• Title/Summary/Keyword: purge

Search Result 297, Processing Time 0.042 seconds

Volatile Components of Green Tea(Camellia sinensis L. var. Yabukita) by Purge and Trap Headspace Sampler (Purge와 Trap Headspace Sampler를 이용한 녹차의 휘발성 성분)

  • 이재곤;권영주;장희진;곽재진;김옥찬;최영현
    • The Korean Journal of Food And Nutrition
    • /
    • v.10 no.1
    • /
    • pp.25-30
    • /
    • 1997
  • Volatile components of green tea were isolated by purge and trap headspace method and were analyzed by GC and GC/MSD. And ten headspace volatiles were compared with volatiles isolated by simultaneous distillation-extraction(SDE) method. A total of 99 components were identified in the green tea volatile components, from which 88 components were identified in the headspace volatiles, contained 20 alcohols, 30 hydrocarbons, 21 aldehydes, 10 ketones, 2 acids and 5 miscellaneous components. The major components were low boiling components, such as methyl butanal(3.1%), 1-penten-3-ol(5.48%), 2-penten-1-ol(2.89%), hexanal(5.77%), heptanal(1.90%), and ere 2,4-eptadienal(4.28%), linalool(2.27%), 2,6-dimethyl cyclohexanol(2.57%), $\alpha$-pinene(1.52%), caryophyllene(1.70%), and carbonyl compounds, such as $\alpha$-ionone(2.62%), $\beta$-ionone(2.98%), $\beta$-cyclocitral(2.0%). On the other hand SDE volatiles, from which 64 components were identified, contained 16 alcohols, 16 ydrocarbons, 15 aldehydes, 10 ketones, 3 acids and 4 miscellaneous components. The major components were alcohols, such as, benzyl alcohol(3.79%), linalool(9.52%), terpineol(2.16%), geraniol(2.75%), nerolidol(6.50%), ketones, such as $\alpha$-ionone(1.77%), $\beta$-ionone(4.80%), geranyl acetone(1.82%) and acids, such as hexanoic acid(1.45%), nonanoic acid(1.11%).

  • PDF

HMC 엔진의 전자제어 시스템 소개

  • 장익순;이재곤
    • Journal of the KSME
    • /
    • v.32 no.10
    • /
    • pp.876-882
    • /
    • 1992
  • 여기에서는 삼원촉매 장착엔진을 정밀하게 제어(연료 제어, 공회전 제어, 점화시기 제어, Purge Air 제어 등)하여 삼원촉매의 효율을 향상시키고, 그 결과 배기가스를 감소시킴과 더불어 운전성 및 동력성능을 향상시킨 엔진 전자 제어 시스템의 개요를 간단히 소개하였다. 앞으로도 북미지 역의 배기가스 관련법규가 더욱 강화될 것으로 예상되며, 이에 대응한 엔진 제어 시스템에 대한 지속적인 연구 개발이 필요하리라 생각된다.

  • PDF

Review on the Process Safety of $SiH_{4}$ Gas used in Semiconductor and FPD Field (반도체 및 FPD 분야에 사용되는 $SiH_{4}$ 가스의 공정 안전 고찰)

  • Kim, Joung-Cho;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.4
    • /
    • pp.32-36
    • /
    • 2007
  • When the vacuum system for the process of $SiH_{4}$ gas used in the semiconductor and FPD field is partially vented from vacuum to atmospheric state, a fire often occurs due to auto-ignition of $SiH_{4}$ gas. In order to prevent the fire, the concentration of $SiH_{4}$ should be kept under LFL. This means that the higher capacity pump is needed to meet the process conditions as well as the condition that the concentration of $SiH_{4}$ should be kept under LFL. In this article, we conducted the injection of the dilution gas at the manifold between booster pump and dry pump compared with the typical method that the dilution gas was injected into inlet port of booster pump using computer simulation. According to the result, we can flow further more purge gas for safety without any change of the condition in the process chamber, which means that the higher capacity pump is not required for safety in some cases.

Analytical Method of Epichlorohydrin in Canned Beverages by Purge-and- Trap/GC

  • Lee Kwang-Ho;Kwak In-Shin;Kim Dyoung-Il;Choi Byoung-Hee;Kim Guy-Joung;Lee Chul-Won
    • Proceedings of the Korean Society of Food Hygiene and Safety Conference
    • /
    • 2001.10a
    • /
    • pp.140-140
    • /
    • 2001
  • A sensitive analytical method based on gas chromatograpy-mass spectrometry with a selected ion monitoring (GC/MS-SIM) with the purge-and-trap concentration and with headspace method (in limited applications) was developed for determining of epichlorohydrin in canned beverages coated with epoxy resin. The calibration curve in the range of $0.5\sim50ng$ had correlation coefficient greater than 0.998 and a detection limit of $0.l\mug/L$ was obtained using a sample volume of 20ml. The predominant ions of epichlorohydrin produced in MSD using electron ionization(EI) were m/z 57 ([M-CI]+) and 62/64 $([M-CH_2O]+)$. In survey of epichlorohydrin in thirty commercial canned beverage samples, none of them was detected.

  • PDF

Design of Hydrogen Peroxide/Kerosene Ignitor and Ignition Characteristic according to Operation Condition (친환경 추진제를 사용하는 액체로켓엔진 점화기의 설계 및 운용 조건이 점화 특성에 미치는 영향)

  • Hwang, Oh-Sik;Kim, Tae-Woan;Jeon, Jun-Su;Ko, Young-Sung;Kim, Yoo;Kim, Sun-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.74-77
    • /
    • 2009
  • Ignition performance tests were performed to develop a catalytic ignitor which used hydrogen peroxide and kerosene. Ignition characteristics were investigated by exit area of the catalytic bed, shape of kerosene injector and lead time of purge gas. The results showed that exit area of catalytic bed must be enough for non chocking condition and kerosene must be sprayed with swirl in the middle of catalytic bed. Also in case without preheating of catalytic bed, hydrogen peroxide must be leaded by 3sec, and purge gas must be supplied simultaneously or lately with kerosene.

  • PDF

A Study on the Research of Analytical Method for 1,4-Dioxane in Water (1,4-Dioxane의 분석방법 연구)

  • Park, Sun-Ku;Kim, Tae-Ho;Rim, Yeon-taek;Myung, Nho-Il
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.549-563
    • /
    • 2005
  • The study was carried out to develop and standardize the analytical method of 1,4-dioxane in water. The National Institute of Environmental Research in Korea has monitored for 1,4-dioxane in water since 1998 and it has been detected in environmental water occasionally. But the environmental pollution and analytical method in water is not well known over the world. The trace analytical method at low-${\mu}/L$ level is prerequisite in order to evaluate the residue of 1,4-dioxane in water. Evaluation of the method was demonstrated by comparing and analyzing with liquid-liquid extraction, solid-phase extraction and purge & trap technique. As a result of experiment by standard solutions and raw samples, the precision and accuracy for three methods were obtained within error rate of about 10%. Therefore, three methods were standardized as official monitoring method in Korea. Also, a convenient and simple liquid-liquid extraction method for the analysis of 1,4-dioxane in water was developed by combined with gas chromatography/mass spectrometry and applied to the water samples in Korea

Decomposition of volatile aromatic compounds by photochemical treatment (광화학적 방법을 이용한 휘발성 방향족 화합물의 분해)

  • Kim, Jong Hyang
    • Clean Technology
    • /
    • v.4 no.1
    • /
    • pp.35-44
    • /
    • 1998
  • Photodecomposition behaviors of volatile organic compounds (VOCs ; benzene, toluene, ethylbenzene and xylenes) over UV irradiation and UV irradiation with $TiO_2$ powder catalyst were studied and the extent of degradation were also investigated under various reaction conditions. The reactions were conducted in a quartz annular reactor equipped with a medium pressure mercury lamp. As a result, the extents of degradation were 92% for toluene and ethylbenzene, 83% for benzene, and 82% for xylenes under UV irradiation. And they were 92% for toluene, 82% for xylene and ethylbenzene, and 53% for benzene under UV irradiation with $TiO_2$ powder. Analyses of reacted samples by FID-gas chromatograph with Purge & Trap concentrator and GC-MS indicated that the aromatics formed many intermediates.

  • PDF