• 제목/요약/키워드: pump pressure

검색결과 1,494건 처리시간 0.023초

냉동.냉장창고용 냉수펌프의 에너지절감 기법 (Energy saving technique of Refrigeration warehouse Cold Water Pump)

  • 정춘병;전기영;이상집;김대균;이훈구;한경희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.409-414
    • /
    • 2005
  • We are interaction refrigeration warehouse cold water pump system and photovoltaic generation system. At this time, a target pressure is able to control in spite of change of the pressure according to pump head and rate of flow of pump. Also, we carry out the vector control of BLDC moor with the maximum torque operation and a high reliability from territory of each operation speed. Therefore, in this paper, we conclude energy saving technique of refrigeration warehouse cold water pump system.

  • PDF

자동차 PS용 베인펌프의 캠곡선 설계 (Design for Cam Curve of a Oil Hydraulic Vane Pump for Vehicles′ Power Steering System)

  • 정석훈;정재연
    • Tribology and Lubricants
    • /
    • 제20권3호
    • /
    • pp.157-162
    • /
    • 2004
  • The cam curve of a balance type vane pump consists usually of circular arcs and Archimedes' spirals. However, if they are connected directly together, the curve must have a few discontinuous points of the gradients and the motion of the vanes is no longer smooth. Designing data for an oil hydraulic vane pump used in power steering system were obtained by the acquisition of optimum cam profile data which can be available to reduce noises and vibrations through the minimization of cavitation with the improvement of suctional performance. The performance test is carried on the trial manufactures by measuring the volumetric and the mechanical efficiency. And from that result, maintaining the same characteristic as the conventional one in the relief pressure and noise level, the experimental pump discharges 0.7 $\ell$/min and shows nearly 3.5% enhancement in the total efficiency more than the conventional one.

액분사 사이클을 이용한 공기 열원 열펌프의 사이클 시뮬레이션 (Cycle Simulation of an Air Source Heat Pump Using Liquid Injection)

  • 김욱중;홍용주;남임우;강원일;공용상
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.244-250
    • /
    • 2000
  • An air source heat pump using liquid injection technique, which can be applied for very low temperature climate, has been simulated to examine the design options. Comparison between the simulation and experiment has been carried out to validate the simulation method. Effects of various design parameters such as liquid injection rate and injection pressure are Investigated to optimize the performance of the heat pump. Finally, optimal liquid infection rate and injection pressure to maintain sufficient heating capacity and moderate discharge refrigerant temperature are suggested when the heat pump was operated at very low outdoor temperature.

  • PDF

Effect of Internal Flow in Symmetric and Asymmetric Micro Regenerative Pump Impellers on Their Pressure Performance

  • Horiguchi, Hironori;Matsumoto, Shinji;Tsujimoto, Yoshinobu;Sakagami, Masaaki;Tanaka, Shigeo
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권1호
    • /
    • pp.72-79
    • /
    • 2009
  • The effect of symmetric and asymmetric micro regenerative pump impellers on their pressure performance was studied. The shut off head of the pump with the symmetric impeller was about 2.5 times as that with the asymmetric impeller. The computation of the internal flow was performed to clarify the cause of the increase of the head. It was found that the contribution of the angular momentum supply was larger than that of shear stress for the head development in both cases. The larger head and momentum supply in the case of the symmetric impeller were caused by larger recirculated flow rate and larger angular momentum difference between the inlet and outlet to the impeller. The larger recirculated flow rate was caused by smaller pressure gradient in the direction of recirculated flow. The decrease of the circumferential velocity in the casing was attributed to the smaller local flow rate in the casing.

전산유체역학을 이용한 워터펌프 축력 저감 (Reduction of the Axial Force of Water Pump Using CFD)

  • 조석현;신동성
    • 한국자동차공학회논문집
    • /
    • 제20권3호
    • /
    • pp.83-87
    • /
    • 2012
  • Computational Fluid Dynamics (CFD) method has been used to investigate the axial force of automotive water pump. As the excessive axial force can make some unexpected problems like impeller interference and coolant leakage we have focused on finding the cause of axial force and its reduction in this paper. First, we have tested the closed type water pump with and without balance hole by the calculation methods. By examining the pressure contour around the impeller, we have found that the axial force arises not only from the pressure difference around shroud but also from the pressure difference around hub. So we have tested two impellers - one is normal open type impeller and the other is open type impeller with modified hub. The results show that the axial force reduction is about 150~200N for normal one and 700N@3000RPM for modified impeller. And the hydraulic efficiency which is important in aspect of engine fuel efficiency is reduced about 6.5% for normal one but increased 4%@3000RPM for modified impeller.

고압 쿨런트 펌프의 막힘 방지를 위한 사이클론 타입 필터 (Cyclone Type Filter for Preventing Clogging of High Pressure Coolant Pump)

  • 김준환;강지훈;강성기
    • 한국생산제조학회지
    • /
    • 제24권6호
    • /
    • pp.599-604
    • /
    • 2015
  • Currently, the coolant system in industrial sites is an efficient process to keep clean cutting oils. However, the damage to a pump occurs due to a chip and debris when inhaled into the pump, and thus problems such as the reduction of both efficiency and lifespan might arise. In this study, a new type of filter was developed in order to primarily prevent the damage from the pump impeller and make it unnecessary to have the replacement and cleaning at the same time. This study found the problem reducing the suction volumetric efficiency and cavitation when inhaled, and conducted a method to solve the problem compared to the result of fluid analysis according to two velocity conditions. As a result, this study achieved the effect of lowering the pressure and meeting the suction flow rate by connecting the four filters.

응집제 자동혼합형 미세기포 발생장치와 무동력 부상분리조를 이용한 하수의 처리 (The treatment of sewage using DAF pump system with micro bubble and non-powered flotation tank)

  • 김동하;이수영;정의택
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.659-666
    • /
    • 2011
  • Although DAF(Dissolved Air Flotation) has been successfully accepted for water and wastewater treatment, the fundamental characteristics of the process have not been fully investigated. Water is saturated with compressed air to dissolve the air into the water at high pressure in saturation tank. Then the water containing dissolved air is released into a floatation tank at a lower pressure, generating micro-bubbles that rise gently through the water and carry the suspended matter to the surface. This study investigated the removal of sewage using automatic mixture type DAF pump and non-powered flotation tank. Characteristics of two devices were compared and analyzed with samples. The results showed that the PAC exhibited higher performance than other coagulants. When air dosage was 2.5ml/l/min, treatment was stable in operation. In the DAF pump with a pressure of 4 atm., the average size of bubbles was 36.2${\mu}m$. Removal efficiency of SS was 80%. At this time removal efficiency of COD was about 80%, of T-N was 30% and T-P was 70% in stable operation. It was concluded that DAF pump system with micro bubble performed higher efficiencies compared to general DAF system for treating wastewater.

Design analysis and simulation of an external helical gear

  • Jinlong Yang;Kwang-Hee Lee;Chul-Hee Lee
    • 드라이브 ㆍ 컨트롤
    • /
    • 제20권4호
    • /
    • pp.45-53
    • /
    • 2023
  • This study optimized the parameters of the helical gear based on the original external meshing helical gear pump, combined with the analysis of the stability and flow of the basic parameters of the equipment; herringbone gears were used to eliminate the axial force generated by the helical gears. An optimized helical gear rotor was built with NX. The error between the simulation and calculation results of pump displacement was 3.95% and the simulation results were valid. Analysis of the outlet pressure and lift changes (maximum change rates of 0.38% and 0.25%), pressure analysis of the XY center plane at different times in the same cycle (no pressure surge or drop), and analysis of the axial force of the primary and driven rotors (axis The axial force is close to 0) were performed. The results showed that the flow pulsation of the external gear pump was slight, the operation was smooth, vibration and friction were reduced, the wear of bearings and other components could be diminished, and the service life of the equipment was extended. The simulation results showed that the external gear pump met the design requirements.

재생 펌프의 날개 각도에 따른 성능 변화에 관한 실험적 연구 (Experimental Investigation on the Hydraulic Performance of the Regenerative Pump According to the Blade Angle)

  • 유일수;최원철;박무룡;이공훈
    • 한국유체기계학회 논문집
    • /
    • 제16권5호
    • /
    • pp.5-10
    • /
    • 2013
  • The regenerative pump is a kind of turbomachine which is capable of developing high pressure rise at relatively lower flow rates compared to the centrifugal and axial pumps. Although the efficiency of regenerative pumps is much lower than other turbomachines, still they have been widely used in many industrial applications for working at low specific speeds. There are some theoretical models to analysis the pump performance, however, the effect of the blade angle on the pump performance has not been covered in any model to date. In the present study, experimental study on the regenerative pump performance according to the impeller blade angle and its shape has been carried out. The straight radial blades with forward, backward and chevron blades which have inclined angles of $15^{\circ}$, $30^{\circ}$ and $45^{\circ}$ were tested. The pump performance characteristics as the pressure head, efficiency were obtained depending on the flow rate for every impeller, and their results, expressed in appropriate non-dimensional coefficients, were compared and analysed in detail. From the experimental results, it was found that the pressure head and the efficiency depend strongly on the blade angles as well as the blade type. These experimental data has made it possible to better understand the effects of the blade angle on the pump performance, and widen the applicability of the current performance analysis and design models with including the effect of blade angles.

초전도 케이블 냉각유로에서의 압력강하 특성 (Pressure Drop Characteristics on HTS Power Cables with LN2 Flow)

  • 고득용;염한길;이관수
    • 설비공학논문집
    • /
    • 제18권1호
    • /
    • pp.81-86
    • /
    • 2006
  • High temperature superconducting (HTS) power cable requires forced sub-cooled LN2 flow cooling. Liquid nitrogen is circulated by a pump and cooled back by cooling system. Typical operating temperature range is expected to be between 65 K and 77 K. The HTS power cable needs sufficient cooling to overcome its low temperature heat load. For successful cooling, the hydraulic characteristics of the HTS power cable must be well investigated to design the cables. Especially, the pressure drop in the cable is an important design parameter, because the pressure drop decides the length of the cable, size of the coolant circulation pump and circulation pressure, etc. This paper describes measurement and investigation of the pressure drop of the cooling system. In order to reduce the total pressure drop of the cooling system, the flow rate of liquid nitrogen must be controlled by rotational speed of the circulation pump.