• 제목/요약/키워드: pump type

검색결과 1,069건 처리시간 0.031초

cAMP induction by ouabain promotes endothelin-1 secretion via MAPK/ERK signaling in beating rabbit atria

  • Peng, Li-qun;Li, Ping;Zhang, Qiu-li;Hong, Lan;Liu, Li-ping;Cui, Xun;Cui, Bai-ri
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제20권1호
    • /
    • pp.9-14
    • /
    • 2016
  • Adenosine 3',5'-cyclic monophosphate (cAMP) participates in the regulation of numerous cellular functions, including the $Na^+-K^+$-ATPase (sodium pump). Ouabain, used in the treatment of several heart diseases, is known to increase cAMP levels but its effects on the atrium are not understood. The aim of the present study was to examine the effect of ouabain on the regulation of atrial cAMP production and its roles in atrial endothelin-1 (ET-1) secretion in isolated perfused beating rabbit atria. Our results showed that ouabain ($3.0{\mu}mol/L$) significantly increased atrial dynamics and cAMP levels during recovery period. The ouabain-increased atrial dynamics was blocked by KB-R7943 ($3.0{\mu}mol/L$), an inhibitor for reverse mode of $Na^+-Ca^{2+}$ exchangers (NCX), but did not by L-type $Ca^{2+}$ channel blocker nifedipine ($1.0{\mu}mol/L$) or protein kinase A (PKA) selective inhibitor H-89 ($3.0{\mu}mol/L$). Ouabain also enhanced atrial intracellular cAMP production in response to forskolin and theophyline ($100.0{\mu}mol/L$), an inhibitor of phosphodiesterase, potentiated the ouabain-induced increase in cAMP. Ouabain and 8-Bromo-cAMP ($0.5{\mu}mol/L$) markedly increased atrial ET-1 secretion, which was blocked by H-89 and by PD98059 ($30{\mu}mol/L$), an inhibitor of extracellular-signal-regulated kinase (ERK) without changing ouabain-induced atrial dynamics. Our results demonstrated that ouabain increases atrial cAMP levels and promotes atrial ET-1 secretion via the mitogen-activated protein kinase (MAPK)/ERK signaling pathway. These findings may explain the development of cardiac hypertrophy in response to digitalis-like compounds.

산화알루미늄 섬유와 니켈분말 후처리공정에서 입자의 노출특성 (Exposure Characteristics of Particles during the After-treatment Processes of Aluminum Oxide Fibers and Nickel Powders)

  • 김종범;김경환;류성희;윤성택;배귀남
    • 한국산업보건학회지
    • /
    • 제26권2호
    • /
    • pp.225-236
    • /
    • 2016
  • Objectives: Nanomaterials have been used in various fields. As use of nanoproducts is increasing, workers dealing with nanomaterials are also gradually increasing. Exposure assessments for nanomaterials have been carried out for protection of worker's health in workplace. Exposure studies were mainly focused on manufacturing processes, but these studies on after-treatment processes such as refinement, weighing, and packing were insufficient. So, we investigated exposure characteristics of particles during after-treatment processes of $Al_2O_3$ fibers and Ni powders. Methods: Mass-production of Ni powder process was carried out in enclosed capture-type canopy hood. In a developing stage, $Al_2O_3$ was handled with a local ventilation unit. Exposure characteristics of particles were investigated for $Al_2O_3$ fiber and Ni powder processes during the periods of 10:00 to 16:00, 20 May 2014 and 13:00 to 16:00, 21 May 2014, respectively. Three real-time aerosol instruments were utilized in exposure assessment. A scanning mobility particle sizer(SMPS, nanoscan, model 3910, TSI) and an optical particle counter(OPC, portable aerosol spectrometer, model 1.109, Grimm) were used to determine the particle size distribution in the size range of 10-420 nm and $0.25-32{\mu}m$, respectively. In addition, a nanoparticle aerosol monitor(NAM, model 9000, TSI) was used to measure lung-deposited nanoparticle surface area. Membrane filters(isopore membrane filter, pore size of 100 nm) were also used for air sampling for the FE-SEM(model S-5000H, Hitachi) analysis using a personal sampling pump(model GilAir Plus by 2.5 L/min, Gilian). Conclusions: For Ni powder after-treatment process, only 27% increase in particle concentration was found during the process. However, for $Al_2O_3$ fiber after-treatment process, significant exposure(1.56-3.34 times) was observed during the process.

다양한 암세포주에서 Jaspine B의 함암활성 비교 (Differential Cytotoxic Effects of Jaspine B in Various Cancer Cells)

  • 이지훈;최광익;권미화;이동주;최민구;송임숙
    • 생명과학회지
    • /
    • 제26권12호
    • /
    • pp.1392-1399
    • /
    • 2016
  • Jaspine B는 석회해면류에서 추출된 sphingosine유도체로 인간 암세포에서의 항암활성이 보고되었다. 그러므로 본 연구는 다양한 인간 암세포주에서 항암활성을 비교하고, 암세포주에서의 Jaspine B의 농도를 측정하여 항암 활성과의 연관성을 확인하고자 하였다. 항암활성은 MTT 방법을 이용하여 측정하였고, $EC_{50}$ 값으로 표현하였다. 암세포주내 Jaspine B의 농도는 LC-MS/MS를 이용하여 분석하였다. 항암활성은 세포주마다 다양하게 나타났는데, 유방암과 흑색종 세포주에서 항암활성이 높게 나타났으며($EC_{50}$ 각각 $2.3{\mu}M$$2.6{\mu}M$), 신장암세포주에서는 $EC_{50}$ 값이 $29.4{\mu}M$이었다. 암세포주에서의 $EC_{50}$ 값은 동일한 세포에서의 Jaspine B 농도와 높은 상관성을 나타내었으며(r=0.838), 암세포내 약물농도를 조절하는 것으로 잘 알려진 P-glycoprotein과 breast cancer resistance protein 등의 배출수송계와는 관련이 없음을 확인하였다. 이상의 결과는 세포내 약물농도를 높게 유지하는 것이 항암활성에 매우 중요하며, 세포내 약물농도가 암세포주에 따라 다른 약효를 보이는 원인으로 사료된다.

Ta2O5/SiO2를 이용한 고출력 광섬유 레이저의 펌프 LD 보호기용 반사형 필터 설계 및 제작 (Design and Fabrication of Reflection-type Pump LD Protection Filters for High Power Fiber Lasers by Using Ta2O5/SiO2 Thin Films)

  • 성하민;김재헌;이석;전영민
    • 한국광학회지
    • /
    • 제23권3호
    • /
    • pp.124-127
    • /
    • 2012
  • 본 논문에서는 고출력 광섬유 레이저에서 역입사되는 레이저 광으로부터 펌프 LD를 보호하기 위한 반사형 2색 필터를 설계하고 제작하였다. 펌프 LD 발진 파장인 905 nm~925 nm 대역에서 투과율은 0.1%이하, 광섬유 레이저 출력 반사광이나 브릴루앙 산란광 파장대역인 1020 nm~1100 nm 대역에서 투과율은 99.9% 이상이 되도록 필터를 설계하였다. 기판(Substrate)은 $SiO_2$로 사용하고 접착력이 우수한 Oxide 계열 물질인 $SiO_2/Ta_2O_5$를 박막 재료로 사용하였다. 최적화된 설계를 한 후 필터를 제작하였고, 그 특성을 비교하였다. 제작된 필터의 투과율이 905 nm ~ 925 nm 대역에선 0.1%이하, 1020 nm~1100 nm 대역에선 95.5%이상으로 측정되어 공정오차를 고려한 설계범위 안에 들어옴을 확인하였다. 제작된 필터는 레이저 출력 1W이상의 입력광에 대해서도 정상 동작함을 확인하였다.

치과적 장애환자의 치과치료를 위해 시행한 깊은 진정 : 전신마취와 비교한 통계적 고찰 (CLINICO-STATISTICAL ANALYSIS OF DEEP SEDATION COMPARED WITH GENERAL ANESTHESIA AT THE CLINIC FOR THE DISABLED)

  • 서광석;신터전;김현정;한희정;한진희;김혜정;장주혜;신혜영
    • 대한장애인치과학회지
    • /
    • 제5권1호
    • /
    • pp.12-17
    • /
    • 2009
  • Background : To do dental treatments successfully for dentally disabled patients who are unable to cooperate to procedures needs deep sedation (DS) or general anesthesia (GA). But there are some difficulties in selecting DS because of some disadvantages such as airway problem etc. But, if we select appropriate cases, DS would be better than GA. Methods : We reviewed total 238 cases of patients who had received dental treatments under GA or DS at the clinic for the disabled in Seoul National University Dental Hospital from November 2007 to February 2009. To compare anesthesia condition between DS and GA, we reviewed preanesthesia evaluation sheet, anesthesia or sedation records and PACU sheets retrospectively. Results : The number of DS cases was 25 (11%) and that of GA was 218 (89%). To maintain DS, intravenous propofol was infused with syringe pump (100%), and sevoflurane (134 cases) or propofol (13 cases) were used for sedation induction. Mean total treatment time for DS was 36 min and 2 hour 25 min for GA. The recovery time at PACU was 44 min for DS and 80 min for GA. There were no severe complications in DS, but 18 cases showed nausea and vomiting in GA. Conclusion : Deep sedation for disabled dental patients should be selected for effective behavioral control in conjunction with general anesthesia, considering duration and pain-evoking potentials of dental treatment and type and severity of patients' disabilities altogether.

  • PDF

CFD 해석을 이용한 현장 열응답 시험의 출구온도 예측 (The Outlet Temperature Prediction of In-Situ Thermal Response Test using CFD Analysis)

  • 심용섭;이희상
    • 한국산학기술학회논문지
    • /
    • 제17권1호
    • /
    • pp.28-35
    • /
    • 2016
  • 지열원 히트펌프 시스템에서 지중 열교환기 설계를 위해 수행하는 현장 열응답 시험은 많은 시간과 비용이 수반되기 때문에 조건 변화에 따른 출구온도 예측이 어려운 실정이다. 본 연구에서는 국내에서 주로 사용하는 수직형 지중 열교환기의 열전달 성능을 예측하기 위한 방안으로 3차원 CFD 해석 기법을 제안하고, 2개소의 현장 열응답 시험의 출구온도와 기울기 값을 비교하여 CFD 해석 방법의 신뢰성을 확인하였다. CFD 해석 결과, 2개소의 현장 열응답 시험의 출구온도는 $0.5^{\circ}C$ 이내에서 예측하였고, 기울기 값은 1.6% 이내에서 적절히 예측하였다. 이를 통해 CFD 해석 방법의 신뢰성을 확인하고, 2개소의 현장 열응답 시험의 유량 및 지중 유효 열전도도 조건을 각각 ${\pm}20%$ 변화시키면서 현장 열응답 시험의 출구온도를 예측하였다. 첫 번째 현장(Case 1)의 경우 유량 변화에 따라 $28.0^{\circ}C$(-20%)와 $29.6^{\circ}C$(+20%), 지중 유효 열전도도 변화에 따라 $29.6^{\circ}C$(-20%)와 $28.0^{\circ}C$(+20%)로 현장 열응답 시험의 출구온도를 예측하였으며, 두 번째 현장(Case 2)의 경우 유량 변화에 따라 $28.4^{\circ}C$(-20%)와 $29.8^{\circ}C$(+20%), 지중 유효 열전도도 변화에 따라 $29.7^{\circ}C$(-20%)와 $28.4^{\circ}C$(+20%)로 현장 열응답 시험의 출구온도를 각각 예측하였다.

차집관로의 조사 및 분석을 통한 하수관로정비 사업의 효과 감소 원인 분석 (Cause Analysis for Reduced Effect of Sewer Pipe Improvement Project Based On Investigation of Interceptor Sewers)

  • 채명병;배영혜;김형수
    • 한국습지학회지
    • /
    • 제20권3호
    • /
    • pp.219-226
    • /
    • 2018
  • 차집관로는 국유지가 많은 하천변에 매설되어 있어 파손이나 침입수/유입수(불명수, I/I) 의 유입으로 공공하수처리시설의 운영효율이 떨어지며, 하수관로 정비사업의 효율도 저하되는 것으로 나타났다. 본 연구는 하수관로 정비사업 효과의 감소원인에 가장 많은 영향을 미치는 차집관로를 대상으로 감소원인에 대한 분석을 하였다. 즉, 대상지역 3개소를 선정하여 차집관로의 현황조사(관로연장, 관경, 관종, 매설년도, 매설위치 등), 차집관로에 대한 차수(Pump 작업) 및 준설작업을 병행한 관로내부(CCTV)조사, 맨홀내부(육안)조사, 유량 및 수질조사 결과를 이용한 오염부하량 산정 등을 수행하였다. 합류지역은 동시 다측점 유량조사와 차집관로 유량 및 수질(BOD)조사, 오염부하량 비교 등을 수행하였으며, 차집관로 부실화에 따른 침입수/유입수 발생 현황 등 실태조사를 실시하였다. 연구결과, 하수관로정비 사업의 효과를 감소시키는 주요 원인은 차집관로의 노후화 및 미정비로 인해 공공 하수처리시설로 저농도 하수 및 불명수 유입되기 때문인 것으로 분석되었다.

OBIGGS용 기체 분리막에서 오존이 미치는 영향 (Effect of Ozone on Gas Separation Membranes for On-Board Inert Gas Generation System (OBIGGS))

  • 정경남;우승문;김세종;김지현;한상훈;남상용
    • 멤브레인
    • /
    • 제28권6호
    • /
    • pp.406-413
    • /
    • 2018
  • OBIGGS에서는 대기 중의 미량의 오존이 고분자 분리막의 손상을 가져오기 때문에 전단에 오존 제거장치를 설치하여 분리막에 전해지는 기체에서 오존의 농도를 감소시켜 분리막의 손상을 막고 있다. 본 연구에서는 OBIGGS용 기체 분리막을 이용하여 오존 노출시간에 따른 인장강도와 기체투과특성을 평가하여 오존 노출환경과 투과특성의 관계를 확인하였다. 폴리이미드계와 폴리설폰계 두 종류의 중공사 분리막을 이용하였고, $6.37cm^2$의 유효 막 면적을 가지는 중공사 모듈을 제조하여 사용하였다. 오존 챔버를 이용하여 오존의 농도를 2-3 ppm으로 유지하였으며, 챔버 내의 기체를 펌프를 이용하여 모듈내로 지속적으로 공급하였으며, 오존 노출시간에 따라서 기체투과특성과 인장강도를 각각 평가하였다. 그 결과 폴리이미드계 중공사 분리막은 투과도에서 20%의 감소만 나타났을 뿐, 선택도와 인장강도에서 다른 큰 변화를 나타내지 않고 균일하게 유지되는 것을 확인하였다. 하지만 폴리설폰계 중공사 분리막을 사용하였을 때는 투과도가 80% 이상 감소하였고, 인장강도는 70% 이상 감소하는 결과를 나타내었다.

자율운항선박의 원격검사를 위한 영상처리 기반의 아날로그 게이지 지시바늘 객체의 식별 (Identifying Analog Gauge Needle Objects Based on Image Processing for a Remote Survey of Maritime Autonomous Surface Ships)

  • 이현우;임정빈
    • 한국항해항만학회지
    • /
    • 제47권6호
    • /
    • pp.410-418
    • /
    • 2023
  • 최근 자율운항선박 관련 연구개발과 상용화가 급속하게 진행됨과 동시에 자율운항선박의 감항성 확보를 위하여 선박에 설치된 각종 장비 상태를 원격지에서 검사할 수 있는 방법 역시 연구되고 있다. 특히, 각종 장비에 부착된 아날로그 게이지의 값을 영상처리를 통해 획득할 수 있는 방법이 주요 이슈로 부각되고 있는데, 그 이유는 영상처리 기법을 이용하면 이미 설치되었거나 또는 설치 예정인 다수의 장비를 변형 또는 변경하지 않고 비접촉식으로 게이지의 값을 검출할 수 있어서 장비의 변형 또는 변경에 따른 선급의 형식승인 등이 필요하지 않은 장점이 있기 때문이다. 본 연구의 목적은 잡음이 포함된 아날로그 게이지의 영상 중에서 동적으로 변하는 지시바늘의 객체를 식별하는데 있다. 지시바늘 객체의 위치는 정확한 게이지 값의 판독에 영향을 미치는데, 게이지 값을 정확하게 판독하기 위해서는 우선하여 지시바늘 객체의 식별이 중요하다. 지시바늘 객체의 식별 작업을 위한 영상은 비상소화펌프 모형에 부착한 수압 측정용 아날로그 게이지를 이용하여 획득하였다. 획득한 영상은 가우시안 필터와 임계처리 그리고 모폴로지 연산 등을 통해서 사전처리한 후, 허프 변환을 통해서 지시바늘의 객체를 식별하였다. 실험결과, 잡음이 포함된 아날로그 게이지의 영상에서 지시바늘의 중심과 객체가 식별됨을 확인하였고, 그 결과 본 연구에 적용한 영상처리 방법이 선박에 장착된 아날로그 게이지의 객체 식별에 적용될 수 있음을 알았다. 본 연구는 자율운항선박의 원격검사를 위한 하나의 영상처리 방법으로 적용될 것으로 기대된다.

USCG phase-II 선박평형수 처리장치 성능 평가에 대비한 해양식물플랑크톤 네트 농축효율 비교 (Efficiency of concentrating marine microplanktonic organisms using net sampler to verify the efficacy of a ship's ballast water treatment system)

  • 백승호;이민지;신경순
    • 한국산학기술학회논문지
    • /
    • 제17권3호
    • /
    • pp.136-143
    • /
    • 2016
  • 본 연구에서는 USCG Phase-II 형식승인을 대비하여 ${\geq}10{\mu}m$${\leq}5{\mu}m$ 크기 식물플랑크톤의 생물군에 관해서 네트를 이용한 생물농축 방법 및 농축효율을 비교하고자 하였다. 생물 농축 효율의 비교는 네트 망목 사이즈($5{\mu}m$, $7{\mu}m$)의 차이, 펌프 이용를 이용한 연속적인 시료 공급 방법과 핸드비이커 이용한 불연속적인 시료공급의 차이, 자연해수의 용량에 따른 차이 등을 종합적으로 검토하였다. 각 실험군 간의 차이를 t-test로 검증한 결과, $5{\mu}m$$7{\mu}m$망목에 의한 차이는 유의하게 나타나지 않았고(p>0.05), 자연해수 용량에 따른 생물농축효율의 차이도 명확하지 않았다(p>0.05). 하지만 펌프에 의한 연속적인 시료 공급은 핸드비이커의 불연속적인 시료보다 통계적으로 유의하게 생물 농축효율이 높게 나타났다(t-test: t:-4.058, p<0.05). 특히 네트 농축 실험 시 출현한 식물플랑크톤의 군집조성은 규조류 17종, 와편모조류 15종, 유글레나조류 1종, 착편모조류 2종과 함께 미동정 편모조류로 총 36종이였고, 우점종으로는 Pseudo-nitzschia spp.로 관찰되었다. 여기서, 모든 실험군에서 생물 농축 효율이 20-25% 전후로 균일하게 낮게 나타난 것이 특이적 이였고, 그 이유로는 우점종인 Pseudo-nitzschia spp.의 한 편의 사이즈가 $3-8{\mu}m$로 네트 망목을 통과하여 손실된 결과로 판단되었다. 결과적으로 네트의 농축은 자연 식물플랑크톤 군집에서 출현한 종의 사이즈에 의존한다는 것을 확인할 수 있었고, 이는 USCG Phase-II 의 형식 승인 선박평형수 처리 장치(BWTS: Ballast Water Treatment System) 통과 후 생물농축과정에서 종 특이적인 사이즈의 분포 양상을 충분하게 검토하여 농축 용량을 조절할 필요가 있을 것으로 생각된다.