• 제목/요약/키워드: pump washing

검색결과 16건 처리시간 0.028초

열펌프를 이용한 슬러리 돈분뇨 증발건조처리시스템 개발 (Development of Heat Pump Use Slurry Pig Manure Evaporation Drying System)

  • 김현태;최홍림
    • Journal of Biosystems Engineering
    • /
    • 제30권1호
    • /
    • pp.32-37
    • /
    • 2005
  • This study was conducted the slurry pig manure treatment by condensation drying of liquid from the slurry manure with a heat-pump and electric heater combined with air flow channel system. The system was designed as liquid and solid matters separation of slurry manure, and it can doing continuous input of slurry manure from a pig house, and it can operated year round use for pig farms. The separation of liquid and solid matters from slurry manure needed the prevention of solid accumulation in the system. The system was designed as closed space from outside air space for maximized evaporation of liquid and the condensation of liquid from slurry manure. The system can be operated the pig slurry manure treatment regardless of seasons in a yew. The separated evaporation water from the pig slurry manure by the heat-pump was satisfactorily pure water that can be used as washing water in livestock farms. The system can applicate to about 100 heads of pig, and the proper area of evaporation plate system was considered around $10\;m^2$. The input electrical energy of about 15 kWh which the cost equal to 250,000 won per month.

초미세기포를 이용한 해양쓰레기 표면 내 염분제거에 관한 연구 (A Study of the Salt Rejection from the Surface of Marine Waste using Ultra Fine Bubble)

  • 김보민;김광구;박찬규
    • 한국산학기술학회논문지
    • /
    • 제22권6호
    • /
    • pp.11-18
    • /
    • 2021
  • 나노버블수는 태양광 패널 청소, 도로의 염분 제거, 기계의 정밀 부품 청소 등 다양한 세척 공정에 사용된다. 해양쓰레기 세척 시스템의 전처리에 나노버블을 적용하면 높은 세척 효율과 물 절약이 가능하다. 본 연구에서는 나노버블수의 염분 제거율을 비교하기 위해 NaCl 200,000 mg/L 용액에 목재를 침적시켜 해양쓰레기를 제작하였다. 수돗물과 나노버블수를 이용하여 노즐 종류, 오리피스 직경, 펌프 회전수 및 세척 시간에 따른 목재 표면 염분농도를 비교하였다. 목재 표면 염분농도는 세척시간이 길어질수록 감소하였다. 하지만 물 사용량을 고려한 최적의 세척 시간은 5-10초 사이였다. 노즐의 오리피스 직경이 커질수록 분사압력은 낮아지며, 세척 후 목재 표면 염분농도는 높아졌다. 이는 노즐의 오리피스 직경이 세척 시스템에서 중요한 요인임을 나타낸다. 나노버블수를 이용한 세척 후 목재 표면 염분농도는 수돗물로 세척 후 목재 표면 염분농도에 비해 부채꼴형 노즐은 2.2 %, 원형 노즐은 30.9 % 낮았다. 또한, 나노버블수를 이용한 세척 실험에서 부채꼴형 노즐을 사용하여 세척하였을 때가 원형 노즐을 사용하였을 때보다 목재 표면 염분농도가 약 9.5 mg/L 낮았다.

지하수 관측정의 시설개선에 따른 수질변화와 유지관리에 대한 연구 (The Importance of Monitoring Wells Maintenance in Improving Groundwater Quality)

  • 김정우;서용교;김락현;천정용
    • 지질공학
    • /
    • 제24권2호
    • /
    • pp.283-295
    • /
    • 2014
  • 중장기적으로 운영하는 지하수 관측정은 설치도 중요하지만 그 성능 유지를 위한 관측정 시설 관리 또한 중요하다. 따라서 본 조사는 관측정 내부에 이물질이 많이 형성되고 오래된 관측정 시설을 대상으로 실시하였다. 조사대상 관측정들은 장비(펌프) 세척, 시료채취 튜브 교체, 관측정 청소로 구분하여 시설을 개선하였다. 주 양/음이온과 중금속 농도의 변화를 검토한 결과, 마그네슘, 망간, 아연 항목이 증가하는 경향으로 나타났다. 이것은 관측정 내부에 흡착요인으로 작용하던 이물질(탄산칼슘이나 점토물질)이 시설개선 과정을 통해 제거되었기 때문이다. 따라서, 중장기적으로 운영이 계획된 관측정은 1년마다 시설 및 내부 점검을 실시하고 이상현상 발생시 조치를 취하되, 최소 약 4 ~ 5년마다 수행하는 것이 추천된다.

양방향 펌프의 유동 해석을 통한 펌프 케이싱의 최적설계 (Design Optimization of Two-Way Pump Casing through Flow Analysis)

  • 김동휘;노유정;임오강;최은호;최주용
    • 한국전산구조공학회논문집
    • /
    • 제31권2호
    • /
    • pp.79-85
    • /
    • 2018
  • 기존의 한방향 펌프는 순환과 배수를 위해 각각의 모터를 사용하지만, 양방향 펌프는 하나의 모터로 모터의 회전 방향에 따라 배수와 순환이 모두 가능하므로 원가절감이 가능하다. 하지만 양방향 펌프는 배수와 순환 시 펌프 케이싱 내부에서 역류와 흡입이 발생하여 유입된 물이 각각 배출구와 순환구로 원활하게 유출되지 못하는 단점이 있다. 본 연구에서는 주효과 분석을 통해 배출과 순환 시 유출되는 유량과 토크에 주요한 영향을 미치는 인자를 설계변수로 선택하여 실험계획법, 근사모델, 그리고 최적설계를 통해 펌프 케이싱 형상을 최적화함으로써 역류와 흡입은 개선하고 펌프의 토크 대비 배출구와 순환구의 유량을 증가시키는 효과를 거두었다.

소음원의 영향이 고려된 가상 세탁음 제작을 통한 드럼 세탁기의 음질 인덱스 구축 (Sound Quality Evaluation for Laundry Noise by a Virtual Laundry Noise Considering the Effect of Various Noise Sources in a Drum Washing Machine)

  • 정재은;양인형;누룰 파와지;정운창;이정윤;오재응
    • 한국소음진동공학회논문집
    • /
    • 제22권6호
    • /
    • pp.564-573
    • /
    • 2012
  • The objective of this study is to determine the effect for the sound quality according to the noise source and to build the sound quality index of the laundry noise. In order to compare laundry noise among the influence of noise sources, we made virtual laundry noises by synthesizing an actual laundry noise and each noise source such as a dropping noise, water noise, motor noise and circulation pump noise. We conducted a listening test by customers using virtual laundry noises. As a result of listening test, we found that the dropping noise has a decisive effect on the sound quality of the laundry noise. We conducted the multi regression analysis of sound quality for the laundry noise using the statistical data processing. It is verified to the reliability of the multi regression index by comparison with listening results and index results of other actual laundry noises. This study is expected to provide a guide line for improvement of the laundry noise.

토양의 염기치환 용량 측정에 관한 연구 (측정장치에 대하여) (Determination of Cation Exchange Capacity in Soils (study on the apparatus))

  • 최대웅;이종목
    • 한국토양비료학회지
    • /
    • 제6권2호
    • /
    • pp.83-88
    • /
    • 1973
  • 염기치환용량 측정을 위하여 염기의 포화 과잉염기의 세척을 위한 작업단계에서 현재 사용되어 오던 원심분리기, 흡인여과장치 보다 새로이 고안된 Column set를 이용 하였을때 다음과 같은 양호한 결과를 얻었다. 1. CEC 측정치는 흡인여과시의 치와 99.91%인 고도의 상관이 있었으며 반복성의 변이가 흡인여과 1.94%에 비해 1/3이나 적은 0.66%로 정확도도 더욱 높았다. 2. Column set 이용시 흡인여과에 비하여 작업시간 및 노력이 1/3정도 절약되고 한거번에 다량의 시료를 처리할 수 있다. 3. 고가의 기계(Vacuum pump, Shaker, Section, Apparatus, Centrifuge) 등이 구비되지 않아도 CEC를 측정할 수 있었다.

  • PDF

유류오염토양 처리를 위한 마이크로나노버블 토양세척에 관한 연구 (A Study on the Treatment of Oil Contaminated Soils with Micro-nano Bubbles Soil Washing System)

  • 최호은;정진희;한영립;김대용;정병길;최영익
    • 한국환경과학회지
    • /
    • 제20권10호
    • /
    • pp.1329-1336
    • /
    • 2011
  • The objectives of this study are to examine the processing of oils contamination soil by means of using a micronano-bubble soil washing system, to investigate the various factors such as washing periods, the amount of micro-nano bubbles generated depending on the quantity of acid injection and quantity of air injection, to examine the features involved in the elimination of total petroleum hydrocarbons (TPHs) contained in the soil, and thus to evaluate the possibility of practical application on the field for the economic feasibility. The oils contaminated soil used in this study was collected from the 0~15 cm surface layer of an automobile junkyard located in U City. The collected soil was air-dried for 24 hours, and then the large particles and other substances contained in the soil were eliminated and filtered through sieve No.10 (2 mm) to secure consistency in the samples. The TPH concentration of the contaminated soil was found to be 4,914~5,998 mg/kg. The micronano-bubble soil washing system consists of the reactor, the flow equalization tank, the micronano- bubble generator, the pump and the strainer, and was manufactured with stainless material for withstanding acidic phase. When the injected air flow rate was fixed at 2 L/min, for each hydrogen peroxide concentrations (5, 10, 15%) the removal percents for TPH within the contaminated soil with retention times of 30 minutes were respectively identified as 4,931 mg/kg (18.9%), 4,678 mg/kg (18.9%) and, 4,513 mg/kg (17.7%). And when the injected air flow rate was fixed at 2 L/min, for each hydrogen peroxide concentrations (5, 10, 15%) the removal percents for TPH within the contaminated soil with retention times of 120 minutes were respectively identified as4,256 mg/kg (22.3%), 4,621 mg/kg (19.7%) and 4,268 mg/kg (25.9%).

초미세기포 water jet을 이용한 도로 시설물 분진 제거 효율 평가 (Evaluation of Dust Removal Efficiency on Roadway Structures Using Ultrafine Bubble Water Jet)

  • 김현진;박일건
    • 청정기술
    • /
    • 제27권1호
    • /
    • pp.39-46
    • /
    • 2021
  • 4 HP, 80 LPM 급 초미세기포수 발생장치를 탑재한 도로 구조물 세척차량을 이용하여 도시 내 아파트 단지 주변 차량 통행이 많은 터널 내 콘크리트 표면과 타일 벽면을 세척하였다. 초미세기포 생성은 대기 중 공기를 2 ~ 3 LPM 으로 기액혼합 자흡펌프로 가압된 공기를 임펠러 회전력을 이용하여 마이크로 크기의 미세기포(fine-bubble)를 생성한다. 생성된 기포를 다단충돌판과 회전 노즐을 통과하면서 평균 직경 크기는 164.5 nm, 6.81 × 107 particles mL-1의 초미세기포(ultrafine bubble)를 생산하였다. 생산된 초미세기포를 함유한 세척수는 압력 150 bar, 토출량 30 LPM 으로 도로 구조물 표면에 흡착된 분진을 고압세척 분사하여 제거하였다. 분석실험은 세척 전과 후로 구분하여 표면에 흡착한 분진을 ISO 8502-3의 표면 오염 측정방법을 적용하였으며, 테이프 흡착으로 분진 입자를 채취하였다. 수집된 테이프는 중량법과 소프트웨어 ImageJ를 적용하여 분진의 무게와 입자 개수에 대한 제거율을 산정하였다. 실험 결과, 타일 벽면 표면에 흡착된 분진 입자 개수는 세척 전과 후로 각각 3,063 ± 218 particles mL-1, 20 ± 5 particles mL-1, 중량은 580 ± 82 mg, 13 ± 4 mg 으로 나타났다. 콘크리트 구조물 표면에서의 입자개수는 세척 전과 후로 각각 8,105 ± 1,738 particles mL-1, 39 ± 6 particles mL-1이었으며, 중량은 1,448 ± 190 mg, 118 ± 32 mg으로 나타났다.

공동현상 가시화 실험을 통한 절환밸브 바텀플러그 형상 최적화 (Cavitation Visualization Test for Shape Optimization of Bottom Plug in Reversing Valve)

  • 김태안;이명곤;한승호
    • 대한기계학회논문집A
    • /
    • 제40권11호
    • /
    • pp.913-918
    • /
    • 2016
  • 자동차 엔진과 변속기 블록 등의 가공과정에서 잔류하는 기름때를 제거하기 위한 부품 세척장비는 정교한 제어장치 없이도 정확한 수류방향 절환이 원활히 이루지는 3 방향 절환밸브를 사용한다. 그러나, 밸브의 복잡한 유로 및 바텀플러그 형상으로 인해 유속변화가 심하게 발생하여 공동현상이 나타날 수 있다. 본 연구에서는 3 방향 절환밸브 내의 유동특성을 해석적으로 평가하였으며, 바텀플러그 하부에서 나타나는 공동현상을 공동화지표와 POC(Percent of cavitation)를 도입하여 정량화하였다. 공동현상의 저감을 위해 바텀플러그 형상을 매개변수화하고, 해석의 수렴성 개선과 해석시간을 단축시킬 수 있는 단순 유한요소모델을 이용하여 유동해석을 통한 형상최적설계를 실시하였다. 또한, 연구팀에서 보유하고 있는 유동시험설비와 ISA-RP75.23 규격에 맞게 제작된 시편을 이용하여 공동현상 가시화 실험을 실시하여 해석결과를 검증하였다.

시설용수 및 영농편의용수 공급시스템 개발 (I) - FDA 시스템 개발 - (Development of Clean Water Supplying System for Greenhouse Cultivation and Convenience Water (I) - Development of the FDA System -)

  • 이광야;최경숙
    • 한국농공학회논문집
    • /
    • 제51권5호
    • /
    • pp.95-100
    • /
    • 2009
  • The water purification systems have been hardly used for agricultural purpose due to their complicated compositions and high costs for farmers, while only simple filtrations have been applied to irrigation systems in order to prevent the system from clogging problems. This study therefore developed a clean water supplying system, the Filter-Disinfection-Adsorption (FDA) system, especially for greenhouse cultivation of where low quality of water is available. This system has also been produced for providing convenience water to farmers in the areas of no water supply service systems for the purpose of washing their bodies or agricultural machineries after farm work. The FDA system consists of three stages of purification processes with an integral module, including disk and teflon filtrations and Ultraviolet (UV) sterilization processes. Indoor experiments were undertaken with a trial product of the FDA system to test its performance. The operation test of the process was performed as well as the condition check of each item including UV module, filters, control panel, pump, valves, etc. The results shows good performance of each test with no critical problems. The initial and maintenance costs were also analysed with other purification systems. From the comparisons, the FDA system found to be very economical and easy to use.