• 제목/요약/키워드: purge & trap gc-ms

검색결과 27건 처리시간 0.021초

Comparison between Head Space Gas Sampling and Purge & Trap Sampling in Water Analysis

  • Nagayanagi, Yutaka;Nakagawa, Katsuhiro;Saito, Yoshihiro;Kim, Poongzag
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.739-744
    • /
    • 1995
  • The two main methods to prepare water samples for analyzing volatile organic compounds(VOC's) were investigated. One is the purge and trap(PT) method and another is the head space(HS) sampling method. Both methods were effective to transfer the low boiling point components from the water sample onto the capillary column. The cryo-focusing at the top of the main capillary column was an effective way to obtain the sharpness of the chromatographic peaks but could be avoided when a semi-wide bore column was used. The recovery from the same amount of the sample was better in PT than in HS but a larger sample volume in HS method could compensate the lower efficiency. Therefore PT is suitable to the analysis of drinking water where the very low concentration must be determined. HS is suitable to waste water analysis because of the easiness of the operation. The repeatability was good and similar in both methods. For the contamination of the former sample, both methods were tough and could be used without any problems. The matrix effect which could change the equilibrium parameters in HS method was find negligible in many components. The actual samples such as tap water and river water were analyzed with both methods concerning 16 components regulated in Korea.

  • PDF

Purge-and-Trap법에 의해 추출한 참기름 향기성분 분석 (Analysis of Volatile Flavor Compounds in Sesame Oil Extracted by Purge-and-Trap Method)

  • 이상화;주광지
    • 한국식품과학회지
    • /
    • 제30권2호
    • /
    • pp.260-265
    • /
    • 1998
  • 참깨를 170, 200, $230^{\circ}C$로 열풍순환식과 전기팬에서 볶아서 참유한 기름의 향기 성분을 GC와 GC-MS로 분석하여 동정 확인하고 관능 검사를 실시하였다. 총 33개의 향기성분이 확인 되어졌으며 pyrazine류 14종, thiazole류 7종, pyridine류 4종, oxazole류 2종 및 기타 6종 이였다. 전기팬에서 170, 200, $230^{\circ}C$에서 처리된 시료의 총 향기성분의 함량은 각각 145.29, 334.65, 313.04 ppm 이였고 열풍순환식에서는 각각 28.86, 81.20, 313.28 ppm이 였다. 그리고 개별향기 성분중에서는 pyrazine류의 함량비가 가장 높았다. 6개의 시료에 대한 관능 검사의 결과는 $200^{\circ}C$에서 배전식 방법으로 볶은 참깨로부터 제조된 참기름이 가장 바람직한 향기를 가진것으로 판단되어졌다. 이런 현상은 GC 분석의 결과와 일치하였다.

  • PDF

Analytical Method of Epichlorohydrin in Canned Beverages by Purge-and- Trap/GC

  • Lee Kwang-Ho;Kwak In-Shin;Kim Dyoung-Il;Choi Byoung-Hee;Kim Guy-Joung;Lee Chul-Won
    • 한국식품위생안전성학회:학술대회논문집
    • /
    • 한국식품위생안전성학회 2001년도 The Asia-Pacific Conference on Reproductive Biology and Environmental Sciences
    • /
    • pp.140-140
    • /
    • 2001
  • A sensitive analytical method based on gas chromatograpy-mass spectrometry with a selected ion monitoring (GC/MS-SIM) with the purge-and-trap concentration and with headspace method (in limited applications) was developed for determining of epichlorohydrin in canned beverages coated with epoxy resin. The calibration curve in the range of $0.5\sim50ng$ had correlation coefficient greater than 0.998 and a detection limit of $0.l\mug/L$ was obtained using a sample volume of 20ml. The predominant ions of epichlorohydrin produced in MSD using electron ionization(EI) were m/z 57 ([M-CI]+) and 62/64 $([M-CH_2O]+)$. In survey of epichlorohydrin in thirty commercial canned beverage samples, none of them was detected.

  • PDF

하천퇴적물 중의 수은 및 메틸수은 분석 연구 (Analysis of mercury and methylmercury in river sediment samples)

  • 이정섭;박재성;강학구;조재석;홍은진;정기택;차준석;정광용;김영희
    • 분석과학
    • /
    • 제22권1호
    • /
    • pp.44-50
    • /
    • 2009
  • 본 연구에서는 퍼지 & 트랩 GC-MS를 이용한 퇴적물 중의 메틸수은 분석방법을 제시하고, 국내 주요 하천 퇴적물 중의 총수은 및 메틸수은 등을 분석하였다. 분석방법의 검증을 위하여 고농도 및 저농도의 인증표준물질 2종을 분석하였으며, 현장시료 81건에 대하여 EPA 1630 method 원리의 GCCVAFS 방법으로 분석한 결과와 GC-MS 방법의 분석결과를 비교하였다. 방법검출한계 (MDL)는 0.06 ng/g, 정량한계 (MQL)는 0.20 ng/g이었으며 정밀도와 정확도는 각각 11.2% 및 $102{\pm}11.4%$로 나타났다. 조사된 81건에 대한 하천 퇴적물의 총수은 및 메틸수은 농도는 $2.43{\sim}1.56{\times}10^3$ ng/g 및 N.D.~5.95 ng/g 로 나타났다. 총수은의 분포특성은 외부오염원에 의한 영향으로 인해 유기물, 황함량 및 납, 크롬, 니켈 등의 중금속 농도와 유의한 상관성이 나타났으나, 메틸수은의 경우, 총수은을 제외한 다른 인자들과의 유의한 상관성이 조사되지 않았다.

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • 분석과학
    • /
    • 제34권1호
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.

SPME를 이용한 수용액중의 휘발성 유기화합물 분석 (Determination of Volatile Organic Compounds (VOCs) in Drinking Water using Solid Phase Microextraction (SPME))

  • 박교범;이석근
    • 분석과학
    • /
    • 제13권3호
    • /
    • pp.277-281
    • /
    • 2000
  • 16종의 휘발성 유기화합물을 blank water에 첨가하고 고정상으로 $100{\mu}m$ polydimethyl siloxane을 입힌 solid phase microextraction(SPME) fiber를 사용하는 headspace SPME방법으로 추출하여 gas chromatography/mass spectrometry (GC/MS)로 분석하였다. 이 방법의 평균회수율은 97%, 평균상대표준편차는 4.7%, 그리고 검출한계는 $0.01-0.5{\mu}g/l$를 나타냈다. 즉 SPME 방법을 이용한 수용액 중의 휘발성 유기화합물의 결과는 현재 많이 사용되고 있는 기존의 다른 방법보다 우수하고 편리한 방법으로 나타났다.

  • PDF

열탈착-저온농축-GC/FID/FPD에 의한 도시 생활폐기물 매립장에서 방출되는 휘발성 유기화합물의 측정에 관한 연구 (Determination of Volatile Organic Compounds emitted from Municipal Solid Waste Landfill Site by Thermal Desorption-Cryofocusing-GC/FID/FPD)

  • 김만구;정영림;서영민;남성현;권영진
    • 분석과학
    • /
    • 제14권3호
    • /
    • pp.274-285
    • /
    • 2001
  • 본 연구는 ppb와 ppt 정도의 농도 수준으로 존재하고 있는 대기 중 휘발성 유기화합물을 분석하기 위해 열탈착-저온농축-GC/FID/FPD를 개발하였다. 그리고 고체흡착제가 충진된 흡착관과 자체 제작한 휴대용 가스채취기를 사용하여 강원도 춘천지역에 위치한 근화동과 혈동리 생활폐기물 매립장에서 배출되는 VOCs를 채취하였다. 저온농축방법으로는 분석컬럼을 직접 저온 농축하는 on-column 저온 농축장치와 0.8mm loop를 이용한 저온농축장치를 서로 비교 검토해 보았다. On-column 저온농축법은 loop에 비해 분리능은 좋으나 흡착관에 채취한 시료를 저온농축할 때 요구되는 50 psi의 높은 탈착압력으로 인해 흡착관의 SwageLok fitting이 마모되어 가스가 새는 문제점이 발생하였다. 이에 반해 탈착압력을 낮추고 탈착유량을 늘리기 위해 설계한 loop 경우에는 탈착압력이 0.4 psi로 on-column에 비해 매우 낮아 가스가 새는 것을 방지할 수 있었다. 열탈착-저온농축-GC/FID/FPD로 분석한 근화동과 혈동리 생활폐기물 매립장에서 검출된 물질로는 toluene, xylene, ethylbenzene등 탄화수소류와 악취물인 styrene, limonene, dimethyl disulfide 등이 검출되었다. 그리고 매립지에서 방출되는 VOCs는 매립되는 폐기물의 조성과 매립기간에 따라 다르게 나타났다. 검출된 화합물은 저온농축-GC/MS를 이용하여 확인하였다.

  • PDF

고농도 Out Gas 정량 분석법 개발

  • 김민주;김종윤;정기호;박창식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.13-13
    • /
    • 2009
  • 본 연구는 MLCC 구성성분의 증발/비등에 의한 저분자물질의 제거가 bar 수축에 미치는 영향도를 평가하기 위해, 압착 bar에서 발생하는 고농도의 out gas를 정량하기 위한 최적 system을 구축하고자 하였다. gas 포집에 범용적으로 사용하는 Purge & Trap sampler 대신 Heating block를 사용하여 gas를 발생시키고 동시에 solvent에 용해시킴으로써 고농도의 시료가 희석될 수 있는 전처리 장치를 디자인하였다. 그 결과 고농도 gas 주입에 의한 장비오염과 peak saturation 문제가 해결되었고, gas phase의 시료를 liquid phase로 상전이 시켜 autosampler를 이용한 정확한 량의 시료 주입이 가능하였다. System의 Gage Linearity와 Bias는 각각 1.7%와 1.3%로 개선이 필요없는 수준의 정확도를 가졌다.

  • PDF

Volatile Flavor Components in Pumpking Vinegar

  • Hur, Sung-Ho;Lee, Wonkoo
    • Preventive Nutrition and Food Science
    • /
    • 제3권2호
    • /
    • pp.119-122
    • /
    • 1998
  • Pumpkin venegar was produced using autoclaved pumpkin juice by fermenting with cetobacter starter and ethanol at the ratio of 4 % and 10% to the volume of pumpkin juice, respectivley. Fermentation was carried out at 2$0^{\circ}C$ for 14 days followed by aging at 1$0^{\circ}C$ for 14 days. Flavor components of pumpkin vinegar was determined using GC/MS. Identified components, were 2 aldehydes (4.74%), 5 acohols (30.06%), 4 ketones (8.99%), 4 acids (16.39%), 5 alkanes (11.10%), 11 miscellaneous compounds (27.01%) and 9 unknown compounds (1.71%). Pumpkin vinegar showed very similar flavor characteristics to those of conventional wien vinegar and sherry wine vinegar in particular , acetioin, methyl acetate, and butanoic acid were typical volatile components of these three kinds of vinegar. Pumpkin vinegar showed possiblity to compete with European wine vinegar.

  • PDF

Saccharomyces와 Hansenula의 혼합배양에 의해 제조한 민속증류수의 향미특성 (Flavor Characteristics of Korean Traditional Distilled Liquors Produced by the Co-culture of Saccharomyces and Hansenula)

  • 홍연;박승국;최언호
    • 한국미생물·생명공학회지
    • /
    • 제27권3호
    • /
    • pp.236-245
    • /
    • 1999
  • Andong Soju is a Korean traditional distilled liquor brewed with Nuruk which is cultured with wild microorganisms. To provide useful information for scientific production and systematic quality control of traditional distilled liquor, the effects of mixed culture of the alcoholic yeasts and saccharifying molds isolated from the Nuruk, and mashes on the flavor and sensory characteristics were investigated. Distillate from mashes cocultured with Saccharomyces cerevisiae and Hansenula anomala using Mucor Nuruk was compared with distillate from mashes brewed with Andong Nuruk and with distillate from plant fermented mashes to analyze their flavor characteristics. The volatile flavor compounds in distillates were analyzed by GC and GC-MS using direct injection, solvent extraction, and purge & trap methods. Alcohols such as 3-methyl-1-butanol, 2-methyl-1-propanol, 1-propanol, and 2-phenyl ethanol; aldehydes such as acetaldehyde and 2-furancar-boxaldehyde; esters such as ethyl ester of acetic acid, hexanoic acid, octanoic acid, decanoic acid; alkanes, alkenes, ketone, sulfur, and pyrone compounds were detected. Alcohols were chief components of flavor compounds. No significant difference in overall acceptability test was shown among three experimental groups(p<0.05), but Nuruk-like aroma, Kaoliangchiew-like aroma, sweet taste, and well rounded mouthfeel showed significant differences among them(p<0.05).

  • PDF