image Analysis (컬러 영상 분석을 통한 치석의 정량적 평가)

  • Shin, Seung-Won;Lee, Sun-Ju;Lee, Seong-Taek;Kim, Kyeong-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.129-130
    • /
    • 2008
  • In this study, we implement the color image processing algorithm to analyze the quantitative assessment of denticulus by computing spectral characteristics in HGB color domain. We can observe that we can utilize the normalized HGB color feature to assess the quantitative formation of denticulus.

  • PDF

Image Quality and Lesion Detectability of Lower-Dose Abdominopelvic CT Obtained Using Deep Learning Image Reconstruction

  • June Park;Jaeseung Shin;In Kyung Min;Heejin Bae;Yeo-Eun Kim;Yong Eun Chung
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.402-412
    • /
    • 2022
  • Objective: To evaluate the image quality and lesion detectability of lower-dose CT (LDCT) of the abdomen and pelvis obtained using a deep learning image reconstruction (DLIR) algorithm compared with those of standard-dose CT (SDCT) images. Materials and Methods: This retrospective study included 123 patients (mean age ± standard deviation, 63 ± 11 years; male:female, 70:53) who underwent contrast-enhanced abdominopelvic LDCT between May and August 2020 and had prior SDCT obtained using the same CT scanner within a year. LDCT images were reconstructed with hybrid iterative reconstruction (h-IR) and DLIR at medium and high strengths (DLIR-M and DLIR-H), while SDCT images were reconstructed with h-IR. For quantitative image quality analysis, image noise, signal-to-noise ratio, and contrast-to-noise ratio were measured in the liver, muscle, and aorta. Among the three different LDCT reconstruction algorithms, the one showing the smallest difference in quantitative parameters from those of SDCT images was selected for qualitative image quality analysis and lesion detectability evaluation. For qualitative analysis, overall image quality, image noise, image sharpness, image texture, and lesion conspicuity were graded using a 5-point scale by two radiologists. Observer performance in focal liver lesion detection was evaluated by comparing the jackknife free-response receiver operating characteristic figures-of-merit (FOM). Results: LDCT (35.1% dose reduction compared with SDCT) images obtained using DLIR-M showed similar quantitative measures to those of SDCT with h-IR images. All qualitative parameters of LDCT with DLIR-M images but image texture were similar to or significantly better than those of SDCT with h-IR images. The lesion detectability on LDCT with DLIR-M images was not significantly different from that of SDCT with h-IR images (reader-averaged FOM, 0.887 vs. 0.874, respectively; p = 0.581). Conclusion: Overall image quality and detectability of focal liver lesions is preserved in contrast-enhanced abdominopelvic LDCT obtained with DLIR-M relative to those in SDCT with h-IR.

A Method for Quantitative Measurement of Lateral Flow Immunoassay Using Color Camera (컬러 카메라를 이용한 측면유동 면역 어세이 정량분석 방법)

  • Park, Jongwon
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • Among semi-quantitative or fully quantitative lateral flow assay readers, an image sensor-based instrument has been widely used because of its simple setup, cheap sensor price, and compact equipment size. For all previous approaches, monochrome CCD or CMOS cameras were used for lateral flow assay imaging in which the overall intensities of all colors were taken into consideration to estimate the analyte content, although the analyte related color information is only limited to a narrow wavelength range. In the present work, we introduced a color CCD camera as a sensor and a color decomposition method to improve the sensitivity of the quantitative biosensor system which utilizes the lateral flow assay successfully. The proposed setup and image processing method were applied to achieve the quantification of imitatively dispensed particles on the surface of a porous membrane first, and the measurement result was then compared with that using a monochrome CCD. The compensation method was proposed in different illumination conditions. Eventually, the color decomposition method was introduced to the commercially available lateral flow immunochromatographic assay for the diagnosis of myocardial infarction. The measurement sensitivity utilizing the color image sensor is significantly improved since the slopes of the linear curve fit are enhanced from 0.0026 to 0.0040 and from 0.0802 to 0.1141 for myoglobin and creatine kinase (CK)-MB detection, respectively.