• Title/Summary/Keyword: quantitative evaluation method

Search Result 1,410, Processing Time 0.032 seconds

MR-based Partial Volume Correction for $^{18}$F-PET Data Using Hoffman Brain Phantom

  • Kim, D. H.;Kim, H. J.;H. K. Jeong;H. K. Son;W. S. Kang;H. Jung;S. I. Hong;M. Yun;Lee, J. D.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.322-323
    • /
    • 2002
  • Partial volume averaging effect of PET data influences on the accuracy of quantitative measurements of regional brain metabolism because spatial resolution of PET is limited. The purpose of this study was to evaluate the accuracy of partial volume correction carried out on $^{18}$ F-PET images using Hoffman brain phantom. $^{18}$ F-PET Hoffman phantom images were co-registered to MR slices of the same phantom. All the MR slices of the phantom were then segmented to be binary images. Each of these binary images was convolved in 2 dimensions with the spatial resolution of the PET. The original PET images were then divided by the smoothed binary images in slice-by-slice, voxel-by-voxel basis resulting in larger PET image volume in size. This enlarged partial volume corrected PET image volume was multiplied by original binary image volume to exclude extracortical region. The evaluation of partial volume corrected PET image volume was performed by region of interests (ROI) analysis applying ROIs, which were drawn on cortical regions of the original MR image slices, to corrected and original PET image volume. From the ROI analysis, range of regional mean values increases of partial volume corrected PET images was 4 to 14%, and average increase for all the ROIs was about 10% in this phantom study. Hoffman brain phantom study was useful for the objective evaluation of the partial volume correction method. This MR-based correction method would be applicable to patients in the. quantitative analysis of FDG-PET studies.

  • PDF

Evaluation of the Noise Power Spectrum by Using American College of Radiology Phantom for Magnetic Resonance Imaging (자기공명영상에서 ACR 팬텀을 이용한 잡음전력스펙트럼 평가)

  • Jung-Whan Min;Hoi-Woun Jeong
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.21-28
    • /
    • 2024
  • This study was purpose to quantitative evaluation of comparison of the image intensity uniformity and noise power spectrum (NPS) by using American college of radiology (ACR) phantom for magnetic resonance imaging (MRI). The MRI was used achiva 3.0T MRI and discovery MR 750, 3.0T, the head and neck matrix shim SENSE head coil were 32 channels receive MR coil. The MRI was used parameters of image sequence for ACR standard and general hospital. NPS value of the ACR standard T2 vertical image in GE equipment was 7.65E-06 when the frequency was 1.0 mm-1. And the NPS value of the ACR hospital T1 region of interest (ROI) 9 over all vertical image in Philips equipment was 9E-08 when the frequency was 1.0 mm-1 and the NPS value of the hospital T2 ROI 9 over all vertical image in Philips equipment was 1.06E-07 when the frequency was 1.0 mm-1. NPS was used efficiently by using a general hospital vertical sequence more than the standard vertical sequence method by using the ACR phantom. Furthermore NPS was the quantitative quality assurance (QA) assessment method for noise and image intensity uniformity characteristics was applied mutatis mutandis, and the results values of the physical imaging NPS of the 3.0T MRI and ACR phantom were presented.

Evaluation Method of Bonded Strength in Adhesively Bonded Structures of the Aluminum Alloys (알루미늄 합금의 접착구조물에 대한 접착강도의 평가방법)

  • 정남용
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.1
    • /
    • pp.35-44
    • /
    • 1999
  • In a view point of earth environmental protection and social requirement, adhesively bonded structures of aluminum alloys have become to be employed for the purpose of decreasing fuel ratio by weight reduction and to improve performance in various engineering fields such as aircrafts, automobiles, rolling stocks and so on. In spite of such wide applications in adhesively bonded structures of aluminum alloys, the quantitative fracture criterion and evolution method of its bonded strength have not been established yet. The objective of this paper is to establish fracture criterion considering stress singularity at interface edges in adhesively bonded structures of aluminum alloys. Through the analyses of boundary element method and static fracture experiments with three different types of specimens in the adhesively bonded joints of aluminum alloys, its fracture criterion was proposed and discussed about strength evolution of adhesively bonded structures.

  • PDF

A Method for Generating Large-Interval Itemset using Locality of Data (데이터의 지역성을 이용한 빈발구간 항목집합 생성방법)

  • 박원환;박두순
    • Journal of Korea Multimedia Society
    • /
    • v.4 no.5
    • /
    • pp.465-475
    • /
    • 2001
  • Recent1y, there is growing attention on the researches of inducing association rules from large volume of database. One of them is the method that can be applied to quantitative attribute data. This paper presents a new method for generating large-interval itemsets, which uses locality for partitioning the range of data. This method can minimize the loss of data-inherent characteristics by generating denser large-interval items than other methods. Performance evaluation results show that our new approach is more efficient than previously proposed techniques.

  • PDF

Analyses of Fracture Parameters and Prediction of Crack Propagation Path on Delamination in the LSI Package (반도체 패키지의 층간박리 파괴역학인자 해석 및 균열진전경로 예측)

  • Chung, Nam-Yong;Park, Cheol-Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.4
    • /
    • pp.401-409
    • /
    • 2009
  • This paper presents a method of calculating the stress intensity factor (K) and crack propagation direction (${\theta}_0$) at the crack-tip that is associated with delamination in the large scale integration(LSI) package. To establish a reasonable strength evaluation method and life prediction, it is necessary to assess fracture parameters under various fracture conditions. Therefore, we conducted quantitative stress singularity analysis considering thermal stress simulating the changes of crack length (a), (h) and (v) in delamination using the 2-dimensional elastic boundary element method (BEM), and from these results predicted crack propagation direction and path.

  • PDF

Establishment of Fracture Criterion on Friction Welded Dissimilar Materials (이종 마찰용접재의 파괴기준 설정)

  • Chung, Nam-Yong;Park, Cheol-Hee
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.5
    • /
    • pp.164-171
    • /
    • 2006
  • Application of friction welding is increasing in the manufacturing process of machine elements in many industry fields. To establish a reasonable strength evaluation method and fracture criterion, it is necessary to analyze stress singularity under the residual stress condition on friction welded interface between dissimilar materials. In this paper, a method to establish fracture criterion on interface of friction welded dissimiliar materials was investigated by using the boundary element method BEM and static tensile testing. A quantitative fracture criterion for friction welded dissimilar materials is suggested by using stress singularity factor, $\Gamma$.

Quantification of Allantoin in Yams (Dioscorea sp.) Using a 1H NMR Spectroscopic Method

  • Thao Quyen Cao;Dongyup Hahn
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.5
    • /
    • pp.662-667
    • /
    • 2023
  • Allantoin is an abundant component of yams and has been known as a skin protectant due to its pharmacological activities. In previous methods for allantoin determination using high-performance liquid chromatography (HPLC), the separation was unsatisfactory. We herein developed a 1H quantitative nuclear magnetic resonance (qNMR) method for quantification of allantoin in the flesh and peel of yams. The method was carried out based on the relative ratio of signals integration of allantoin to a certain amount of the internal standard dimethyl sulfone (DMSO2) and validated in terms of specificity, linearity (range 62.5-2000 ㎍/ml), sensitivity (limit of detection (LOD) and quantification (LOQ) 4.63 and 14.03 ㎍/ml, respectively), precision (RSD% 0.02-0.26), and recovery (86.35-92.11%). The method was then applied for the evaluation of allantoin in flesh and peel extracts of four different yams cultivated in Korea.

Development of Quality Control Method for a Novel Herbal Medicine, HPL-1 using UHPLC (UHPLC를 이용한 새로운 한약제제 HPL-1의 품질관리법 개발)

  • Kim, Se-Gun;Lamichhane, Ramakanta;Lee, Kyung-Hee;Jung, Hyun-Ju
    • The Korea Journal of Herbology
    • /
    • v.30 no.3
    • /
    • pp.19-24
    • /
    • 2015
  • Objectives : HPL-1, a novel herbal medicine which is composed of five herbs such as Kalopanacis Cortex, Chaenomelis Fructus, Raphani Semen, Atractylodis Rhizoma and Pulvis Aconiti Tuberis Purificatum, was developed for treatment of osteoarthritis. This study is aimed to develop analytical method for consistent quality control of HPL-1 and validate chromatographic method. Methods : Chromatographic analysis was performed using ultra-high performance liquid chromatography - diode array detector (UHPLC-DAD) equipped with RP-amide column, column oven, and auto sampler. Marker compounds [protocatechuic acid, chlorogenic acid, liriodendrin, 3,5-dicaffeoylquinic acid, ${\beta}$-D-(3-O-sinapoyl)-fructofuranosyl-$\alpha$-D-(6-O-sinapoyl)glucopyranoside and benzoylmesaconine] were separated by step gradient elution of acetonitrile and 0.1% phosphoric acid/water. The method validation was evaluated by quantitative validation parameters of linearity, accuracy, precision, limit of detection (LOD) and limit of quantification (LOQ) according to KFDA guideline.Results : An optimized method for six marker compounds in HPL-1 was established by UHPLC-DAD. The correlation coefficient (R2) with each calibration curve was greater than 0.99. The LOD and LOQ were within the range of 0.008-0.090 and $0.023-0.274{\mu}g/mL$, respectively. The relative standard deviation (RSD) of intra- and inter-day variability were less than 4.0%. The result of recovery test was range from 93.3-106.3% with RSD < 4.0%.Conclusions : These results suggest that the quantitative UHPLC method is precise, accurate, effective for quality evaluation of HPL-1. The method may also contribute to improve quality of crude drug preparations used for treatment of various diseases.

Quantitative evaluation of midpalatal suture maturation via fractal analysis

  • Kwak, Kyoung Ho;Kim, Seong Sik;Kim, Yong-Il;Kim, Yong-Deok
    • The korean journal of orthodontics
    • /
    • v.46 no.5
    • /
    • pp.323-330
    • /
    • 2016
  • Objective: The purpose of this study was to determine whether the results of fractal analysis can be used as criteria for midpalatal suture maturation evaluation. Methods: The study included 131 subjects aged over 18 years of age (range 18.1-53.4 years) who underwent cone-beam computed tomography. Skeletonized images of the midpalatal suture were obtained via image processing software and used to calculate fractal dimensions. Correlations between maturation stage and fractal dimensions were calculated using Spearman's correlation coefficient. Optimal fractal dimension cut-off values were determined using a receiver operating characteristic curve. Results: The distribution of maturation stages of the midpalatal suture according to the cervical vertebrae maturation index was highly variable, and there was a strong negative correlation between maturation stage and fractal dimension (-0.623, p < 0.001). Fractal dimension was a statistically significant indicator of dichotomous results with regard to maturation stage (area under curve = 0.794, p < 0.001). A test in which fractal dimension was used to predict the resulting variable that splits maturation stages into ABC and D or E yielded an optimal fractal dimension cut-off value of 1.0235. Conclusions: There was a strong negative correlation between fractal dimension and midpalatal suture maturation. Fractal analysis is an objective quantitative method, and therefore we suggest that it may be useful for the evaluation of midpalatal suture maturation.

Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging (초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가)

  • Jung-Whan, Min;Hoi-Woun, Jeong;Hea-Kyung, Kang
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.