• Title/Summary/Keyword: pumping reservoir

Search Result 66, Processing Time 0.027 seconds

Causes and Measures of Flood Damage ('99.8) in Imjin River Basin (임진강 유역 대홍수 ('99,8)의 피해 원인과 대책)

  • 김현영;이용직
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.454-458
    • /
    • 1999
  • This study is to analyze the causes of flood damage in Imjin river basin inAugust , 1999. and to propose the measure to reudce such flood damage. The northern part of Kyonggin Province in the basin was severely damaged by flood due to the heavy rainfall for 4 days from 31 July to 3 August, whioch was recordedas 1,032mm. The heavy rainfall worth recording was one of main cuasese of such damage, but unsuitable river improvement and basin management were also important causes. The flood proptection works such as flood control reservoir and riverlevee were not contructed or sufficient in spite of the unflavorable geographical conditions of Imjin reiver. In case of irrigatiion faciliteis, 43 pumping stations in 3 FIAs were severely damaged due to inundation of the pump and switch boxes. The protection works for pump room should be improved to reduce the damage due to inundation.

  • PDF

Methodology for Estimating Agricultural Water Supply in the Han River Basin (한강수계의 농업용수 공급량 조사방법의 개발)

  • Im, Sang-Jun;Park, Seung-U;Kim, Hyeon-Jun
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.6
    • /
    • pp.765-774
    • /
    • 2000
  • The purpose of this study are to develop a realistic methodology to estimate agricultural water supply for rice paddy fields from reservoirs, pumping stations, intake structures, and tube wells on river basin scale. Agricultural water supply from irrigation reservoirs are estimated using the daily or ten day's storage rate data and DIROMmaily Inigation Reservoir Operation Model) model. Estimation of daily water supply from pumping station are carried out from the annual water use with typical water supply patterns. The daily groundwater withdrawn are investigated from the gross water requirement for rice and the design capacity of tube well. And, the daily intake discharge are estimated the minimum amount from the gross water requirement, stream discharge, and the design capacity. During 1993 to 1997, the annual water supply for irrigation in the Han river basin ranged from 569 to 709 million $\textrm{m}^3/yr$, and the mean was estimated to be 640 million $\textrm{m}^3/yr$.

  • PDF

Modeling and Application of Chlorine Bulk Decay in Drinking Water Distribution System (배급수계통에서 잔류염소 감소 특성 및 적용연구)

  • Ahn, Jae-Chan;Park, Chang-Min;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.487-496
    • /
    • 2005
  • Chlorine bulk decay tests were carried out by bottle test under controlled conditions in a laboratory. Experiments were performed at different temperatures: $5^{\circ}C$, $15^{\circ}C$, $25^{\circ}C$, and the water temperatures when samples were taken from the effluent just before entering to its distribution system. 38 bulk tests were performed for water of Al (water treatment plant), 4 bulk tests for A2 (large service reservoir), and A3(pumping station). Residual chlorine concentrations in the amber bottles were measured over time till about 100 hours and bulk decay coefficients were evaluated by assuming first-order, parallel first-order, second-order. and $n^{th}-order$ reaction. The $n^{th}-order$ coefficients were obtained using Fourth-order Runge-Kutta Method. A good-fit by the average coefficient of determination ($R^2$) was first-order ($R^2=0.90$) < parallel first-order ($R^2{_{fast}}=0.92$, $R^2{_{slow}}=0.95$) < second-order ($R^2=0.95$) < $n^{th}-order$ ($R^2=0.99$). But if fast reaction of parallel first-order bulk decay were applied to the effluent of large service reservoir with ca. 20 hours of travel time and slow reaction in the water distribution system following the first 20 hours, parallel first-order bulk decay would be best and easy for application of water quality modeling technique.

Estimating generation capacity of geothermal power generation pilot plant project (우리나라 지열발전 pilot plant 프로젝트의 발전량 추정)

  • Song, Yoonho;Lee, Tae Jong;Yoon, Woon Sang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.197.1-197.1
    • /
    • 2011
  • Target generation capacity of geothermal power generation pilot plant project through the Enhanced Geothermal Systems (EGS) with a doublet system down to 5 km depth was estimated. Production and re-injection temperatures of geothermal fluid were assumed $160^{\circ}C$ and $60^{\circ}C$, respectively, based on reservoir temperature of $180^{\circ}C$ calculated from the geothermal gradient of $33^{\circ}C$ in Pohang area. In this temperature range, 0.11 of thermal efficiency of the binary generation cycle is a practical choice. Assuming flow rates of 40 kg/sec, which is possible in current EGS technology, gross power generation capacity is estimated to reach 1.848 MW. Net generation considering auxiliary power including pumping power for geothermal fluid and condensing (cooling) energy of working fluid can be 1.5 MW.

  • PDF

Development of Optimal Network Model for Conjunctive Operation of Water Supply System with Multiple Sources (다수원 상수도시스템 연계운영을 위한 최적 네트워크 모형 구축)

  • Ryu, Tae-Sang;Ha, Sung-Ryong;Cheong, Tae-Sung
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.12
    • /
    • pp.1001-1013
    • /
    • 2011
  • Development of an optimal water supply system considering water quantity, quality, and economical efficiency is needed to decide optimal available area by combine water supply systems in overlapped area where are more than 2 water sources. The EPAnet and the KModSim were coupled to develop optimal network model. The developed network model was calibrated by measured data from water supply system in Geoje City, Korea in 2007 which have three water sources such as Sadeong booster pumping station, Guchun dam reservoir and Yoncho dam reservoir. The optimum network model was validated by operating results of 2011 to assess the economically optimized service area and optimal pump combination under the given hydraulic operating rules developed in this study. The developed model can be applied into designing water supply systems and operating rules for the conjunctive operation since the model can give the optimal solution satisfied with water quantity, economical efficiency and quality.

Estimation of the Optimal Dredge Amount to Maintain the Water Supply Capacity on Asan-Lake (아산호 용수공급용량 유지를 위한 적정 준설량 산정)

  • Jang Tae-Il;Kim Sang-Min;Kang Moon-Seong;Park Seung-Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.2
    • /
    • pp.45-55
    • /
    • 2006
  • This study analyze the hydrologic conditions and the effects of selected runoff characteristics as an attempt to estimate the optimal dredge amount for Asan Lake in Korea. The runoff feature was calculated by utilizing the water balance simulation from DIROM (Daily Irrigation Reservoir Operation Model), which allowed changes in landuse to be quantified using remote sensing for 14 years. The distribution of prospective sediment deposits was been tallied based on the changes in landuse, and quantity of incoming sediment estimated. From these findings, we were then able to simulate the fluctuation of water level, gauging the pumping days not already in use, to determine the frequency of the distribution for around the. requirement annual water storage and the changing water level. The optimal dredge amount was calculated on the basis of the distribution of frequency, taking into account the design criteria for agricultural water with the 10-year frequency of resistant capacity.

Optimal Design of Thrust Surface Oil Groove of a High Side Scroll Compressor (고압식 스크롤 압축기 스러스트 오일 그루브 최적 설계)

  • Kim, Hyun-Jin;No, Young-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.127-133
    • /
    • 2017
  • Performance analysis has been carried out on a high side scroll compressor that had a fixed scroll equipped with a circular oil groove on its thrust surface. Oil was supplied to the oil groove through an intermittent opening from a high pressure oil reservoir formed inside the orbiting scroll hub. Oil in the groove was then delivered to both suction and back pressure chambers by pressure differentials and viscous pumping action of the orbiting scroll base plate. Mathematical modeling of this oil groove system was incorporated into a main compressor performance simulation program for an optimum oil groove design. The study findings were as follows. Pressure in the oil groove can be controlled by changing its configuration and the oil passage area. With an enlarged oil passage, the pressure in the oil groove heightens due to an increased flow rate, but the pressure elevation in the back pressure chamber is small, resulting in reduced friction loss at the thrust surface between the two scrolls. On the other hand, by increasing the oil passage area, the oil content in the refrigerant flow increases. Considering all these factors, the energy efficiency ratio could be improved by about 3.6% under the ARI condition by an optimal oil groove design.

Effects of reservoir and groundwater pumping on streamflow for Anseongcheon upper watershed (안성천 상류유역 하천유출에 미치는 농업용 저수지와 지하수 이용 영향 분석)

  • Lee, Jeongwoo;Kim, Nam Won;Chung, Il-Moon;Lee, Jeong Eun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.507-507
    • /
    • 2015
  • 본 연구에서는 안성천 공도 수위표 상류유역에 대해 농업용 저수지와 지하수 이용이 하천유량에 미치는 영향을 SWAT-MODFLOW 모형을 이용하여 모의 분석하였다. 대상유역내에 위치한 고 삼, 금광 농업용 저수지 영향을 고려하기 위해서 관개기에는 저수지 방류량이 관개수로를 통해 수리답 지역으로 보내져 작물소모에 의한 손실과 지표 및 지표하 유출 과정을 거쳐 하천으로 회귀되도록 하고, 비관개기에는 저수지가 만수가 될 경우에만 하천으로 저수지 방류가 일어나도록 처리하였다. 지하수 이용량은 유역내 위치한 허가 및 신고 관정을 대상으로 하였으며, 농업용 관정인 경우는 저수지 관개와 마찬가지로 작물소모에 의한 손실과 지표 및 지표하 유출 과정을 거쳐 하천으로 회귀되도록 처리하였고, 생공용 관정인 경우는 유역내에서 전량 소모되는 것으로 간주하였다. 저수지 및 지하수 양수 유무에 따른 하천유량을 모의한 결과 고삼 및 금광 저수지 직하류부에서는 저수지 영향이 지배적으로 작용하여 갈수량이 각각 약 40% 및 85% 만큼 감소하는 것으로 나타났다. 반면에 저수지로부터 보다 하류쪽로 가면서 회귀수의 영향으로 감소 영향이 둔화되는 양상을 보였으며, 유역출구부에서는 저수지 및 지하수 이용 영향으로 자연상태 유량에 비해 갈수량이 약 19% 만큼 감소하는 것으로 분석되었다.

  • PDF

Preliminary Hydrological Design for Sand Dam Installation at the Valley of Seosang-ri, Chuncheon (춘천 서상리 계곡부 샌드댐 설치를 위한 수문학적 예비 설계)

  • Chung, Il-Moon;Lee, Jeongwoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.725-733
    • /
    • 2019
  • Sand dams are structures that can be used as auxiliary water resources in case of drought as sand accumulates due to barriers crossing valley rivers and valley water is stored in the voids, increasing the water level. This structure, which is mainly used in arid regions such as Africa, has not been installed in Korea. In Korea, there are only a few cases where water is taken from debris barriers that prevent debris flow. The purpose of this study is to evaluate the effect of water supply when the sand dam is installed downstream of the existing intake barrier in Seosang-ri valley, Chuncheon. For this purpose, modeling was performed by linking the basin hydrologic model and reservoir routing model. Changes in the water level, storage and discharge in the sand dam reservoir according to the size and intake of the sand dam are presented on a case-by-case basis. As a result of application, it was found that the water supply capacity due to the sand dam installation was improved at 95% reliability. Especially, when the size is L × B × Ho = 25 m × 15 m × 1 m and the pumping rates from intake barrier and sand dam are (Q1, Q2) = (30, 20), (35, 15) ㎥/day, the efficiency was the best for water supply of 50 ㎥/day.

A Study on the Management and the Discharge of the Sluice Gates (배수갑문(排水閘門)의 관리(管理) 및 배제유량(排除流量)에 관(關)한 연구(硏究))

  • Kim, Tai Cheol;Lee, Duk Joo;Han, Young Soo
    • Korean Journal of Agricultural Science
    • /
    • v.17 no.2
    • /
    • pp.102-114
    • /
    • 1990
  • This study was carried out to analyze the operation of the sluice gates by taking Sabkyo Reservoir as the model, and to examine the formulae of the design criteria for the Agricultural Land Improvement Project by hydraulic model experiments. The results were summarized as follows ; 1. According to the records of gate operation for 9 years, the mean height of the opened gates was 4.13 m, the mean number of operated gates were 4.04, the average annual number of operation were 67 times, the average annual operating time were 192.5 hours, and the average operating time were 2.88 hours. 2. The water supplied through Sabkyo Reservoir was 88.15 megatons per year, which was about 1.4 times the effective storage capacity. And the annual volume of pumping in May, which is the most water demanding season, was 29.56 megatons in average. 3. As the submerged orifice was transformed into the surface orifice, the suggested formulae for the orifice flow on the design criteria for the Agricultural Land Improvement Project showed a discontinuous line on the transition zone. It should be improved, because it is different from the real hydraulic phenomena. 4. The formulae for the orifice flow which are divided into the submerged and surface orifices are being used. However, these formulae could be substituted for the formular, $q=C{\cdot}W\sqrt{2gH_1}$, if the discharge coefficient considering the reservoir water level, the sea water level, and the gate opening height is used.

  • PDF