• Title/Summary/Keyword: pump

Search Result 6,371, Processing Time 0.039 seconds

STUDY ON THE HYDRAULIC DESIGN OF 2 STAGE MIXED FLOW PUMP (2단 사류펌프의 임펠러 성능향상 방안 연구)

  • Kim, Y.J.;Woo, N.S.;Kwon, J.K.;Chung, S.K.;Park, U.S.;Bae, S.E.;Park, S.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.556-560
    • /
    • 2011
  • The seawater lift pump system is responsible for maintaining the open canal level to provide the suction flow of circulating water pump at the set point. The objective of this paper is to design a 2-stage mixed flow pump(for seawater lifting) by inverse design and to evaluate the overall performance and the local flow fields of the pump by using a commercial CFD code. Rotating speed of the impeller is 1,750 rpm with the flow rate of 2,700 $m^3/h$. Finite volume method with structured mesh and Realizable ${\kappa}-{\varepsilon}$ turbulent model is used to guaranty more accurate prediction of turbulent flow in the pump impeller. The numerical results such as static head brake horse power and efficiency of the mixed flow pump are compared with the reference data. Also, the periodic condition calculation method for the mixed flow pump was carried out in order to investigate the pump performance characteristics with the modification of impeller geometry.

  • PDF

Evaluation of Energy Savings for Inverter Driving Centrifugal Pump with Duty Cycles (인버터 구동 원심펌프의 급수 사용율에 따른 에너지 절감 평가)

  • Kim, Kyungwuk;Suh, Sang-Ho;Rakibuzzaman, Rakibuzzaman
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.6
    • /
    • pp.81-85
    • /
    • 2015
  • The purpose of this study is to evaluate energy savings for inverter driving multi-stage centrifugal pump. Variable speed driving pump system has high efficiency compared with constant speed driving pump system. Because of difficulty to estimate operating efficiency of variable speed driving pump system, energy saving rates are used to replace operating efficiency. energy saving rates are calculated from pump input power and pump duty cycle. But another researches have used pump duty cycles of each season for energy saving rate. In this study, for estimating energy saving rate more high accuracy, pump duty cycles are measured for 1 year. pump duty cycles, depending on the season and be classified according to the weekday/weekend or during the week day. By this pump duty cycles, Energy saving rate is calculated appropriately.

A Simulation Study on Fluid Flowing in Micro Pump (Simulation을 통한 미세 PUMP 내에서의 유체흐름 연구)

  • 김용천;김미진;김진명;김진현;류근걸
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.4
    • /
    • pp.233-239
    • /
    • 2002
  • The technology of joining BT (Biotechnology) with NT (Nanotechnology) must be rapidly arranged in 21c. Specially, the technical value is important more and more since the research about MEMS, which synthesizes BT and NT, is variously proceeding on the wide fields. This study by simulation shows the Fluid-Flow within micro Pump used in Bio-MEMS technology through Fluent Program. Namely, this experiment shows the most suitable external conditions and Pump Model within micro Pump by observing the flow of fluids as to the conditions of pressure, temperature and Model when the Fluid flows within micro Pump. We saw the variousness of pressure and temperature as to the existence of Chamber through examining by reference of Fluid-Flow. In the case of the existence of Chamber, the variousness of pressure and temperature is less than in the case of the non-existence of Chamber. By this simulation, we know that the Pump, which has a Chamber, affects the Fluid-Flow less than that. So we can say that it is necessary for us to design the Pump which has a Chamber.

  • PDF

ANALYSES OF ANNULAR LINEAR INDUCTION PUMP CHARACTERISTICS USING A TIME-HARMONIC FINITE DIFFERENCE ANALYSIS

  • Seong, Seung-Hwan;Kim, Seong-O
    • Nuclear Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.213-224
    • /
    • 2008
  • The pumping of coolant in a liquid metal fast reactor may be performed with an annular linear induction electro-magnetic (EM) pump. Linear induction pumps use a traveling magnetic field wave created by poly-phase currents, and the induced currents and their associated magnetic field generate a Lorentz force, whose effect can be the pumping of the liquid metal. The flow behaviors in the pump are very complex, including a time-varying Lorentz force and pressure pulsation, because an induction EM pump has time-varying magnetic fields and the induced convective currents that originate from the flow of the liquid metal. These phenomena lead to an instability problem in the pump arising from the changes of the generated Lorentz forces along the pump's geometry. Therefore, a magneto-hydro-dynamics (MHD) analysis is required for the design and operation of a linear induction EM pump. We have developed a time-harmonic 2-dimensional axisymmetry MHD analysis method based on the Maxwell equations. This paper describes the analysis and numerical method for obtaining solutions for some MHD parameters in an induction EM pump. Experimental test results obtained from an induction EM pump of CLIP-150 at the STC "Sintez," D.V. Efremov Institute of Electro-physical Apparatus in St. Petersburg were used to validate the method. In addition, we investigated some characteristics of a linear induction EM pump, such as the effect of the convective current and the double supply frequency (DSF) pressure pulsation. This simple model overestimated the convective eddy current generated from the sodium flow in the pump channel; however, it had a similar tendency for the measured data of the pump performance through a comparison with the experimental data. Considering its simplicity, it could be a base model for designing an EM pump and for evaluating the MHD flow in an EM pump.

Air-Water Two-phase Flow Patterns and Pressure Distributions in a Screw-type Centrifugal Pump

  • Kim, You-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1203-1210
    • /
    • 2004
  • It was reported recently that the pump head degradation near the best efficiency point from single-phase flow to the break-down due to air entrainment became less in a screw-type centrifugal pump than in a general centrifugal pump. In this paper, I carried out internal pressure measurements and visualizations, and investigated the various physical phenomena occurring inside a screw-type centrifugal pump operated in air-water two-phase flow. The results could give some characteristics about the degradation of pump performance on air-water two-phase flow.

Hydraulic design of fuel pump in turbo-pump system and performance evaluation using CFD (터보펌프용 연료펌프의 설계와 CFD를 이용한 성능 평가)

  • Lee, Kyoung-Hoon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.408-416
    • /
    • 2002
  • Hydraulic performance of the pump with an inducer was predicted by 3-D Navier-stokes calculation. The evaluated pump was the single-stage centrifugal pump with a separated inducer to pressurize fuel (LCH4) in Turbo-pump system with a specific speed (Ns) of approximately 0.3[rad/s, m3/s, J/kg] and a suction specific speed(s) of 15[rad/s, m3/s, J/kg]. That conventional pump was designed with the combination of 1-D theory and empirical correlation. In this study, preliminary design to select key parameters such as inlet flow coefficient was reviewed by investigating sets of the known design methods to achieve appropriate suction performance, and the performance of newly designed inducer and impeller was compared with the old one, using CFD method. The numerical results showed that the hydraulic efficiency of the new pump was predicted $5.5\%$ higher than that of the conventional one, through design parameter re-selection, configuration improvement and blade loading control

  • PDF

A Hydraulic-Oil Pump System using SR Drive with a Direct Torque Control Scheme

  • Lee, Dong-Hee;Kim, Tae-Hyoung;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.491-498
    • /
    • 2009
  • The hydraulic-oil pump is widely used for building machinery, brake systems of vehicles and automatic control systems due to its high dynamic force and smooth linear force control performance. This paper presents a novel direct instantaneous pressure control of the hydraulic pump system with SRM drive. The proposed hydraulic pump system embeds the pressure controller and direct instantaneous torque controller. Due to the proportional relationship between pump pressure and torque, pressure can be controlled by the motor torque directly. The proposed direct torque controller can reduce inherent torque ripple of SRM, and develop a smooth torque, which can increase the stability of the hydraulic pump. The proposed hydraulic pump system has also fast step response and load response. The proposed hydraulic pump system is verified by computer simulation and experimental results.

Exact analysis for overload of a charge-pump phase-locked loop (Charge-pump 위상 동기 회로의 과부하에 대한 정확한 해석)

  • 최은창;이범철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.12
    • /
    • pp.3069-3085
    • /
    • 1996
  • This paper shows an accurate charge-pump PLL model which considers the wave-form distortion in high speed operation of charge-pump PLL, the leakage current in loop filter, and a physical limit in charge-pump. With proposed model of charge-pump PLL, overload and stability are derived theoretically and the results are compared to the conventional model. Unlike the ideal charge-pump PLL that simplifies calculations, it is possible to analyze the transient-state and the steady-state at the same time with proposed accurate model. Thus, charge-pump over load, in the transient-state and the stead-state of charge-pump, is accuragely analyzed and the results are confirmed with simulation.

  • PDF

Numerical Analysis of Fluid Flow in a Fuel Pump for a Turbopump System (터보펌프용 연료펌프의 내부 유동 해석)

  • Choi, B. S.;Yoon, E. S.;Park, M. R.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.258-263
    • /
    • 2001
  • A fuel pump for a turbopump system has been designed under an international co-work program. The liquid methane fuel pump has an inducer, in front of centrifugal impeller blades, to improve cavitation performance. The three dimensional viscous flow in the fuel pump was investigated through numerical computation. An arrangement of the inducer and impeller has yielded a strong interaction between inducer and impeller blades. The performance of the pump was evaluated from the calculated results. A parametric study was performed for various design variables, and it could oner a database for design parameters to design a fuel pump. A modified design of a fuel pump was proposed by KIMM to improve pump performance.

  • PDF

PERFORMANCE ANALYSIS OF CANNED MOTOR PUMP (캔드모터펌프의 성능해석)

  • Ko, Sung-Ho;Kim, Yeon-Tae;Kwack, Young-Kyun;Kang, Min-Koo;Han, Seung-Yeul
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.181-186
    • /
    • 2010
  • A numerical study was conducted to predict the performance curve of a canned motor pump for SMART(System Integrated Modular Advanced ReacTor). The study used a computational domain which included not only the pump but also a suction pipe and a volute casing with a discharging pipe in order to simulate an experimental setup. The ANSYS CFX program was utilized to obtain flow characteristics inside the pump as well as the overall pressure rise across the pump operating on- and off-design points. Computed results showed that the performance of the pump at off-design points was much lower than expected. Special attention was made to find the cause of the low performance of the pump operating at low flow rate.

  • PDF