• Title/Summary/Keyword: pulsed mode

Search Result 172, Processing Time 0.023 seconds

Analysis and Design of a 3-phase Series-Resonant type High Voltage Capacitor Charger (3상 직렬공진형 고전압 커패시터 충전기의 해석 및 설계)

  • Lee, Byungha;Park, Sangeun;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.510-516
    • /
    • 2013
  • This paper suggests a 3-phase series-resonant type high voltage capacitor charger for an EML pulsed power system. The operating principle on the charger is explained by an equivalent circuit. Additionally, we analyze the charging characteristic in one discontinuous conduction mode and three continuous conduction modes. The analysis shows that the resonant current per phase is two thirds of the 3-phase charger's average charging current and one third of the single-phase charger's average charging current with the same capacity. We suggest a design method of the 3-phase capacitor charger in each operational mode and present an example of 3.5 kW capacitor charger at ${\omega}_s=0.33{\omega}_r$. The 3.5 kW 3-phase capacitor charger prototype is assembled with a TI28335 controller and a 40 kJ, 7 kV capacitor. The design rules based on the analysis are verified by experiment.

A New High Speed Pulsed Mode Switching DC Power Supply with High Power Factor (새로운 방식의 고속 펄스모드 스위칭 기능을 갖는 고역률 직류전원장치)

  • 안종수;노의철;김인동
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.1
    • /
    • pp.47-54
    • /
    • 2004
  • A new high voltage DC power supply is proposed. The proposed power supply is constructed with several power converters connected in series. It is easy to obtain high DC voltage for the same structure of each power converter. The output DC power of the proposed power supply can be disconnected from the load within several hundred microseconds at the instant of a load short-circuit fault. The rising time of the output DC voltage is also as small as several hundred microseconds, and there is no overshoot of the voltage because all of the output filter capacitors keep undischarged state even in load short-circuit condition. Therefore, the proposed scheme is suitable for the protection of frequent output short-circuit and fast on/off switching of output DC voltage. The proposed power supply has improved features such as simple structure, high power factor, and reduced size and volume compared with the conventional schemes. The operating principle is described and the validity of the proposed scheme is proved through simulations and experiments.

A Discrete-Amplitude Pulse Width Modulation for a High-Efficiency Linear Power Amplifier

  • Jeon, Young-Sang;Nam, Sang-Wook
    • ETRI Journal
    • /
    • v.33 no.5
    • /
    • pp.679-688
    • /
    • 2011
  • A new discrete-amplitude pulse width modulation (DAPWM) scheme for a high-efficiency linear power amplifier is proposed. A radio frequency (RF) input signal is divided into an envelope and a phase modulated carrier. The low-frequency envelope is modulated so that it can be represented by a pulse whose area is proportional to its amplitude. The modulated pulse has at least two different pulse amplitude levels in order that the duty ratios of the pulse are kept large for small input. Then, an RF pulse train is generated by mixing the modulated envelope with the phase modulated carrier. The RF pulse train is amplified by a switching-mode power amplifier, and the original RF input signal is restored by a band pass filter. Because duty ratios of the RF pulse train are kept large in spite of a small input envelope, the DAPWM technique can reduce loss from harmonic components. Furthermore, it reduces filtering efforts required to suppress harmonic components. Simulations show that the overall efficiency of the pulsed power amplifier with DAPWM is about 60.3% for a mobile WiMax signal. This is approximately a 73% increase compared to a pulsed power amplifier with PWM.

Detection of Laser excited Lamb-wave using Air-coupled Transducer and Identification of Propagation Mode using Wavelet Transform (공기-결합 트랜스듀서를 이용한 레이저 여기 램파의 검출과 웨이브렛 변환을 이용한 전파모드 규명)

  • Kim, Hyun-Mook;Kim, Hong-Jun;Jhang, Kyung-Young;Lee, Jun-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.851-856
    • /
    • 2003
  • This paper proposes a single-mode Lamb-wave generation and detection system using a pulsed laser as a generator and an air-coupled transducer combined with the wavelet transform analysis, as the detector. The laser source with arrayed linear slits was used to generate Lamb-wave which is able to control the wavelength of Lamb-wave to be generated by changing the slits separation. An ari-coupled transducer was used to receive Lamb-wave, which can selectably receive a single mode of leaky Lamb wave by changing the oblique angle of transducer, since the leaky Lamb-wave has unique leaky-angle according to the mode. Also, the received signal was processed by wavelet transform for the analysis in domain of time-frequency. The theoretical dipersion curve and the experimetal result was compared to show good agreement.

  • PDF

Temperature Field Measurement of Ventilation Flow in a Vehicle Interior (TLC와 컬러화상처리를 이용한 자동차 실내 환기유동의 온도장 측정)

  • 윤정환;이상준;김기원
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.1
    • /
    • pp.120-128
    • /
    • 1997
  • The variations of the temperature field in a passenger compartment were measured by using a HSI true color image processing system and TLC(Thermochromic Liquid Crystal) solution. This temperature measurement technique was proved to be useful for analyzing the ventilation flow. The flow field in the passenger compartment was visualized using a particle streak method with pulsed laser light sheet. The temperature field and flow field in the passenger copartment were affected significantly by the ventilation mode. The panel-vent mode heating had shorter elapse time to reach a uniform temperature than the foot-vent mode under the same ventilation condition and nonuniformity inside the passenger compartment could be minimized effectively by using the bilevel heating mode. The temperature increase rate in the rear passenger compartment was iower than the front compartment, especially in the vicinity of the rear seat occupants' knee level.

  • PDF

Optimized Design and Manufacture of Wideband Pulsed Gamma-ray Sensors (광대역 펄스감마선 탐지센서 최적화 설계 및 제작)

  • Jeong, Sang-hun;Lee, Nam-ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.223-228
    • /
    • 2017
  • In this paper, we are proposing an optimal design of wideband pulsed type gamma-ray sensors. These sensors were manufactured based on the design results and after word electrical properties were analyzed. The sensor input parameters were derived on the basis of pulsed gamma-ray spectrum and time-dependent energy rate, and the output current which were derived on the basis of the sensor sensitivity control circuit. Pulsed gamma-ray sensors were designed using the TCAD simulators. The design results show that the optimal Epi layer thickness is 45um with the applied voltage 3.3V and the diameter is 2.0mm. The doping concentrations are as follows : N-type is an Arsenic as $1{\times}10^{19}/cm^3$, P-type is a Boron as $1{\times}10^{19}/cm^3$ and Epi layer is Phosphorus as $3.4{\times}10^{12}/cm^3$. The fabricated sensor was a leakage current, 12pA at voltage -3.3V and fully depleted mode at voltage -5V. A test result of pulsed radiation shows that the sensor gives out the optimal photocurrent.

A Study On The Junctional Epithelial Downgrowth After DeEpithelization Using Pulsed Nd : YAG Laser In Rat Peiodontal Bone Defect Filled With Calcium Carbonate (백서 치주 골결손부에 calcium carbonate 이식 및 pulsed Nd:YAG 레이저에 의한 치은상피의 제거 후 접합상피의 치유양상)

  • Jeong, Cheol-Woong;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.276-292
    • /
    • 1996
  • The purpose of this study was to evaluate whether removal of gingival epithelium with pulsed Nd :YAG laser could inhibit the downgrowth of junctional epithelium after alloplastic material grafting in periodontal bone defect. The periodontal bone defects were created surgically on the palatal aspect of the upper right and left molar teeth in 30 rats and filled with resorbable calcium carbonate($Biocoral\;450^{(R)}$: Inoteb, France). The control sites(right molar area) was sutured. The test side (left molar area) received controlled deepithelization of the oral and sulcular epithelium with pulsed Nd:YAG laser($Sunrise\;Maste^{(R)}$: Sunrise Technologies, U.S.A.) under the mode of 1.75W, 15Hz, 116mJ/pulse and was sutured. The control and test sites were evaluated clinically and histologically, at 1, 3, 7, 14, and 28 days postoperation. Clinically, the gingiva showed normal color and shape at the 5th day in the control site and at the 10th day in the test sites. Histologically, the junctional epithelium was formed at the 7th day in the control sites and at the 14th day in the test sites, and the long JE attachment were observed at the 28th day in both sites. The attachment of connective tissue to root surface was observed initially at the 7th day in the control sites and at the 14th day in the test sites, and completed at the 28th day in both sites. In summary, these results showed that the removal of oral epithelium using pulsed Nd:YAG Laser could not prevent epithelial downgrowth after alloplastic material implantation in rat periodontal bone defect.

  • PDF

Diamond-Like Carbon Films Deposited by Pulsed Magnetron Sputtering System with Rotating Cathode

  • Chun, Hui-Gon;You, Yong-Zoo;Nikolay S. Sochugov;Sergey V. Rabotkin
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.4
    • /
    • pp.296-300
    • /
    • 2003
  • Extended cylindrical magnetron sputtering system with rotating 600-mm long and 90-mm diameter graphite cathode and pulsed power supply voltage generator were developed and fabricated. Time-dependent Langmuir probe characteristics as well as carbon films thickness were measured. It was shown that ratio of ions flux to carbon atoms flux for pulsed magnetron discharge mode was equal to $\Phi_{i}$ $\Phi$sub C/ = 0.2. It did not depend on the discharge current in the range of $I_{d}$ / = 10∼60 A since both the plasma density and the film deposition rate were found approximately proportional to the discharge current. In spite of this fact carbon film structure was found to be strongly dependent on the discharge current. Grain size increased from 100 nm at $I_{d}$ = 10∼20 A to 500 nm at $I_{d}$ = 40∼60 A. To deposit fine-grained hard nanocrystalline or amorphous carbon coating current regime with $I_{d}$ = 20 A was chosen. Pulsed negative bias voltage ($\tau$= 40 ${\mu}\textrm{s}$, $U_{b}$ = 0∼10 ㎸) synchronized with magnetron discharge pulses was applied to a substrate and voltage of $U_{b}$ = 3.4 ㎸ was shown to be optimum for a hard carbon film deposition. Lower voltages were not sufficient for amorphization of a growing graphite film, while higher voltages led to excessive ion bombardment and effects of recrystalization and graphitization.