• Title/Summary/Keyword: quality measurement tool

Search Result 342, Processing Time 0.023 seconds

A Study on the Fabrication and Comparison of the Phantom for Computed Tomography Image Quality Measurements Using Three-Dimensions Printing Technology (삼차원 프린팅 기술을 이용한 전산화단층영상 품질 측정용 팬텀 제작 및 비교 연구)

  • Yoon, Myeong-Seong;Hong, Soon-Min;Heo, Yeong-Cheol;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.595-602
    • /
    • 2018
  • Quality control (QC) of Computed Tomography (CT) devices is based on image quality measurement on AAPM CT phantom which is a standard phantom. Although it is possible to control the accuracy of the CT apparatus, it is expensive and has a disadvantage of low penetration rate. Therefore, in this study, we make image quality measurement phantom at low cost using FFF (Fused Filament Fabrication) type three-dimensional printer and try to analyze the usefulness, compare it with existing standard phantom. To print a phantom, We used three-dimensional printer of the FFF system and PLA (Poly Lactic Acid, density: $1.24g/cm^3$) filament, and the CT device of 64 MDCT (Aquilion CX, Toshiba, Japan). In addition, we printed a phantom using three-dimensional printer after design using various tool based on existing standard phantom. For image quality evaluation, AAPM CT phantom and self-generated phantom were measured 10 times for each block. The measured data were analyzed for significance using the Mannwhiteney U-test of SPSS (Version 22.0, SPSS, Chicago, IL, USA). As a result of the analysis, phantom fabricated with three-dimensional printer and standard phantom showed no significant difference (p>0.05). Furthermore, we confirmed that image quality measurement performance of a phantom using three-dimensional printer is similar to the existing standard phantom. In conclusion, we confirmed the possibility of low cost phantom fabrication using three dimensional printer.

Development of CAM system for 5-axis automatic roughing machine Based on Reverse Engineering (역공학 기반 5축 신발 러핑용 CAM 시스템 개발)

  • Kim Hwa Young;Son Seong Min;Ahn Jung Hwan;Kang Dong Bae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.7 s.172
    • /
    • pp.122-129
    • /
    • 2005
  • Shoe with leather upper such as safety and golf shoe requires a roughing process where the upper is roughed fur helping outsole to be cemented well. It is an important and basic process for production of leather shoe but is not automated yet. Thus, there are problems that the defect rate is high and the quality of roughed surface is not uniform. In order to solve such problems, the interest in automation of roughing process is being increased and this paper introduces CAM system for 5-axis automatic roughing machine as one part of automation of roughing process. The CAM system developed interpolates a B-spline curve using points measured from the Roughing Path Measurement System. The B-spline curve is used to generate the tool path and orientation data fer a roughing tool which has not only stiffness but also flexibility to rough the inclined surface efficiently. For productivity, the upper of shoe is machined by side of the roughing tool and tool offset is applied to the roughing tool for machining of inclined surface. The generated NC code was applied to 5-axis polishing machine for the test. The upper of shoe was roughed well along the roughing path data from CAM and the roughed surface was proper fur cementing of the outsole.

Study of photon beam quality tool at magnetic field change in bending magnet (편향전자석의 자장변화에 따른 광자선 선질평가에 관한 고찰)

  • Kim, Jeong-Ho;Yoo, Se-Jong;Park, Myeong-Cheol;Bae, Seok-Hwan;Kim, Ki-Jin
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.433-439
    • /
    • 2014
  • Beam quality is changed about magnetic field of bending magnet. Evaluation of beam quality using PDD(Percentage Depth Dose) at 10cm depth at recommendation of AAPM(America Academy of Pain Medicine). However this evaluation shows fragmentary element. Therefore this study is applied to three value, 10cm divided by 5cm depth PDD, 20cm divided by 10cm depth PDD, 30cm divided by 20cm depth PDD, at change the magnetic field. PDD is measured at magnetic field changed ${\pm}1%$, ${\pm}2%$ at 6MV(Mega Voltage), 10MV photon. The plan technique is 3 portal plan using Core-Plan at human pelvic phantom. Conventional and presented methods are compared at maximum and minimum dose. The presented method increased discernment of relieve the unequal distribution and energy area than conventional method. Henceforth, application of presented method will be considered. Development of energy measurement method and detector miniaturization will be needed about continuous study.

Contact Force Estimation for a Polishing Brush (연마 브러시 접촉력 산출)

  • Lee, Byoung-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.1
    • /
    • pp.58-63
    • /
    • 2010
  • A new contact force estimation technique is proposed. Keeping the contact force at a certain level between finishing tool and the object is essential since the quality of the finished surface is very sensitive to the contact force during the finishing process. However, the contact force measurement cannot be obtained by simply installing load cells under machine table or in the middle of tool linkage. The reason is that the weight of the machine table and the tool linkage are much heavier than the force to be measured. To that end, a method for estimating disturbance is proposed for a system that is similar to the mechanism of the finishing machine, and the same method is applied to estimate the contact force of the brush-type finishing machine. To verify the effectiveness of the proposed method, a small scale test set-up has been built and the method has been tested.

The Tectonic Characteristics of ′KAN′ in the head residence of Uisong Kims (의성 김씨종택에 있어서 간의 건축적 특성)

  • 장선주;이강훈
    • Journal of the Korean housing association
    • /
    • v.15 no.3
    • /
    • pp.11-19
    • /
    • 2004
  • The purpose of this study is to explain the tectonic characteristics of 'Kan' which is an unit of composition in the head residence of Uisong Kims. Here, the 'Kan' is assumed as a conceptual framework to organize a house and also a maneuvering tool to control the spatial order with relationship between the whole and the part. Not limited to the simple conceptual aspects, but the interrelated elements such as the site conditions, modules, functions, structure and aesthetic factors. Through the process of the study, the role of 'Kan' is proved to be a tectonic tool for self-regulating architectural order by relation matrix of elements. 'Kan' is not only a fixed measuring tool for functions and material of a house but also a flexible device to control the building composition. 'Kan' is certainly a relative subject for measurement of form, space and aesthetic quality.

A Study on Quality Control and Measurement for Acquisition of Dynamic Friction Coefficient on Back-hand Skin (손등피부의 운동마찰계수 획득을 위한 컨트롤 요소 및 측정에 관한 연구)

  • Lee, Jae-Hoon;Song, Han-Wook;Park, Yon-Kyu;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.3
    • /
    • pp.103-111
    • /
    • 2008
  • Recently, skin diagnosis has been suggested as a promising tool for discrimination of Sasang Constitution, reported by examining the skin characteristics such as thickness, stiffness, slip, and skin textures like wrinkles and furrows. However, the works had a limitation in that clinical decision on the skin characteristics was made by relying upon oriental medicine doctors' subjective sense of touch. In order to objectify the skin diagnosis and claim its efficacy on the discrimination of the Sasang Constitutions, it is necessary to demonstrate its discrimination capability by providing numerical values in terms of physical quantities obtained from measurements using today's sensors and equipment technologies, which motivated this work as a priliminary step towards objectification of skin diagnosis. The skin characteristics focused in this work is the slip property of the back-hand skin that has been exploited using the dynamic friction measurement system. First, curved geometric effects of the back-hand skin on the measured lateral/vertical force signals were estimated using the artificially designed silicon coated structures, which led to a suggestion on a quality controlled experimental design based upon a empirical analysis model. Second, the experimental design thus suggested has been applied to the measurement of dynamic friction coefficients for two healthy male subjects of Taeumin (TE) and Soyangin (SY), respectively. The result shows that the dynamic friction coefficient is less for the SY subject than for the TE subject around the area of the skin used for diagnosis by the oriental medicine doctor, implying the TE subject's skin is more slippery than the SE subject's that is consistent with the oriental medicine doctor's diagnosis. Hopefully, this work can provide guidelines for obtaining quality data in friction measurement to be collected for discussion on the efficacy of the skin diagnosis and its objectification through statistical analysis.

  • PDF

Modern Paper Quality Control

  • Komppa, Olavi
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.5
    • /
    • pp.72-79
    • /
    • 2000
  • On the other hand, the fiber orientation at the surface and middle layer of the sheet controls the bending stiffness of paperboard. Therefore, a reliable measurement of paper surface fiber orientation gives us a magnificent tool to investigate and predict paper curling and cockling tendency, and provides the necessary information to fine-tune the manufacturing process for optimum quality. Many papers, especially heavily calendered and coated grades, do resist liquid and gas penetration very much, being beyond the measurement range of the traditional instruments or resulting inconveniently long measuring time per sample. The increased surface hardness and use of filler minerals and mechanical pulp make a reliable, non-leaking sample contact to the measurement head a challenge of its own. Paper surface coating causes, as expected, a layer which has completely different permeability characteristics compared to the other layers of the sheet. The latest developments in sensor technologies have made it possible to reliably measure gas flow n well controlled conditions, allowing us to investigate the gas penetration of open structures, such as cigarette paper, tissue or sack paper, and in the low permeability range analyze even fully greaseproof papers, silicon papers, heavily coated papers and boards or even detect defects in barrier coatings! Even nitrogen or helium may be used as the gas, giving us completely new possibilities to rank the products or to find correlation to critical process or converting parameters. All the modern paper machines include many on-line measuring instruments which are used to give the necessary information for automatic process control systems. Hence, the reliability of this information obtained from different sensors is vital for good optimizing and process stability. If any of these on-line sensors do not operate perfectly as planned (having even small measurement error or malfunction), the process control will set the machine to operate away from the optimum, resulting loss of profit or eventual problems in quality or runnability. To assure optimum operation of the paper machines, a novel quality assurance policy for the on-line measurements has been developed, including control procedures utilizing traceable, accredited standards for the best reliability and performance.

  • PDF

Development of Framework for Effectiveness Measurement of LVC Synthetic Battlefield Training System (LVC 합성전장 훈련체계 효과도 측정 프레임워크 개발)

  • Kwon, Kybeom;Min, Seungin;Yee, Kwanjung;Seol, Hyeonju;Oh, Jihyun;Sim, Inbo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.704-713
    • /
    • 2018
  • The purpose of this study is to develop a systematic framework that can scientifically and quantitatively evaluate the effectiveness of an LVC training system. The proposed framework is based on QFD(Quality Function Development) methodology. The process of developing the framework begins with identifying various needs of stakeholders related to the introduction of the LVC training system. Then the effectiveness areas and factors are derived based on the needs. The measured effectiveness for each factors on alternatives by L, V, C systems are finally synthesized into the one overall effectiveness of each training system for relative comparison among them. In addition, we developed an Excel$^{TM}$-based tool based on the proposed framework methodology to provide an ease-of-use environment for rapid evaluation on the effectiveness of each training system with the given stakeholder need importance combinations, training scenarios and assets. The suggested framework and the measurement tool are expected to be useful for efficient knowledge-based decision making on an acquisition of the LVC training system.

Customized Pattern-Recognition Technique using Vision Measurement System Development in New Car Manufacturing Process (패턴인식 기법을 적용한 신차 제조공정 맞춤식 비젼 계측시스템 개발)

  • Lee, Gyung-Il;Kim, Jae-yeol;Roh, Chi-sung;Choi, Choul Jun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.4
    • /
    • pp.51-59
    • /
    • 2016
  • Measurements of the automobile manufacturers are available anywhere and anytime, directly based on the criterion of failure is measured. The maintenance of high-precision production activities is direct evidence of the fact that competitive manufacturing activities are very important in determining the success of companies to recall defective starting from raw material costs. The current manufacturing sites produce calipers and clearance gauge the degree of tool only specific. Therefore, judging the quality, including the number of errors, requires a lot of attention to the dimension failures in day-to-day measurements and measurement tasks and duties repeated in difficult situations. In this paper, we aim to develop a vehicle manufacturing plant site using each of the manufacturing processes while operating a measurement tool. We display it using the Image Processing PC-based S/W with all those visual facts by management and recorded as image information a more accurate and current situation to obtain information and share visual measurements. We carry out research on the design and development vision inspection algorithm applied for pattern-recognition techniques that can help manufacturing site quality control.

A Study on the Service Quality Assessment Utilizing 6 Sigma - Focused on Domestic Banks - (6 시그마를 활용한 서비스품질 평가에 관한 연구 - 국내 은행을 중심으로 -)

  • Kim, Jong-Hoon;Song, Gwang-Suk;Yoo, Han-Joo
    • Journal of Korean Society for Quality Management
    • /
    • v.39 no.4
    • /
    • pp.527-542
    • /
    • 2011
  • The importance of service industry in national economy is getting increasing due to current trend of aging society and increasingly desire for better quality of life. However, the level of labor productivity in domestic service industry is lower than Japan and Germany that are typically strong in manufacturing industry. Difficulty of process control and measurement in accordance with variability and intangibility which are features of service industry, is considered as the cause of this poor labor productivity in Korea. This study aims to present managerial implications by calculating sigma levels on branch bank service quality and suggesting the quality dimensions of banks can be checked through a gap comparison between the sigma level on service quality in the whole banks and service quality in each bank. Quality level presented by the KS-SQI is applied to the measurement method that Yoo Han Joo and Song Kwang Seok suggested in 2006. Spss18.0 is used as an analysis tool. As a result of factorial analysis, 7 dimensions of service quality in KS-SQI can be divided into new 3 dimensions of service quality. This study also suggests that width and number of questions in previous questionnaire shall be extended. The whole of the bank service quality level is evaluated 3 sigma. The research help banks to figure out their service quality level through gap comparison objectively.