• Title/Summary/Keyword: quantitative characteristic

검색결과 464건 처리시간 0.029초

A NOTE ON THE VALUE DISTRIBUTION OF DIFFERENTIAL POLYNOMIALS

  • Bhoosnurmath, Subhas S.;Chakraborty, Bikash;Srivastava, Hari M.
    • 대한수학회논문집
    • /
    • 제34권4호
    • /
    • pp.1145-1155
    • /
    • 2019
  • Let f be a transcendental meromorphic function, defined in the complex plane $\mathbb{C}$. In this paper, we give a quantitative estimations of the characteristic function T(r, f) in terms of the counting function of a homogeneous differential polynomial generated by f. Our result improves and generalizes some recent results.

유압구동 부재의 마찰 상태 식별에 관한 연구 (Study of Identification of Lubricant Condition for Hydraulic Member)

  • 강인혁;류미라;박재상;박흥식
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 제35회 춘계학술대회
    • /
    • pp.193-199
    • /
    • 2002
  • Analyzing working conditions with shape characteristics of wear debris in a lubricated machine, it can be effect on diagnosis of hydraulic machining system. And it can be recognized that results are processed threshold images of wear debris. But, in order to predict and estimate a working condition of lubricated machine, it is need to analysis a shape characteristic of wear debris and to identify. Therefor, If shape characteristics of wear debris are identified by computer image analysis and the neural network, it is possible to find the cause and effect of wear condition. In this stud)r, wear debris in the lubricant oil are extracted by membrane filter $(0.45{\mu}m)$, and the quantitative value of shape characteristic of wear debris are calculated by the digital image processing. This morphological information are studied and identified by tile artificial neural network. The purpose of this study is to apply morphological characteristic of wear debris to prediction and estimation of working condition in hydraulic machining systems.

  • PDF

다중코일 와전류 센서 설계제작 및 특성분석 (The Design & Manufacture of Multi-coil Eddy Current Sensor and Characteristic Analysis)

  • 안연식;길두송;박상기
    • 동력기계공학회지
    • /
    • 제15권3호
    • /
    • pp.65-69
    • /
    • 2011
  • This paper introduces the multi-coil eddy current sensor and its characteristic in magnetic material gas turbine rotor. In the past, magnetic particle inspection method was used for qualitative defect evaluation in magnetic material gas turbine rotor. And the ultrasonic inspection method was used for quantitative defect evaluation. Nowadays, eddy current method is used in magnetic gas turbine rotor inspection due to advanced sensor design technology. We developed multi-coil eddy current sensor for the rotor dovetail inspection. At first, rotor stress is analyzed for the determination of sensor position and number. The sensor coils are designed to cover the stress concentration area of rotor dovetail. We select optimum frequency according to material standard penetration data and experiment results. The rotor mock-up and artificial defects were made for the signal detection and resolution analysis of multi-coil eddy current sensor. The results show that signal detection and resolution capabilities are enhanced in comparison to the commercialized sensor enough for the gas turbine rotor inspection. So, this developed multi-coil eddy current sensor substituted for commercialized one and it applied in real gas turbine rotor inspection.

볼트 홀 결함 평가용 와전류 센서 설계제작 및 특성분석 (The Design & Manufacture and Characteristic Analysis of Eddy Current Sensor for Bolt Hole Defect Evaluation)

  • 안연식;길두송;박상기
    • 동력기계공학회지
    • /
    • 제15권4호
    • /
    • pp.37-41
    • /
    • 2011
  • This paper introduces the special eddy current sensor and its characteristic for bolt hole defect evaluation in gas turbine rotor. In the past, Fluorescent penetration inspection method was used for qualitative defect evaluation in gas turbine rotor bolt hole. This method can defect the bolt hole defect but can not evaluate the defect size. Nowadays, eddy current method is used quantitative defect evaluation due to advanced sensor design technology. And eddy current method is more time and cost saving than the old method. We developed bolt shape eddy current sensor for the rotor bolt hole defect detection and evaluation. The eddy current sensor moves to the bolt hole guided by screw nut and detects the defect on the bolt hole. The bolt hole mock-up and artificial defects were made and used for the signal detection & resolution analysis of eddy current sensor. The results show that signal detection capability is enough to detect 0.2 mm depth defect. And the resolution capability is enough to differentiate 02, 0.5, 1.0 and 2.0 mm depth defect.

피부과 의원의 실내디자인 특성에 관한 연구 (A Study on the Interior Design Characteristic of Skin Clinic)

  • 윤갑근;김양지;문희정
    • 한국실내디자인학회논문집
    • /
    • 제13권4호
    • /
    • pp.110-117
    • /
    • 2004
  • Recently the hospitals or clinics tend to get out of the functional and technological aspect so as to gradually emphasize service for patients. While qualitative rather than quantitative alteration is noticeable, the scale of clinics is getting larger. Especially, the opulence resulted from economic, social and cultural development has enabled more people to visit dermatology or plastic surgery besides treatment for disease. Responding to this tendency, dermatology is focusing on skin beauty, plastic operation, controlling obesity, etc. for women rather than ordinary treatment. Thus, dermatology is in need of space for skin control as well as ordinary treatment, which raises the immediate necessity of new plan for space and interior environment. In order to meet such necessity of dermatology, it is required to fully study and consider the plan for interior space. First, the purpose, scope and method of research will be defined in the introduction. Second, the concept of clinic as well at the characteristic of dermatology will be studied by theoretical investigation. Third, the general concept of dermatology will be analyzed by examining the characteristic of each room in dermatology, the moving line of nurses and patients, the color of dermatology and the design factor of finishing materials through general investigation on dermatology. Fourth, in order to look into the general case of dermatology, the object of examination will be selected for examination through literature and visiting. After examining data, the result will be analyzed and evaluated to prepare the ground for interior plan of dermatology.

군사용 밀폐공간내의 화재시 단일 증발액적에 의한 방재특성 연구 (The study of a fire fighting characteristic by a Single Evaporating Droplet in the case of a fire of military enclosure space)

  • 이진호;방창훈;김정수
    • 한국군사과학기술학회지
    • /
    • 제3권1호
    • /
    • pp.207-217
    • /
    • 2000
  • A fire fighting characteristic by a single evaporating droplet in the case of a fire of military enclosure space was studied experimentally. Transient cooling of solid surface by water droplet evaporation has been investigated through controlled experiments using a heated brass cylinder. Quantitative predictions of droplet evaporation time and in-depth transient temperature distribution in solid have been made. The particular interest was in the removal of thermal energy from the heated cylinder by evaporative cooling. A $10{\mu}1$ single droplet is deposited on a horizontal brass surface with initial temperatures in the range of $90^{\circ}C{\sim}130^{\circ}C.$ The results can be summarized as follows; Evaporating droplet was divided into three different configuration. Evaporation time was predicted as a function of initial surface temperature ($t_c=492.62-6.89T_{s0}+0.0248T_{s0}^2).$ The contact temperature was predicted as a function of initial surface temperature( $T_{i}$=0.94 $T_{s0}$+1.4), The parameter ${\beta}_o$ was predicted as a function of initial surface temperature( ${\beta}_0$ : 0.O0312 $T_{s0}+0.932$)>)>)

  • PDF

도시철도차량 시트의 안락성 평가 및 분석 (The comfort evaluation and analysis of the urban rail vehicle)

  • 구재광;서우성;최세화
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.222-228
    • /
    • 2007
  • In order to solve the problem of traffic holdups and environmental pollution(contamination), several metropolises are operating the subway and many local government plans hereafter the light rail vehicle operation and it is in the process of preparing. This point of time, it need to evaluate the comfortable characteristic of the seat which is closely connected with passenger and it should be reflected to the product design through the data analysis. The methods of the comfortable characteristic evaluation should be considered to various methods from physical factor to psychological factor. Among these, the most universal and possible quantitative measurement estimate through 'Body pressure measurement system'. From this paper, it was measured the body pressure of the subway seat which is in the process of operating in a domestic and it will be compared and analyzed the material & seat shape, so we evaluated the comfortable characteristic of the short-distance transportation railway vehicle. It was operated the man and woman who belongs in standard shape of Korean, we compared and analyzed the Peak position where the body pressure is visible and body pressure spread out.

  • PDF

Assessment of the Severity of Coronavirus Disease: Quantitative Computed Tomography Parameters versus Semiquantitative Visual Score

  • Xi Yin;Xiangde Min;Yan Nan;Zhaoyan Feng;Basen Li;Wei Cai;Xiaoqing Xi;Liang Wang
    • Korean Journal of Radiology
    • /
    • 제21권8호
    • /
    • pp.998-1006
    • /
    • 2020
  • Objective: To compare the accuracies of quantitative computed tomography (CT) parameters and semiquantitative visual score in evaluating clinical classification of severity of coronavirus disease (COVID-19). Materials and Methods: We retrospectively enrolled 187 patients with COVID-19 treated at Tongji Hospital of Tongji Medical College from February 15, 2020, to February 29, 2020. Demographic data, imaging characteristics, and clinical data were collected, and based on the clinical classification of severity, patients were divided into groups 1 (mild) and 2 (severe/critical). A semiquantitative visual score was used to estimate the lesion extent. A three-dimensional slicer was used to precisely quantify the volume and CT value of the lung and lesions. Correlation coefficients of the quantitative CT parameters, semiquantitative visual score, and clinical classification were calculated using Spearman's correlation. A receiver operating characteristic curve was used to compare the accuracies of quantitative and semi-quantitative methods. Results: There were 59 patients in group 1 and 128 patients in group 2. The mean age and sex distribution of the two groups were not significantly different. The lesions were primarily located in the subpleural area. Compared to group 1, group 2 had larger values for all volume-dependent parameters (p < 0.001). The percentage of lesions had the strongest correlation with disease severity with a correlation coefficient of 0.495. In comparison, the correlation coefficient of semiquantitative score was 0.349. To classify the severity of COVID-19, area under the curve of the percentage of lesions was the highest (0.807; 95% confidence interval, 0.744-0.861: p < 0.001) and that of the quantitative CT parameters was significantly higher than that of the semiquantitative visual score (p = 0.001). Conclusion: The classification accuracy of quantitative CT parameters was significantly superior to that of semiquantitative visual score in terms of evaluating the severity of COVID-19.

Analysis and Specifications of Switching Frequency in Parallel Active Power Filters Regarding Compensation Characteristics

  • Guopeng, Zhao;Jinjun, Liu
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.749-761
    • /
    • 2010
  • The switching frequency of a power device is a very important parameter in the design of a parallel active power filter (PAPF), but so far, very little discussion has been conducted on it in a quantitative manner in previous publications. In this paper, an extensive analysis on the effects of the switching frequency on the performance of a PAPF is made, and a specification of the switching frequency values with different compensation results is presented. A first-order inertia element and a second-order oscillation element are considered as approximate models of a PAPF, respectively. The compensation characteristic for each order of harmonic current is obtained at different switching frequencies. Then, the THDs of each model for the system loads of a rectifier with resistance and inductance loads are proposed. The compensation results of a PAPF controlled as a first-order inertia element are better than those of a PAPF controlled as a second-order oscillation element. With two types of system loads which are rectifier with resistance and inductance loads and rectifier with resistance, inductance and capacitance loads, the THDs of the source current after compensation are presented with different switching frequencies. The compensation characteristics for the most widely used digital control system are investigated. The situation with an analog control is the theoretical characteristic and it is the best situation. The compensation characteristic of the digital control is worse than the compensation characteristic of the theoretical characteristic. Based on these analyses, the specifications of compensation characteristics with different switching frequencies are quite straightforward. Finally, a practical design example is studied to verify the application.

한국과 중국 인삼자원들의 양적 형질 특성과 유전적 유연관계 분석 (Comparative Analysis of Genetic Relationships by Quantitative Characters and Their Characteristics in Germplasm of Panax ginseng C. A. Meyer Collected in Korea and China)

  • 송범헌;오문국;김도현;정종욱
    • 한국약용작물학회지
    • /
    • 제25권6호
    • /
    • pp.381-388
    • /
    • 2017
  • Background: This study was conducted to acquire basic information on the phenotypic and genotypic characteristics of the germplasm of Panax ginseng C. A. Meyer collected from China and Korea, and identify the variations that can be utilized in ginseng breeding programs. Methods and Results: Quantitative parameters were evaluated, and used to compare and analyze on genetic polymorphisms in the germplasm. The genetic characteristics and classifications were compared and analyzed for each character. Stem length followed a normal frequency distribution ranging from 15.5 cm to 40.5 cm, with showing approximately 40% having a stem length of 20 - 30 mm. Stem diameters ranged from 2.7 mm to 11.3 mm. Stem number per plant ranged from 1 to 3; approximately 50% had a single stem, and 45% had two stems. A non-normal frequency distribution was observed for petiole number, with approximately 60% of the germplasm having 3 - 5 petioles. Petiole length exhibited a normal frequency distribution, raging from 4.5 to 10.6. Petiole angle in the germplasm ranged from $28^{\circ}$ to $89^{\circ}$ and seedstalk length ranged from 5.6 cm to 27.3 cm. Conclusions: The genetic polymorphisms identified by complete linkage clustering based on the quantitative characteristics of Panax ginseng C. A. Meyer collected from Korea and China were classified to 6 groups, namely I, II, III, IV, V, and VI with frequencies of 6.7%, 20.0%, 31.7%, 8.3%, 6.7%, and 26.7%, respectively.