• Title/Summary/Keyword: punching behavior

Search Result 99, Processing Time 0.028 seconds

A Remote SNMP Connection Request Mechanism for NATed Devices using UDP Hole Punching and Heuristic Hole Binding Time Search (UDP 홀 펀칭과 경험적 홀 유지시간 탐색을 이용한 NAT 환경단말의 SNMP 원격 접속요청 메커니즘)

  • Park, Choon-Gul;Kim, Seong-Il;Jeong, Ki-Tae;Lee, Young-Seok
    • Journal of KIISE:Information Networking
    • /
    • v.35 no.5
    • /
    • pp.367-373
    • /
    • 2008
  • Recently, the NAT middlebox widely deployed in the home network environment prohibits DM operations from reaching user devices behind NAT. In this article, we focus on NAT issues to manage home network devices. Particularly, we discuss standardization efforts, and present our proposal to deploy DM services for VoIP and IPTV devices under NAT. By slightly changing behaviors of Simple Network Management Protocol (SNMP) Manager and Agent, and defining additional Management Objects (MOs) to gather NAT binding information, we could solve the NAT traversal problem under symmetric NAT. Moreover, we propose an enhanced method to search the UDP hole binding time of the NAT box. We applied our method to randomly selected 22 VoIP devices out of 194 NATed hosts in the real broadband network and have achieved 99% of the success ratio for exchanging SNMP request messages and 26% of enhancement for searching the UDP hole binding time.

Punching Shear Behavior of High-strength Lightweight Concrete Slab Under Concentrated Load (집중하중을 받는 고강도 경량콘크리트 바닥판의 펀칭전단 거동)

  • Cho, Sun-Kyu;Kwark, Jong-Won;Lee, Jong-Min;Moon, Dae-Joong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1A
    • /
    • pp.219-228
    • /
    • 2006
  • Because of the advantage of light weight, lightweight concrete is frequently applied to long-span bridges and high-rise buildings. In the country, there is not enough experience for the long-span bridges using lightweight concrete. This paper presents results of an experimental study on the punching shear strength of high-strength lightweight concrete slabs. Four test slabs are fabricated using high-strength lightweight concrete and normalweight concrete and at the center of the test slabs, simulated wheel load is applied until failure. The compressive strengths of lightweight concrete and normalweight concrete are 47MPa and 32MPa, respectively. The test results show the failure mode of all specimens are punching shear and the behaviors of high-strength lightweight concrete slabs are very similar to that of normalweight concrete slabs. Based on the test results, it is discussed the safety and serviceability of high-strength lightweight concrete bridge decks.

Behavlor of Ontarlo-Type Skew Bridge Decks (온태리오형 교량상판의 거동에 관한 연구 (사교의 경우))

  • 김긍환
    • Magazine of the Korea Concrete Institute
    • /
    • v.2 no.1
    • /
    • pp.101-108
    • /
    • 1990
  • An experimental and analytical invest.igation was conducted regarding the behavior of reinforced concrete skew bridge decb with Ontario-type reinforcement. A full-scale model repmsenting the essential behavior of a full skew bridge was built and tested. The test specimen had details similar to those required by the Ontario Highway Bridge Design Code, modified as recommended by the Texas State Highway Dopartment. The skuw bridge deck performed sati:,factorily under the current AASHTO design load le"els as well as the overload conditions(about :3 times the current AASHTO design wheel load). The skew edges failed by shear ; the center by punching shear. The calculated flexural capacity considering arching action always far exceeded the actual failure load (shear or punching shear) at each test location. To check the experimental results a detailed finite element model of the specimen was developed using a general-purpose structural analysis pmgram. Analytical predictions and exper'imental results agreed c1osuly.

Pre-fatigue Damage of the Strengthened Bridge Deck for Study on Fatigue Behavior (피로거동파악을 위한 성능향상된 교량상판의 사전피로손상의 고찰)

  • 심종성;오홍섭;김진하
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.697-700
    • /
    • 2000
  • Fatigue damage to reinforced concrete bridge decks have been found in many bridges. Failure mode of most reinforced concrete decks is caused by local punching shear rather than flexural moment due to cumulated damage. In this study, mechanical degradation of unstrengthened and strengthened bridge deck specimens is experimentally investigated. The unstrengthened deck specimens were damaged under the pulsating loading condition. After the test, deteriorated deck specimens were strengthened with Carbon Fiber Sheet, then loaded to observe the improvement of the fatigue behavior. It is shown that fatigue damaged specimens are similar to real bridge rather than static damaged specimens.

  • PDF

Punching Shear Strength of Reinforced Concrete Slabs Subjected to Biaxial In-plane Tension (면내2축인장력을 받는 철근콘크리트슬래브의 펀칭전단강도)

  • Mo, Gui-Seok;Kim, Dae-Jung;Kim Woo
    • Magazine of the Korea Concrete Institute
    • /
    • v.2 no.3
    • /
    • pp.73-80
    • /
    • 1990
  • This research program is directed at studying the behavior and the strength of reinforced concrete slabs sub¬jected to certain combination of punching shear and in-plane tension. Major variables to be investigated are the shear span to depth ratio of reinforced concrete slabs and the degree of the in-plane tensile force which is act¬ing tangent to the slabs. The experimental results are used for understanding of the degree of tbe interaction between the two loadings, and for developing a new practical design equation.

Punching Shear Behavior of High-Performance Steel Reinforced Two-Way Concrete Slabs (고성능 철근으로 보강된 2방향 콘크리트 슬래브의 펀칭전단거동)

  • Yang, Jun-Mo;Lee, Joo-Ha;Shin, Hyun-Oh;Kook, Kyung-Hun;Yoon, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.75-76
    • /
    • 2010
  • Two-way slabs reinforced with high-performance steels were constructed and tested. The influences of the yield strength of flexural reinforcements, the flexural reinforcement ratio, and concentrating the reinforcement in the immediate column region on the punching shear resistance, post-cracking stiffness, strain distribution, and crack control were investigated.

  • PDF

Ductility of Column-Slab eoint in R/C Flat Plate System (플랫 플레이트 구조의 기둥.슬래브 접합부 연성에 관한 연구)

  • 김형기;박복만
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.4
    • /
    • pp.113-119
    • /
    • 2000
  • The R/C flat plate system provides architectural flexibility, clear space, reduced building height, simple formwork, which consequently enhance constructibility. One of the serious problems in the flat plate system is brittle punching shear failure due to transfer of shear force and unbalanced moments in column-slab joint. Recently, the flat plate system accompanied with shear walls to resist the lateral loads is applied to high-rise buidings. Although the flat plate system is not considered in design as part of the lateral load-resisting system, it is required that this system keeps the ductile behavior for the lateral displacement of the building. However, it is unclear whether the column-slab joint possesses ductility enough to survive the lateral deformation. The objective of this paper is to investigate the major parameters that influence the ductility of R/C flat plate system by examining the existing experiments on column-slab joint. The effects of gravity load and shear reinforcement on the ductility of the flat plate system are presented.

Punching Strength of Long-Span PSC Deck Slabs (장지간 PSC 바닥판의 정적펀칭강도)

  • Hwang Hoon Hee;Cho Chang Bin;Yoon Hye Jin;Kim Sung Tae
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.467-470
    • /
    • 2005
  • This study was performed to evaluate the static strength of long-span PSC deck slabs. In the previous study, the minimum thickness of PSC deck slabs in the composite two-girder bridge was proposed. To examine the structural behavior and safety of the PSC deck slabs designed in accordance with the proposed minimum thickness, 1/3 scaled PSC deck slabs in the composite two-girder bridge were tested under the static loading. The test results were compared with the predicted values proposed by the code and Matsui. Test results showed ultimate static strength of the PSC deck slabs designed in accordance with the proposed minimum thickness have enough margin of safety. The static failure mode of each test specimen was punching shear mode.

  • PDF

Structural Behavior of Post-Tensioned Flat Plate Slab-Column Connections (포스트 텐션 플랫 플레이트 슬래브 접합부의 거동)

  • Cho Kyung Hyun;Han Sang Whan;Lee Li-Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.53-56
    • /
    • 2004
  • Recently, post tension flat plate slab system is widely used for a new slab structural system. Slab-column connections may fail in brittle manner by punching shear. Flat plate slabs have been widely used for gravity load resisting system in buildings. Lateral resistance usually provided by shear walls or moment resisting frames. Since plat plates move together with lateral loading system during earthquake or wind, it is important to evaluate the gravity resistance under a drift experienced by lateral force resisting system during either design earthquake or wind. Thus, this study investigated post tension flat plate slab systems whether they have sufficient strength and deformability to resist gravity loads during specified drift levels. Experimental research was carried out.

  • PDF

Estimation of Critical Height of Embankment to Mobilize Soil Arching in Pile-supported Embankment (말뚝지지성토지반 내 지반아칭이 발달할 수 있는 한계성토고의 평가)

  • Hong, Won-Pyo;Hong, Seong-Won
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.11
    • /
    • pp.89-98
    • /
    • 2010
  • A method to design a critical height of embankments is presented so as to mobilize fully soil arching in pile-supported embankments. The behavior of the load transfer of embankment weights on pile cap beams was investigated by a series of model tests performed on pile-supported embankments with relatively wide space between cap beams. The model tests explained that the behavior of the load transfer depended very much on the height of embankments, because soil arching could be mobilized in pile-supported embankments only under enough high embankments. The measured vertical loads on cap beams coincided with the predicted ones estimated by the theoretical equations, which have been presented in the previous studies on the basis of load transfer mechanisms according to either the punching shear failure mode during low filling stage or the soil arching failure mode during high filling stage. The mechanism of the load transfer was shifted beyond a critical height of embankment from the punching shear mechanism to the soil arching mechanism. Therefore, in order to mobilize soil arching in pile-supported embankments, the embankments should be designed at least higher than the critical height. A theoretical equation to estimate the critical height could be derived by equalizing the vertical loads estimated by the load transfer mechanisms on the basis of both the punching shear and the soil arching. The derived theoretical equation could predict very well the experimental critical height of embankment.