• Title/Summary/Keyword: pulsed mode

Search Result 172, Processing Time 0.04 seconds

A Study on the Scribing of FTO using Pulsed Nd:YAG Laser (펄스형 Nd:YAG 레이저를 이용한 FTO 식각에 대한 연구)

  • Kim, Hee-Je;Park, Sung-Joon;Son, Min-Kyu;Lee, Dong-Kil;Lee, Kyoung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1407-1411
    • /
    • 2008
  • In material processing, a laser system with optimal laser parameters has been considered to be significant. Especially, the laser scribing technology is thought to be very important for fabricating DSSC(Dye sensitized solar eel!) modules with good quality. Moreover, the $TEM_{00}$ mode laser beam is the most dominant factor to decide the IPCE(Incident photon to current conversion efficiency) characteristics. In order to get the $TEM_{00}$ mode, a pin-hole is inserted within a simple pulsed Nd:YAG laser resonator. And the spatial field distribution is measured by using three size pin-hole diameters of 2.0, 6.0mm respectively. At that moment, each case has the same laser beam energy by adjusting the discharge voltage and pps(pulse per second). From those results, it is known that the pin-hole size of 2.0mm has the perfect $TEM_{00}$ mode. In addition, at the charging voltage of 1000V, 10pps and the feeding speed of 1.11mm/sec, the SEM photo of FTO(Fluorine-doped tin oxide) thin film layers shows the best scribing trace.

Growth and Chrarcterization of $SiO_x$ by Pulsed ECR Plasma (Pulsed ECR PECVD를 이용한 $SiO_x$ 박막의 성장 및 특성분석)

  • Lee, Ju-Hyeon;Jeong, Il-Chae;Chae, Sang-Hun;Seo, Yeong-Jun;Lee, Yeong-Baek
    • Korean Journal of Materials Research
    • /
    • v.10 no.3
    • /
    • pp.212-217
    • /
    • 2000
  • Dielectric thin films for TFT(thin film transistor)s, such as silicon nitride$(Si_3N_4)$ and silicon oxide$(SiO_2)$, are usually deposited at $200~300^{\circ}C$. In this study, authors have tried to form dielectric films not by deposition but by oxidation with ECR(Electron Cyclotron Resonance) oxygen plasma, to improve the interface properties was not intensionally heated during oxidation. THe oxidation was performed consecutively without breaking vacuum after the deposition of a-Si: H films on the substrate to prevent the introduction of impurities. In this study, especially pulse mode of microwave power has been firstly tried during FCR oxygen plasma formation. Compared with the case of the continuous wave mode, the oxidation with the pulsed ECR results in higher quality silicon oxide$SiO_X$ films in terms of stoichiometry of bonding, dielectric constants and surface roughness. Especially the surface roughness of the pulsed ECR oxide films dramatically decreased to one-third of that of the continuous wave mode cases.

  • PDF

A Seamless Control Method for Supercapacitor to Compensate Pulsed Load in DC Microgrid (직류 마이크로그리드에서 펄스형 부하 보상용 슈퍼커패시터 무순단 제어법)

  • Dam, Hung D.;Lee, Hong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.4
    • /
    • pp.265-272
    • /
    • 2018
  • This paper proposes a new control method for the supercapacitor (SC) to compensate the pulsed load and to enhance the power quality of the DC microgrid. By coordinating the operating frequency, the SC is controlled to handle the surge current, while the low-frequency current component is dealt with by the remaining sources in the system. The operation mode of the SC unit is automatically changed based on the state of charge and DC bus voltage level. Meanwhile, the mismatch in the power demand is covered by the SC unit by regulating the DC bus voltage level. The effectiveness of the proposed method is verified experimentally by the prototype with two distributed generators and one SC unit.

Applicability of Using GC-PDD (Pulsed Discharge Detector) for Multiresidual Pesticides Analysis

  • Oh, Chang-Hwan
    • Food Science and Biotechnology
    • /
    • v.15 no.6
    • /
    • pp.959-966
    • /
    • 2006
  • The electron-capture detector (ECD) of gas chromatographs (GC) has been used widely in pesticide analysis. However, as ECD relies on radioactive material, it is troublesome to purchase and maintain. Therefore, potent replacements for ECD were investigated. A Pulsed-discharge detector (PDD) for ECD was tested and the analytical results of PDD (ECD mode), ${\mu}ECD$, and nitrogen-phosphorus detector (NPD) were compared for 107 pesticides including organochroline, organophosphorus, pyrethroids etc. The number of pesticides identified at the lowest limit of detection (LOD) was 36, 29, and 2 for PDD, ${\mu}ECD$, and NPD, respectively. The remaining pesticides showed same response to PDD and ${\mu}ECD$. The GC-PDD analysis of pesticides spiked into representative agricultural products (brown rice, spinach, and mandarin oranges) also showed good and/or equivalent recoveries using $GC-{\mu}ECD$.

A High Voltage Poorer Supply for Electrostatic Precipitator with Superimposing Voltage Pulse on DC Source (펄스 및 직류 중첩형 전기집진기용 고전압 전원장치 개발 연구)

  • Kim, Jong-Soo;Rim, Geun-Hie;Lee, Sung-Jin;Kim, Seung-Min;Cho, Chang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.12
    • /
    • pp.624-630
    • /
    • 2001
  • The trend of the regulations on environmental issues are getting tight. Responding to this trend new technologies such as moving electrodes, wide pitch and pulsed power supply are also introduced in the electrostatic precipitator(EP) systems. The introduction of wide pitch and moving electrodes enhances the system performance of the EPs by improving air-flow and by improving the ash reentrainment on rapping. The power supplies for the EPs developed up to date include thyristor-based dc or intermittent type, SMPS(switching mode power supply) type and the pulsed-power supply type. The use of the pulsed ones is known to improve dust-collecting efficiency of high resistivity ash and reduces back corona occurrence in the collecting plate. There are two kinds of pulsed-power supplies; one with pulsed transformers and the other with direct dc switching devices. The latter uses rotary spark gap switches or semiconductor switches. Both have the merits and demerits: the spark gap switches are simple and robust but has short life time, hence, high maintenance cost, whereas the semiconductor switches have long life time but are costly. In this study, A high voltage power supply with superimposing voltage pulse on dc source was developed for EPs. This study describes circuit topology, operating principle of the scheme, and analysis of experimental results on Dong-Hae Power Plant. The pulsed power supply consists of a variable dc power supply with ratings of 60kV, 800mA and pulse generator which is made of high voltage thyristor-diode switch strings, an LC resonant tank and a blocking inductor. The pulse generator generates variable pulse-voltage up to 70kV using a high frequency resonant inverter with a variable dc source. Two prototypes were built and tested on 250MW DongHae power plant to verify the possibility of the commercial use and the normal operation in the transient states.

  • PDF

Passive Mode-Locking of Nd:YAG laser with Saturable Absorber

  • Ahn, Seung-Joon
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1989.02a
    • /
    • pp.13-19
    • /
    • 1989
  • Passive mode-locking of a pulsed Nd:YAG laser is achieved with saturable absorbers, BDN dye in iodoethane solvent and Kodak Eastman # 26 dye in 1,2-dichloroethane solvent, and its optimum conditions are investigated. The thickness of saturable absorbers employed in the laser mode-locking is 0.16~0.50mm. The PBR (peak-to-background ratio) measured in the oscilloscope is 79.8% in Kodak Eastman # 26 dye at the neighbourhood of the peak power, whereas the passive mode-locking with BDN dye gives PBR of 67.7%. BDN and Kodak Eastman # 26 dyes are superior in photostability over Kodak eastman # 9860 and # 9740 dyes which were used previously in passive mode-locking. From the PBR curve, we find that Kodak Eastman # 26dye is more effective than BDN dye in passive mode-locking. The spacing between the adjacent pulses of the pulse train, which depends on the laser cavity length, is measured and is found to be 7 nsec for the cavity length of 100cm.

  • PDF

Guideline Development to Evaluate the Safety and Performance of Intense Pulsed Light(IPL) (Intense Pulsed Light의 안전성 및 성능평가를 위한 시험 항목 및 시험방법(안) 연구)

  • Kang, Dong-Yeon;Son, Tae-Yoon;Joo, Yea-Il;Choi, Eung-Ho;Jung, Byung-Jo
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.129-133
    • /
    • 2010
  • Intense pulsed light(IPL) is a photo-therapeutic medical device using xenon lamps with optical characteristics of incoherence, defocusing, and polychromatic. IPL has been recognized as a representative medical therapeutic device with growth of domestic skin care market. However, there is no standard regulation manual and guideline to evaluate the safety and performance of IPL. International Electrotechnical Commission(IEC) is being statued "Technical Report IEC TR 60825-16" which is a guidelines for the safe use of intense light source equipment on humans and animals. In this study, a standard Korea Food & Drug Administration (KFDA) regulation for the safety and performance of IPL was suggested by developing minimal evaluation methods for optical parameters of IPL such as output energy density, pulse mode, spot size, wavelength and uniformity of output light. We expect that this study may be a step to statue a standard regulation manual and guideline for IPLs used in domestic.

A Study on the Pulse Doppler System with M-mode Image and Spectrum Analyzer (주파수 해석기와 M-mode 영상을 갖는 펄스 도플러 장치의 개발에 관한 연구)

  • Jeong, Taek-Seob;Park, Sei-Hyun;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1217-1220
    • /
    • 1987
  • We have developed a Ultra Sound Pulsed Doppler System with two-dimensional M-mode image and Spectrum analyzer. The image of the M-mode is composed of time and depth axes. The Spectrum analyzer shows the spectrum of Doppler signal which represents the velocity component of time dependent blood-flow behavior. The spectrogram using Spectrum analyzer is composed of frequency and amplitude axes. The outputs of the system are audio signals, velocity curves, velocity profiles, M-mode images and spectrogram.

  • PDF