• 제목/요약/키워드: purification method

검색결과 848건 처리시간 0.033초

3 Types of Set Point Controllers for Biological Wastewater Treatment Process

  • Kim, D.;Lee, I.B.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.97.1-97
    • /
    • 2001
  • One of the main problems to constitute control method on biologically oriented wastewater purification processes, e.g. activated sludge process, sequential batch reactor, rotating bio-disk contactor, etc. is that it is hard to control the target component directly. For instance, while biochemical oxygen demand, suspended solids, and chemical oxygen demand are the key components to check the process performance, one may not control them directly since they are the results of microbial activities related to numerous physiochemical factors. Therefore controllers for bioprocess should be designed to make favorable condition for microorganisms´ living, e.g. dissolved oxygen level favorable, mixed liquor suspended solids concentration suitable ...

  • PDF

HPLC-ESI/MS를 이용한 Eleutheroside B와 E의 정량 (Quantitative Analysis of Eleutherosides B and E Using HPLC-ESI/MS)

  • 최영해;김진웅
    • 생약학회지
    • /
    • 제33권2호통권129호
    • /
    • pp.88-91
    • /
    • 2002
  • Liquid-chromatography coupled with electrospray-ion trap mass spectrometry was applied to the analysis of the eleutherosides B and E in the Eleutherococcus senticosus cortexes. The optimum ESI/MS results were obtained in the positive ion mode using extracted ion chromatogram targeting Na-adduct molecular ion of each compound. This method allowed rapid and simple gradient separation of underivatized eleutherosides B and E without pre-purification steps at very low concentration.

초임계 이산화탄소에서 히노키치올의 용해도 측정과 예측 (Measurement and Correlation of Hinokitiol Solubility in Supercritical Carbon dioxide)

  • 신문삼
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2011년도 춘계학술논문집 1부
    • /
    • pp.489-492
    • /
    • 2011
  • Supercritical fluid technology has been an alternative for purification and separation of biological compounds in cosmetic, food, and pharmaceutical products. Solubility information of biological compounds in supercritical fluids is essential for choosing a supercritical fluid processes. The equilibrium solubility of hinokitiol was measured in supercritical carbon dioxide with a static method in the pressure range from 8 to 40 MPa and at temperatures equal to 313.2, 323.2 and 333.2 K. The experimental data were correlated well by Peng.Robinson equation of state and quasi-chemical nonrandom lattice fluid model.

  • PDF

Magnetic Force Control Technique for Recycling and Environmental Preservation

  • Nishijima, Shigheiro
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권4호
    • /
    • pp.1-4
    • /
    • 2012
  • The applicability of the two types of magnetic separation system, high gradient magnetic separation (HGMS) and Magneto Archimedes method were studied considering the magnetic susceptibility of targeted substances. It was noted that the combination of the two methods can control the almost all the substances, paramagnetic and diamagnetic in addition to ferromagnetic substances. The principle of the methods was given and the conceput of the magnet force control technology is discussed. The practical applications of the technique were introduced together with the new application of HGMS.

수돗물의 전기분해에 의해서 생성된 알카리수의 pH가 SS 400강의 부식특성에 미치는 영향 (Effect on Corrosion Characteristics of SS 400 Steel by Alkali Water pH from Electrolysis of City Water)

  • 문경만;류해전;김윤해;정재현;백태실
    • 한국해양공학회지
    • /
    • 제31권3호
    • /
    • pp.248-255
    • /
    • 2017
  • Many rivers and seas have been affected by environmental contamination. Therefore, city water supplies often require a high-degree purification treatment to provide safe drinking water. However, in order to achieve a high-degree purification treatment, a large amount of chlorine has to be added to sterilize city drinking water. The added chlorine reacts chemically with water and forms hypochlorous and chlorine ions. The hypochlorous ionizes with hypochlorous ions and hydrogen ions. As a result, the city water contains a large amount of chlorine ion. As such, when city water is used with domestic boilers, many kinds of heat exchangers, and the engines of vehicle and ships, there are often corrosion problems. In this study, alkali water was electrochemically made by electrolysis of city water, and corrosion properties between alkali and city water were investigated with an electrochemical method. Most of the chlorine ions are thought to not be contained in the alkali water because the alkali water is created in the cathodic chamber with an electrolysis process. In other words, the chlorine ion can be mostly removed by its migration from a cathodic chamber to an anodic chamber. Moreover, the alkali water also contains a large amount of hydroxide ion. The alkali water indicated relatively good corrosion resistance compared to the city water and the city water exhibited a local corrosion pattern due to the chlorine ion created by a high-degree purification treatment. In contrast, the alkali water showed a general corrosion pattern. Consequently, alkali water can be used with cooling water to inhibit local corrosion by chlorine ions in domestic boilers, various heat exchangers and the engine of ships and for structural steel in a marine structure.

Development of an exclusive column method for 82Sr/82Rb generator using a 100 MeV proton linear accelerator of KOMAC

  • Kye-Ryung Kim;Yeong Su Ha;Sang-Pil Yoon;Yeon-ji Lee;Yong-Sub Cho;Hyeongi Kim;Sang-Jin Han;Jung Young Kim;Kyo Chul Lee;Jin Su Kim
    • 대한방사성의약품학회지
    • /
    • 제7권2호
    • /
    • pp.119-125
    • /
    • 2021
  • 82Sr for 82Rb generator was produced through the irradiation of the proton beam on the nat.RbCI target at the target irradiation facility installed at the end of the Rl-dedicated beamline of the 100 MeV proton linear accelerator of KOMAC (Korea Multi-purpose Accelerator Complex). The average current of the proton beam was 1.2 µA for irradiation time of 150 min. For the separation and purification of the 82Sr from nat.RbCI irradiated, Chelex-100 resin was used. The activities of 82Sr in the irradiated nat.RbCI target solution and after purification were 45.29 µCi and 43.4 µCi, respectively. The separation and purification yield was 95.8%. As an adsorbent to be filled in the generator for 82Sr adsorption hydrous tin oxide was selected. The adsorption yield of 82Sr into the generator adsorbent was > 99 %, and the total amount of 82Sr adsorbed to the generator was 21.6 µCi as of the day of the 82Rb elution experiment. When the elution amount was 22 mL, the maximum82Rb elution yield was 93.3%, and the elution yield increased as the flow rate increased. After the eluted 82Rb was filled in the correction phantom of the small PET for animals, a PET image was taken. The image scan time was set to 5 min, and the phantom PET image was successfully obtained. As results of impurity analysis on eluted 82Rb using ICP-MS, nat.Rb stable isotopes that compete in vivo of 82Rb were identified as undetected levels and were determined to be No-Carrier-Added (NCA).

실리카광물의 산침출 정제와 불순물 분석법 연구 (Impurity analysis and acid leaching purification of silica minerals)

  • 이길용;윤윤열;조수영;채영배
    • 분석과학
    • /
    • 제20권6호
    • /
    • pp.516-523
    • /
    • 2007
  • 2N급(99 %)의 실리카를 3N급(99.9 %)으로 향상시키기 위해서 널리 이용되고 있는 산 침출법(acid leaching)들의 정제효과와 실리카광물에 존재하는 불순물의 분석법에 대한 연구를 수행하였다. 산 침출법에 이용한 용액은 0.2M-oxalic acid (pH1.5, 2.5), conc-Aqua regia, 2.5 %-HCl/HF, 1 %-$HNO_3/HF$의 다섯 종류이었으며, 각 방법의 불순물 정제특성과 침출시간에 따른 침출효율을 조사하였다. 실리카광물과 침출용액중의 불순물 분석은 중성자방사화분석법(neutron activation analysis; NAA), 유도결합 플라즈마 원자방출 분석법(inductively coupled plasma atomic emission spectrometry; ICP-AES), 원자흡광 분광분석법(atomic absorption spectrometry; AAS), x-선 형광분석법(x-ray fluorescence; XRF), 그리고 습식분석법(wet analysis; WA)의 여섯 가지 방법을 이용하였으며, 불순물의 농도와 종류에 따른 분석법들의 장단점을 조사하였다. 실험에 사용한 실리카광물은 습식 비중선별 및 자력선별과 같은 물리적 정제를 거친 순도 99 %급의 실리카로서 $100-150{\mu}m$ 범위의 입도분포를 가지는 분말들이었다. 실리카중 주요 불순물은 Al, Fe, Na, Ca 및 Ti 이었으며 수백에서 수천 mg/kg의 농도로 존재하고 있었다. 산 침출방법과 불순물의 종류에 따른 정제효과를 비교한 결과 2.5 %-HCl/HF 침출방법이 가장 효과적이었으며 이 방법으로 99.1 % 실리카 분말을 99.8 %까지 순도를 향상시킬 수 있었다. 또한 실리카광물과 침출용액의 불순물의 종류와 함량에 따른 최적의 분석기술을 결정할 수 있었다.

Methods for the Extraction of DNA from Water Samples for Polymerase Chain Reaction

  • Jung, Jae-Sung;Lee, Young-Jong
    • Journal of Microbiology
    • /
    • 제35권4호
    • /
    • pp.354-359
    • /
    • 1997
  • Methods for the extraction of DNA from water sample were approximated. Four different procedures of DNA extraction were carried out with pellets obtained from centrifugation of 4 liter water samples. The recovery efficiency and purity of DNA extracted by each method from different sources were compared. DNA yield varied with extraction methods, Method I, which involves enzymatic and freeze-thaw lysis steps and phenol and phenol-chloroform purification of extracted nucleic acid, showed a significantly higher yield and purity than the other methods. The use of glass beads in the DNA extraction methods improved the purity of DNA suitable for PCR. Bovine serum albumin in the PCR reaction mixture was useful in reducing inhibitory effects of contaminants. The efficiency of an extraction method was determined by the detection of the aer of Aeromonas hydrophila with PCR. The lower limit of detection of A. hydrophila from seeded tap water was 2 CFU/ml in PCR when method I was used for DNA preparation.

  • PDF