• Title/Summary/Keyword: pump

Search Result 6,370, Processing Time 0.032 seconds

Three Dimensional Simulation Model of Fuel Delivery Jet Pump (연료 송출용 제트펌프 3차원 전산해석 모델)

  • PARK, DAIN;YUN, JIN WON;YU, SANGSEOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.3
    • /
    • pp.308-314
    • /
    • 2017
  • Jet pump in automotive fuel tank module is used to deliver fuel to fuel pump so that the pump is operated without aeration in suction side. In this study, three dimensional simulation model of jet pump is developed to understand performance variation over design parameters. Performance of jet pump is also investigated experimentally in terms of operating pressures. The experimental data is used to verify the three dimensional simulation model of jet pump. Verification results show that the three dimensional simulation model of jet pump is about 1% error with experiment. The simulations are conducted in terms of throat ratio and primary flow induction angle. As the throat ratio is increased, the flux ratio is trade-off at 3 times of throat diameter. On the other hand, as primary flow induction angle is increased, vapor pressure inside the nozzle is decreased. In summary, the results show that liquid jet pump has to be optimized over design parameters. Additionally, high velocity of induced flow is able to evolve cavitation phenomena inside the jet pump.

The effect of suction pipe leaning angle on the internal flow of pump sump

  • Lee, Youngbum;Kim, Kyung-Yup;Chen, Zhenmu;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.8
    • /
    • pp.849-855
    • /
    • 2015
  • A better flow condition for the intake of pump is provided by the sump pump that connects the forebay to the intake of the pump station. If the suction sump is improperly shaped or sized, air-entraining vortices or submerged vortices may develop. These phenomena may greatly affect pump operation if vortices become sufficiently large. Moreover, any remaining vortices in the pump flow passage may result in an increase in the noise and vibration of the pump. Therefore, the vortices in the pump flow passage must be reduced to achieve good pump sump station performance. In this study, the effect of suction pipe leaning angle on the pump sump's internal flow is investigated. Additionally, a pipe type with an elbow shape is investigated. The results show that the air entraining vortices occur under the condition of a water level ratio H/D = 1.31 for each suction pipe type.

Improvement of Pump Performance and Suppression of Cavitation in a Centrifugal Pump (원심펌프의 성능개선과 캐비테이션 억제에 관한 연구)

  • Choi, Young-Do;Kurokawa, Junichi
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.1
    • /
    • pp.18-25
    • /
    • 2008
  • Recent trends of a centrifugal pump are high speed in rotation and high pressure in head with high efficiency to meet the demands of industries. However, the newly developed pumps make trouble of pressure pulsation in the pumping system by performance instability of the pump. Moreover, cavitation, which is a main obstacle of high rotational speed in the pump, occurring in an impeller gives serious damages to the impeller and casing wall. The purpose of present study is not only to develop a simple method to improve pump performance but also to suppress the occurrence of cavitation in the centrifugal pump by use of J-Groove. J-Groove is a shallow groove installed on the casing wall in the meridional direction. The application of J-Groove to a centrifugal pump with a new type impeller of "semi-closed impeller" has proved its effectiveness as a useful countermeasure of the unstable pump performance and cavitation. The results show that the combination of semi-closed impeller and J-Groove can be applied successfully and improves both the pump performance and suction performance.

A Study on Thermo-flow Characteristics Analysis of Electric Water Pump (전동 워터펌프의 열유동 특성 해석에 관한 연구)

  • Kim, Sung-Chul;Song, Hyeong-Geun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.5
    • /
    • pp.95-101
    • /
    • 2012
  • An electric water pump for engine cooling system has an advantage which particularly in the cold start, the use of the electric water pump saves fuel and leads to a corresponding reduction in emissions. The canned type electric water pump without mechanical sealing elements was selected to meet the requirements for operational reliability and life. However, the electric water pump for internal combustion engine generates much more heat loss than for hybrid electric vehicle since it is operated by the electric power of high current and low voltage. In this study, the fluid flow and thermal characteristics of the canned type electric water pump as an inverter integrated water pump has been investigated under the effects of heat generation. The analysis conditions such as outdoor air temperature of $125^{\circ}C$, water pump speed of 6000 rpm, coolant temperature of $106^{\circ}C$ and coolant flow rate of 120 L/min was used as a standard condition. Therefore, flow fields and temperature distribution inside the water pump were obtained. Also, we checked the feasibility of the canned type for the electric water pump in comparison with the mechanical seal type.

Performance Characteristic of a Pipe Type Centrifugal Pump (파이프형 원심펌프의 성능특성에 관한 실험적 연구)

  • Yu, HyeonJu;Kang, Shin-Hyoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.5
    • /
    • pp.32-36
    • /
    • 2012
  • The positive displacement pump and the regenerative pump are widely used in the range of low specific speed, $n_s{\leq}100$[rpm, m3/min, m]. The positive displacement pump is not suitable for miniaturization and operation in high rotational speed. The regenerative pump has a problem with large leakage flow and low efficiency. While the centrifugal pump has advantages of high efficiency, miniaturization and high rotational speed, efficiency drops sharply with decrease in specific speed. Therefore the purpose of this study is to design a new type of centrifugal pump that has advantages of centrifugal pumps in operation in low specific speed. The name of this new type of pump was called 'Pipe type centrifugal pump', since the flow path through the impeller is simple circular pipe. Due to the simple shape of impeller, the manufacturing process is simple and cost is low. There is strong jet flow at the outlet of the impeller. This jet induces flow path loss, meridional dynamic pressure loss and mixing loss. Large disk friction makes the efficiency be limitted in the range of low specific speed. Even though the loss and the low efficiency, 'Pipe type centrifugal pump' represents stable performance, affordable pressure ratio and efficiency better than that of other low specific speed pumps.

The design of a charge pump for the high speed operation of PLL circuits (High speed에 필요한 PLL charge pump 회로 설계 및 세부적인 성능 평가)

  • 신용석;윤재석;허창우
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.2 no.2
    • /
    • pp.267-273
    • /
    • 1998
  • In this paper, we designed a charge pump with a differential current switching structure and it was made of a MESFET with high speed switching Property compared with CMOSFETs. The charge pump with a differential current switching structure is analyzed about operating property of circuit in high frequency band. Also we propose a method on it's characteristics estimation. The designed circuit is simulated by HSPICE simulator, and in view of the results we think that the charge pump of this study can be used in circuits of 1 GHZ frequency band grade.

  • PDF

Study on the Device for Pump Efficiency Measurement (펌프의 효율측정 장비에 관한 연구)

  • Bae, Cherl-O
    • Journal of Korea Ship Safrty Technology Authority
    • /
    • s.33
    • /
    • pp.53-62
    • /
    • 2012
  • Pumps are used widely in feed water, cooling & heating system and process line of industrial and construction fields. They consume nearly 20% of the each nation's total electrical energy. But The management of pump energy wasn't controlled well. Their loss of energy is huge if they have been operated at low efficiency. The first buying cost of pump is small compare to the power consumption of pump, so we can recommend the suitable replace time and best operating condition of parts and pump to measure the pump efficiency. Pump efficiency is usually measured according to the two methods which they are called thermodynamic method and traditional technique. And we measured the pump efficiency using two methods using potable pump efficiency measurement device and compared the results with the real performance curve offered from pump maker.

  • PDF

A Study on Serum Glucose Levels and the Pancreatic Beta-cell Protective Effect of Acupuncture on Streptozotocin-treated Rats by Subcutaneous Implantation of Osmotic Pump (Osmotic Pump모델 당뇨병 실험동물에서 침자극이 혈당조절 및 베타세포 보호작용에 미치는 영향)

  • Hur, Kwang-Wook;Kang, Sung-Gil;Kim, Yong-Suk
    • Journal of Acupuncture Research
    • /
    • v.24 no.4
    • /
    • pp.115-124
    • /
    • 2007
  • Objective: To evaluate the effect of acupuncture on streptozotocin(STZ)-treated rats by subcutaneous implantation of osmotic pump. Methods: STZ was administered to rats at a low dose with osmotic pump to induce beta cell death and diabetes (STZ osmotic pump model), The experimental animals were divided into 4 groups: 1. The control group which was not treated in the STZ osmotic pump model 2. The sham group which was acupunctured at an arbitrary point in the STZ osmotic pump model 3. The sample A group which was acupunctured at the Chung-wan($CV_{12}$) in the STZ osmotic pump model 4. The sample B group which was acupunctured at the Chok-samni($ST_{36}$) in the STZ osmotic pump model. The effect of acupuncture in the STZ osmotic pump model was observed by measuring the serum glucose level and immunostaining of pancreatic tissue of the rats. Results : STZ injection by subcutaneous implantation of osmotic pump caused hyperglycemia by destroying the pancreatic beta cell selectively. Acupuncture at the Chung-wan acupuncture point($CV_{12}$) and Jhok-samni acupuncture point ($ST_{36}$) in the STZ osmotic pump model separately resulted in a decrease of the serum glucose level. In addition, the cyto-protective effect of the pancreatic beta-cell was detected in the STZ osmotic pump model by acupuncture. And there were few differences between the effects of acupuncture at the CV12 and $ST_{36}$. Conclusion : Acupuncture at the CV12 and ST36 had beneficial effects on Type II diabetes mellitus, and action mechanism of the effect was thought to be concerned with secretion of endogenous beta-endorphin.

  • PDF

An Experimental Study on the Pump Operating Characteristics with Low Flow Operation (펌프의 저 유량 운전특성에 관한 실험적 연구)

  • 오광석;신필권;박종호;심우건;조두연
    • Journal of KSNVE
    • /
    • v.9 no.1
    • /
    • pp.85-96
    • /
    • 1999
  • For ASME Code pumps in nuclear power plants, inservice test is required to assess the operational readiness in accordance with ASME code and related regulations. The objective of this study therefore, is to develop the technical background of the degradation of pump performances and conditions due to low flow rate operation. In addition. the detection techniques of pump operating conditions are to be developed to enhance the safety and economy of nuclear power plants. A test loop consisted of pump, motor. water tank, flow rate measurements and piping system with flow control devices was established for this study. Two typical pumps, 1-stage volute pump and 3-stage turbine pump, were selected and the test was performed upon two major point of views ; i.e., pump discharge pressure pulsations analysis and pump vibration spectrum analysis. From the test results, it is concluded that (1) the pump vibration affected by the natural frequency of operating pump is significant in the low frequency zone (around 1 Hz) : the vibration amplitude. especially. is an important factor during low flow rate operation. and shall be monitored to ensure that it is within the limit of ASME OM code Part 6, (2) the vibration frequency and pump discharge pressure are affected by vane pass frequency and running speed, (3) the wave phenomena due to the compressiblity of water is anticipated during low flow rate operation. and the pump system shall be designed to prevent it and. finally, (4) the technical background of the degradation of pump performances and conditions due to low flow rate operation is provided.

  • PDF