Journal of the Korea Society of Computer and Information
/
v.17
no.2
/
pp.31-40
/
2012
Iris recognition is a biometric technology which can identify a person using the iris pattern. It is important for the iris recognition system to extract the feature which is invariant to changes in iris patterns. Those changes can be occurred by the influence of lights, changes in the size of the pupil, and head tilting. In this paper, we propose a novel method based on Zernike Moment which is robust to rotations of iris patterns. we utilized a selection of Zernike moments for the fast and effective recognition by selecting global optimum moments and local optimum moments for optimal matching of each iris class. The proposed method enables high-speed feature extraction and feature comparison because it requires no additional processing to obtain the rotation invariance, and shows comparable performance to the well-known previous methods.
A coelostat is often used for solar observations, because it corrects the image rotation automatically by guiding sunlight into a fixed telescope with two plane mirrors. For the purposes of education and spectroscopic observation, the solar group at Seoul National University (SNU) plans to develop the SNU coelostat (SNUC) and install it in the SNU Astronomical Observatory (SAO). Requirements of the SNUC are < 1" positioning accuracy with 30 cm beam size on the entrance pupil in the compact dome. To allow for installation in the small dome, we design a compact slope type coelostat with a 45 cm primary plane mirror and a 39 cm secondary plane mirror. The motion of the SNUC is minimized by fixing the position of the slope frame. Numerical simulations of the available observational time of the designed coelostat shows that the sun can be observed ay all times from June to early August and at least three hours in other months. Since the high accuracy driving motors installed in the SNUC can be affected by external environment factors such as humidity and temperature variations, we design a prototype to test the significance of these effects. The prototype consists of a 20 cm primary plane mirror, a 1 m slope rail, a direct drive motor, a ballscrew, a linear motion guide, an AC servo motor, a reduction gear and a linear encoder. We plan to control and test the accuracy of the prototype with varying atmospheric conditions in early 2019. After testing the prototype, the SNUC will be manufactured and installed in SAO by 2020.
Park, Seung Won;Choi, Jun won;Kim, Tae Hyun;Seo, Jeong Hun;Jeong, Myeon Gyu;Lee, Kang In;Kim, Han Sung
Journal of Biomedical Engineering Research
/
v.43
no.1
/
pp.27-34
/
2022
Drunk driving defines a driver as unable to drive a vehicle safely due to drinking. To crack down on drunk driving, alcohol concentration evaluates through breathing and crack down on drinking using S-shaped courses. A method for assessing drunk driving without using BAC or BrAC is measurement via biosignal. Depending on the individual specificity of drinking, alcohol evaluation studies through various biosignals need to be conducted. In this study, we measure biosignals that are related to alcohol concentration, predict BrAC through SVM, and verify the effectiveness of the S-shaped course. Participants were 8 men who have a driving license. Subjects conducted a d2 test and a scenario evaluation of driving an S-shaped course when they attained BrAC's certain criteria. We utilized SVR to predict BrAC via biosignals. Statistical analysis used a one-way Anova test. Depending on the amount of drinking, there was a tendency to increase pupil size, HR, normLF, skin conductivity, body temperature, SE, and speed, while normHF tended to decrease. There was no apparent change in the respiratory rate and TN-E. The result of the D2 test tended to increase from 0.03% and decrease from 0.08%. Measured biosignals have enabled BrAC predictions using SVR models to obtain high Figs in primary and secondary cross-validations. In this study, we were able to predict BrAC through changes in biosignals and SVMs depending on alcohol concentration and verified the effectiveness of the S-shaped course drinking control method.
Background: Rocuronium bromide has been evaluated as a mydriatic agent in birds, but the species applied were limited and the dose and effect were variable. Objective: This study aims to evaluate the efficacy of topical rocuronium bromide as mydriatics in 4 species according to horizontal palpebral fissure length: Feral pigeon (Columba livia), Common kestrel (Falco tinnunculus), Northern boobook (Ninox japonica), and Eurasian eagle owl (Bubo bubo). Methods: A total of 32 birds (8 for each species) were included as pre-releasing examination. Rocuronium bromide was instilled in one randomly selected eye of each bird based on palpebral fissure length criteria (0.5 mg/50 µL for pigeons, 1 mg/100 µL for kestrels and boobook owls, and 2 mg/200 µL for eagle owls). The contralateral eye was used as control and treated with normal saline. After instillation of the drug, pupil diameter, pupillary light reflex, intraocular pressure, heart rate, and respiratory rate were evaluated at 10 min intervals up to 180 min and at 30 min intervals up to 360 min. Results: Statistically significant mydriasis was obtained in all birds (p < 0.001). However, in boobook and eagle owls, marked mydriasis persisted until 360 min. Side effects including corneal erosion and lower eyelid paralysis were common, which was observed in 26/32 birds. Blepharospasm was also noted during this study. No systemic adverse signs were observed. Conclusions: Rocuronium bromide could be a good mydriatics option for 4 species of birds, however, further studies are needed to find lowest effective dose to reduce drug-related side effects.
Journal of the Korean Institute of Landscape Architecture
/
v.43
no.4
/
pp.87-97
/
2015
There's a trend towards vitalization of nightscape planning businesses nationally and locally as well for city image making and activation of regional economy, but there is still no systematic nightscape planning going on for lack of relevant researches and objective evaluations. This study aims to suggest the guideline for nightscape planning by conducting an eye tracking experiment and survey for recognizing the characteristics of a nightscape. Furthermore, the authors intended to verify the eye-tracking method as a tool for landscape evaluation. The research site was restricted in the campus of Virginia Tech, VA, and those were selected by experts' survey among various types of nightscape images. The variables for analyzing the characteristics of nightscape images selected were 'preference', 'safety(fear)' and 'clearness'. 'Fixation duration', 'saccade duration', 'scan path length', and 'pupil size' were selected as the eye movement measurements. The results of this study are as follows: The first outcome found was that there were significant differences among the characteristics(preference, safety and clearness) of a nightscape by MANOVA, and these variables were correlated positively by Pearson's correlation. Secondly, there were differences on fixation duration, saccade duration and scan path depending on the nightscape setting statistically. Also, the eye tracking measurement in an open setting was recorded lower than enclosed settings. In the result of a heat map, we found the meaning of the fixated areas on both viewing without intention and viewing intentionally. It turned out that the fixated areas were consistent with the areas the subjects felt preferred and clarity in all of the nightscape images, which means people usually focus on what they prefer and see clearly in a certain nightscape. Based on this result and previous studies, the authors could make a conclusion that eye tracking method can apply to evaluate nightscape settings in terms of analyzing the whole characteristics and finding specific points for the detailed analysis as well. Therefore, these results can contribute by suggesting nightscape planning, implication of the landscape evaluation, and implication of the eye tracking study.
Purpose: This study was to investigate the relevance between refractive and anatomical changes temporarily on the eyes after alcohol ingestion. Methods: Eight subjects (16 eyes) which were $24.5{\pm}1.5$ aged males drunk the alcohol of 0.42 g per kg of body weight within 30 minutes. Refractive errors, the radius of corneal curvature, corneal thickness, pupillary size, intraocular pressure, and the length of the ocular axis at 1 h, 4 h, and 24 h after alcohol ingestion were compared with them of non-alcoholic state. Results: At 1 h after alcohol ingestion, breath alcohol concentration was the highest (p<0.001), more negative spherical power was needed (p<0.05) for correction, pupillary diameter was decreased (p<0.05), intraocular pressure was decreased (p<0.001), and the length of the ocular axis was increased compared with each one of non-alcoholic state. At 4 h after alcohol ingestion, all anatomical changes were the same tendency as at 1 h after alcohol ingestion. But at 24 h after alcohol ingestion, both refractive changes and anatomical changes were not significant compared with them of non-alcoholic state. Conclusions: Temporary changes of refractive error after alcohol ingestion may be related with decrease of intraocular pressure and increase of the length of ocular axis.
Objective: Traumatic epidural hematomas (EDHs) in children are a relatively unusual occurrence. The cause and outcome vary depending on period and reg ion of study. The aims of this analysis were to review the cause and outcome of pediatric EDHs nowadays and to discuss outcome-related variables in a large consecutive series of surgically treated EDH in children. Methods: This is a retrospective review of 29 patients with surgically treated EDHs between Jan 2000 and February 2010. Patients' medical records, computed tomographic (Cl) scans, and, if performed, magnetic resonance imaging (MRI) were reviewed to define variables associated with outcome. Variables included in the analysis were age, associated severe intracranial injury, abnormal pupillary response, hematoma thickness, severity of head injury (Glasgow Coma Scale score), parenchymal brain injury, and diffuse axonal injury. Results: The mean (SO) age of the patients was 109 months (0-185 months). Most of the injuries with EDHs occurred in traffic accident (14 cases, 48.2%) and followed by slip down in 6 cases and falls in 6 cases. There were one birth injury and one unknown cause. EDHs in traffic accidents occurred in pedestrians hit by a motor vehicle, 9 cases; motorbike and car accidents, 5 cases and bicycle accidents, 1 case. The locations of hematoma were almost same in both sides (left side in 15 cases). Temporal lobe is the most common site of hematomas (13 cases, 44%). The mean size of the EDHs was 18 mm (range, 5-40 mm). Heterogeneous hematomas in CT scans were 20 cases (67%). Two patients were referred with unilateral or bilateral dilated pupil(s). There was enlargement of EDH in 5 patients (17%). All of them were heterogeneous hematomas in CT scans. Except for 4 patients, all EDHs were associated with skull fracture(s) (87%). There was no case of patient with major organ injury. CT or MRI revealed brain contusion in 5 patients, and diffuse axonal injury in one patient The mortality was zero, and the outcomes were excellent in 26 and good in 2 patients. None of the tested variables were found to have a prognostic relevance. Conclusion: Regardless of the EDH size, the clinical status of the patients, the abnormal pupillary findings, or the cause of injury, the outcome and prognosis of the patients with EDH were excellent.
Park, Chan;Yuk, In-Soo;Chun, Moo-Young;Pak, Soojong;Kim, Kang-Min;Pavel, Michael;Lee, Hanshin;Oh, Heeyoung;Jeong, Ueejeong;Sim, Chae Kyung;Lee, Hye-In;Le, Huynh Anh Nguyen;Strubhar, Joseph;Gully-Santiago, Michael;Oh, Jae Sok;Cha, Sang-Mok;Moon, Bongkon;Park, Kwijong;Brooks, Cynthia;Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyuong;Hill, Peter C.;Lee, Sungho;Barnes, Stuart;Park, Byeong-Gon;T., Daniel
The Bulletin of The Korean Astronomical Society
/
v.39
no.1
/
pp.52.2-52.2
/
2014
The Immersion Grating Infrared Spectrometer (IGRINS) is an unprecedentedly minimized infrared cross-dispersed echelle spectrograph with a high-resolution and high-sensitivity optical performance. A silicon immersion grating features the instrument for the first time in this field. IGRINS will cover the entire portion of the wavelength range between 1.45 and $2.45{\mu}m$ accessible from the ground in a single exposure with spectral resolution of 40,000. Individual volume phase holographic (VPH) gratings serve as cross-dispersing elements for separate spectrograph arms covering the H and K bands. On the 2.7m Harlan J. Smith telescope at the McDonald Observatory, the slit size is $1^{\prime\prime}{\times}15^{\prime\prime}$. IGRINS has a $0.27^{\prime\prime}$ pixel-1 plate scale on a $2048{\times}2048$ pixel Teledyne Scientific & Imaging HAWAII-2RG detector with SIDECAR ASIC cryogenic controller. The instrument includes four subsystems; a calibration unit, an input relay optics module, a slit-viewing camera, and nearly identical H and K spectrograph modules. The use of a silicon immersion grating and a compact white pupil design allows the spectrograph collimated beam size to be 25mm, which permits the entire cryogenic system to be contained in a moderately sized rectangular vacuum chamber. The fabrication and assembly of the optical and mechanical hardware components were completed in 2013. In this presentation, we describe the major design characteristics of the instrument and the early performance estimated from the first light commissioning at the McDonald Observatory.
Purpose: To compare corneal asphericity, visual acuity (VA), and ocular and corneal higher-order aberrations (HOAs) between myopic refractive surgery and emmetropia groups. Methods: Twenty three subjects ($23.0{\pm}2.5$ years) who underwent myopic refractive surgery and twenty emmetropia ($21.0{\pm}206$ years) were enrolled. The subjects'criteria were best unaided monocular VA of 20/20 or better in both two groups. High and low contrast log MAR visual acuities were measured under photopic and mesopic conditions. Corneal and ocular HOAs were measured using Wavefront Analyzer (KR-1W, Topcon) for 4 mm and 6 mm pupils. Corneal asphericity was taken by topography in KR-1W. Results: There was no significant difference in VA between two groups under either photopic or mesopic conditions. In ocular aberrations, there were significant differences in total HOAs, fourthorder and spherical aberration (SA) for a 6 mm between two groups (p=0.045, p<0.001, and p<0.001, respectively). In corneal aberrations, there was a significant difference in SA for 4 mm (p=0.001) and 6 mm (p<0.001) pupils between two groups and there were statistically significant differences in total HOAs (p<0.001) and fourth-order aberrations (p<0.001) between two groups for a 6 mm pupil. There was a significant correlation in emmetropia between Q-value and SA in ocular aberrations for 4 mm and 6 mm pupils (r=0.442, p=0.004, and r=0.519, p<0.001) and in corneal aberrations for 4 mm and 6 mm pupils (r=0.358, p=0.023, and r=0.646, p<0.001). No significant correlations were found between Q-value and SA in refractive surgery group. Conclusions: VA in myopic refractive surgery is better than or similar to emmetropia. Nevertheless, the more increasing pupil size is, the more increasing aberrations are. Thus, it could have an influence on the quality of vision at night.
Kim, Jeong Mee;Mun, Mi-Young;Kim, Young Chul;Lee, Koon-Ja
Journal of Korean Ophthalmic Optics Society
/
v.17
no.4
/
pp.365-372
/
2012
Purpose: To investigate ocular higher order aberrations (HOA) and spherical aberration changes caused by an aspheric soft contact lens designed to reduce spherical aberration (SA) of the eye. Methods: Fifty subjects who have successfully experienced soft contact lenses were refitted with aspheric design (Soflens Daily Disposable: SDD, Bausch+Lomb) soft contact lens. Ocular higher order aberrations (HOA) and stand alone SA were measured and analyzed for a 4-mm pupil size using Wave-Scan Wavefront$^{TM}$ aberrometer (VISX, Santa Clara, CA, USA). High and low contrast log MAR visual acuity and contrast sensitivity function (CSF) were also measured under photopic and mesopic conditions (OPTEC 6500 Vision Tester$^{(R)}$). All measurements were conducted monocularly with an undilated pupil. Results: The RMS mean values for total HOA with SDD contact lenses were significantly lower than those at with unaided eyes (p<0.001) and a reduction for SA in the SDD was close to the baseline SA (zero ${\mu}m$) (p<0.001). For the SDD lens, there was a statistically significant correlation between the changes in the total HOA and the contact lens power (r=0.237, p=0.018) as well as between the changes in SA and the lens power (r=0.324, p=0.001). High contrast visual acuity (HCVA) and low contrast visual acuity (LCVA) with SDD lenses were $-0.063{\pm}0.062$ and $0.119{\pm}0.060$, respectively under photopic and $-0.003{\pm}0.063$ and $0.198{\pm}0.067$, respectively under mesopic condition. Contrast Sensitivity Function (CSF) with SDD lenses under both photopic and mesopic conditions was $3.095{\pm}0.068$ and $3.087{\pm}0.074$, respectively. Conclusions: The SDD contact lens designed to control SA reduced the total ocular HOA and SA of the eye, resulting in compensating for positive SA of the eyes. Thus, the optical benefits of the lens with SA control would be adopted for improving the quality of vision.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.