• Title/Summary/Keyword: putty type

Search Result 19, Processing Time 0.024 seconds

Characteristic Analysis of Paint used in Defense Industries Equipments of Korean Conflict in The War Memorial of Korea (전쟁기념관 소장 6·25전쟁 방산장비의 도료 특성 분석)

  • Kang, Hyun Sam;Kim, Soo Chul;Park, Min Soo
    • Journal of Conservation Science
    • /
    • v.32 no.2
    • /
    • pp.215-221
    • /
    • 2016
  • This study conducted analysis of paint samples from defense industries equipments of Korean Conflict in The War Memorial of Korea to identify the characteristics of the modern paint. The samples were analyzed by microscopic observation, infrared spectroscopy and SEM-EDS. Cross-section of paint samples are made up of several layers of about 9 to 20 times, and thickness of the layer is not uniform in the $10{\sim}100{\mu}m$. The putty was used for the surface treatment before painting. Inorganic analysis showed that one type of the putty consist of minium and kaolin, talc, titanium dioxide. According to the results of infrared spectroscopy, paint samples were identified as alkyd resin. Some bands such as C-H bending, C-O and C-C stretching, C-H rocking were found in spectra.

Analysis of Paint used in Streetcar No. 381 of Registered Culture Property (등록문화재 전차381호의 도료 분석)

  • Kim, Soo Chul;Park, Min Soo;Seo, Jeong Hun
    • Journal of Conservation Science
    • /
    • v.28 no.3
    • /
    • pp.277-283
    • /
    • 2012
  • This study conducted analysis of paint samples from a streetcar No. 381 (Registration Cultural Property No. 467) to identify the characteristics of the modern paint. The samples were analyzed by Microscopic observation, infrared spectroscopy and SEM-EDS. The upper part is consist of 26 layers and the under part is 29 layers. And the layers were painted various thickness from $10{\mu}m$ to $100{\mu}m$, and confirmed that several color had been used. The putty was used for surface treatment before painting. According to the results of infrared spectroscopy, paint specimens were identified as alkyd resin. Some bands such as C-H and C=O stretcing, aromatic, C-H bending, C-O stretching were found in spectra. Inorganic analysis showed that gold color on the surface was used copper-based paint. And type of the putty was lacquer-putty that was consist of kaolin, talc and zinc white.

Evaluation of Flexural strength and surface porosity of three indirect composite resins (3종의 간접수복용 복합레진의 굴곡강도 비교 및 표면관찰)

  • Kim, Jun-Tae;Park, Jin-Young;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.39 no.1
    • /
    • pp.9-16
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate flexural strength, composite surface and fractured surface of three different indirect composite resins. Methods: Fifteen bar-shaped specimens ($25mm{\times}2mm{\times}2mm$) were fabricated for each FL group (Flow type and Light curing) and PLP group (Putty type and Light, Pressure curing) and PL group (Putty type and Light curing) according to manufacturer's instructions and ISO 10477. Fabricated specimens were stored in the distilled water for 24 hours at the temperature of $37^{\circ}C$. Three-point bending strength test was performed to measure flexural strength using universal testing machine at a crosshead speed of 1mm/min (ISO 10477). Surface and fractured surface of specimens were observed by digital microscope. Results were analyzed with Kruskal-wallis tests (${\alpha}=0.05$). Results: Mean (SD) of three different indirect composite resins were 83.38 (6.67) MPa for FL group, 139.90(16.53) MPa for PLP group and 171.72(16.74) MPa for PL group. Flexural strength were statistically significant (p<0.05). Differences were not observed at fractured surface among three groups. However, many pores over $100{\mu}m$ were observed at PL group in observing surface of specimen. Conclusion: Flexural strength of composite resins was affected by second polymerization method and content of inorganic filler.

A GEOMETRIC STANDARDIZATION OF PERIAPICAL INTRAORAL RADIOGRAPHY (구내 표준 방사선 사진촬영의 위치 표준화)

  • Choi Bong-In;Nah Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.2
    • /
    • pp.415-423
    • /
    • 1991
  • This study was performed to evaluate the geometric standardization of periapical intraoral radiography. Image distortion was measured by analysing serial radiography obtained from dry skull using 5 types of bite registration device. After 16 weeks, the angular distortion of Pattern resin was 0.26±0.14 degree(Horizontal angle 0.17±0.14, Vertical angle 0.16±0.11) which was the lowest among the 5 registration device, and that of putty type Exaflex was 0.49±0.35 degree(Horizontal angle 0.42±0.35, Vertical angle 0.17±0.13) which was the highest. The mean amount of distortion variance of Tooth shade acrylic at each experimental period was 0.06±0.08 which was the lowest among the 5 registration device, and that of XCP alone was 0.ll±0.13 which was the highest.

  • PDF

Evaluating the usefulness of BinkieRTTM (oral positioning stent) for Head and Neck Radiotherapy (두경부암 환자 방사선 치료 시 BinkieRTTM(구강용 고정장치)에 대한 유용성 평가)

  • GyeongJin Lee;SangJun Son;GyeongDal Lim;ChanYong Kim;JeHee Lee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.21-30
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of oral positioning stent, the BinkieRTTM in radiation treatment for head and neck cancer patients in terms of tongue positions reproducibility, tongue doses and material properties. Materials and Methods: 24 cases using BinkieRTTM during radiation treatments were enrolled. The tongue was contoured on planning CT and CBCT images taken every 3 days during treatment, and then the DSC and center of tongue shift values were analyzed to evaluate the reproducibility of the tongue. The tongue dose was compared in terms of dose distribution when using BinkieRTTM and different type of oral stents (mouthpiece, paraffin wax). Randomly selected respective 10 patients were measured tongue doses of initial treatment plan for nasal cavity and unilateral parotid cancer. Finally, In terms of material evaluation, HU and relative electron density were identified in RTPS. Results: As a result of DSC analysis, it was 0.8 ± 0.07, skewness -0.8, kurtosis 0.61, and 95% CI was 0.79~0.82. To analyze the deviation of the central tongue shift during the treatment period, a 95% confidence interval for shift in the LR, SI, and AP directions were indicated, and a one-sample t-test for 0, which is an ideal value in the deviation(n=144). As a result of the t-test, the mean and SD in the LR and SI directions were 0.01 ± 0.14 cm (p→.05), 0.03 ± 0.25 cm (p→.05), and -0.08 ± 0.25 cm (p ←.05) in the AP direction. In the case of unilateral parotid cancer patients, the Dmean to the tongue of patients using BinkieRTTM was 16.92% ± 3.58% compared to the prescribed dose, and 23.99% ± 10.86% of patients with Paraffin Wax, indicating that the tongue dose was relatively lower when using BinkieRTTM (p←.05). On the other hand, among nasal cavity cancer patients, the Dmean of tongue dose for patients who used BinkieRTTM was 4.4% ± 5.6%, and for those who used mouthpiece, 5.9% ± 6.8%, but it was not statistically significant (p→.05). The relative electron density of Paraffin Wax, BinkieRTTM and Putty is 0.94, 0.99, 1.26 and the mass density is 0.95, 0.99 and 1.32 (g/cc), Transmission Factor is 0.99, 0.98, 0.96 respectively. Conclusion: The result of the tongue DSC analysis over the treatment period was about 0.8 and Deviation of the center of tongue shifts were within 0.2 cm, the reproducibility was more likely excellent. In the case of unilateral head and neck cancer patients, it was found that the use of BinkieRTTM rather than Paraffin Wax or Putty can reduce the unnecessary dose irradiated to the tongue. This study might be useful to understand of BinkieRTTM's properties and advantages. And also it could be another considered option as oral stent to keep the reproducibility of tongue and reducing dose during head and neck radiation treatments.

Construction of Static 3D Ultrasonography Image by Radiation Beam Tracking Method from 1D Array Probe (1차원 배열 탐촉자의 방사빔추적기법을 이용한 정적 3차원 초음파진단영상 구성)

  • Kim, Yong Tae;Doh, Il;Ahn, Bongyoung;Kim, Kwang-Youn
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.2
    • /
    • pp.128-133
    • /
    • 2015
  • This paper describes the construction of a static 3D ultrasonography image by tracking the radiation beam position during the handy operation of a 1D array probe to enable point-of-care use. The theoretical model of the transformation from the translational and rotational information of the sensor mounted on the probe to the reference Cartesian coordinate system was given. The signal amplification and serial communication interface module was made using a commercially available sensor. A test phantom was also made using silicone putty in a donut shape. During the movement of the hand-held probe, B-mode movie and sensor signals were recorded. B-mode images were periodically selected from the movie, and the gray levels of the pixels for each image were converted to the gray levels of 3D voxels. 3D and 2D images of arbitrary cross-section of the B-mode type were also constructed from the voxel data, and agreed well with the shape of the test phantom.

Fracture resistance and marginal fidelity of zirconia crown according to the coping design and the cement type (코핑 디자인과 시멘트에 따른 지르코니아 도재관의 파절 저항성)

  • Sim, Hun-Bo;Kim, Yu-Jin;Kim, Min-Jeong;Shin, Mee-Ran;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.194-201
    • /
    • 2010
  • Purpose: The purpose was to compare the marginal fidelity and the fracture resistance of the zirconia crowns according to the various coping designs with different thicknesses and cement types. Materials and methods: Zirconia copings were designed and fabricated with various thicknesses using the CAD/CAM system (Everest, KaVo Dental GmbH, Biberach., Germany). Eighty zirconia copings were divided into 4 groups (Group I: even 0.3 mm thickness, Group II: 0.3 mm thickness on the buccal surface and the buccal half of occlusal surface and the 0.6 mm thickness on the lingual surface and the lingual half of occlusal surface, Group III: even 0.6 mm thickness, Group IV: 0.6 mm thickness on the buccal surface and the buccal half of occlusal surface and the 1.0 mm thickness on the lingual surface and the lingual half of occlusal surface) of 20. By using a putty index, zirconia crowns with the same size and contour were fabricated. Each group was divided into two subgroups by type of cement: Cavitec$^{(R)}$ (Kerr Co, USA) and Panavia-$F^{(R)}$ (Kuraray Medical Inc, Japan). After the cementation of the crowns with a static load compressor, the marginal fidelity of the zirconia crowns were measured at margins on the buccal, lingual, mesial and distal surfaces, using a microscope of microhardness tester (Matsuzawa, MXT-70, Japan, ${\times}100$). The fracture resistance of each crown was measured using a universal testing machine (Z020, Zwick, Germany) at a crosshead speed of 1 mm/min. The results were analyzed statistically by the two-way ANOVA and oneway ANOVA and Duncan's multiple range test at $\alpha$=.05. Results: Group I and III showed the smallest marginal fidelity, while group II demonstrated the largest value in Cavitec$^{(R)}$ subgroup (P<.05). For fracture resistance, group III and IV were significantly higher than group I and II in Cavitec$^{(R)}$ subgroup (P<.05). The fracture resistances of Panavia-$F^{(R)}$ subgroup were not significantly different among the groups (P>.05). Panavia-$F^{(R)}$ subgroup showed significantly higher fracture resistance than Cavitec$^{(R)}$ subgroup in group I and II (P<.05). Conclusion: Within the limitation of this study, considering fracture resistance or marginal fidelity and esthetics, a functional ceramic substructure design of the coping with slim visible surface can be used for esthetic purposes, or a thick invisible surface to support the veneering ceramic can be used depending on the priority.

A Study on the Manufacturing and Applicability of Rosin-based Epoxy Adhesives and Filling Material for Conservation of Wood Crafts (목공예품 보존용 송진 기반 에폭시 접착제 및 메움제의 제조와 적용성에 관한 연구)

  • Wi, Koang-Chul;Han, Won-Sik;Oh, Seung-Jun
    • Journal of Conservation Science
    • /
    • v.36 no.6
    • /
    • pp.475-482
    • /
    • 2020
  • In this study, we synthesized rosin-based epoxy resin and manufactured two components adhesives and epoxy putty using this epoxy resin. This study manufactured main element of adhesives for enabling it to form epoxide group by letting epichlorohydrin react to maleic anhydride modified rosin, and used room temperature curing type triethylenetetramine for hardener. The ratio between main element and hardener of of manufactured adhesives was 100 : 20, and main element and hardener of filling material were manufactured as clay type by mixing them with filler. Manufactured undiluted adhesives and filling material showed very stable result in the adhesive strength (3.06 MPa) and ultraviolet irradiation, showing outstanding result comparing to existing restoration adhesives. And it is considered a material having reversibility as it was dissolved in organic solvents such as acetone and toluene after being hardened, which showed a result that solved part of possible problems caused by restoration. As a result of use and application of manufactured adhesives and filling material for actual wood crafts, they showed excellent results in workability, stability, removability etc., and this study confirmed that the material can be used for and applied to various fields.

A Study on the Development of Poly-Urea for Porcelain Restoration (폴리우레아 도자기 복원 재료의 적용)

  • Han, Won-Sik;Wi, Koang-Chul;Oh, Seung-Jun;Lee, Young-Hoon
    • Journal of Conservation Science
    • /
    • v.34 no.1
    • /
    • pp.23-29
    • /
    • 2018
  • This study synthesized poly-urea and used it as a filler material for the restoration of porcelain. The synthesized poly-urea was manufactured as a resin and hardener mix that does not undergo contraction during curing, and is unfading. Given an adhesion strength of $180kg/cm^2$ and shearing strength of $200kg/cm^2$, the synthesized poly-urea exhibited the same efficacy as the epoxy putty currently sold in the market. Moreover, it also overcame the drawback of foaming encountered by urethane restoratives, which are a structurally similar type. The hardening time and pot life could also be controlled using additives. The poly-urea used for the restoration of modern artifacts presented a pot life of approximately one hour and took 12 h for complete hardening ($T_{90}$). When a $2{\times}2{\times}2cm$-sized test sample was added to xylene, poly-urea started to separate approximately two hours later and completed perfect pulverization within the solution 24 h later, demonstrating its reversibility. When directly applied to contemporary artifacts, it demonstrated the potential for restoration, as well as convenience and colorfulness.