• 제목/요약/키워드: quadratic curve

검색결과 177건 처리시간 0.021초

실험적 연구를 통한 비정형롤판재성형 예측 모델 개발 (Development of Prediction Model for Flexibly-reconfigurable Roll Forming based on Experimental Study)

  • 박지우;길민규;윤준석;강범수;이경훈
    • 소성∙가공
    • /
    • 제26권6호
    • /
    • pp.341-347
    • /
    • 2017
  • Flexibly-reconfigurable roll forming (FRRF) is a novel sheet metal forming technology conducive to produce multi-curvature surfaces by controlling strain distribution along longitudinal direction. Reconfigurable rollers could be arranged to implement a kind of punch die set. By utilizing these reconfigurable rollers, desired curved surface can be formed. In FRRF process, three-dimensional surface is formed from two-dimensional curve. Thus, it is difficult to predict the forming result. In this study, a regression analysis was suggested to construct a predictive model for a longitudinal curvature of FRRF process. To facilitate investigation, input parameters affecting the longitudinal curvature of FRRF were determined as maximum compression value, curvature radius in the transverse direction, and initial blank width. Three-factor three-level full factorial experimental design was utilized and 27 experiments using FRRF apparatus were performed to obtain sample data of the regression model. Regression analysis was carried out using experimental results as sample data. The model used for regression analysis was a quadratic nonlinear regression model. Determination factor and root mean square root error were calculated to confirm the conformity of this model. Through goodness of fit test, this regression predictive model was verified.

황동 개재물이 있는 Al 외팔형 정사각판의 자유진동해석 (Free Vibration Analysis of Al Cantilever Square Plates with a Brass Inclusion)

  • 이윤복;이영신;이세훈
    • 한국소음진동공학회논문집
    • /
    • 제15권12호
    • /
    • pp.1347-1354
    • /
    • 2005
  • The free vibration characteristics of Al cantilever square plates with a brass inclusion were analyzed experimentally and numerically The experimentally obtained natural frequencies and mode shapes were compared with the FEM analysis results. The impulse exciting method was used for experiment and ANSYS software package was used for FEM analysis. The natural frequencies obtained iron experiment and numerical analysis matched within $0\%$. It was found that the natural frequencies of the Al cantilever square plates with a brass inclusion decrease as the size of inclusion increases. For the third mode shape, comparing the nodal line of the Al plate and the Al plate with a inclusion, the mode shape showed the reversed quadratic curve. The natural frequencies of inclusion plate were decreased as the location of inclusion moves from the clamped edge to the tree edge.

A New Method for Monitoring Local Voltage Stability using the Saddle Node Bifurcation Set in Two Dimensional Power Parameter Space

  • Nguyen, Van Thang;Nguyen, Minh Y.;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.206-214
    • /
    • 2013
  • This paper proposes a new method for monitoring local voltage stability using the saddle node bifurcation set or loadability boundary in two dimensional power parameter space. The method includes three main steps. First step is to determine the critical buses and the second step is building the static voltage stability boundary or the saddle node bifurcation set. Final step is monitoring the voltage stability through the distance from current operating point to the boundary. Critical buses are defined through the right eigenvector by direct method. The boundary of the static voltage stability region is a quadratic curve that can be obtained by the proposed method that is combining a variation of standard direct method and Thevenin equivalent model of electric power system. And finally the distance is computed through the Euclid norm of normal vector of the boundary at the closest saddle node bifurcation point. The advantage of the proposed method is that it gets the advantages of both methods, the accuracy of the direct method and simple of Thevenin Equivalent model. Thus, the proposed method holds some promises in terms of performing the real-time voltage stability monitoring of power system. Test results of New England 39 bus system are presented to show the effectiveness of the proposed method.

중심도시와의 네트워크가 도시성장에 미치는 영향 (The Impact of Network with Central City on Urban Growth)

  • 엄현태;우명제
    • 국토계획
    • /
    • 제54권3호
    • /
    • pp.15-26
    • /
    • 2019
  • The development of science and transportation technology leads to the increase of inter - city networks that play an important role in urban growth. Overall, numerous studies based on network theory pay attention to positive effects of urban network on urban growth. However, some studies have pointed out the negative effects of inter-city interactions such as straw effects. This implies that the network between cities may not be positively correlated with urban growth, and that the direction of the influence may vary from a certain threshold, such as the marginal utility curve. In this context, the purpose of this study is to measure the impacts of network with central city on urban growth in the capital region and examine the relationship between urban network and growth. Two multiple regression models are employed with changes in population and employment as dependent variables. The urban network index and other control variables are used as independent variables. Especially, the urban network indexes are used in quadratic forms to examine non linear relations with urban growth such U-shape or an inverted U-shape. The results show that the relationships between networks with the central city and urban growth are not a simple linear, and the influence can be changed from the critical point.

Soil vibration induced by railway traffic around a pile under the inclined bedrock condition

  • Ding, Xuanming;Qu, Liming;Yang, Jinchuan;Wang, Chenglong
    • Geomechanics and Engineering
    • /
    • 제24권2호
    • /
    • pp.143-156
    • /
    • 2021
  • Rail transit lines usually pass through many complicated topographies in mountain areas. The influence of inclined bedrock on the train-induced soil vibration response was investigated. Model tests were conducted to comparatively analyze the vibration attenuation under inclined bedrock and horizontal bedrock conditions. A three-dimension numerical model was built to make parameter analysis. The results show that under the horizontal bedrock condition, the peak velocity in different directions was almost the same, while it obviously changed under the inclined bedrock condition. Further, the peak velocity under inclined bedrock condition had a larger value. The peak velocity first increased and then decreased with depth, and the trend of the curve of vibration attenuation with depth presented as a quadratic parabola. The terrain conditions had a significant influence on the vibration responses, and the inclined soil surface mainly affected the shallow soil. The influence of the dip angle of bedrock on the peak velocity and vibration attenuation was related to the directions of the ground surface. As the soil thickness increased, the peak velocity decreased, and as it reached 173% of the embedded pile length, the influence of the inclined bedrock could be neglected.

태양열 공기가열 집열기에 의한 난방 실내공간의 열유동 특성 해석 (Analysis on Characteristics of Thermal Flow for Heating Indoor Space by Air-heating Collector using Solar Heat)

  • 양영준
    • 한국산업융합학회 논문집
    • /
    • 제25권2_2호
    • /
    • pp.271-278
    • /
    • 2022
  • The solar energy has been widely used to reduce the fossil fuel and prevent the environmental pollution. The renewable energy including solar heat tends to spread due to carbon neutrality for main country of the world. Targets of solar collector are usually acquisitions of hot water or hot air. Especially, air-heating collector using solar heat is known as the technology for obtaining hot air. This study aims to investigate of characteristics of thermal flow when the hot air by air-heating collector using solar heat flows inside of indoor space. The thermal flow of heating indoor space was simulated using ANSYS-CFX program and thus the behaviors of hot air in indoor space were evaluated with standard k-𝜀 turbulence model. As the results, as the inlet velocity was increased, the behaviors of hot air became simple, and temperature range of 25~75℃ had almost no effect on behavior of flow. As the inlet temperature was increased, the temperature curve of indoor space from bottom to top was changed from linear to quadratic. Furthermore, it was confirmed that inlet velocity as well as inlet temperature also should be considered to heat indoor space equally by air-heating collector using solar heat.

Deformation characteristics and stability analysis of semi-covered deep excavations with existing buildings

  • Linfeng Wang;Xiaohan Zhou;Tao Chen;Xinrong Liu;Peng Liu;Shaoming Wu;Feng Chen;Bin Xu
    • Geomechanics and Engineering
    • /
    • 제34권1호
    • /
    • pp.87-102
    • /
    • 2023
  • The cover plate and the building loads often make the semi-covered deep excavations with existing buildings bearing asymmetric load, presenting different deformation characteristics with normal excavations, which is not absolutely clear in current studies. Based on a typical engineering, the building storeys, the basement storeys, the pile length, the existence of the cover plate (CP) and the depth of the diaphragm walls (DW) were selected as variables, and 44 groups of simulation were designed to study the influence of existing buildings and the semi-covered supporting system on the deformation of the excavations. The results showed that the maximum lateral displacement of DW, δhm, and the depth of δhm, Hm, are affected seriously by the building storeys and the basement storeys. Asymmetric structures and loading lead to certain lateral displacement of DW at the beginning of excavation, resulting in different relationships between δhm and excavation depth, H. The maximum surface settlement outside the pit, δvm, increases significantly and the location, dm, moves away from the pit with the building storeys increases. δvm has a quadratic correlation with H due to the existing buildings. CP and building load will affect the style of the lateral displacement curve of DW seriously in different aspects.

The Trajectory of Depressive Symptoms Across Years of Community Care Utilization Among Older Adults: A 14-Year Follow-up Study Using the 'Korean Welfare Panel Survey'

  • Il-Ho Kim;Cheong-Seok Kim;Min-Hyeok Jeong
    • Journal of Preventive Medicine and Public Health
    • /
    • 제56권6호
    • /
    • pp.495-503
    • /
    • 2023
  • Objectives: While older adults using community care services are known to be vulnerable for depression, community care utilization (CCU) may help to improve the mental health of these elderly. To date, however, it is much less clear how CCU affects depressive symptoms in the elderly population. This study focuses on the trajectory of depressive symptoms across years of CCU among older adults in Korea. Methods: Using the 2006-2019 Korean Welfare Panel Survey, this study is focused on elderly born in 1940 or earlier and selected 3281 persons for baseline interviews in 2006. This consisted of 35 800 person-year observations during a period of 14 years. Panel data analysis were employed to construct years of CCU. Results: After controlling for covariates, linear term of years using community care was negatively associated with depressive symptoms, but a quadratic term was positively significant. The trajectory of depressive symptoms across the years of CCU follows a U-shaped curve. Older adults in the first year of using community care reported the highest level of depressive symptoms. However, a significant and steady decrease in depressive symptoms was observed during the following 9 years of CCU, which then gradually increased. The level of depressive symptoms at the 14th year of using community care remains significantly lower than the level at the outset of its utilization. Conclusions: This finding implies that CCU could be beneficial for improving mental health among older adults.

소형 쉘앤튜브형 열교환기의 운전 조건에 따른 열유동 거동 특성 해석 (Analysis on Characteristics of Behavior of Thermal Flow According to Operation Conditions of Small-sized Shell and Tube-type Heat Exchanger)

  • 양영준
    • 한국산업융합학회 논문집
    • /
    • 제26권6_2호
    • /
    • pp.1109-1115
    • /
    • 2023
  • The shell and tube-type heat exchanger was the most utilized in industrial field because of its simple structure and wide operation conditions and so on. This study was performed to investigate the characteristics of behavior of thermal flow according to operation condition of small-sized shell and tube-type heat exchanger. The operation conditions, here, were set up to flow rate of hot air with temperature of 100℃, number of baffle and cut rate of baffle(BCR) using numerical analysis. As the results, both mean relative pressure and relative pressure drop was increased with quadratic curve in case of less than BCR 25%, however, decreased linearly in case of more than BCR 25%. The collision with first baffle by flow velocity and temperature, of hot air, respectively, was depended on BCR. Further it showed that the behaviors between flow velocity and temperature were almost similar.

방사선에 전신 조사된 마우스 음와 세포의 아포토시스 유도를 이용한 생물학적 선량 측정 모델 개발 연구 (Mouse model system based on apoptosis induction to crypt cells after exposure to ionizing radiation)

  • 김태환
    • 대한수의학회지
    • /
    • 제41권4호
    • /
    • pp.571-578
    • /
    • 2001
  • 방사선 피폭선량의 예측을 위한 방사선 민감 지표 모델 개발의 일환으로 apoptotic fragment assay법이 방사선에 피폭된 후 체내 피폭선량을 예측할 수 있는 지표로의 이용 가능성을 평가하기 위하여 코발트-60 감마선과 의료용 싸이크로트론 50MeV($p{\rightarrow}Be^+$) fast neutron 을 0.25Gy에서 1Gy의 선량을 마우스에 각각 전신 조사한 후 소장 음와세포내 apoptotic crypt cell의 수적 변화를 관찰하였다. 저선량 조사군에서 apoptotic crypt cell의 출현 빈도가 1Gy까지 급격하게 증가한 것으로 보아 방사선이 stem cell 지역에 있는 crypt cell의 형태학적 변화를 유발하는 것으로 나타났다. 이상의 결과는 아포토시스가 손상된 세포를 제거하므로 손상된 방사선 민감 표적 장기의 항상성 유지에 중요한 역할을 하는 것으로 판단되었다. Apoptotic fragments의 발생빈도에 대한 선량-반응 곡선에 있어서 음와세포는 중성자조사군이 $y=0.18+(9.728{\pm}0.887)D+(-4.727{\pm}1.033)D^2$ ($r^2=0.984$)으로, 반면에 감마선조사군은 $y=0.18+(5.125{\pm}0.601)D+(-2.652{\pm}0.7000)D^2$ ($r^2=0.970$)의 식을 얻었다. 이와 같이 중성자조사군과 감마선조사군은 공히 linear quadratic model 로 관찰되었다. apoptotic fragments 의 발생빈도와 조사 선량간에 유의한 효과가 있는 것으로 확인되었다. 이상의 결과에서 조사선량의 증가에 비례하여 방사선 민감 세포의apoptotic fragments 가 수적으로 증가하였으며, 고준위 방사선과 저준위 방사선은 선량 반응 관계식과 시간 경과에 따른 영향이 매우 유사하였으며, 마우스 음와세포의 apoptosis 유도에 대한 중성자선의 방사선 생물학적 효과비(RBE)는 2.072이였다. 그리고 모든 방사선조사군에서 방사선피폭 후 4시간과 6시간에 apoptosis 유도가 가장 많았으며, 음와세포의 형태학적 소견은 정상 대조군에서 관찰되지 않는 전형적인 apoptotic fragments 가 나타났다. 따라서 음와 세포에서의 아포토시스 유도는 방사선 피폭으로 발생된 세포 손상의 생물학적 영향 평가검색, 방사선 방호제의 민감도 검사, 방사성 동위원소의 체내 오염에 대한 체내 피폭선량 예측의 지표 및 방사선 민감 표적장기의 손상정도 파악에 이용 가능할 것임. Apoptotic fragment assay 법은 0.25Gy에서 1Gy 까지의 선량에서 간편하고 빠르며 재현성이 있는 지표로서 방사선 민감 표적 장기의 선량 반응 평가와 방사선 피폭후 조기 피폭선량 예측을 위한 방사선 생물학적 선량측정법의 좋은 지표로 사용할 수 있을 것으로 사료됨.

  • PDF