• 제목/요약/키워드: pulsed mode

검색결과 172건 처리시간 0.022초

Flow Actuation by DC Surface Discharge Plasma Actuator in Different Discharge Modes

  • Kim, Yeon-Sung;Shin, Jichul
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제16권3호
    • /
    • pp.339-346
    • /
    • 2015
  • Aerodynamic flow control phenomena were investigated with a low-current DC surface discharge plasma actuator. The plasma actuator was found to operate in three different discharge modes with similar discharge currents of about 1 mA or less. Stable continuous DC discharge without audible noise was obtained at higher ballast resistances and lower discharge currents. However, even with continuous DC power input, a low-frequency self-pulsed discharge was obtained at lower ballast resistances, and a high-frequency self-pulsed discharge was obtained at higher set-point currents and higher ballast resistances, both with audible noise. The Schlieren image reveals that the low-frequency self-pulsed mode produces a synthetic jet-like flow implying that a gas heating effect plays a role, even though the discharge current is small. The high-frequency self-pulsed mode produces pulsed jets in a tangent direction, and the continuous DC mode produces a steady straight pressure wave. Particle image velocimetry (PIV) images reveal that the induced flow field by the low-frequency self-pulsed mode has flow propagating in the radial direction and centered between the electrodes. The high-frequency self-pulsed mode and continuous DC mode produce flow from the anode to the cathode. The perturbed region downstream of the cathode is larger in the high-frequency self-pulsed mode with similar maximum speeds.

A Study to Compare the Radiation Absorbed Dose of the C-arm Fluoroscopic Modes

  • Cho, Jae-Hun;Kim, Jae-Yun;Kang, Joo-Eun;Park, Pyong-Eun;Kim, Jae-Hun;Lim, Jeong-Ae;Kim, Hae-Kyoung;Woo, Nam-Sik
    • The Korean Journal of Pain
    • /
    • 제24권4호
    • /
    • pp.199-204
    • /
    • 2011
  • Background: Although many clinicians know about the reducing effects of the pulsed and low-dose modes for fluoroscopic radiation when performing interventional procedures, few studies have quantified the reduction of radiation-absorbed doses (RADs). The aim of this study is to compare how much the RADs from a fluoroscopy are reduced according to the C-arm fluoroscopic modes used. Methods: We measured the RADs in the C-arm fluoroscopic modes including 'conventional mode', 'pulsed mode', 'low-dose mode', and 'pulsed + low-dose mode'. Clinical imaging conditions were simulated using a lead apron instead of a patient. According to each mode, one experimenter radiographed the lead apron, which was on the table, consecutively 5 times on the AP views. We regarded this as one set and a total of 10 sets were done according to each mode. Cumulative exposure time, RADs, peak X-ray energy, and current, which were viewed on the monitor, were recorded. Results: Pulsed, low-dose, and pulsed + low-dose modes showed significantly decreased RADs by 32%, 57%, and 83% compared to the conventional mode. The mean cumulative exposure time was significantly lower in the pulsed and pulsed + low-dose modes than in the conventional mode. All modes had pretty much the same peak X-ray energy. The mean current was significantly lower in the low-dose and pulsed + low-dose modes than in the conventional mode. Conclusions: The use of the pulsed and low-dose modes together significantly reduced the RADs compared to the conventional mode. Therefore, the proper use of the fluoroscopy and its C-arm modes will reduce the radiation exposure of patients and clinicians.

EMTDC를 이용한 8.5 MVA급 Magnetic Power Supply의 전력공급 시스템 분석 (Analysis of Power Supply System for 8.5 MVA Magnetic Power Supply Using EI)

  • 정응후;노의철;김인동;최정완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1114-1116
    • /
    • 2002
  • The characteristics of voltage drop and THD for parallel operating 11 PCRs (Phase Controlled Rectifiers) are analysed. The PCRs are used to drive high current (1.6 kA ${\sim}$ 3.7 kADC) electromagnetic coils for electromagnets. All the PCRs operate simultaneously in pulsed mode, and the pulse shot occurs every 150 seconds. During the pulse operation the PCR output current ramps up for 4 seconds, and then keeps flat top state for 2 seconds, and finally ramps down for 4 seconds. For the flat top mode a severe voltage drop and distortion appear in the power system because transformers for the PCRs are designed considering pulsed mode operation. It is expected that the analysis method can be applied to improve the system performance including power factor and design of high power pulsed mode operating power supply systems.

  • PDF

돼지에서 연속형 $CO_2$ 레이저와 펄스형 $CO_2$ 레이저를 이용한 피부절개시 창상치유 평가 (Comparison of Wound Healing in Porcine Skin with Continuous-Wave and Pulsed Mode $CO_2$ Laser Incisions)

  • 이재연;조성환;박창식;김명철
    • 한국임상수의학회지
    • /
    • 제27권6호
    • /
    • pp.647-651
    • /
    • 2010
  • 연속형 $CO_2$ 레이저와 펄스형 $CO_2$ 레이저를 이용한 돼지 피부절개 시 창상 치유에 미치는 영향을 평가하고자 본 실험을 실시하였다. 다섯 마리의 돼지(Landrace x Yorkshire) (45-51 kg, 4-6 개월령, 수컷 3마리, 암컷 2마리)를 이용 하였고, 각각의 돼지에서 우측 및 좌측의 등쪽 피부에 대칭적으로 연속형 $CO_2$ 레이저와 펄스형 $CO_2$ 레이저를 이용하여 절개($2{\times}2{\times}2cm^2$) 하였다. 양측 피부 절개는 Maxon 3-0 를 이용하여 봉합하였다. 수술 후 3, 7, 14, 21일에 병리조직학적 검사를 실시하였다. 창상 부위의 재상피화는 연속형 $CO_2$ 레이저 군에 비해 펄스형 $CO_2$ 레이저군에서 더 많이 이루어졌다. 육아조직 형성은 창상후 경과일 3일에 펄스 $CO_2$ 레이저군에서 유의적으로 높게 나타났다(P < 0.05). 섬유아세포는 창상후 경과일 7일에 펄스형 $CO_2$ 레이져군에서 유의적으로 많게 형성되었다(P < 0.05). 결론적으로 피부절개 시에 있어서 펄스형 $CO_2$ 레이저는 연속형 $CO_2$ 레이저에 비하여 재상피화, 육아조직형성 및 섬유아세포가 더 높게 나타났으며, 레이저 시술에 따른 조직손상을 적게 나타내었다. 따라서 피부절개 시에 있어서 펄스형$CO_2$ 레이저가 연속형 $CO_2$ 레이저 보다 더 적합할 것으로 판단된다.

레이저를 이용한 임프란트 이차수술시 온도변화에 관한 실험적 연구 (TEMPERATURE CHANGES OF IMPLANT SURFACE IN SECOND STAGE SURGERY WITH DETAL LASER : IN VITRO STUDY)

  • 안현정;김현철;최병갑;송언희;김래경
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.256-268
    • /
    • 1999
  • Submerged implants require secondary surgical uncovering of implants after healing period of 3-6 months. In surgical methods, there are surgical scalpel, tissue punch, electro-surgical, and laser-used uncovering, and so forth The objectives of this study are investigation and assessment of 1) thermal change in clinical application for uncovering of HA-coated implant and pure titanium implant irradiated by pulsed Nd-YAG, $CO_2$, and Er-YAG laser. 2) surface change of cover screws aaer irradiation using laser energy. The temperature of apex & side wall of implants were recorded at 10sec, 20sec, 30sec after 30sec irradiation to implant healing screw; 1) pulsed Nd-YAG laser; 2W, 20pps, contact mode 2) $CO_2$ laser; water-infused & non-water infused state, 2.5-3.5W, contibuous mode, noncontact mode 3) $CO_2$ laser ; non-water infused state, 3W, superpulse, noncontact. mode 4) Er-YAG laser; (1) non-water infused state, 10pps, 60mj, contact mode (2) water-infused state, 10pps, 60mj, 80mj, 101mj, contact mode. According to the results of this study, pulsed Nd-YAG laser is not indicated because of increased thermal change and pitting of metal surface of implant cover screw. By contrast, $CO_2$ laser & Er-YAG laser are presumed to indicate because of narrow range of thermal change & near abscence of thermal damage of metal surface. Dental laser is thought to be much helpful to surgical procedure when it is used as optimal power and time condition considering characteristics and indications of each laser. Further research is needed to verify that these techniques are safe and beneficial to implant success.

  • PDF

레이저 어블레이션에 의한 초전도 이중모드 공진기 제작 (Fabrication of Superconducting Dual Mode Resonator using Laser Ablation)

  • 박주형;양승호;이상렬;안달;석중현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.41-44
    • /
    • 1998
  • Dual mode resonators were fabricated using high temperature superconductor. The deposited material was $Y_1Ba_2Cu_3O_{7-x}$(YBCO) on MgO(100) substrate using pulsed laser deposition. Dual mode resonators were patterned by standard photolithography process and wet etching. At the back-side of the substrate, the ground plane with the metal layer of Ti and Ag was fabricated. The transition temperatures of YBCO films were 85-88 K, and network analyzer was used for testing the performance of the resonators. The input/output feedline angles of each resonator were $60^{\circ}$and $100^{\circ}$. The resonant frequency of resonators was 10 GHz. In this paper, dual mode resonator was fabricated for the application of satellite communication.

  • PDF

메탈 필름 저항의 펄스 대전력 시험 (Pulse energy high Power test of metal film resistor)

  • 손윤규;장성덕;권세진;오종석;조무현;이경태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2103-2105
    • /
    • 2005
  • Metal film type of resistor have been tested to invest maximum usable power at the pulsed high voltage and pulsed high current. Experiments were carried out using capacitor charging power supply and dump switch. Pulsed amplitude were varied from 1kV to 25kV. The peak current reached was 1kA. Datasheet are given for the limited pulsed power and energy for metal film type of resistor in nanosecond and microsecond time range. The experimental investigation of the threshold loading of the resistor in the high current and voltage pulsed mode has shown that the process of destruction of resistor has specific features for each mode. The mechanisms of failure and destruction of resistors under action of high-voltage and high-current pulses are discussed.

  • PDF

종펌핑 단일 종모드 섹소레이저 제작 및 특성연구 (Construction and Study of Longitudinally Pumped single Mode Pulsed Dye Laser)

  • 이종훈
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1989년도 제4회 파동 및 레이저 학술발표회 4th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.43-45
    • /
    • 1989
  • Single mode pulsed incidence dye laser which has TEMoo spatial beam pattern, near gaussian temporal shape and narrow band width(less than 500MHz) has been constructed The improved performance comes as a results of cavity length(~5cm) and definition of optical path by means of longitudinal pumping. Using 1.0X10-4M RH-6G dye, conversion efficiency was approximately 2.2% and tuning range was 548-564nm.

  • PDF

헬기탑재 다중모드 레이다 시스템 모델 설계 (Multi-Mode Radar System Model Design for Helicopter)

  • 곽영길;배재훈
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.208-212
    • /
    • 2003
  • An airborne radar is an essential aviation electronic system of the helicopter to perform various missions in all-weather environments. This paper presents the conceptual design results of the multi-mode pulsed Doppler radar system testbed model for helicopter. Due to the inherent flight nature of the hovering vehicle which is flying in low-altitude and low speed, as well as rapid maneuvering, the moving clutters from the platform should be suppressed by using a special MTD (Moving Target Detector) processing. For the multi-mode radar system model design, the flight parameters of the moving helicopter platform were assumed: altitude of 3 Km, average cruising velocity of 150knots. The multi-mode operation capability was applied such as short-range, medium-range, and long-range depending on the mission of the vehicle. The nominal detection ranges is 30 Km for the testbed experimental model, but can be expanded up to 75 Km for the long range weather mode. The detection probability of each mode is also compared in terms of the signal-to noise ratio of each mode, and the designed radar system specifications ate provided as a design results.

  • PDF

펄스 모드 발진기와 지연선로를 이용한 버블형 동작감지기 (Bubble-type Motion Detector Using a Pulsed-mode Oscillator and Delay Line)

  • 이익환;김동욱
    • 한국전자파학회논문지
    • /
    • 제26권3호
    • /
    • pp.342-348
    • /
    • 2015
  • 본 논문에서는 펄스 모드 발진기와 지연선로를 이용하여 새로운 감지 형태를 갖는 버블형 동작감지기를 제안하고, 설계 및 제작하였다. 제안된 동작감지기는 송신 신호의 펄스폭으로 버블 형태의 감지 영역을 형성하며, 지연선로에 의해 시간 지연되는 거리에 해당하는 물체에서 반사된 신호만을 감지하여 IF 신호를 만들어낸다. 제작된 동작감지기는 중심주파수 8 GHz, 펄스 폭 2 nsec, 펄스 주기 30 nsec를 갖는 펄스 모드 발진기를 신호원으로 사용하였으며, 7 nsec와 12 nsec의 지연 시간을 갖는 선로 2개를 사용하여 1 m, 3 m, 5 m의 위치에 버블막 형태의 감지 영역을 성공적으로 형성하여 물체를 감지하였다.