• Title/Summary/Keyword: pumping rates

Search Result 113, Processing Time 0.026 seconds

Evaluation of Well Production by a Riverbank Filtration Facility with Radial Collector Well System in Jeungsan-ri, Changnyeong-gun, Korea (경남 창녕군 증산리 일대 방사집수정을 활용한 강변 여과수 개발량 평가)

  • Lee, Eun-Hee;Hyun, Yun-Jung;Lee, Kang-Kun;Kim, Hyoung-Soo;Jeong, Jae-Hoon
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.4
    • /
    • pp.1-12
    • /
    • 2010
  • Well production by a riverbank filtration facility with multi-radial collector well systems in Jeungsan-ri, Changnyeong gun, Korea was evaluated. In this study, the drawdown at collector wells due to pumping and groundwater inflow rates along the horizontal arms of the collector wells were computed through numerical simulations. Sensitivities of the well production to hydraulic conductivity and well flow coefficient, which represents the resistance to the flow from the aquifer to the horizontal arms, were analyzed. Simulation results showed that, with given proposed pumping rate conditions, the drawdown in the caisson exceeded maximum drawdown constraints in the study site and the adjustment of the pumping rate at each well is needed. The drawdown is affected by the hydraulic conductivity of the main aquifer and the well flow coefficient, which means the profound field investigation of the study site is needed to accurately estimate the efficiency of riverbank filtration through radial collector wells.

Numerical Analysis about the Flow Characteristics for Different Figures of Inlet and Outlet in Diffuser/Nozzle based on Piezoelectric Micropump (디퓨져/노즐을 이용한 압전형 마이크로 펌프의 입 . 출구 형상 차이에 따른 유동특성에 관한 수치해석적 연구)

  • Kim, Chang-Nyung;Kim, Chin-Uck
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3104-3109
    • /
    • 2007
  • The present study has been carried out to investigate the pumping characteristics for different figures of inlet and outlet in diffuser/nozzle based on piezoelectric micropump. Piezoelectric micropump system consists of several parts like a pumping chamber, diffuser/nozzle, piezoelectric element and tubes. Parts of the micropump connected with diffuser/nozzle and tubes have been analyzed.. The magnified parts have been classified into two different models based on their resistance. These models have been further classified into six models with each one having three different angles at the magnified parts. Each model has been compared and analyzed using the simulation tool, namely, CFD-ACE depending on their flow rates and characteristics.

  • PDF

Effect of Inlet and Outlet Position on the Pumping Characteristics of a Diffuser/Nozzle Based Piezoelectric Micropumps (디퓨저/노즐을 이용한 압전형 마이크로 펌프의 펌핑 특성에 미치는 입출구 위치의 영향)

  • Jang, Hun-Hee;Kim, Chang-Nyung;Jung, Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.5
    • /
    • pp.411-417
    • /
    • 2007
  • This study has been conducted to investigate pumping characteristics of diffuser/nozzle based piezoelectric micropumps. The micropumps include a piezo disk (an actuator), a chamber and a set of diffuser and nozzle. Flow in the current micropumps is controlled by a set of diffuser and nozzle, not by a nap valve. The diffuser/nozzle based micropumps are more reliable in operation and are easier in manufacturing than the flap valve based micropumps. The flow rates of the piezoelectric micropumps have been closely analyzed with a numerical calculation. It has been found that the positions of the inlet and outlet of the micropump can influence the performance of the diffuser/nozzle based piezoelectric micropumps. This study may provide fundamental understanding for the design and analysis of the piezoelectric micropumps.

Evaluation of stream depletion due to nearby groundwater pumping using Baalousha analytical solution (Baalousha 해석해를 이용한 하천 주변 지하수 양수로 인한 하천수 감소 분석)

  • Lee, Jeongwoo;Kim, Nam Won;Chung, Il-Moon;Hong, Sung Hun
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.2
    • /
    • pp.99-107
    • /
    • 2018
  • This study was to evaluate the stream depletion due to groundwater pumping from 17 wells near the Anseongcheon upper stream using the Baalousha's analytical solution (2012) which directly considers stream width and streambed hydraulic conductivity. The input hydraulic values of aquifer and streambed were obtained from the pumping tests and seepage experiments. The estimated streamflow depletion rates divided by pumping rate (dimensionless stream depletion) showed a range from 0.23 to 0.89 for 5 year pumping. In particular, the results revealed that the groundwater pumping has insignificant effects on streamflow when the stream depletion factor (SDF) is higher than 1,000 with values of dimensionless stream depletion lower than 0.4. A more simple Hunt's solution (1999) also applied to the same wells, and the results showed that the difference between the dimensionless stream depletions calculated by using both solutions could be negligible. From the comparison of the Baalousha's solution (2012) with the Hunt's solution (1999) with total 3,000 cases of simulations with combinations of various aquifer and stream properties, the stream-well distance should be more longer than stream width for reducing the discrepancy between both solutions.

Quantitative Evaluation for Improvement Effects of Performance After Mechanical Rehabilitation Treatments on Agricultural Groundwater Well (농업용 관정의 기계적 처리 이후 성능 개선 효과의 정량적 평가 사례)

  • Song, Sung-Ho;Lee, Byung-Sun;An, Jung-Gi
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.4
    • /
    • pp.42-49
    • /
    • 2016
  • Step-drawdown pumping tests for identifying the improvement of groundwater well performance after rehabilitation treatments were conducted in three longstanding wells. Three selective mechanical treatment methods including power bubble, high-voltage electric pulse, and air surging were applied to these wells and the applicability of these methods to secure additional groundwater resources were evaluated quantitatively. Commonly, drawdown at final stage of stepdrawdown pumping tests after rehabilitation decreased by as much as 0.61~0.70 meters compared to those before rehabilitation. In addition, final specific drawdown values of three wells increased from 9% to 14% after rehabilitation. Formation loss coefficient and well loss coefficient decreased to 6.1% and 60.6%, respectively, indicating some clogging materials by precipitation/corrosion/microbe within pores of aquifer materials, gravel packs, and screens were effectively removed by applied methods. Decrease of formation loss coefficient was higher in the well applied by the power bubble method meanwhile high-voltage electric pulse method demonstrated the higher decrease of well loss coefficient. Additionally secured groundwater amounts after rehabilitation ranged from 23.3 to 32.1 m3/day, which account for 8~16% of initially developed pumping rates of the wells. From the results of this study, the effective selection of rehabilitation treatments considering aquifer characteristics are expected to contribute to secure groundwater resources for irrigation as well as to plan systematic management program for groundwater resources in rural area.

A Second-Order Analysis of VM Heat Pumps (VM열펌프의 2차해석)

  • Choi, Y.S.;Jeong, E.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.208-218
    • /
    • 1996
  • Performance of a VM heat pump is considerably affected by various losses, such as enthalpy dump, reheat loss, pumping loss, conduction loss and shuttle loss. A second-order analysis model of VM heat pumps, which allows consideration of the major losses, was presented. Actual heat transfer rates for heat exchangers were calculated from the heat transfer rates obtained by the adiabatic analysis and various losses. New effective temperatures of heat exchangers were calculated from the actual heat transfer rates and the mean heat transfer coefficients until there was no appreciable change in the effective temperatures. Effects of design parameters, such as phase angle, swept volume ratio, regenerator length and speed on heating capacity, cooling capacity and COP were shown.

  • PDF

A Review of Outgassing and Methods for its Reduction

  • Grinham, Rebecca;Chew, Dr Andrew
    • Applied Science and Convergence Technology
    • /
    • v.26 no.5
    • /
    • pp.95-109
    • /
    • 2017
  • There are several contributions to the gas load of a system of which often the most important is outgassing. Adsorption occurs via two main processes, physisorption and chemisorption, and can be described using five (or six) classifying isotherms. Outgassing is the result of desorption of previously adsorbed molecules, bulk diffusion, permeation and vapourisation. Looking at the desorption rate, pumping speed and readsorption on surfaces, the net outgassing of the system can be calculated. There is significant variation in measured outgassing rates between different materials but also between published rates for the same materials, in part due to the number of different methods used to measure outgassing. This article aims to review the outgassing process, outgassing rates, measurement methods and techniques that can be used to reduce the outgassing of a system.

Evaluation of stream depletion from groundwater pumping in shallow aquifer using the Hunt's analytical solution (Hunt 해석해를 이용한 천부대수층 지하수 양수로 인한 하천수 감소 영향 분석)

  • Lee, Jeongwoo;Chung, Il Moon;Kim, Nam Won;Hong, Sung Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.11
    • /
    • pp.923-930
    • /
    • 2016
  • This study was to evaluate the stream depletion from groundwater pumping in shallow aquifer using the Hunt's analytical solution (2009) which considers a two-layer leaky aquifer-stream system. From the total 2,187 cases of simulations with combinations of various aquifer and stream properties, the streamflow depletion rates divided by the groundwater pumping rate showed the low values when the stream depletion factor (SDF) is higher than 1,000-10,000, and was more sensitive to the aquitard hydraulic conductivity than the streambed hydraulic conductivity. The comparison of the Hunt's solution (2009) with the Hunt's solution (1999) of a single layer aquifer indicated that the maximum difference between the dimensionless stream depletions calculated by using both solutions is above 0.3, and the stream depletion is significantly affected by the hydraulic properties of the $2^{nd}$ layer as the SDF of the first layer increases. The Hunt's solution (2009) was applied to the real shallow groundwater well that is located in Chunju-Si, and the results revealed that the groundwater pumping has significant effects on streamflow in a short period of time, showing that the dimensionless stream depletion exceeds 0.8 within a few days. It was also found that the shallow groundwater pumping effects on stream depletion are highly dependent on the stream-well distance for the locations with high hydraulic diffusivity of $1^{st}$ layer and low vertical leakance between $1^{st}$ and $2^{nd}$ layers.

Optimal Groundwater Management Model for Coastal Regions Using Parallel Genetic Algorithm

  • Park, Nam Sik;Hong, Sung Hun;Shim, Myung Geun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.77-89
    • /
    • 2004
  • A computer model is developed to assess optimal ground water pumping rates and optimal locations of wells in a coastal region. A sharp interface model is used to simulate the freshwater and salt water flows. Drawdown, upconing, saltwater intrusion and the contamination of well are considered in this model. A genetic algorithm with parallel processing is used to identify the optimal solution.

  • PDF

Heat transfer and friction loss characteristics of shaped short pin-fin arrays (짧은 못형핀의 형상 변화에 따른 열전달 및 마찰손실 특성)

  • Cho, H.H.;Goldstein, R.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.259-267
    • /
    • 1997
  • Average heat transfer coefficients and friction coefficients have been measured from staggered short pin-fin arrays to investigate the effect of fin shapes. Flow entering into the test section is a fully developed duct flow and the Reynolds number ranges from 5,000 to 25,000 based on fin diameter and average approaching velocity. The fin has three different shapes; uniform-diameter circular fin, two stepped-diameter circular fins. Average heat transfer rates change slightly with the fin shapes. However, friction loss(pressure loss) for the stepped-diameter fins is significantly less than that for the uniform-diameter fin. This results indicate that the stepped-diameter fin arrays in duct flow enhance heat transfer rates largely based on unit pumping power.

  • PDF